Loading...
HomeMy WebLinkAboutA11.2 Perimeter Cabinetry DetailsIQUAD OUTLET IN WALL, AS APPLICABLE. REFER TO POWER PLAN FOR LOCATIONS. MTL. BLOCKING TYP. @ 3 LOCATIONS OR O COMM CTDSVI CA IDENTIFY TOP OF STANDARD VS. BOTTOM PRIOR 70 INSTALL — DUPLD( CUTLET IN WALL, AS APPLICABLE, REFER TO POWER PLAN FOR LOCATIONS. I (E) FLOOR SLAB) p68R To PPL BTACNG DOCUIlNT FOR CABINET SHELF SPACNG STEP I 0 PLACE LOWER CABINET AND ATTACH TO TENANT WA THROUGH CABINET PRE -ATTACHED BLOCKING AT IN - METAL BLOCKING LOCATION, ATTACH WITH 3' 176M #12 WOOD TO METAL SCREWS @ 12' 305r 3 O.C. 0 APPLY BASE TRIM AND SCRIBE TO FIT STEP 2 DIAGONAL BRACE, SEE P/503.1 3 PLACE THE CENTER UNIT UPPER CABINET ON TOP 0 / FOR SIZE AND SPACING O LOWER CABINET. PLACE RECESSED STANDARDS INTC UPPER CABINET. REFER TO G.C. INFO DECK FOR CORRECT ORIENTATION OF STANDARDS, DRILL THRU PRESET HOLES IN STANDARD TO SECURE TO BLOCKING PRE -ATTACHED TO UNIT AT IN -WALL METAL BLOCKING 5/6' [I6mm] GYP. BD., REFER LOCATIONS. REFER TO SHOP DRAWING5 FOR RECESSED TO FINISH PLAN STANDARD PRE -DRILLED HOLE LOCATIONS. ATTACH WITH REFER TO RCP 3' 176mm7 #12 WOOD TO METAL SCREWS. AFTER — — _ — — — — — — _ _ _ B.O. CEILING STANDARD INSTALL PAINT SCREW HEADS BLACK TO MATCH. G.C. TO NOTCH BACK OF CABINET WHEN NECESSARY TO STEP 3 b„ ACCESS WALL OUTLET 153rwn] 9 5 3/4" A.F F® SLIDE SIGN FACADE INTO PLACE AND SECURE -- 1 ATTACH UPPER CABINET TRIMS + jSTEP 4 I I © PLACE SIDE UNIT UPPER CABINETS ON TOP OF SIDE UNIT I I LOWER CABINETS. PLACE RECESSED STANDARDS INTO \ l 1 UPPER CABINET. REFER TO G.G. INFO DECK FOR CORRECT ORIENTATION OF STANDARDS. DRILL THRU PRESET HOLES IN STANDARD TO SECURE TO BLOCKING al.l PRE -ATTACHED TO UNIT AT IN -WALL METAL BLOCKING LOCATIONS. REFER TO SHOP DRAWINGS FOR RECESSED STANDARD PRE -DRILLED HOLE LOCATIONS. ATTACH WITH II" [279rcrcn] HIGH 3' [76mm] #12 WOOD TO METAL SCREWS. AFTER SIGNAGE, REFER STANDARD INSTALL PAINT SCREW HEADS BLACK TO TO ELECTRICAL MATCH, DRAWINGS FOR POWER 0 SECURE SIGN FACADE BLOCKING REQUIREMENTS. PLW INTO © ATTACH UPPER CABINET TOP TRIM OUTLET BEHIND UPPER CABINET O9 VENDOR TO INSTALL SIGNAGE IF ILLUMINATED SIGN ll G.C. TO SECURE CABINET TO IN -WALL METAL BLOCKING W/ #12 SELF TAPPING SHEET METAL SCREWS @ PREDRILLED LOCATIONS IN RECESSED STANDARDS UPPER SHELVING UNIT AND ADJUSTABLE SHELVES V, kI 5 BAY TALL GABLE CABINET C TOUT FOR D2 INSTALLATION SEQUENCING POWER FEEDS au LOWER CABINET 014�G.C. TO NOTCH BACK OF DISTRIBUTOR CABINET WHEN NECESSARY TO ACCESS WALL OUTLETS —� � D1 I Alu DUPLEX OUTLET IN WALL BEHIND, REFER TO POWER PLAN FOR LOCATIONS SHELF LIGHTING D15TR15UTOP TO BE LOCATED IN HUTCH V I'Y BUNK. WIRING TO RUN FROM DRIVER THRU GABLE CUTOUT, TO SHELF LIGHTING 1 DRIVER d I 16' X 16' 1406rt X 406rt 3 :. ACCESS OPENING IN BACK OF O 1/4" # 1'.0" L 420.A118-1.00-0ETL 11.30. QUAD OUTLET IN WALL BEHIND, REFER TO POWER PLAN FOR LOCATIONS, STEP I I PLACE LOWER CABINET AND ATTACH TO TENANT WALL THROUGH CABINET PRE -ATTACHED BLOCKING AT IN -WALL METAL BLOCKING LOCATION. ATTACH WITH 3' 176mm7 7 6 12 WOOD TO METAL SCREW5 @ 12' E305mm3 O.C. 2O A Y BASE TRIM AND SCRIBE TO FIT _ STEP 2 0 PLACE ER CABINET ON TOP OF LOWER CABINET. a PLACE ED STANDARDS INTO UPPER CABINET. REFER TO .INFO DECK FOR CORRECT ORIENTATION OF STAN . DRILL THRU PRESET HOLES IN STANDARD TO ECURE TO BLOCKING PRE -ATTACHED TO UNIT AT IN -DUAL METAL BLOCKING LOCATIONS. REFER TO SHOP DRAWI FOR RECESSED STANDARD PRE -DRILLED HO TIONS. ATTACH WITH 3" [76mm7 #12 WOOD TO METAL REWS. AFTER STANDARD INSTALL PAINT SCREW HEADS K TO MATCH. STEP 3 O SLIDE SIGN FACADE INTO P E AND SECURE O5 ATTACH UPPER CABINET TRIM O A STEP 4 An.l © SECURE SIGN FACADE BLOCKING QUAD OUTLET IN WALL, APPLICABLE. TO O7 ATTACH UPPER CABINET TOP TRIM POWER PLAN FORFER LOCATION OB VENDOR TO INSTALL SIGNAGE O U 11 BASE AND FLOOR FINISHES. (SEE FINISH PLAN AND SCHEDULE) CABINET BASE SENT LONG, CARNET TYPES: IWBGCB-T-Vi# AND V/BGCSTB•VM G.C. TO SCRIBE TO FIT AND CABINET TYPES: IWBGCIFT-V3@ AND WBGCS-TB-V" C ALIGN W/ 6' WALL BASE All.l 1 1/2" - T-0" 5 BAY TALL GABLED CABINET SECTION P ELEVATION @ 5 BAY TALL GABLED CABINET .42D-A1124P00.OETL 1016,17 V-3 1/4" 5-4 3/4" [997mm) 1/2' [I5mm7 GAP 12559MMI NO BASE AT PARTIAL HEIGHT WALL FACE OF FULL HEIGHT WALL ABOVE I I I N � N �-" LINEAR LINKABLE LED LIGHTS REFER TO ELECTRICAL LIGHT SCHEDULE 1 E r. r. r. r. r. r.���r. r. r. r. r. r. r•r.� � _ STEEL DOWELS IN Tr —_ UFPER CABINET FOR ALIGNMENT WITH {TOLE IN BASE CABINET, TYP. POWER FEED ACCESS COVER PLATE ON COUNTER BELOW I I I 1 LINEAR LINKABLE LED LIGHTS REFER TO ELECTRICAL LIGHT SCHEDULE LED LIGHTING IN EACH SHELF AND BEHIND TOP VALANCE, REFER TO DETAIL D/AII.I PARTIAL HEIGHT WALL, REFER TO SECTION =MM==r.r.11llll.r.WM� EDGE OF LOWER CABINET I RECESSED STANDARDS, TYP. I I I I LINEAR LINKABLE LED LIGHTS REFER T.0 ELECTRICAL LIGHT SCHEDULE t ll����I.11lNlN��la� R 111Ill R7Jr1It1/%.t_iifR24 PI OR P2 AIY.1 AIT,I I OT 90H9 ICC CADSEI C IDENTIFY TOP STANDARD 1 V5. BOTTOM PRIOR TO INSTALL — GABLE CABINET INSTALLATION ENCING 42aA712-GOOHIETL REFER TO RC_PJL 5.0. CEILING q'-a 3/�L 5 ] A F.F.A T.O. CABIITETY �z 461 FROM ROAD �IY PARAMUS NJ 07652 him T1973.253.9393 R WWW.SAR"RCH.COM DIAGONAL BRACE, SEE A/ .I / FOR SIZE AND SPACING \v 5/9' Clbmm] GYP. BD REFER TO FINISH PLAN _REF R TO RC A. CEILTN G.C. TO NOTCH K OF CABINET WH ECESSARY TO ACCESS WAR OUTLET I^ ^1 Z onO c�'Jn F a 11j 1 U Sv C UD AI1.1 III N N a m 7 NIGH Z LL SI NArE, REFER O TO ELECTRICAL TO ELECTRICAL o • DRAWINGS FOR UPOKER U O REQUIREMENTS. O PLUG INTO OUTLET BEHIND ■` Z Y 16 UPPER CABINET i to ILLUMINATED N CL V SIGN W MID N 0 E d G.C. TO SECURE O N G CABINET TO ` IN -WALL METAL rl BLOCKING W/ #12 E SELF TAPPING 54EET METAL SCREWS 0 PREDRILLED LOCATIONS IN RECESSED STANDARDS UPPER SHELVING UNIT ANDr7 .40, ADJUSTABLE SHELVES Fr Ws'`- J o e%i'g;J ��Y1Y rWiiiy= x R4r l . se5a E Mv' 8@ ?€Om �Ny3 yEm4k 0R2�l kG�'Jc Nee77 p2 We e F°aiakl:€a I' Alla ��k � �H3a �sY �u a3gIJeX W h w '.� TOUT FOR LOWER CABINET a `b 4 � n mm ie A W M E k HER FEEDS E #o'^S wnn.v= DI TRIBUTOR Fac„r.- aN 4eINwk' ssWe#=c0§ 1 �% ry O L0 o I a'-2 3/4" jJW§=7 A. F,F.A DUPLEX OUTLET IN WALL, d N T.O. CABINET APPLICABLE. REFER TO c i o POWER PLAN FOR LOCAT S. /V� •- 111 [270r 3 HIGH BACK -LIT OR 0) N NON -ILLUMINATED SIGNAGE, REFER TO ELECTRICAL DRAWINGS FOR POWER -2 SHELF LIGHTINi DISTRIBUTOR i 41 REQUIREMENTS. PLUG INTO OUTLET BEHIND ) TO BE LOCATE IN HUTCH UPPER CABINET IF ILLUMINATED. L 'Y BUNK. WIRING T RUN FROM /A DRIVER THRU GA E CUTOUT, f V/ Tr TO SHELF LIGHTIN � O � W DRIVER `I O o 0 W 1= o 16" X 16' 1406rrm X Ill 2_711 C787rmm] A.F.F J.. lE) FLCO slJre) ACCESS OPENING N BACK T T.O. COUNTER a co a — DUPLEX OUTLET IN WALL BEHIND, REFER TO POWER m u7 PLAN FOR LOCATIONS. O N GO BASE AND FLOOR FINISHES. (SEE 0 � U O B-13 FINISH PLAN AND SCHEDULE) O M \o [] -0" ASINET TYPES: (WSGC3-T-V". WBGC3-TB-V4l, CABINET BASE SENT LONG, FINISHTED FLOOR /�N WBGC4-T-V4@ AND WBGC4-T8-V4* G.C. TO SCRIBE TO FIT AND W m J w ALIGN W/ 6' WALL BASE W W 3m U0 m 1/2" = 1'-0' F 1 1/2" = 1'-0" z 06 Q ALL GABLED CABINET SECTION B w o 491-A11Y-F004EELEV 05.15.la 0420-AI12-BOO10.16.17 � T W ~ uO e PUAD G.C. TO NOTCH BACK O' 0 (— r WPLIX OUTLET IN WALL DSCABINET WHEN NECESSARY z L L) wBEHIND LOWER CABINET al.l An.z TO ACCESS WALL ET REFERT C__P BELOW. REFER TO POWER PLAN B.O. ILING� w Q Q Obi w w U FOR LOCATION. SEE SECTION 91-8 3/41, [25 ] A.F,F.J, 'o MM J M ~ o H o FOR MOUNTING HEIGHT — L. 117-E T Y W U N U rail o .0. CA8a BASE BELOW 6-13 ir POWER FEED TRAVELS j DOWN SLOT TO BASE CABINET POWER FEED TRAVELS p \ ALONG SHELF EDGE AND �I ` 5/8' [I6mm7 GYP BD DROPS INTO THE TOP, I OVER MTL STUDS. PRE -INSTALLED ON SHELF LINEAR LINKABLE LED LIGHTS ER REFTO ELECTRICAL LIGHT SCHEDULE 1 SHELF RELEASED FOR CONSTRUCTIDN / F N19 Subject to compliance with all regulations 141-II 1/4' of State and meal Codes 14553man7 City of Cannel 'N"1#,A i BAY TALL GABLED CABINET (WBGC5—T—V## AND WBGC5—TS—V##) nATP- (17/1Fi/19 ■ SEE .I REVISIONS: RICUIRCD 3•: DATE I' ] NIGH BACK -LIT OR .. _. ._.. ON -ILLUMINATED SIGNAGE, REFER TO ELECTRICAL DRAWINGS 0000 FOR POWER REQUIREMENTS. PLUG INTO OUTLET BEHIND UPPER CABINET IF ILLUMINATED NOTE: ELEVATION IS FOR REFERENCE ONLY. REFER TO INTERIOR ELEVATIONS AND A PLAN FOR ACTUAL al.l NUMBER OF BAYS DATE ISSUED: 05/31/2019 [7a7r 3 A_F F A, -- — DESIGNED BY: JH DRAWN BY• YL 'Nm^NY®m1�b C��w. T.O. COUNTER DUPLEX OUTLET IN WALL CHECKED BY: YL BEHIND, REFER TO POWER PLAN FOR LOCATIONS. WBC PERIMETER B �O CABINETRY --—TSHTED FLAOR� DETAILS CABINET TYPE (WEIGC3-T-V", WBC WGC3-T8-V4d, BGC4.T-V" AND 1MBGC4-T8-V") A"' DRAWING NUMBER: 1 1/2" a T-0^ ^ 1/2" a T-0" o t E NATION @TALL GABLED CABINET 12D-A772f00-DETL ', 01.17.19 42E-AtE-AOOdLBVN10241