Loading...
HomeMy WebLinkAboutA15.1 SpecsLE:= r, I 3c W7200 GENERAL CONDITIONS (AMA A201-1997) 007300 SUPPLEMENTARY CONDITIONS DIVISION 01: GENERAL REQUIREMENTS 011100 SUMMARY OF WORK 013000 ADMINISTRATIVE REQUIREMENTS 014000 QUALITY REQUIREMENTS 015000 TEMPORARY FACILITIES AND CONTROLS 016000 PRODUCT REQUIREMENTS 016200 PRODUCT OPTION 0170W EXECUTION AND CLOSEOUT REQUIREMENTS 017300 EXECUTION 017900 DEMONSTRATING AND TRAINING DIVISION 02: EXISTING CONDITIONS (NOT USED) DIVISION 05: CONCRETE 03UW CAST UNDERLAYMENT DIVISION 04: MASONRY 044000 STONE ASSEMBLIES DIVISION 05: METALS 055000 METAL FABRICATIONS 057000 DECORATIVE METALS DIVISION 06: WOQU, PLASTICS AND COMPOSITES 061053 MISCELLANEOUS ROUGH CARPENTRY 062000 FIN15H CARPENTRY 064000 ARCHITECTURAL WOODWORK DIVISION 07: THERMAL AND MOISTURE PROTECTION 072100 THERMAL INSULATION 072400 EXTERIOR INSULATION FIN1514 SYSTEM 0759W ROOF REPAIRS 076000 FLASHING AND SWEET METAL 076M APPLIED FIREPROOFING 076400 FIRE STOPPING I79200 JOINT SEALANTS DIVISION 06: OPENINGS 081000 METAL DOORS AND FRAMES 051400 WOOD DOORS 088100 ACCESS DOORS AND PANELS 083220 SLIDING 4 STACKING GLASS DOOR SYSTEMS 083826 OVERHEAD COILING GRILLES 083516 SLIDING GRILLES 064113 ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS 02,4126 ALL -GLASS ENTRANCES AND STOREFRONTS 087100 DOOR HARDWARE OWIOO GLASS GLAZING OW300 MIRRORS DIVISION 04; FINISHES 092116 GYPSUM BOARD ASSEMBLIES 093000 TILING 095100 ACOUSTICAL CEILINGS 0%429 WOOD STRIP AND PLANKING FLOORING 096519 RESILIENT TILE FLOORING O%800 CARPETING 097216 VINYL -COATED FABRIC WALL COVERING 097216.16 RIGID SHEET VINYL WALL COVERINGS (FRP) 099000 PAINTING AND COATING 099000.10 PLASTER DIV15ION 10: SPECIALITIES 102113.13 METAL TOILET COMPARTMENTS 102613 CORNER WARDS 102513 TOILET ACCESSORIES IO51W LOCKERS 105626 MOBILE STORAGE SHELVING 1073B AWNINGS DIVISION II: EQUIPMENT (NOT USED) DIVISION 12: FURNISHINGS (NOT USED) DIVISION IS: SPECIAL CONSTRUCTION (NOT USED) DIVISION 14; CONVEYING EQUIPMENT (NOT USED) DIVISION 15 THRU 20: RESERVED DIVISION 21, FIRE SUPPRESSION (REFER TO SPRINKLER DRAWINGS) DIVISION 22: PLUMBING (REFER TO PLUMBING DRAWINGS) DIVISION 23; HEATING, VENTILATION, AND AIR CONDITIONING (REFER TO MECHANICAL DIVISION 24: RESERVED DIVISION 25: INTEGRATED AUTOMATION DIVISION 26: ELECTRICAL (REFER TO ELECTRICAL DRAWINGS) DIVISION 27: COMMUNICATIONS (REFER TO ELECTRICAL DRAWINGS) DIVISION 28: ELECTRONIC SAFETY AND SECURITY DIVISION 29: RESERVED DIVISION 30 THRU 39: 517E AND INFRASTRUCTURE (NOT USED) DIV15ION 40 THRU 49: PROCESS EQUIPMENT (INDUSTRIAL) (NOT USED) DIVISION DO - PROCUREMENT AND CONTRACTING REQUIREMENTS SECTION 0072W - GENERAL CONDITIONS A. GENERAL CONDITIONS: THE OWNERS STANDARD GENERAL CONDITIONS FOR CONSTRICTION I' INCORPORATED INTO THE CONTROLLING CONTRACT FOR CONSTRUCTION. I. A COPY WILL BE MADE AVAILABLE BY OWNER UPON REQUEST SECTION 0073W - SUPPLEMENTARY CONDITIONS A. CONDITIONS AND REQUIREMENTS: GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND DIVISION I - GENERAL REQUIREMENTS CONTAIN INFORMATION NECESSARY FOR COMPLETION OF EVERY PART OF PROJECT. B. DIVISION I: WHERE PROVISIONS OF GENERAL CONDITIONS RELATE TO PROJECT ADMINISTRATION OR WORK -RELATED REQUIREMENTS OF THE CONTRACT, THOSE PARAGRAPHS ARE EXPANDED IN DIVISION I. C. MISCELLANEOUS DEFINITIONS. I. APPROVED: REWIRES WRITTEN ACTION BY OWNER'S PROJECT MANAGER AS DOES TERN SUCH AS DIRECTED, SELECTED, REQUIRED, ORDERED, DESIGNATED, ACCEPTED, ACCEPTABLE, AND SATISFACTORY. 2. FURNISH: SUPPLY AND DELIVER TO PROJECT, UNLESS OTHERWISE STATED IN GREATER DETAIL. B. INSTALL: OPERATIONS AT PROJECT, FROM INSPECTING TO UNLOADING, TO COMPLETION IN PLACE, READY FOR INTENDED USE. 4. PROVIDE: FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE, UNLESS OTHERWISE STATED IN GREATER DETAIL. A. SCOPE: PROJECT CONSISTS OF CONSTRUCTION OF THE BATH 4 BODY WORKS AND/OR WHITE RELEASED FDR CONSTRUCTION IN CONTRACT DOCUMENTS. RACT) WILL BE FURNISHED AND INSTALLED BY OWNER Subject to compliance with all regulations of State and local Codes CONTRACT; OWNER WILL PROVIDE FOR HANDLING OF City of Carmel ZPARATE CONTRACT PRIOR TO T14I5 PROJECT. IF 1�n�l fiu� iPECTED, NOTIFY OWNER IMMEDIATELY. E.A.E. 07//19/10 B. WORK SEQUENCE: COORDINATE CONSTRUCTION SCHEDULE, OPERATIONS AND USE OF PREMISES WITH BUILDING MANAGEMENT. C. CONTRACTOR USE OF PREMISES: LIMIT TO AREAS INDICATED ON DRAWINGS AND AS SPECIFIED, LIMIT ACCESS AS DIRECTED BY OWNER. D. LINES AND LEVELS ENGINEERING: ESTABLISH LINES AND LEVELS BY USE OF RECOGNIZED ENGINEERING PRACTICES. LOCATED AND PROTECT CONTROL AND REFERENCE POINTS. E. REGULATORY REQUIREMENTS: PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH APPLICABLE CODES. COMPLY WITH CODE REQUIREMENTS FOR CONSTRUCTION. INFORM ARCHITECT OF DISCREPANCIES OBSERVED OR NOTED BY OTHERS. F. STANDARDS: COMPLY WITH STANDARDS REFERENCED EXCEPT WHERE MORE RIGID REQUIREMENTS ARE REQUIRED BY CODE. DATE OF STANDARD 15 THAT IN EFFECT AS OF DATE DOCUMENTS ARE ISSUED, EXCEPT WHEN SPECIFIC DATE 15 SPECIFIED. G. OWNER FURNISHED, CONTRACTOR INSTALLED ITEMS: OWNER WILL ARRANGE FOR AND PAY FOR PRODUCT AS INDICATED ON DRAWINGS TO BE DELIVERED TO PROJECT SITE FOR CONTRACTOR INSTALLATION. I. CONTRACTOR SHALL INSPECT, RECEIVE, UNLOAD, STORE, INSTALL AND FINISH AS DIRECTED. H. SUPERINTENDENT SHALL REMAIN ON JOBSITE THROUGH STORE OPENING 4 COMPLETION OF PUNCH -LIST. SECTICN 013000 - ADMINISTRATIVE REQUIREMENTS A. PROCEDURES: CONTRACTOR SHALL REVIEW AND APPROVED SUBMITTALS PRIOR TO SUBMITTING TO OWNER'S PROJECT MANAGER; INFORM OWNER'S PROJECT MANAGER IN WRITING AT TIME OF SUBMISSION OF ANY PROPOSED DEVIATION FROM CONTRACT DOCUMENTS. I. SUBMITTAL BY CONTRACTOR REPRESENTS THAT FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA NAVE BEEN DETERMINED AND VERIFIED BY CONTRACTOR. B. SHOP DRAWINGS: SUBMIT ONE REPRODUCIBLE AND TWO PRINTS; PROVIDE FOR CUSTOM PRODUCTS AND PRODUCTS NOT FULLY IDENTIFIED BY PRODUCT DATA. C. PRODUCT DATA: SUBMIT NUMBER REWIRED BY CONTRACTOR PLUS TWO FOR OWNER'S PROJECT MANAGE. INDICATE ITEM TO BE USED WHERE DATA FOR MORE THAN ONE PRODUCT OR OPTION IS INCLUDED; PROVIDE FOR EACH STOCK MANUFACTURED ITEM. D. MANUFACTURER'S CERTIFICATES: PROVIDE TWO. E. COORDINATION: COORDINATE USE OF PREMISES AND ACCESS TO SITE UNDER DIRECTION OF OWNER; COORDINATE WORK TO ASSURE EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATIO OF CONSTRUCTION ELEMENTS. I. MAKE PROVISIONS FOR OWNER INSTALLED ITEMS AND FOR SEPARATE CONTRACTS. 2. VERIFY CHARACTERISTICS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK HAVING INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTION TO, AND PLACING SUCH EQUIPMENT IN SERVICE. 3. COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK; CONCEAL PIPES, DUCTS, AND WIRING IN FINISHED AREA; COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH FINISHES. SECTION 014000 - QUALITY REQUIREMENTS A. GENERAL QUALITY CONTROL: MAINTAIN QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, PRODUCTS, SERVICES, SITE CONDITIONS, AND WORKMANSHIP, TO PRODUCE WORK OF SPECIFIED QUALITY, B. MANUFACTURER'S FIELD SERVICES: WHEN SPECIFIED IN RESPECTIVE SPECIFICATION SECTIONS REWIRE MANUFACTURER QU SUPPLIER TO HAVE QUALIFIED PERSONNEL PROVIDE ON -SITE OBSERVATIONS AND RECOMMENDATIONS. I. REPRESENTATIVE SHALL: a. OBSERVE FIELD CONDITIONS, INCLUDING CONDITIONS OF SURFACES. OBSERVE QUALITY OF WORKMANSHIP AND METHODS OF INSTALLATION. b. PROVIDE RECOMMENDATIONS FOR INSTALLATION AND WORKMANSHIP. c. WHERE REQUIRED, START, TEST, AND ADJUST EQUIPMENT AS APPLICABLE. d. SUBMIT WRITTEN REPORT TO OWNER'S PROJECT MANAGER OF OBSERVATIONS. C. MOCK-UPS: CONSTRUCT FIELD SAMPLES AND MOCK-UPS ON SITE A5 REQUIRED. D. TESTING LABORATORY SERVICES: TESTING SHALL BE BY AN APPROVED TESTING LABORATORY, AS REQUIRED BY SPECIFICATIONS AND BY APPLICABLE CODES. I. TESTING REQUIRED WILL BE PAID FOR BY OWNER EXCEPT RETESTING WILL BE PAID FOR BY CONTRACTOR WHERE REQUIRED BY FAILURE TO MEET ORIGINAL TESTS. 2. CONTRACTOR SHALL FURNISH MATERIALS AND SAMPLES FOR TESTS AND SHALL ASSIST TESTING LABORATORY AS REQUESTED. SECTION 015000 - TEMPORARY FACILITIES AND CONTROLS A. GENERAL: PROVIDE TEMPORARY CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS AS REQUIRED TO COMPLETE PROJECT IN ACCORDANCE WITH CONTRACT DOCUMENTS AND TO CONFORM WITH REQUIREMENTS OF APPLICABLE AUTHORITIES. I. CONTRACT GOVERNING AUTHORITIES TO ESTABLISH EXTENT OF TEMPORARY FACILITIES AND TEMPORARY CONTROLS REQUIRED BY AUTHORITIES. B. TEMPORARY POWER: PROVIDE POWER SERVICE AND LIGHTING REQUIRED FOR OPERATIONS, WITH BRANCH WIRING AND DISTRIBUTION BOXES LOCATED TO ALLOW SERVICE AND LIGHTING BY MEANS OF CONSTRUCTION -TYPE POWER CORDS. C. TEMPORARY LIGHTING: MINIMUM ILLUMINATION SHALL BE 5 FOOT - CANDLES FOR GENERAL CONSTRUCTION LIGHTING PER OSHA STANDARDS FOR CONSTRUCTION. D. TEMPORARY WATER AND SANITARY SERVICES. PROVIDE AND MAINTAIN REQUIRED DRINKING WATER AND SANITARY FACILITIES WITH ENCLOSURES. E. NOISE, DUST, AND POLLUTION CONTROL: PROVIDE MATERIALS AND EQUIPMENT NECESSARY TO COMPLY WITH LOCAL REQUIREMENTS FOR NOISE, DUST, AND POLLUTION CONTROL. F. BARRIERS: PROVIDE AS REQUIRED TO PROTECT ADJACENT PROPERTIES FROM DAMAGE FRO OPERATIONS; AND AS REQUIRED BY GOVERNING AUTHORITIES. I. BARRICADE AS REQUIRED BY CITY OR LANDLORD, IN ACCORDANCE WITH ALL CODES, CRITERIA AND DETAILS. 2. SECURITY: MAINTAIN SITE AND MATERIALS SECURE DURING CONSTRUCTION PERIOD. F. CLEANING: CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH; DISPOSE OF OFF -SITE AT INTERVALS AND APPROVED BY OWNER'S PROJECT MANAGER AND ACCEPTABLE TO APPLICABLE AUTHORITIES. G. SIGNS: SUBJECT TO APPROVAL OF OWNER'S PROJECT MANAGER. 14. STORAGE: LIMIT ON -SITE STORAGE TO AREAS DESIGNATED FOR CONSTRUCTION OPERATIONS AND APPROVED IN WRITING IN ADVANCE BY OWNER; PROVIDE ADDITIONAL WEATHER -TIGHT, SECURED OFF -SITE STORAGE AS REQUIRED. I. REMOVAL AND CLEANING: REMOVE CONSTRUCTION FACILITIES, CLEAN AND REPAIR DAMAGE, IN EXCESS OF CONTRACT REQUIREMENTS, CAUSED BY OPERATIONS OR USE OF TEMPORARY FACILITIES. SECTION 016000 - PRODUCT REQUIREMENTS A. CONTRACT AMOUNT: BASE ON MATERIALS AND PRODUCTS IN CONTRACT DOCUMENTS; WHERE LISTED IN CONTRACT DOCUMENTS, MATERIALS AND PRODUCTS BY MANUFACTURERS NOT LISTED SHALL NOT BE USED WITHOUT WRITTEN APPROVAL. B. PRODUCTS: CCMPCNNENT5 SUPPLIED IN QUANTITY SHALL BE INTERCHANGEABLE; PROVIDE NEW MATERIALS UNLESS OTHERWISE DIRECTED IN CONTRACT DOCUMENTS. C. INSTALLATION: INSTALL ITEMS PLUMB, LEVEL AND SECURE, AND IN CORRECT RELATION TO ADJACENT PRODUCTS; SECURE IN PLACE WITH POSITIVE AW 40RAGE DEVICES DESIGNED ANI SIZED TO WITHSTAND STRESSES, VIBRATION AND RACKING. I. COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE SPECIFIED. D. TRANSPORTATION: TRANSPORT PRODUCTS TO AVOID PRODUCT DAMAGE, DELIVER IN UNDAMAGED CONDITION IN MANUFACTURER'S UNOPENED CONTAINERS OR PACKAGING. E. HANDLING: PROVIDE EQUIPMENT AND PERSONNEL TO HANDLE PRODUCTS BY METHODS TO PREVENT 501LING AND DAMAGE; PROMPTLY INSPECT TO ASSURE PRODUCTS ARE CORRECT, COMPLETE, AND UNDAMAGED AND QUANTITIES ARE CORRECT. F. STORAGE: STORE MATERIAL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS, WITH SEALS AND LABELS INTACT AND LEGIBLE. G. PROTECTION: PROVIDE COVERINGS TO PROTECT PRODUCTS FROM DAMAGE FROM TRAFFIC AND CONSTRUCTION OPERATIONS, REMOVE WHEN NO LONGER NEEDED. H. SPECIFIED PRODUCTS: FOR PRODUCTS SPECIFIED BY NAMING ONE OR MORE PRODUCTS OR MANUFACTURERS, SELECT PRODUCTS OF ANY NAMED MANUFACTURER MEETING SPECIFICATIONS. SECTION 016200 - PRODUCT OPTION A. SUBSTITUTIONS AND PRODUCT OPTIONS: PROVIDE PRODUCTS INDICATED OR APPROVED; REQUESTS FOR SUBSTITUTIONS IN WRITING. I. CONTRACTOR OPTIONS: PROVIDE PRODUCTS AND MANUFACTURERS NAMED IN SPECIFICATIONS, SUBMIT REQUEST FOR SUBSTITUTION FOR PRODUCTS AND MANUFACTURERS NOT SPECIFICALLY NAMED WHERE NAMES ARE LISTED. B. SUBSTITUTIONS: CONTRACTOR SHALL INVESTIGATE PROPOSED SUBSTITUTIONS AND DETERMINE IF EQUIVALENT TO PRODUCTS SPECIFIED. SUBMITTALS SHALL INCLUDE COST OR TIME BENEFITS FOR SUBSTITUTION; FAILURE TO INDICATE COST OR TIME BENEFITS 15 JUSTIFICATION FOR REJECTION. C. CONTRACTOR'S REPRESENTATION: REQUESTS CONSTITUTE THAT C04TRACTOR/(5) HAS INVESTIGATED PROPOSED PRODUCTS AND DETERMINES IT MEETS OR EXCEEDS SPECIFIED PRODUCTS AND WAIVES CLAIMS FOR ADDITIONAL COSTS THAT SUBSEQUENTLY BECOME APPARENT. D. APPROVALS: OWNER'S PROJECT MANAGER SHALL BE JUDGE OF ACCEPTABILITY AND RESERVES RIGHT TO REJECT PROPOSED SUBSTITUTION BASED ON INSUFFICIENT INFORMATION; USE ONLY SUBSTITUTIONS APPROVED IN WRITING. SECTION 0170W - EXECUTION AND CLOSEOUT PROCEDURES A. INSTALLER QUALIFICATIONS: INSTALLERS TO HAVE MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE INSTALLING ITEMS 51MILAR TO THOSE REQUIRED FOR PROJECT, EXCEPT FOR INDIVIDUALS IN TRAINING UNDER DIRECT SUPERVISION OF EXPERIENCED INSTALLER. B. EXAMINATION: BEGINNING INSTALLATION OF A PRODUCT SIGNIFIES INSTALLER HAS EXAMINED SUBSTRATES, AREAS, AND CONDITIONS FOR COMPLIANCE WITH MANUFACTURER REQUIREMENTS FOR TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE. C. MANUFACTURER'S INSTRUCTIONS: WHEN WORK 15 SPECIFIED TO COMPLY WITH MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS, DISTRIBUTE COPIES TO OWNER'S PROJECT MANAGER. D. INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS UNLESS MORE RESTRICTIVE REQUIREMENTS ARE SPECIFIED. E. PROTECTION: COVER PRODUCTS SUBJECT TO DETERIORATION WITH IMPERVIOUS SHEET, PROVIDE VENTILATION TO AVOID CONDENSATION AND TRAPPING WATER. F. CUTTING AND PATC14ING: CUT AND FIT COMPONENTS AS REWIRED; PATCH DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHES. I. REFINISHING: REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE EVEN FINISH TO MATCH ADJACENT FINISHES; FOR CONTINUOUS SURFACES REFINISH TO NEAREST INTERSECTION, FOR AN ASSEMBLY REFINISH ENTIRE UNIT. G. FINAL CLEANING: CLEAN INTERIOR AND EXTERIOR SURFACES EXPOSED TO VIEW, REMOVE TEMPORARY LABELS, STAINS AND FOREIGN SUBSTANCES; POLISH TRANSPARENT AND GLOSSY SURFACES; VACUUM CARPETED AND SOFT SURFACES; CLEAN DUCTS; CLEAN SITE. H. SUBSTANTIAL COMPLETION: PROVIDE DOCUMENTATION STATING WORK HAS BEEN SUBSTANTIALLY COMPLETED. WHERE OWNER REWIRES USE OF SPACE PRIOR TO FINAL COMPLETION, PROVIDE LIST OF ITEMS TO BE COMPLETED. I. OWNER'S PROJECT MANAGER WILL REVIEW LIST OF ANY ITEMS TO COMPLETED AND SUPPLEMENT LI5T WITH ITEMS CONSIDERED TO BE INCOMPLETE OR UNACCEPTABLE. I. FINAL COMPLETION: PROVIDE WRITTEN CERTIFICATION INDICATING WORK IS IN COMPLIANCE WITH CONTRACT DOCUMENTS, SYSTEMS HAVE BEEN TESTED AND ARE OPERATIONAL, AND WORK IS READY FOR FINAL INSPECTION. J. PROJECT RECORD DOCUMENTS: MAINTAIN COMPLETE AND UP-TO-DATE RECORD DOCUMENTS; KEEP SEPARATE FROM FIELD DOCUMENTS. SUBMIT PROJECT RECORD DOCUMENTS, MATERIAL AND FINISH DATA, OPERATION AND INSTRUCTION MANUALS, WARRANTIES AND BONDS AT COMPLETION. I. SUBMIT BOUND IN 8-1/2' X 11' THREE RING BINDERS WITH DURABLE PLASTIC COVERS. ARRANGE IN FORMAT SIMILAR TO SPECIFICATIONS. K. WARRANTIES: PROVIDE WARRANTIES AS INDICATED, SIGNED BY CONTRACTOR AND MANUFACTURER; FORM AS APPROVED BY OWNER PRIOR TO EXECUTION. I. WARRANTIES SHALL BE IN ADDITION TO AND NOT A LIMITATION OF OTHER RIGHTS OWNER MAY HAVE AGAINST CONTRACTOR UNDER CONTRACT DOCUMENTS AND AS PRESCRIBED BY LAW, REGARDLESS OF WORDING OF WARRANTY. 2. PROVIDE A LIST OF SUBCONTRACTORS CONTACTS AND PHONE NUMBERS IN A FRAME MOUNTED ON OFFICE DOOR. INCLUDE THIS IN PROJECT CLOSEOUT PACKAGE. SECTION 017300 - EXECUTION A. SELECTIVE DEMOLITION: REMOVE FROM SITE EXISTING MATERIALS, CONSTRUCTION AND UTILITIES AS NEEDED TO COMPLETE PROJECT. REMOVE EXISTING ELEMENTS INDICATED AND ENCOUNTERED DURING CONSTRUCTION, AS NEEDED TO COMPLETE WORK. I. REMOVE ONLY THOSE ELEMENTS NECESSARY FOR COMPLETION OF PROJECT, REPLACE OR REPAIR ELEMENTS UNNECESSARILY REMOVED OR DAMAGED DURING CONSTRUCTION. B. CAREFULLY REMOVE AND STORE ITEMS INDICATED FOR REUSE IN PROJECT AND COORDINATI WITH OTHER TRADES AND MODIFICATIONS AND REINSTALLATION. C. PROTECTION: PREVENT MOVEMENT AND SETTLEMENT OF ADJACENT STRUCTURE, PROVIDE BRACING, SHORING, AND UNDERPINNING AS NEEDED AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURES. ASSUME LIABILITY FOR SUCH MOVEMENT AND SETTLEMENT. D. UTILITIES: CONTACT APPLICABLE UTILITY COMPANIES PRIOR TO DISCONNECTING UTILITIES; DISCONTINUE WORK IF UNEXPECTED UTILITY LINES ARE ENCOUNTERED . DETERMINE LINE SOURCE AND USE PRIOR TO REMOVAL. CAP AND IDENTIFY. SECTION O17900 - DEMONSTRATION AND TRAINING A. SUMMARY: PROJECT INCLUDES SPECIAL FACILITY START-UP PROCESS TO BRING FACILITY TO FULLY OPERATIONAL STATE, FREE OF DEFICIENCIES, IN MOST EFFICIENT AND TIMELY MANNER ACHIEVABLE. DIVISION 03 - CONCRETE SECTION 035400 - CAST UNDERLAYMENT A. GENERAL: PROVIDE POURED CEMENTITIOUS UNDERLAYMENT SYSTEM, NOT INTENDED AS FINISHED TRAFFIC SURFACE, INCLUDING ACCESSORIES AS REWIRED FOR COMPLETE INSTALLATION. B. SUBMITTALS: FURNISH MANUFACTURER'S LITERATURE. C. INSTALLER: FIRM WITH MINIMUM 5 YEARS SUCCESSFUL EXPERIENCE REGUTARLY ENGAGED IN INSTALLATION OF SPECIFIED MATERIALS, PROPERLY EQUIPPED AND ACCEPTABLE TO MANUFACTURER. D. MANUFACTURER: ARDEX, INC./K-15; W.R..50NSAI CO./SELF-LEVELING WEAR TOPPING, E. SYSTEM: POURABLE CEMENTITIOLS, HIGH -STRENGTH, FAST -SETTING, NON -SHRINK, SELF -LEVELING UNDERLATMENT; MINIMUM 40DO FBI COMPRESSIVE STRENGTH AT 28 DAYS, ASTM C349. TOLERANCE 15 TO BE 1/8' OVER TEN FEET. F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS H. FURNISH AND INSTALL EPDXY BASED, OR APPROVED EQUAL, MANUFACTURER RECOMMENDED LEVELING COMPOUND AT SENSORMAT PANEL UNITS. (SEE DETAIL IN ELECTRICAL DRAWINGS., DIVISION 04 - MASONRY SECTION 044000 - STONE ASSEMBLIES G. GENERAL: PROVIDE STONE FABRICATIONS FOR CLADDING AS INDICATED ON DRAWINGS, INCLUDING ANCHORS, MORTAR, GROUT, AND ACCESSORIES AS REWIRED FOR COMPLETE, FINISHED INSTALLATION. H. QUALITY CONTROL: OBSERVE STONE DURING FABRICATION AND ENSURE CONSISTENCY OF APPEARANCE, I. DEFECTS AND BLEMISHES: CONTRASTING SPOTS, FOREIGN ELEMENTS, IRREGULAR COLOI VARIATIONS, AND IRREGULARITIES IN TYPICAL CHARACTERISTICS SHALL BE CONSIDERE', DEFECTS AND BLEMISHES. C. COMPOSITE STONE: AS INDICATED ON DRAWINGS; EACH TYPE OF STONE SHALL COME FROM A SINGLE MANUFACTURER TO ENSURE CONSISTENT COLOR. D. MORTAR AND GROUT MATERIALS: ASTM C150, TYPE I PORTLAND CEMENT, A5TM C207, TYF 5 HYDRATED LIME, AND ASTM C144 SAND, CLEAN, FREE OF HARMFUL SUBSTANCES; USE WHITE CEMENT AT COLORED MORTAR AND GROUT, COLOR TO MATCH STONE UNLESS OTHERWISE INDICATED. E. ACCESSORIES: PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE SYSTEM. E. FABRICATION: PROVIDE STONE WITH EXPOSED SURFACES SMOOTH, TRUE AND FLAT. G. FABRICATION: FABRICATE AS SHOWN AND AS DETAILED ON FINAL SHOP DRAWINGS WITH EXPOSED SURFACES SMOOTH, TRUE, AND FLAT. I. CUT ACCURATELY TO SHAPE AND DIMENSIONS SHOWN ON FINAL SHOP DRAWINGS; COMPLY WITH FABRICATION TOLERANCES OF THE STONE ASSOCIATION (I.E. GRANITE INSTITUTE) FOR SPECIFIED FINISHES. ZERO TOLERANCE WHERE HAIRLINE JOINTS ARE REQUIRED, H. INSTALLATION: DO NOT USE MATERIAL WITH CHIPS, CRACKS, VOIDS, DISCOLORATION OR OTHER DEFECTS THAT MIGHT BE V1515LE OR CAUSE STAINING IN FINISHED WORK. I. STONE APPLICATION: INSTALL CURBS WITH SOFT STAINLESS STEEL WIRE ANCHORS, MINIMUM 1/8' DIAMETER SET WITH PORTLAND CEMENT WITH SHRINKAGE REDUCER (EXTERIOR); GROUT JOINTS. 2. EXECUTE WORK WITH SKILLED MECHANICS AND EMPLOY SKILLED FITTERS AT SITE TO DO NECESSARY FIELD CUTTING AS STONE 15 SET. TOOL JOINTS SLIGHTLY CONCAVE. DIVISION 05 - METALS SECTION OSSOOO - METAL FASNCATIOIRI A. GENERAL: PROVIDE MISCELLANEOUS METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS PART OF OTHER SECTIONS, WITH ANCHORS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. B. SUBMITTALS: FURNISH SHOP DRAWINGS FOR CUSTOM FABRICATIONS, PRODUCT DATA FOR MANUFACTURED ITEMS; PROVIDE TEMPLATES FOR ANCHOR INSTALLATION BY OTHERS. C. STEEL SHAPES: ASTM A36 STEEL. D. GROUT: PROVIDE NON -SHRINK, NONMETALLIC, PREMIXED, FACTORY PACKAGED, NON -STAINING, NON -CORROSIVE, NON-GASEOUS GROUT; TYPE SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED. E. FASTENERS AND ROUGH HARDWARE: TYPE REWIRED FOR SPECIFIC USAGE; PROVIDE ZINC -COATED FASTENERS FOR EXTERIOR USE OR WHERE BUILT INTO EXTERIOR WALLS. F. WELDING MATERIALS: AWS 01.1, TYPE REWIRED FOR MATERIALS BEING WELDED. G. PAINT: PROVIDE PRIMERS AS RECOMMENDED BY PAINT MANUFACTURERS FOR SUBSTRATES AND PAINTS SPECIFIED IN SECTION OEF100 - PAINTING. I. GALVANIZING REPAIR PAINT. HIGH ZINC -DUCT CONTENT PAINT FOR REGALVANIZING WELDS IN GALVANIZED STEEL. H. FABRICATION: FABRICATE ITEMS WITH JOINTS NEATLY FITTED AND PROPERLY SECURED; GRIND EXPOSED WELDS CONTINUOUS, SMOOTH AND FLUSH WITH ADJACENT FINISHED SURFACES, AND EASE EXPOSED EDGES TO APPROXIMATE 1/32' UNIFORM RADIUS. I. MAKE EXPOSED JOINTS FLUSH BUTT TYPE, 14AIRUNE JOINTS WHERE MECHANICALLY FASTENED. 2. FIT AND SHOP ASSEMBLE IN LARGEST PRACTICAL SECTIONS FOR DELIVERY. 3. FINISHES: GALVANIZE AND PRIME PAINT EXTERIOR MISCELLANEOUS METAL, PRIME PAINT INTERIOR MISCELLANEOUS METAL; GALVANIZE COATING MINIMUM C90 COATING, GALVANIZED AFTER FABRICATION. I. CLEAN SURFACES OF RUST, SCALE, GREASE AND FOREIGN MATTER PRIOR TO APPLYING GALVANIZED OR PAINTED FINISH. J. INSTALLATION: INSTALL ITEMS SQUARE AND LEVEL, ACCURATELY FITTED AND FREE FROM DISTORTION OR DEFECTS DETRIMENTAL TO APPEARANCE OR PERFORMANCE; ENSURE ALIGNMENT WITH ADJACENT CONSTRUCTION; COORDINATE WITH RELATED WORK TO ENSURE NO INTERRUPTION IN INSTALLATION. 1. SUPPLY ITEMS REWIRING TO BE CASE INTO OR EMBEDDED IN OTHER MATERIALS TO APPROPRIATE TRADES. 2. AFTER INSTALLATION, TOUCHUP FIELD WELDS AND SCRATCHED AND DAMAGED SURFACES; USE PRIMER CONSISTENT WITH SHOP COAT OR RECOMMENDED FOR GALVANIZED SURFACES, AS APPLICABLE. K. COLD -FORMED METAL FRAMING: CONFORM TO ASTM ODES 4 CICO7 WHERE INDICATED ON DRAWINGS (SEE DIVISION 9 SECTION 092115 FOR METAL FRAMING NOT INDICATED ON DRAWINGS). PROVIDE ACCESSORIES REWIRED FOR COMPLETE INSTALLATION. L. METAL BLOCKING: PRE -NOTCHED METAL BLOCKING TO BE NOTCH TITE BY METAL LITE INC. ANAHEIM, CA. (PH 800-066-6824) SECTION 057M - DECORATIVE METALS A. GENERAL: PROVIDE CUSTOM ORNAMENTAL METAL ITEMS AS INDICATED WITH ACCESSORIES AND ATTACHMENT DEVICES AS REWIRED FOR COMPLETE, FINISHED INSTALLATION. I. ORNAMENTAL METAL ITEMS: INSTALL STAINLESS STEEL AND BREAK METAL SHAPES AS INDICATED ON DRAWINGS. B. FABRICATOR: FIRM WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE FABRICATING ORNAMENTAL METAL ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT. C. STAINLESS STEEL: ASTM A666, TYPE 302/304 CORROSION RESISTANT STAINLESS STEEL WITH NO. 4 SATIN DIRECTIONAL FINISH. D. BRACKETS AND ANCHORS: UNEXPOSED PLATES, ANGLES AND SUPPORTS MAY BE STEEL; EXPOSED ITEMS TO MATCH ORNAMENTAL METAL TYPE AND FINISH. E. FASTENERS: TYPE REWIRED FOR SPECIFIC USAGE; PROVIDE CONCEALED FASTENERS EXCEPT WHERE SPECIFICALLY APPROVED; WHERE EXPOSE MATCH TYPE AND FINISH OF METAL BEING FASTENED. I. CONCEALED STEEL FASTENERS: HOT -DIPPED GALVANIZED MINIMUM G90 WHERE BUILT INTO EXTERIOR WALLS OR SUBJECT TO HIGH HUMIDITY. F. FABRICATION: FABRICATE COMPONENT CONNECTIONS TO SUPPORT SPECIFIED DESIGN LOADS. 1. SELECT MATERIALS FOR STRAIGHTNESS, FREE OF DEFECTS AND IRREGULARITIES. 2. EXPOSED -TO -VIEW SURFACES EXHIBITING PITTING, SEAM MARKS, ROLLER MARKS, 'OIL CANNING', STAINS, DISCOLORATION, AND IMPERFECTIONS ON FINISHED UNITS ARE NOT ACCEPTABLE. 3. MAKER EXPOSED JOINTS FLUSH BUTT TYPE, HAIRLINE JOINTS WHERE MECHANICALLY FASTENED; PROVIDE CONCEALED CONNECTION DEVICES WITH HIDDEN FASTENERS OR AS DETAILED. 4. SEPARATE DISSIMILAR MATERIALS WITH BITUMINOUS PAINT WHERE CONCEALED, WITH PERFORMED SEPARATORS, OR SIMILAR METHOD TO PREVENT CORROSION. G. INSTALLATION: INSTALL ORNAMENTAL METAL ITEMS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, INSTALLATION INSTRUCTIONS, AND APPROVED SHOP DRAWINGS. I. INSTALL PLUMB, TRUE AND IN CORRECT RELATION TO ADJACENT WORK, FREE FROM DISTORTION OR DEFECTS OMIMINTAL TO APPEARANCE AND PERFORMANCE. 2. PRIOR TO SECURING CONTINUOUS ITEM, ADJUST TO ENSURE PROPER MATCHING AT BUTT JOINTS AND CORRECT ALIGNMENT TWRWGHOUT THEIR LENGTH. 3. REPAIR OR REPLACE ITEMS DAMAGED OR MARRED DURING CONSTRUCTION. SECTION OGIM - ROUGH CARPENTRY A. GENERAL: PROVIDE MISCELLANEOUS ROUGH CARPENTRY. I. PROVIDE APPROVED FIRE RETARDANT TREATED (FRT) LUMBER, PLYWOOD AND TRIM WHERE REWIRED BY STATE OR LOCAL CODES AND WHERE NOTED ON DRAWINGS. ALL SUCH MATERIALS SHALL BEAR THE MANUFACTURERS STAMP OF AUTHENTICITY. 2. PROVIDE APPROVED PRESERVATIVE TREATED LUMBER, PLYWOOD AND TRIM WHERE EXPOSED TO THE EXTERIOR AND WHERE NOTED ON TEH DRAWINGS. ALL SUCH MATERIALS SHALL BEAR THE MANUFACTURERS STAMP OF AUTHENTICITY. B. STANDARDS: COMPLY WITH REQUIREMENTS OF AMERICAN PLYWOOD ASSOCIATION (APA), AND APPLICABLE CODE REQUIREMENTS. C. PLYWOOD: PROVIDE MINIMUM APA C-D EXTERIOR (CDX) PLYWOOD; STRESS RATED WHERE SPANNING SUPPORTING MEMBERS; FIRE RETARDANT TREATED; MINIMUM 3/4' THICK UNLESS OTHERWISE INDICATED. D. PLYWOOD STANDARD: COMPLY WITH PSI (ANSI A199.1). E. PLYWOOD PANEL BOARDS: PROVIDE PANEL BOARDS FOR ELECTRICAL AND COMMUNICATION PANEL BOARDS; APA C-O PLUGGED, INTERIOR TYPE PLYWOOD WITH EXTERIOR GLUE, FIRE RETARDANT TREATED, MINIMUM 1/2' THICK. F. FASTENERS: PROVIDE FASTENERS AS REWIRED FOR COMPLETE, SECURE INSTALLATION OF MISCELLANEOUS ROUGH CARPENTRY; ALL FASTENERS FOR P.T. OR F.R.P. WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER, OR AS OTHERWISE RECOMMENDED BY THE TREATED WOOD OR WOOD CONNECTOR MANUFACTURERS RECOMMENDATIONS. G. INSTALLATION: COMPLY WITH REFERENCED STANDARDS AND APPLICABLE CODE REQUIREMENTS. I. PLYWOOD: COMPLY WITH RECOMMENDATIONS OF AMERICAN PLYWOOD ASSOCIATION (AP) FOR FABRICATION AND INSTALLATION OF PLYWOOD WORK, 2. PLACE MISCELLANEOUS ROUGH CARPENTRY TRUE TO LINES AND LEVELS. 3. CORRELATE LOCATION 50 ATTACHED WORK WILL COMPLY WITH DESIGN REQUIREMENTS AND BE PROPERLY LOCATED. 4. CONSTRUCT MEMBERS OF CONTINUOUS PIECES OF LONGEST POSSIBLE LENGTHS. S. FIT CARPENTRY WORK TO OTHER WORK; SCRIBE AND COPE AS REQUIRED FOR ACCURATE FIT. 6. SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES BY ANCHORING AND FASTENING AS REWIRED BY RECOGNIZED STANDARDS. 7. PROVIDE WASHERS UNDER BOLT HEADS AND NUTS IN CONTACT WITH WOOD. SECTION OSGOOD - FISH CAROM A. STANDARDS: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWL)/QUALITY STANDARDS OR WOODWORK INSTITUTE OF CALIFORNIA (WIC) "MANUAL OF MILLWORK' STANDARDS; MINIMUM WIC/CUSTOM GRADE. B. SUBMITTALS: FURNISH PRODUCT DATA FOR MANUFACTURED ITEMS, SHOP DRAWINGS FOR CUSTOM ITEMS, SAMPLES OF EACH EXPOSED FINISH. C. CERTIFICATION: CERTIFICATION WILL NOT BE REWIRED. D. DELIVERY, STORAGE AND HANDLING: COMPLY WITH AWI OR WIC STANDARDS AND MANUFACTURER RECOMMENDATIONS. E. NON -SALES WOOD SHELVING: AWI OR WIC/CUSTOM GRADE HARDWOOD -EDGED PLYWOOD. 1. ADJUSTABLE SHELVING BRACKETS: INSTALL HEAVY DUTY STANDARDS AND BRACKETS WITH SLOTS 2' ON CENTER, SUPPORTS MAXIMUM 24' APART, AND MINIMUM 12' SHELF BRACKETS UNLESS OTHERWISE INDICATED. F. RECEIVE* INSTALL OWNER PROVIDED, PRIMED WOOD WALL BASE. 1. COPE ALL IN -CORNERS, MITER ALL OUTSIDE CORNERS. 2. BACK OUT AS REQUIRED TO PREVENT WRAPPING. DRILL WHERE NECESSARY TO PREVENT SPLITTING. 3. COUNTER SINK 4 PUTTY ALL NAIL HOLES, SAND SMOOTH. G. ANCHORS, NAILS AND SCREWS: SELECT THE MATERIAL, TYPE, SIZE AND FINISH REWIRED BY EACH SUBSTRATE FOR SECURE ANLHORACE; PROVIDE TOOTHED STEEL OR LEAD EXPANSION BOLT SCREWS FOR DRILLED -IN -PLACE ANCHORS. H. WOOD FILLER: COLOR TO MATCH WOOD BEING FILLED. I. FABRICATION: FABRICATE FINISH CARPENTRY ITEMS IN ACCORDANCE WITH SPECIFIED QUALITY STANDARD. J. IN5TALLATION: INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS; SHIM AS REWIRED, USING CONCEALED SHIMS. K. PREPARATION FOR FIELD FINISHING: SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS; APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS AND LEAVE READY TO RECEIVE SITE -APPLIED FINISHES. I. SEAL CONCEALED AND SEMI -CONCEALED SURFACES; BRUSH APPLY ONLY, USING PRIMER CONSISTENT WITH FINISH COASTS SPECIFIED UNDER SECTION 099W - PAINTING AND COATING. SECTION 064M - ARCN BCTU AL OOOOMONR A. GENERAL: INSTALL OWNER FURNISHED CASEWORK AND COUNTERTOPS; PROVIDE ACCESSORIE AS REWIRED FOR COMPLETE FINISHED INSTALLATION. "ImensimmilZ 461 FROM ROAD =�q;u PARAMUS NJ 07652 0 71973.253.9393 R WWW.SARGARCH.COM �N Z O (MO U) M N a M M n WWW"iD U cv D O Ni Of 10- 0-CID = 0 X C0 Z E LL = , U 0o 06 O CIO Z a m 3 p n � DO � v cn DO D_ V a LLJ -o _ (D E a)LL v J L O ai d V) 1- F B. STANDARDS: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWL)/QUALITY STANDARDS OR WOODWORK INSTITUTE OF CALIFORNIA (WIC) 'MANUAL OF MILLWORK' STANDARDS; MINIMUM PREMIUM GRADE. C. SUBMITTALS: FURNISH PRODUCT DATA FOR CONTRACTOR FURNISHED ACCESSORIES INCLUDING SAMPLES OF EXPOSED MATERIALS. D. STORAGE AND HANDLING: COMPLY WITH MANUFACTURER RECOMMENDATIONS. E. ACCESSORIES: PROVIDE AS INDICATED AND AS REQUIRED TO INSTALL ARCHITECTURAL g 7 @ g N y N € 4 o a WOODWORK AS INDICATED; COORDINATE ACCESSORIES REQUIRED FOR INSTALLATION OF 5 W OWNER FURNISHED ARCHITECTURAL WOODWORK NOT FURNISHED WITH ARCHITECTURAL a S " o % ; . o d x £ WOODWORK. - e N B D 9 �sE ..',go B=Peg3 F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND REFERENCED E = e : _ e c Ri 7 = = w STANDARDS. TAKE SPECIAL CAPE COORDINATING INSTALLATION OF OWNER FURNISHED `8 e V N w s = v N 6 ARCHITECTURAL WOODWORK WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION A r s y , = `Y $ E Z INSTRUCTIONS. S=ges x=w 6 -a`eb5 I. INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND s-=eu BGy �` STRAIGHT WITH NO DISTORTIONS. g e o e ° s A_ N W" gis „. mizXa �N 2. SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK. W o c N cyyTy s a6qa� S. ENSURE MECHANICAL AND ELECTRICAL. ITEMS AFFECTING ARCHITECTURAL WOODWORK � � � � € : E 0 e o 5 s le � y g ARE PROPERLY PLACED, COMPLETE, AND HAVE BEEN INSPECTED BY OWNER'S PROJECT uN¢33 e"y'-oii."g MANAGER PRIOR TO COMMENCEMENT OF INSTALLATION. $.F3ll h N ic C '.W g3�gg2 u=z ya 4. SECURE WORK TO GROUNDS, STRIPPING AND BLOCKING WITH COUNTERSUNK, CONCEALED W.YB FASTENERS AND BLIND NAILING AS REWIRED FOR A COMPLETE INSTALLATION. a 11G tiSWE3 = �' _ c = § I X s R m 5. SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK. gag 5 g � e 3 E g 3 I .N11 s iMeWe0 gin M 6. INSTALL ARCHITECTURAL WOODWORK UNDER SUPERVISION OF FACTORY -TRAINED a E a a: c g 3 m g 81=,N+ : s MECHANICS. r N M M 7. ATTACH ARCHITECTURAL WOODWORK SECURELY IN PLACE WITH UNIFORM JOINTS m PROVIDING FOR THERMAL AND BUILDING MOVEMENTS, O a 0 M 5. ACCEPTABLE TOLERANCES: A VARIATION FROM TRUE POSITION: MAXIMUM 1/16' AT ANY qe V) O1 a POSITION AND MAXIMUM I18' IN ANY 10'-O' LENGTH. T cn G. ADJOINING SURFACES OF SAME MATERIAL: NO VARIATION PERMITTED. V DI�SION07 - THERMAL PROTECTION - THERMAl�D�18TURE PROTECTION r N r BECTMIM 072100 - THERMAL NRMATION 0 Y WOW A. GENERAL: PROVIDE THERMAL INSULATION WITH ACCESSORIES AS REQUIRED FOR COMPLETE a W 1. INSULATION INTEGRAL WITH ROOFING REPAIRS IS PROVIDED WITH ROOFING, AND c ACOUSTICAL INSULATION 15 PROVIDED WITH GYPSUM BOARD ASSEMBLIES. O O W � R B. THERMAL BATT INSULATION: LUMENS CORNING/FS-25, USG/TINERMAFIBER F525, OR JOHNS f ro v Z "' MANVILLE/FSK-25; FOIL FACED VAPOR RETARDED FACED, VAPOR RETARDED TOWARD d W INSIDE. THICKNE55/R-VALUE: AS INDICATED ON DRAWINGS. � J t 0 N C. ACCESSORIES: PROVIDE TAPE OR PENETRATION ANCOR$ WHERE REQUIRED TO ENSURE p o N PERMANENT INSTALLATION. 0 DO Q D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. O p � \0 SECTION 072400 - EXTERIOR INSULATION FINISH SYSTEM M m � w Nil LU w 4 A. GENERAL :.i m 1.01 SECTION INCLUDES E ¢ m I. MATERIALS AND INSTALLATION OF EIF5. o Ca m 1.02 RELATED SECTIONS � o M � V "h I. SECTION OMIO: BUILDING INSULATION = = IJJ } is 2. SECTION 07590: ROOF REPAIRS o L ^ � g o W a 3. SECTION 076WE FLASHING AND SHEET METAL M r 0 w } rc 4. SECTION 07900: JOINT SEALERS w Q O W W QO)F d 5. SECTION MOO: ALUMINUM FRAMED STOREFRONTS f w6�U b. SECT -ION OBB00: GLAZING = MM J a 5 Q t W o 7. SECTION 09260: GYPSUM BOARD ASSEMBLIES a W U to U N o 1.03 DESIGN REQUIREMENTS REVISIONS: 1. WIND LOAD: DESIGN FOR MAXIMUM ALLOWABLE SYSTEM DEFLECTING, NORMAL TO ecD aE By DATE THE PLANE OF THE WALL, OF V240. DESIGN FOR WIND LOAD IN CONFORMANCE _. WITH CODE REQUIREMENTS. 2. MOISTURE CONTROL: PREVENT THE ACCUMULATION OF WATER BEHIND THE EIF SYSTEM, EITHER BY CONDENSATION OR LEAKAGE THROUGH THE WALL CONSTRUCTION, IN THE DESIGN AND DETAILING OF THE WALL ASSEMBLY. a. PROVIDE FLASHING TO DIRECT WATER TO THE EXTERIOR WHERE IT IS LIKELY TO PENETRATE COMPONENTS IN THE WALL ASSEMBLY, INCLUDING, ABOVE WINDOW AND DOOR HEADS, BENEATH WINDOW AND DOOR SILLS, AT ROOF/WALL INTERSECTIONS, DECKS, ABUTMENTS OF LOWER WALLS WITH HIGHER WALLS, ABOVE PROJECTING FEATURES, AND AT THE BASE OF THE WALL. b. VAPOR DIFFUSION AND CONDENSATION: PERFORM A DEW POINT ANALYSIS OF THE WALL ASSEMBLY TO DETERMINE THE POTENTIAL FOR ACCUMULATION OF MOISTURE IN THE WALL ASSEMBLY AS A RESULT OF WATER VAPOR DATE ISSUED: 05/31 /2019 DIFFUSION AND CONDENSATION. ADJUST INSULATION THICKNESS AND/OR DESIGNED BY: JH OTHER WALL ASSEMBLY COMPONENTS ACCORDINGLY TO MINIMIZE THE RI5K OF DRAWN BY: YL CONDENSATION. AVOID THE USE OF VAPOR RETARDERS ON THE INTERIOR CHECKED BY: YL SIDE OF THE WALL IN WARM, HUMID CLIMATES. 3. IMPACT RESISTANCE SPECIFICATIONS a. PROVIDE ULTRA -HIGH IMPACT RESISTANCE TO A MINIMUM HEIGHT OF 6'-0' (1.8 M) ABOVE FINISHED GRADE AT ALL AREAS ACCESSIBLE TO PEDESTRIAN TRAFFIC AND OTHER AREAS EXPOSED TO ABNORMAL STRESS OR IMPACT 4. JOINTS DRAWING NUMBER: a. DESIGN MINIMUM 3/4' WIDE EXPANSION JOINTS IN THE EIFS WHERE THEY EXIST IN THE SUBSTRATE OR SUPPORTING CONSTRUCTION, WHERE THE EIFS ADJOINS D1551MILAR CONSTRUCTION OR MATERIALS, AT CHANGES IN BUILDING HEIGHT, AND AT FLOOR LINES IN MULTI -LEVEL WOOD FRAME CONSTRUCTION. A15ol