A01.1 Demo Plan
I. 11415 SECTION 15 INCLUDED FOR GENERAL REFERENCE WORK TO BE PERFORMED BY THE GENERAL CONTRACTOR (G.C.), APPLIED DE -IMAGING SHALL OCCUR ONCE BATH 4 BODY WORKS HAS RELOCATED AND VACATED FROM THEIR FORMER LEASE AS NEEDED TO STORE. SEE SELECTIVE DEMOLITION IN SPECIFICATIONS. SPACE OR FROM A TEMPORARY SPACE INTO THE NEWLY CONSTRUCTED OR REMODELED SPACE, AND NORMALLY 2. G.C. TO REMOVE ALL EXISTING LEASEHOLD IMPROVEMENTS AS REQUIRED TO ACHIEVE LEASE PLAN CONDITION, DEMOLITION FOLLOWING THE OPENING DATE OF THE NEW STORE. THE DE -IMAGING OF THE SPACE SHALL INCLUDE THE INCLUDES, BUT 15 NOT LIMITED TO 714E REMOVAL OF ALL EXISTING PARTITIONS, CEILINGS, FLOOR COVERINGS, PLATFORMS, FOLLOWING' DISPLAY SHOW WINDOWS, STOREFRONT (IF APPL.ICABLE), STOREFRONT SIGNAGE, CABINETS, ETC. UNLESS NOTED OTHERWISE D51OUTICN ALSO INCLUDES THE REMOVAL OF ALL EXISTING ELECTRICAL MECHANICAL, AND PLUMBING FIXTURES AND I. G.C. TO REMOVE ALL STOREFRONT SIGNAGE INCLUDING: PIN -MOUNTED OR SURFACE MOUNTED LETTERS OR EQUIPMENT, UNLESS NOTED OTHERWISE WITHIN LEASE SPACE AND ON TILE ROOF. SEE MEP DRAWINGS FOR SELECTIVE LOGOS, ILLUMINATED SIGNAGE, AND SIGNAGE OR LOGOS APPLIED TO T14E GLASS. DB`OUTIOI. 2. G.C. TO PATCH AND REPAIR ALL HOLES RESULTING FROM THE REMOVAL OF SIGNAGE AND PAINT TO MATCH 2.o. REVIVAL OF STOREFRONT SIGNAGE 15 THE RESPONSIBILITY OF 114E G.C. IF STOREFRONT FACADE IS TO REMAIN, G.C. TO EXISTING STOREFRONT. PATCH AND REPAIR EXISTING MALL FINISHES TO LIKE NEW CONDITION. 3. G.C. TO CLEAN GLASS TO REMOVE ANY RESIDUE FROM THE REMOVAL OF SIGNAGE OR LOGOS. 4. G.C. TO PAINT OUT ANY EXISTING SURFACE PAINTED SIGNAGE OR LOGOS 7O MATCH THE EXISTING S. G.C. TO COORDINATE WIT14 LANDLORD AND THE "ERB OF ALL ADJACENT TENANTS A CONVENIENT TIME TO PERFORM STOREFRONT. DISMOLITION WORK. G.C. IS TO PROVIDE AND INSTALL ALL TEMPORARY MEANS OF EGRESS, TEMPORARY LIQHTING, AND ALL S. G.C. TO REMOVE ALL AWNINGS AND FRAMES, PATCH AND REPAIR HOLES, AND PAINT 70 MATCH THE EXISTING SAFETY DEVICES IN ACCORDANCE WITH STATE AND L.00A. CODES AND LANDLORD REQUIREMENTS. STOREFRONT. 6. G.C. TO REMOVE SIGN AND MURAL (IF APPLICABLE) AT BACKWRAP, PATCH HOLES AND PAINT TO MATCH 4. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO ACCOMMODATE NEW WORK, PREVENT MOV51VT OR EXISTING WALLS. SETTLEMENT OF STRUCTURE(5). PROVIDE BRACING OR SHORING AS REQUIRED. G.C. WILL ASSUME LIABILITY FOR SUCH 7. G.C. TO REMOVE ALL DEPARTMENTAL SIGNAGE (IF APPLICABLE). MOVEMENT SETTLEMENT DAMAGE OR INJURY B. G.C. TO REMOVE ALL SIGNAGE INSIDE THE STORE OR VISIBLE IN THE STOREFRONT WINDOWS. S. G.C. TO EXERCISE EXTREME CARE DURING DEMOLITION AS TO NOT DISRUPT OR DAMAGE ANY EXISTING UTILITIES OR SPRINKLER q• G.C. TO DISPOSE OF ALL EXISTING SIGNAGE AND LOGO ELEMENTS, AND LEAVE SPACE CLEAN. LINES WHICH SERVICE ADJACENT TENANTS. G.C. WILL BEAR THE SOLE RESPONSIBILITY OF ANY SUCH DISRUPTION OR DAMAGE. 10. GEC. �TO�DESTROY ANY FLOOR FIXTURES LEFT INTHE VACATED SPACE, VERIFY WITH LSDIC PROJECT 6. G.C. TO COORDINATE THE REMOVAL, DISCONNECTION AND/OR CAPPING OF ANY UTILITIES WITH LANDLORD'S FIELD II. G.C. TO BLACKOUT ALL STOREFRONT WINDOWS. WINDOWS TO RECEIVE BLACKOUT TWE NIGHT OF CLOSING. REPRESENTATIVE. ALL ABANDONED E.ECTRICAL/T12" ONE CONDUIT, PLUMBING LINES, DRAIN LINES, AND MIECWWICAL. 12. G.C. TO REMOVE UTILITIES FROM LIMITED BRANDS NAME. DUCTWORK AS THE RESULT OF DEMOLITION SHALL BE REMOVED BALK TO THE LANDLORD'S ORIGINAL POINT. G.C. TO PLACE MARKERS TO INDICATE LOCH 11CN OF DISCONNECTED SERVICES. FULL WVAC suelcaNtRAI To INSPECT EXISTING CONDITIONS PRIOR TO DEMOLITION, AND DETERMINE WHETHER ANY COMPRESSOR DE -IMAGING NOTES - ALLOWANCE A M7. REFRIGERANT LINES ARE PRESENT THAT MUST BE PROPERLY DRAINED (TO EPA STANDARDS) PRIOR TO DEMOLITION. SEE IpN'Ap11-M0p-1lOTE %,�.I' DEMOLITION NOTES IN MEP SPECIFICATIONS. 0. ANY AND ALL COMBUSTIBLE MATERIALS SHALL BE REMOVED FROM CEILING PLENUM. THIS WORM SHALL INCLUDE, BUT IS NOT LIMITED TO, EXISTING LANDLORD AND/OR ADI4LINT TENANT ITEMS THAT ARE NOT SUITABLE FOR RA. PLENUM (I.E. C----- I EXTENT OF DEMOLITION TELEPONE, FIRE ALARM CABLES, M.) VERIFY SITE CONDITIONS. 9. G.C. IS RESPO 215LE FOR PATWING AND REPAIRING EXISTING FLOOR SLAB AND DEMISING WALLS AFTER COMPLETION OF TEMPORARY BARRICADE DBVUTICN AND PRIOR TO 114E COMMENCEMENT OF NEW CONSTRUCTION. G.C. TO PATCH, REPAIR AND LEVEL EXISTING FLOOR SLAB AND INFORM OWNER OF ALL SEVERE IRREGULARITIES IN EXISTING SLAB. G.C. TO PREPARE EXISTING SLAB FOR lO LEASE LINE I. UNLESS OTHERWISE DIRECTED BY THE OWNER'S PROJECT MANAGER. G.C. TO CONSTRUCT TEMPORARY INTERIOR PHASING BARRICADE(5) OF 5/8' 1I6mm3 GYP. BOARD EACH SIDE OVER 3 5/8' 192n 3 METAL STUDS 0 24' O2 (E) BULKHEAD / NEUTRAL PIER TO REMAIN 1610mm3 O.C. BARRICADES ARE TO BE FULL HEIGHT AND BE ADEQUATELY SECURED AND BRACED - NEATLY TAPE OR SEAL AT CEILING AS REQUIRED FOR DUST PROOF CONDITION. TAPE AND SPACKLE GYP. BOARD O3 (E) DEN151NG WALL TO REMAIN. REMOVE EXISTING FINISHES TO FACE OF DEMISING WALL, TAKING CARE NOT TO SMOOTH. PRIME AND FINISH PAINT TO MATCH STORE WALL COLOR. G.C. IS TO INSTALL OWNER SUPPLIED, D15TURB EXISTING FACE OF GYP. BD. SURFACE MOUNTED WALL STANDARDS AT 24' 1610mm3 O.C. FROM FLOOR TO CEILING ON SALES SIDE OF BARRICADE, INSTALL IN -WALL BLOCKING AS NECESSARY BEHIND EACH STANDARD. (FEE FOR CONSTRUCTION AND ® (E) COLUMNS TO REMAIN. REMOVE EXISTING FINISHES AND MAINTAIN EXISTING RATING AS READ, FIN1514 OF WALL MUST INCLUDE INSTALLATION OF WALL STANDARDS). RELOCATION OF BARRICADE WILL BE i REQUIRED BY G.C. AT PHASE TURNOVER. Q 2. NOT USED. © (E) ELECTRIC CONDUIT TO REMAIN 3. IF APPLICABLE, G.C. TO TEMPORARILY RELOCATE ONE EXISTING CASHWRAP, INCLUDING ALL NECE55ARY POWER, Q7 (E) PLUMBING / SPRINKLER LINE TO REMAIN CONTROL, AND TELEPHONE WIRING TO ACCOMPLISH SAME. O (E) MALL DUCTWORK TO REMAIN, SHOWN WATCHED 4. ALL CONSTRUCTION WORK MUST BE ACCOMPLISHED IN HARMONY WITH STORE PERSONNEL AND NOISY WORK TO ACCOMPLISHED AFTER HOURS. Q i BE BEFORE OR BUSINESS 0 11 (E) PARTITIONS / CABINETS / DOORS / CEILINGS / FLOORING TO BE DEMOLISHED, SHOWN DASHED 12 (E) PLUMBING LINE(S) 4 FIXTURES TO BE DEMOLISHED. CUT AND CAP AS REOD. SEE MEP DRAWINGS. 13 (E) HVAC UNIT, CURB AND DUCTWORK TO BE DEMOLISHED, SHOWN DASHED. SEE MEP DRAWINGS. REPAIR ROOF TO NEW CONDITION i® (E) ELECTRICAL EQUIPMENT TO BE REMOVED, SHOWN DASHED. SEE MEP DRAWINGS 15 STOREFRONT BARRICADE. G.C. TO CONSTRUCT ACCORDING TO TENANT CRITERIA AND SUPPLY FIELD DIMENSIONS TO OWNER'S VENDOR FOR GRAPHIC INSTALLATION - SEE SHEET AI 16 (E) FIRE SPRINKLER MAIN TO BE RAISED AS REQUIRED TO CLEAR NEW CEILING HEIGHTS. REFER TO REFLECTED CEILING PLAN AND FIRE PROTECTION DRAWINGS. INSTALLATION OF NEW FLOORING. FULL 10. G.L. TO CUT ALL NECE55ARY OPENINGS. ALL PROTRUSIChil MAIRKS, CRACKS, BROKEN AND/OR OTHER E9DENCE OF DAMAGED DEMOLITION PLAN LEGEND L PHASED PROJECT NOTES OR UNOUND STRUCTURAL CONDITIONS SHALL BE REMOVED REPLACED REPAIRED OR RESTORED AS DIRECTED BY GOVERNING 191.•ACM-L00101N pg.24.09 AUTHORITIES. , 11. G.L. TO COORDINATE WITH LANDLORD RESPONSIBILITY IN PERFORMING ANY AND ALL ROOF WORK. SUCH ITEM SMALL INCLUDE, BUT 15 NOT LIMITED TO ROOF CURBS, VENTS, PITCH PANS, FAN UNITS, ETC. PATCH AND REPAIR ROOF AND/OR DECK TO 1. TEMPORARY STOREFRONT ENTRANCES, WHEN REQUIRED, SHALL BE CONSTRUCTED BY G.L. OF ALL NEW ORIGINAL AND WFATNERTIGHT CONDITION. VERIFY SITE CONDITIONS. MEMBERS AND FINISHES TO MATCH PERMANENT STOREFRONT CONSISTING OF TEMPERED GLASS, ALUMINUM FRAMING AND GLASS DOOR ALUMINUM FRAME. ALL DOORS SHALL NAVE A NEW CYLINDER LOCK BY U-CHANGE 12. G.L. TO COORDINATE T14E REMOVAL, DISPOSAL AND/OR RETURN OF ALL EXISTING SECIURITY SYSTEMS WITH 044WS PROJECT LOCK INDUSTRIES, INC. AND DOOR PULL - CYLINDER AND PULL TO MATCH PERMANENT EQUIPMENT SHOWN ON MANAGER. THE G.C.'S FAILURE TO COORDINATE REMOVAL OF THESE ITEMS WILL RESULT IN A FINE THAT 15 EQUIVALENT TO THE STOREFRONT DOOR SCHEDULE ON SHEET A00.2. ALL KEYS TO BE TURNED OVER TO STORE MANAGER. COST OF THE REPLACEMENT VALUE OF THE EXISTING SEOIRRY SYSTEM. 2. GENERAL CONTRACTOR SHALL PROVIDE CONDUIT AND CIRCUITING FOR TEMPORARY SENSORMATIC AND E. G.L. 15 RESPONSIBLE FOR THE REMOVAL OF ALL UNUSED, ABANDONED AND D iRANE015 ITEMS. BURNING MATERIAL ON SITE IS TEMPORARY EXIT SIGNAGE IF/AS REQUIRED. NOT PERMITTED, 14. G.C. TO NOTIFY OWNER IMMEDIATELY OF ANY SEVERE DISCREPANCIES OR IRREGULARITIES DISCOVERED DURING DEMOLITION WHICH MIGHT AFFECT THE PROPOSED STORE DESIGN, ESPECIALLY IN REGARDS TO 14EIQ4T AVAILABLE FOR CEILING, MECHANICAL DUCTWORK, RECESSED 1JGWTING AND ROLL. -UP GRILLES. 15. THE ARCHITECT 445 NO KNOWLEDGE OF AND SHALL NOT BE HELD LIABLE IF ANY ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE DISCOVERED DURING CONSTRUCTION. THE CONTRACTOR SHALL ISOLATE THE AFFECTED AREA AND CONTACT THE OWNER FOR FURTHER INSTRUCTIONS BEFORE PROCEEDING. THE ARCH TENT NAS NO KNOWLEDGE OF AND SHALL NOT BE LIABLE FOR ANY DAMAGES WOOED BY T14E EXISTING WATER LEAKAGES AND MOLDS. 16. G.C. 15 RESPONSIBLE FOR MAINTAINING FIRE RATING AT EXPOSED CEILING LOCATIONS DUE TO DEMOLITION OF (E) CEILING 17. THE G.C. SHOULD NOT CUT THE MAIN TELEPHONE WIRES LEADING TO T14E TERMINATION STRIP (DMARC BLOCK) OR NONE SYSTEM, N. IF THE DMARC 15 TO BE RELOCATED, (DUE TO DESIGN, SITE CONDITION OR DOWWSIZED SPACE), IT 15 TO BE COORDINATED WITH LIMITED TECHNICAL SERVICES (LTS). THE PRIMARY CONTACT 15 BRE•IDAN SMVEY AT 614.415.4077. 19. THE G.C. IS TO ALLOW ADEQUATE TIME FOR RELOCATION IN THE COSTRULTION SCHEDULE. 20. IF THE WALL WITH THE TELEPHONE BLOCK IS SCHEDULED FOR DEMOLITION, THE ENTIRE BACKING PANEL SHOULD BE REVVED FROM THE WALL (WITHOUT DISCONNECTING THE WIRING) MID MAST BE SAFELY SECURED IN THE CEILING UNTIL IT CAN BE RELOCATED TO THE NEW AREA OR REINSTALLED ON THE WALL. 21. NO EMERGENCY LIGHTS ARE TO BE ON THE PERIMETER DEMISING WALL FOR INTERFERENCE WITH 51GNAGE. IF EMERGENCY LIGHTS EXIST FROM LANDLORD OR PREVIOUS TENANT, THEY ARE TO BE REMOVED AND THE WALL PATCHED AND RETURNED TO A LIKE NEW CONDITION. FULL FULL DEMOLITION NOTES R 1 TEMP. STOREFRONT ENTRY NOTES v 42N.AOM-R00-NOTE nc In I, 42"01UN00•NOTE m qA ro FULL H I DEMOLITION PLAN KEYNOTES 44N-A071-PO0410TE OB.24.09 FULL D 42N.A011-000-NOTE p5 pq 16 LOWEST POINT OF (E) DECK: 179-7" 15360mm1 A.F.F. (V.I.F.) LOWEST POINT OF (E) STRUCTURE: 14'-4" 14369mm1 A.F.F. (V.I.F.) ED EC EB EA EY 612 30'-0' 30'-0' 32'-6' 470mm3 LVCL T9144mm3 CVCL E914*r31�I1CL T9906rcrn3 CVCL p_p" T29BI LULL T305mrn3 I I I I I ADJACENT TENANT BBW ROOFTOP CONDENSER LEASE LINE P CENTER OF (N..C.) PURSE STRINGS - - - MODEL TTAI8054000B EXISTING DEMISING WALL; IN. MALL SERVICE SERIAL 16175KP§TA 6' METAL STUDS W/ %` DOOR MAI 4/2O6 13 G.W.B. EA. SIDE 13 MALL PIER TO REMAINO r--- - - - .�FLOORS 1 ---------------- r- --�--------�1 1(f- �r-----�r--lll------I�--,r----1r--�L--- TRANS ION II --- - ------J_L----J�- ----- ---- ILL-- __ __�--� J--- 3�-6'KT-p' O r--- - - I - I 1 SERVICE SERVICE 4 ❑_K L ICJ 4 III II I E.W.0 II - I I Qom• r I Ty. ^CORRIDOR ^ DOOR I _ � Tw 1 II B.O. DECKIIIII I --_ __ - U �J ��\ \�\ I 9E5 LINE ROOFO7 ,••. B.O. JOIST ,;:. ,;;. B.O. i>Q ACT m. I11 LINE O HULIIEAD GRA I ABC Q Az TILE. 11 1MOPMoP _ = I6 i_ SINK@ _ _ H _ _ - _ J m - �R �_ - B.O. 6'P F.S.M. I L_ 4 J 1 B.O. 419 F.S.M. - - - 7 1 ALIGN GRAY --�--- F_ ---♦ 7 c-Fit I F F __ ,r, F _f_ _ f F F p f y L---T- DOORS W BARRICADE F.D. III is TILE. 1 / _ �-R _ _ _ _ _ _ _ 'R�- I PROPOSED 16 D. ` J rrr _ R_ �T� - - - - - R = '- 'Q ELEC OUTLET I_ _ _ I I R- ' r - - - -� -� - -R- I 0.0. VENT IN FLOOR r NEW OPENING L I F- - _ _ gg _ _ - I -- I 1 I e IIIII / �_ e r--- - ----- ----� 2 I I I 1 LJ 2 AC LINE SETS UP I WALK -OFF I I I 12 12 nT• J1 B.O. JOIST IB.O. JOIST 1 3 I TNRU DECK O7 I 1T-A 11 MAT I I \ TENANT'S TOILET ( I I j I Try B.O. AC LINEO7 M FLOOR 4 7 B.O. DECK �• WORKS BODY • I I I `�\ EXHAUST FAN 3 I I �- - - ./ _ _�_____ _ ___---- B.O. SANITARY LINE -L I I I \ Li ©0. BEAM r---T�- 1 _ T I I ~ I-- ---- -- 13 I I II o A 1 _ I I I �r �- r-I- r,r _ I B.O.so DECK I I I I II i I I I 11- J --- jz _ I I I 1 II II` - TI_I I _ LI-1____________ ___________J-l_____+_ - e.o. VAV I� SANITARY LINE I '- ' 1 3 �- ENTRY DOORS 8.0. DUCT B.o. SPR MAIN / I I I I I I/ I I I I ABOVE DI10TO7 B.O. 61RDER I �I 1 I L--TM L 7 LEASE LI B I \__ 11 T____�L__-- J FACE OF 1 TENANTS SUPPLY I '_ eO7 \\ I 1�y--- STOREF _ J I I I I AIR DUCT I3 I B.O. SANITARY LINE OUTSIDE AIR // _ 14" _ I - - - LT--F- - - - ' - - - - IIIII DUCK MODEL TWEIBOEMOAA/i I ,_1 , IIIII I vw vnv SAILOR Ipryl / 1 SERIAL 17354LS2WA I B.O. JOIST B.O.JOIST 1 11 B.O. DUCT / I MANUF 9/2017 r 1 I 1p_p I MODEL DMINE I_ I IIIII 55H BLADE I I I I B.O.DECK 1 I SERIAL 20006-I 13 B.O.DUCT _ SIGN II ELECTRICAL 1 O I I I 4 4'0 SANITARY �'-K B7UIPMENT� -J ----- -�t-t----J PIPE DOWN(2) r- T � � I I I I THOU FLOOR 1- I , 0.0. DECK - i_ 013 �77 LEASE LINE ®OUTSIDE OF 0.0. DUCT 1 1 1 - e EXISTING DEMISING WALL; 6' 4 B.O. DUCT 13 /// 11 METAL A. SIDE W/ 5/B' B.O. POWER I r / i 11 ----- - , -- -- -- II MALL PIER TO SERVICE 1 I L 8.0. DIK 13 11 11 J I J II F G'W.3. EA. SIDE CONDUIT© L_-_ ___ 7 . - xa. --- +m. J rJ , rn. Tm. / - 1 Tw. REMAINO --- - - - _ __ _ _ 00 -- ------------ - - - - �� - - - - -_---ram - - - - - 11f�F-�P ---1 7F-----9T--�1 - -z -----� ----- - - ----� t- - - --� ul_�L----=11F i1-C_=1-=- WATER SERVICE B'O WATER TENANT'S RETURN LEASE LINE H7 OUTSIDE OF ADJACENT TFlIANT VACANT RELEASED FOR CONSTRUCTION ENTRY POINT O MAIN O AIR DUCT13 EXISTING DEMISING WALL; b" METAL STUDS W/ 5/8 Subject to compliance with all regulations G.W.B. EA. SIDE of State and meal Codes I 3 City of Camlel '�"I •__ A714014n �Z 461 FROM ROAD PARAMUS NJ 07652 T1973.253.9393 fC WWW.SARGARCH.COM �Do /\ Z O DA V O of N a M J\ M L6 .o v 7 ov 111111. f- N (n Z EM L O U O 0 z Z 30 IL III V Y m v w�• a to ii wI E m D J OLL m ` a d U H H z R a'"® z 'J 55R at `g�o m�H3q E�Zk�� �yo �wiBs e.:k.k iS`E'H €ava= _�gBEB 'sRR s.kT O'z s' 14 h�7�= R�_� g ems sal@5@ .,R ffilaa � ail?`o3 ¥y g gdk" €C6�x E- €_ wj�s si aAIII E o �' `s . = a n RpFak464BoBM «=gE� Eli it 3RAz11 R€E3e iSik2 g "sE oa§as3P N84 E W R NM Oa O � 0 I Y N � VI a N 3.9 T° T E4 f N O Y :; � 15 O o� O G O 6 K S r 2 um w J t0 I() W - M 0 E O Q O N m � U � O wm� 0 fY �O DO J W m � tlJw �3 3 a� M m 3 O ♦Y o no, a F Eo "lift r c�i w _ It �g0a � L)W_ �& w QM W M dt=0'J Jaya oE^ REVISIONS: aEDmRED a• DATE E5 DATE ISSUED: 05/31 /2019 P N DESIGNED BY: JH DRAWN BY: FA CHECKED BY: YL DEMOLITION PLAN DRAWING NUMBER: 44P-A011-A00-PLIED