HomeMy WebLinkAboutA15.2 SpecsI MINIMUM 1/2' WIDE SEALANT JOINTS AT ALL PENETRATIONS THROUGH THE
EIFS (WINDOW5, DOORS, ETC.).
C. INSTALL BACKER ROD AND SEALANT THAT HAS BEEN EVALUATED IN
ACCORDANCE WITH ASTM C 1352, 'TEST METHOD FOR DETERMINING TENSILE
ADHESION PROPERTIES OF SEALANTS WHEN USED IN EXTERIOR INSULATION
AND FINISH SYSTEMS (EIFS) JOINTS,' AND THAT MEETS MINIMUM SOIL
ELONGATION AFTER CONDITIONING.
d. DESIGN JOINTS WITH SECONDARY MOISTURE PROTECTION AND DRAIN JOINTS TO
THE EXTERIOR
I. TRIM, PROJECTING ARCHITECTURAL FEATURES AND REVEALS
a. ALL TRIM AND PROJECTING ARCHITECTURAL FEATURES MUST HAVE A
MINIMUM 12 [271 SLOPE ALONG THEIR TOP SURFACE. ALL HORIZONTAL
REVEALS MUST HAVE A MINIMUM 12 C27'3 SLOPE ALONG THEIR BOTTOM
SURFACE.
6. FIRE PROTECTION
a. DO NO USE FOAM PLASTIC IN EXCE55 OF 4 ' THICK. WHERE A
FIRE -RESISTANCE RATING IS REQUIRED BY CODE USE EIFS OVER RATED
ASSEMBLY.
1.04 SUBMITTALS
I. SAMPLES FOR APPROVAL AS DIRECTED BY LSDOC PROJECT MANAGER.
2. PREPARE AND SUBMIT PROJECT -SPECIFIC DETAILS (WHEN REQUIRED BY CONTRACT
DOCUMENTS).
1.05 QUALITY ASSURANCE
I. MANUFACTURER REQUIREMENTS
a. MEMBER IN GOOD STANDING OF THE EIPS INDUSTRY MEMBERS ASSOCIATION
(EIMA).
b. SYSTEM MANUFACTURER FOR A MINIMUM OF TWENTY (20) YEARS.
MANUFACTURING FACILITIES ISO 9002 CERTIFIED.
C. MANUFACTURER'S WALL ASSEMBLY LISTED IN GYPSUM ASSOCIATION FIRE
RESISTANCE DESIGN MANUAL.
2. CONTRACTOR REQUIREMENTS
o. ENGAGED IN APPLICATION OF EIFS FOR A MINIMUM OF THREE (8) YEARS.
b. KNOWLEDGEABLE IN THE PROPER USE AND HANDLING OF STO MATERIALS AND
LISTED BY STO AS HAVING ATTENDED STO EIFS CONTINUING EDUCATION.
c. EMPLOY SKILLED MECHANICS WHO ARE EXPERIENCED AND KNOWLEDGEABLE IN
EIFS APPLICATION, AND FAMILIAR WITH THE REQUIREMENTS OF THE SPECIFIED
WORK.
d. SUCCESSFUL COMPLETION OF MINIMUM OF THREE (3) PROJECTS OF SIMILAR
SIZE AND COMPLEXITY TO THE SPECIFIED PROJECT.
a. PROVIDE THE PROPER EQUIPMENT, MANPOWER AND SUPERVISION ON THE JOB
SITE TO INSTALL THE SYSTEM IN COMPLIANCE WITH STO'S PUBLISHED
SPECIFICATIONS AND DETAILS AND THE PROJECT PLANS AND SPECIFICATIONS.
3. INSULATION BOARD MANUFACTURER REQUIREMENTS
a. RECOGNIZED BY STO AS CAPABLE OF PRODUCING INSULATION BOARD TO
MEET SYSTEM REQUIREMENTS, AND HOLD A VALID LICENSING AGREEMENT
WITH STO.
b. LISTED BY AN APPROVED AGENCY.
C. LABEL INSULATION BOARD WITH INFORMATION REQUIRED BY STO, THE
APPROVED LISTING AGENCY AND THE APPLICABLE BUILDING CODE.
1.06 DELIVERY, STORAGE AND HANDLING
I. DELIVER ALL MATERIALS IN THEIR ORIGINAL 5EAL.ED CONTAINERS BEARING
MANUFACTURER'S NAME AND IDENTIFICATION OF PRODUCT.
2. PROTECT COATINGS (AIL PRODUCTS) FROM FREEZING AND TEMPERATURES IN
EXCESS OF 90'F STORE AWAY FROM DIRECT SUNLIGHT.
3. PROTECT PORTLAND CEMENT BASED MATERIALS (BAG PRODUCTS) FROM MOISTURE
AND HUMIDITY. STORE UNDER COVER OFF THE GROUND IN A DRY LOCATION.
1.07 PROJECT/SITE CONDITIONS
1. MAINTAIN AMBIENT AND SURFACE TEMPERATURES ABOVE 40T DURING APPLICATION
AND DRYING PERIOD, MINIMUM 24 HOURS AFTER APPLICATION OF EIFS.
2. PROVIDE SUPPLEMENTARY HEAT FOR INSTALLATION IN TEMPERATURES LESS THAN
RIOT (4'C).
B. PROVIDE PROTECTION OF SURROUNDING AREAS AND ADJACENT SURFACES FROM
APPLICATION OF MATERIALS,
1.08 COORDINATION/SCWEDULING
I. PROVIDE SITE GRADING SUCH THAT EIFS TERMINATES ABOVE FINISHED GRADE A
MINIMUM OF 8' (203 MM) OR AS REQUIRED BY CODE.
2. PROVIDE PROTECTION OF ROUGH OPENIW5 BEFORE INSTALLING WINDOWS, DOORS,
AND OTHER PENETRATIONS THROUGH THE WALL AND PROVIDE SILL FLASHING.
3. INSTALL WINDOW AND DOOR HEAD FLASHING IMMEDIATELY AFTER WINDOWS AND
DOORS ARE INSTALLED.
4. INSTALL DIVERTER FLASHING WHEREVER WATER CAN ENTER THE WALL ASSEMBLY
TO DIRECT WATER TO THE EXTERIOR.
S. INSTALL COPINGS AND SEALANT IMMEDIATELY AFTER INSTALLATION OF THE ELF
SYSTEM AND WHEN EIFS COATINGS ARE DRY.
6. ATTACH PENETRATIONS THROUGH EIFS TO STRUCTURAL SUPPORT AND PROVIDE
WATER TIGHT SEAL AT PENETRATIONS.
1.09 WARRANTY
I. PROVIDE MANUFACTURER'S STANDARD LABOR AND MATERIAL WARRANTY.
A. PRODUCTS
2.01 MANUFACTURERS
I. PROVIDE EIF SYSTEM AND ACCESSORIES FROM SINGLE SOURCE MANUFACTURER OR
APPROVED SUPPLIER.
2. THE FOLLOWING ARE ACCEPTABLE MANUFACTURERS:
a. STO CORP. -EIF SYSTEM
b. PLASTIC COMPONENTS, INC - ACCESSORIES
3. INDUSTRY STANDARD SYSTEM:
a. INTERIOR: STOUT CLASSIC
b. EXTERIOR: STO CLASSIC NEXT 12 YEAR WARRANTY
2.02 SURFACE PREPARATION
1. LEVELER: STO LEVELER - ONE-COMPCAIENT, POLYMER MODIFIED, CEMENT BASED
LEVELER WITH FIBER REINFORCEMENT IF REQUIRED IN UNEVEN RESTORATION SURFACE.
2.03 ADHESIVE
I. CEMENTITIOUS ADHESIVE
a. STO BTS PLUS -ONE -COMPONENT, POLYMER -MODIFIED, CEMENT BASED HIGH BUILD
ADHESIVE.
2. NON-CEMENI ITIWS ADHESIVE
a. STO DISPERSION ADHESIVE-NON-CEMENTITIOU5, ACRYLIC BASED ADHESIVE
2.04 INSULATION BOARD
I. NOMINAL 1.0 LB/FT3 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD IN COMPLIANCE
WITH ASTM C 578 TYPE I REQUIREMENTS, AND EIMA GUIDELINE SPECIFICATION FOR
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD. USE NEWLY PACKAGED INSULATION
BOARD ONLY.
2.05 BASE COAT
I. CEMENTITIOUS BASE COAT5
a. STO 8T5 PLUS -ONE -COMPONENT POLYMER MODIFIED CEMENT BASED HIGH BUILD
BASE COAT WITH LESS THAN 33 3 PORTLAND CEMENT CONTENT BY WEIGHT AND
CAPABLE OF ACHIEVING MINIMUM 1/16' (1.6 MM) THICKNESS IN ONE PASS.
2. NONCEMENTITIOU5 BASE COAT
a. STO RFP-ONE COMPONENT READY MIXED NON-CEMENTITIOUS, FIBER REINFORCED
ACRYLIC BASE COAT.
3. WATERPROOF BASE COAT
a. STO FLEXYL - TWO COMPONENT FIBER REINFORCED ACRYLIC BASED WATERPROOF
BASE COAT MIXED WITH PORTLAND CEMENT.
9 M RGINF 1D _ wre ra
RELEASED FOR CONSTRUCTION 6'-O')
'YD2 (390 G/M2), OVER 5TO ARMOR MAT - NOMINAL
Subject to compliance with all regulations N WEAVE GLASS FIBER FABRIC WITH ALKALINE
of State and local Codes MPATIBILITY WITH STO MATERIALS.
City of Carmel (�
�51AGII w�IN) :
2. INTERMEDIATE MESH (ABOVE 6'-0')
b. STO INTERMEDIATE MESH: NOMINAL II OZ./YD2 INTERWOVEN, OPEN WEAVE GLA55
FIBER FABRIC WITH ALKALINE RESISTANT COATING FOR COMPATIBILITY WITH STO
MATERIALS
0 a 4 P2
I. STO PRIMER ACRYLIC BASED TINTED PRIMER.
2.08 FINISH COAT
I. STOLIT .76 FREEFORM ACRYLIC BASED TEXTURED WALL COATING WITH GRADED
MARBLE AGGREGATE. CUSTOM FINISH AS INDICATED ON STOREFRONT DRAWINGS (AOB
SERIES).
2.09 MIXED INGREDIENTS
I. WATER: CLEAN AND POTABLE.
2. PORTLAND CEMENT: TYPE I IN CONFORMANCE WITH A5TM C 150.
2.10 ACCESSORIES
I. STARTER TRACK RIGID PVC (POLYVINYL CHLORIDE) PLASTIC TRACK PART NO. 5TDE AS
FURNISHED BY PLASTIC COMPONENTS, INC., 9051 NW 97TH TERRACE, MIAMI, FLORIDA
3317E (I-BOO-327-7077).
2.11 MIXING
I. STO PLEX W: ADD WATER AS DIRECTED ON LABELING.
2. STO LEVELER: MIX RATIO WITH WATER 6-7 QUARTS (5.7-6.6 L) OF CLEAN WATER PER
60 POUND (27.3 KG)BAG OF STO LEVELER. POUR WATER INTO A CLEAN MIXING PAIL.
L. ADD $TO LEVELER, MIX TO A UNIFORM CONSISTENCY AND ALLOW TO SET FOR
APPROXIMATELY 5 MINUTES. ADJUST MIX IF NECESSARY WITH ADDITIONAL STO LEVELER
OR WATER AND REMIX TO A UNIFORM TROWEL CONSISTENCY. AVOID RETEMPERING. KEEP
MIX RATIO CONSISTENT. DO NO EXCEED MAXIMUM WATER AMOUNT IN MIX RATIO,
3. STO RFP: MIX WITH A CLEAN, RUST -FREE HIGH SPEED MIXER TO A UNIFORM
CONSISTENCY.
4. STO FLEXYL: MIX RATIO WITH PORTLAND CEMENT: U1 RATIO BY WEIGHT. FOUR STO
FLEXYL INTO A CLEAN MIXING PAIL. ADD PORTLAND CEMENT, MIX TO A UNIFORM
CONSISTENCY AND ALLOW TO SET FOR APPROXIMATELY FIVE MINUTES. ADJUST MIX IF
NECESSARY WITH ADDITIONAL STO FLEXYL AND REMIX TO A UNIFORM TROWEL
CONSISTENCY. AVOID RETEMPERING. KEEP MIX RATIO CONSISTENT.
S. STO PRIMER: MIX WITH A CLEAN, RUST -FREE HIGH SPEED MIXER TO A UNIFORM
CONSISTENCY.
6. STOUT: MIX WITH A CLEAN, RUST -FREE HIGH SPEED MIXER TO A UNIFORM
CONSISTENCY. A SMALL AMOUNT OF WATER MAY BE ADDED TO ADJUST WORKABILITY.
LIMIT ADDITION OF WATER TO AMOUNT NEEDED TO ACHIEVE THE FINISH TEXTURE.
7, MIX ONLY AS MUCH MATERIAL AS CAN READILY BE USED.
S. DO NOT USE ANTI -FREEZE COMPOUNDS OR OTHER ADDITIVES.
C. EXECUTION
3.01 ACCEPTABLE INSTALLERS
I. PREQUALIFY UNDER QUALITY ASSURANCE REQUIREMENTS OF THIS SPECIFICATION
(SECTION 1.07D).
3.02 EXAMINATION
I. INSPECT SURFACES FOR:
a. CONTAMINATION: ALGAE, CHALKINESS, DIRT, DUST, EFFLORESCENCE, FORM OIL,
FUNGUS, GREASE, LAITANCE, MILDEW OR OTHER FOREIGN SUBSTANCES.
b. SURFACE ABSORPTION AND CHALKINESS.
C. CRACKS: MEASURE CRACK WIDTH AND RECORD LOCATION OF CRACKS.
d. DAMAGE AND DETERIORATION.
a. MOISTURE CONTENT AND MOISTURE DAMAGE: USE A MOISTURE METER TO
DETERMINE IF THE SURFACE IS DRY ENOUGH TO RECEIVE THE EIFS AND RECORD
ANY AREAS OF MOISTURE DAMAGE.
f. COMPLIANCE WITH SPECIFICATION TOLERANCES: RECORD AREAS THAT ARE OUT OF
TOLERANCE (GREATER THAN 1/4' IN 56-0' DEVIATION IN PLANE).
2. INSPECT SHEATHING APPLICATION FOR COMPLIANCE WITH APPLICABLE REQUIREMENT:
a. EXTERIOR GYPSUM SHEATHING: GA-253
b. EXTERIOR GRADE AND EXPOSURE I WOOD BASED SHEATHING: APA ENGINEERED
WOOD ASSOCIATION E 30.
C. GLASS MAT FACED GYPSUM SHEATHING: GEORGIA PACIFIC PUBLICATION 101514
d. CEMENTITIOUS SHEATHING: CONSULT MANUFACTURER'S PUBLISHED
RECOMMENDATIONS
3. REPORT DEVIATIONS FROM THE REQUIREMENTS OF PROJECT SPECIFICATIONS OR OTHER
CONDITIONS THAT MIGHT ADVERSELY AFFECT THE EIFS INSTALLATION TO THE GENERAL
CONTRACTOR. DO NOT START WORK UNTIL DEVIATIONS ARE CORRECTED,
3.03 SURFACE PREPARATION
1. REMOVE SURFACE CONTAMINANT5 ON CONCRETE AND CONCRETE MASONRY SURFACES
(REFER TO A5TM D 4258 AND D 4261).
2. APPLY CONDITIONER BY SPRAYER OR ROLLER TO CHALKING OR EXCE551VELY
ABSORPTIVE SURFACES.
3. REPLACE WEATHER -DAMAGED SHEATHING AND REPAIR DAMAGED OR CRACKED
SURFACES.
4. LEVEL SURFACES TO COMPLY WITH REQUIRED TOLERANCES.
5.04 INSTALLATION
I. INSTALL EIFS IN COMPLIANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS (SEE
ADDENDUM).
3.05 PROTECTION
I. PROVIDE PROTECTION OF INSTALLED MATERIALS FROM WATER INFILTRATION INTO OR
BEHIND THEM.
2. PROVIDE PROTECTION OF INSTALLED MATERIALS FROM DUST, DIRT, PRECIPITATION,
FREEZING AND CONTINUOUS HIGH HUMIDITY UNTIL THEY ARE FULLY DRY.
SECTION 075900 - ROOF REPAIRS
1. GENERAL: REPAIR EXISTING ROOFING SYSTEM AS REQUIRED FOR NEW CONSTRUCTION,
WITH COMPONENTS AND ACCESSORIES AS REQUIRED FOR COMPLETE WEATHER TIGHT
INSTALLATION.
2. STANDARDS: CONFORM TO NATIONAL ROOFING CONTRACTOR'S ASSOCIATION ROOFING
AND WATERPROOFING MANUAL, 4TH OR 5TH EDITION.
3. WARRANTY: MAINTAIN ALL EXISTING WARRANTIES. PROVIDE FOR CORRECTING FAILURE
OF ROOF REPAIRS TO RESIST PENETRATION OF WATER AND DAMAGE FROM WIND;
WARRANTY PERIOD OF TWO YEARS,
4. ROOFING SYSTEM: MATCH EXISTING ROOFING, NO SUBSTITUTIONS PERMITTED; PROVIDE
MATERIALS CAPABLE OF MAINTAINING EXISTING WARRANTIES; CONFORM TO
REQUIREMENTS OF NRCA ROOFING MANUAL.
0. SYSTEM: PROVIDE COMPLETE SYSTEM WITH ACCESSORIES AS REQUIRED FOR
REPAIRS, INCLUDING INSULATION WHERE EXISTING ROOFING IS INSULATED.
5. ROOF SYSTEM REPAIRS: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND
INSTRUCTIONS AND NRCA RECOMMENDATIONS FOR ROOF TYPE SPECIFIED.
b. REMOVE EXISTING ROOFING AS REQUIRED FOR PROJECT; REMOVE ONLY AS MUCH
ROOFING AS CAN BE REPLACED IN SAME DAY UNLESS OTHERWISE APPROVED IN
ADVANCE BY OWNER'S PROJECT MANAGER.
C. INSPECT SUBSTRATES AND ROOF DECK TO ENSURE SUBSTRATES AND DECK ARE
CLEAN AND SMOOTH, FREE OF DEPRESSIONS, WAVES OR PROJECTS, AND ARE
PROPERLY SLOPE TO DRAINS, VALLEY, OR EAVES.
d. INSULATION APPLICATION: ATTACH INSULATION IN ACCORDANCE WITH INSULATION
MANUFACTURER'S INSTRUCTIONS AND NRCA RECOMMENDATIONS FOR INSTALLATION
OF INSULATION ON DECK INVOLVED.
a. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF
COMPOSITE TYPE BASE, WALL AND FILED FLASHING.
It. COORDINATE METAL FLASHING AND COUNTERFLASHING.
g. COORDINATE INSTALLATION OF ROOF DRAINS AND RELATED FLASHING.
h. MOP IN AND SEAL FLASHING AND FLANGES OF ITEMS PROJECTING THROUGH
MEMBRANE.
SECTION 07WDO - FLASHING AND SHEET NETAL
A. GENERAL: PROVIDE FLASHING AND SHEET METAL, REGLETS, AND ACCESSORIES AS
REQUIRED FOR ROOF REPAIRS AS REQUIRED FOR COMPLETE, WEATHER TIGHT INSTALLATION.
B. STANDARDS: CONFORM TO SMACNA 'ARCHITECTURAL SHEET METAL MANUAL' REQUIREMENTS I J. PREPARATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT
FOR FLASHING AND SHEET METAL.
SEALER, AND PRIME OR SEAL JOINT SURFACES AS RECOMMENDED BY MANUFACTURER.
C. DESIGN REQUIREMENTS: ALLOW FOR MOVEMENT OF COMPONENTS WITHOUT CAUSING
K.
INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND
BUCKLING, FAILURE OF JOINT SEALS, UNDUE STRESS ON FASTENERS OR OTHER
A5TM CII93.
DETRIMENTAL EFFECTS, WHEN SUBJECT TO 100 YEAR SEASONAL TEMPERATURE RANGES.
1. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE DEP051TED
IN UNIFORM, CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS, WITH COMPLETE
D. SUBMITTALS: FURNISH PRODUCT DATA FOR MANUFACTURED PRODUCTS.
'WETTING' OF BOND SURFACES.
E. WARRANTY: MAINTAIN ALL EXISTING WARRANTIES. CORRECT FAILURE OF METAL FLASHING
SYSTEM TO RESIST PENETRATION OF WATER AND DAMAGE FROM WIND, WARRANTY PERIOD
DIVISION 08 - DOORS AND WINDOWS
TWO YEARS.
F. FLASHING AND SHEET METAL: MATCH EXISTING, BUT HOT LESS THAT FOLLOWING.
SECTION 001000 - METAL DOORS AND FRAMES
I. GALVANIZED METAL FLASHING: ASTM A526 GALVANIZED STEEL WITH MINIMUM 0.02 AND
A.
GENERAL: PROVIDE STEEL DOORS AND FRAMES AND ACCESSORIES AS REQUIRED FOR
WITH MINIMUM Coll GALVANIZED COATING; MINIMUM 24 GAGE.
COMPLETE INSTALLATION; COORDINATE WITH SECTION 06700 - HARDWARE.
2. PREFINISNED METAL FLASHING: 24 GAGE GALVANIZED STEEL WITH FACTORY FINISHED
B.
STANDARDS: COMPLY WITH STEEL DOOR INSTITUTE 'STANDARD STEEL DOORS AND
KYNAR WO TYPE FLUROPOLYMER COATING AND STRIPPABLE PROTECTIVE FILM; COLOR
FRAMES OR NAAMM HOLLOW METAL MANUFACTURER'S ASSOCIATION 'HOLLOW METAL
AS SELECTED FROM MANUFACTURERS FULL RANGE OF COLORS.
MANUAL.'
3. ALUMINUM FLASHING: ASTM B209, ALLOY AS REQUIRED TO MATCH FINISH SPECIFIED FOR
1. FIRE RATED STANDARDS: FURNISH MATERIALS TESTED, LABELED AND INSPECTED
OTHER ALUMINUM COMPONENTS; THICKNESS MINIMUM 0.050' AT FLASHING.
BY UL, WARNOCK HERESY, OR TESTING AGENCY ACCEPTABLE TO APPLICABLE
AUTHORITIES.
4. STAINLESS STEEL SHEET METAL: ASTM A666, 2D ANNEALED FINISH, SOFT TEMPER
EXCEPT WHERE HARDER TEMPER IS REQUIRED FOR FORMING OR PERFORMANCE; 0.015'
C
SUBMITTALS: SUBMIT PRODUCT DATA.
(26 GAGE) TYPICAL.
D.
MANUFACTURERS: AMWELD, CECO, PIONEER, OR APPROVED EQUAL.
5. COPPER SHEET METAL: ASTM 5370, COLD ROLLED 16 OZ. (0.0216') THICK; SOFT TEMPER
E.
HOLLOW METAL DOORS: FLUSH HOLLOW METAL DOORS FULL FLUSH TYPE; SDI MODEL I,
WHERE REQUIRED FOR FORMING.
NAAMM TYPE B FULL FLUSH WITH UNFILLED EDGE; CLOSE TOP AT EXTERIOR DOORS.
G. REGLETS: FRY/SFRINGLOK OR MM SYSTERMS/SNAP-TITS REGLETS, FABRICATE OF SAME
1. CORE' PROVIDE STEEL STIFFENED CORE; INSULATED AT EXTERIOR DOORS.
METAL AS ADJACENT FLASHING AND 514EET METAL.
2. GAGE: PROVIDE MINIMUM 18 GAGE AT INTERIOR DOORS, MINIMUM 16 GAGE AT
EXTERIOR DOORS.
W. METAL TO METAL SEALANT: BUTYL TYPE: NON -STAINING, NON -CORROSIVE, NON -SHRINKING,
NON -SAGGING, ULTRAVIOLET AND OZONE RESISTANT.
F.
PRESSED STEEL (HOLLOW METAL) FRAMES. MINIMUM 16 GAGE KNOCKDOWN
(FIELD -ASSEMBLED) FRAMES.
I. INSTALLATION: COMPLY WITH SMACNA MANUAL.
I. INSTALL METAL FLASHING AND SHEET METAL IN ACCORDANCE WITH 5MACNA
G.
FIRE RATED UNITS: CONFORM TO NFPA SO; PROVIDE UL OR WARNOCK HERESY LABELED
ARCHITECTURAL SHEET METAL MANUAL; TIGHT IN PLACE, WITH CORNER SQUARE,
DOORS AND FRAMES AS REQUIRED.
SURFACES TRUE AND STRAIGHT IN PLANES, AND LINES ACCURATE TO PROFILES AS
INDICATED ON DRAWINGS.
H.
ACCESSORIES: PROVIDE DOOR SILENCERS, ANCHORS, AND ACCESSORIES.
2. INSTALL SEALANT WHERE REQUIRED TO PREVENT DIRECT WEATHER PENETRATION
I.
FABRICATION: CONFORM TO REQUIREMENTS OF SDI OR NAAMM.
3. COMPLETED SHALL BE FREE OF RATTLES, NOSE WE TO THERMAL AND
AND
I. DOOR SILENCERS: PLACE MINIMUM THREE SINGLE BUMPERS ON SINGLE DOOR
AIR MOVEMENT, AND WIND WHISTLES.
T, WIND
FRAME SPACE EQUALLY ALONG STRIKE JAMBS; PLACE TWO SINGLE BUMPERS
ON DOUBLE DOOR FRAME HEADS.
J
FINISH: PRIME PAINT INTERIOR UNITS GALVANIZE AND PRIME PAINT EXTERIOR UNITS
SECTION 078100 - APPLIED FIREPROOFING
A. GENERAL: PATCH EXISTING FIREPROOFING AS REWIRED BY APPLICABLE CODES FOR
CONSTRUCTION TYPE; NO ASBESTOS PERMITTED.
B. DESIGN REQUIREMENTS: PROVIDE MATERIALS CAPABLE OF ATTAINING FIRE RATINGS AS
REQUIRED FOR TYPE 1, FIRE RESISTIVE CONSTRUCTION.
C. PERFORMANCE REQUIREMENTS: PROVIDE MATERIALS LISTED BY UL OR INDEPENDENT
TESTING AND INSPECTION AGENCY ACCEPTABLE TO APPLICABLE AUTHORITIES.
I. FIRE RESISTANCE RATINGS: COMPLY WITH REQUIRED RATINGS BASED
2. SURFACE BURNING CNARACTERI5TIC5. MAXIMUM 25 FLAME SPREAD AND 25 SMOKE
DENSITY WHEN TESTED IN ACCORDANCE WITH ASTM E84.
D. CERTIFICATE: SUBMIT MANUFACTURER CERTIFICATION INDICATING APPLICATOR
ACCEPTABILITY AND MATERIAL COMPLACENT WITH APPLICABLE CODES AND CONTRACT
DOCUMENTS.
I. CERTIFICATION SHALL INDICATE NEW MATERIALS USED TO PATCH EXISTING FIREPRWFEC
MEMBERS AT NEW AND EXISTING WORK ARE COMPATIBLE WITH EXISTING FIREPROOFING
MATERIALS AND MEET ALL PERFORMANCE REQUIREMENTS.
E. QUALIFICATION OF APPLICATOR: FIRM ACCEPTABLE TO MANUFACTURER OF FIREPROOFING
MATERIALS WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE ON PROJECTS OF SIMILAR
SCOPE.
F. MANUFACTURERS/PRODUCTS: MATCH EXISTING BUT NOT LESS THAN W.R. GRACE/MONOKOTE
OR ALBI MANUFACTURING DIVISION 5TANCHEM/DURASPRAY.
G. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST
RESULTS AS REQUIRED TO PROVIDE REQUIRED FIRE RATINGS.
1. PROTECT ADJACENT SURFACES AND EQUIPMENT FROM DAMAGE BY OVER SPRAY,
FALLOUT, AND DUSTING; MASK ADJACENT WORK AS REQUIRED. CLOSE OFF AND SEAL
DUCT WORK IN AREAS WHERE FIREPROOFING IS BEING APPLIED.
2. CLEAN SUBSTRATE OF DIRT, DUST, GREASE, OIL, LOOSE MATERIAL, PAINTS, PRIMERS,
AND OTHER MATTER WHICH AFFECTS BOND OF SPRAYED FIREPROOFING.
3. APPLY FIREPROOFING IN SUFFICIENT THICKNESS AND DENSITY TO ACHIEVE REQUIRED
FIRE RATINGS.
4. APPLY FIREPROOFING OVER SUBSTRATE, BUILDING TO REQUIRED THICKNESS WITH AS
MANY PASSES OR STAGES NECESSARY TO COVER WITH MONOLITHIC BLANKET OF
UNIFORM DENSITY AND TEXTURE.
SECTION 078400 - FILE STOPPING
A. GENERAL: PROVIDE PENETRATION -TYPE FIRE STOPPING FOR TIME -RATED FLOOR, WALL AND
PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE AND HOT
GASES.
B. CODES: CONFORM TO APPLICABLE CODE REQUIREMENTS FOR BOTH F AND T RATINGS.
C. STANDARDS: PASS ASTM SEW THROUGH -PENETRATION FIRE STOPS, ASTM E119 FIRE
TESTS AND ASTM E84 FLAME SPREAD/SMOKE CONSTRICTION MAXIMUM 25/25.
D. SUBMITTALS: FURNISH SHOP DRAWINGS, PRODUCT DATA, AND CERTIFICATES OF
COMPLIANCE WITH CONTRACT DOCUMENTS, AND APPLICABLE CODES.
E. MANUFACTURERS: 3M/FIRE BARRIER, STI/SPECSFAL OR PENSIL, OR HILTI/FIRESTOP
SYSTEMS.
F. GENERAL: CHOOSE PRODUCTS AND METHODS MEETING APPLICABLE CODES AND
SPECIFICATION REQUIREMENTS FOR EACH FIRE STOPPING APPLICATION, SUBJECT TO
OWNERS PROJECT MANAGER'S ACCEPTANCE.
G. FIRE STOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME -RATED
FLOOR, WALL, AND PARTITION ASSEMBLIES CAPABLE OF PREVENT PASSAGE OF
FLAME, SMOKE, AND HOT GASES.
I. PENETRATION TEST: FURNISH MATERIALS PASSING ASTM E514 FOR PENETRATION FIRE
STOPPING INDICATING MAINTENANCE OF TIME -RATED ADJACENT ASSEMBLIES.
2. FIRE STOPPING: MAINTAIN FIRE RATING OF ASSEMBLY IN WHICH FIRE STOPPING IS
INSTALLED, SUCH AS FLOOR, PARTITION, OR WALL, IN ACCORDANCE WITH ASTM E119
TEST.
N. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST
RESULTS AS REQUIRED TO PROVIDE REQUIRED FIRE RATINGS.
I. FIELD INSPECTIONS: MAINTAIN COPY OF MANUFACTURER'S INSTALLATION INSTRUCTIONS
AND RECOMMENDATIONS AT EACH WORK AREA..
SECTION 079200 - JOINT SEALERS
A. GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDED ELSEWHERE;
TYPE SUITABLE FOR APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR
COMPLETE INSTALLATION.
B. INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE ON
PROJECTS OF SIMILAR TYPE AND SIZE, USING SPECIFIED PRODUCTS.
C. WARRANTY: REPAIR OR REPLACE JOINT SEALERS WHICH FAIL TO PERFORM AS INTENDED
BECAUSE OF LEAKING, CRUMBLING, HARDENING, SHRINKAGE, BLEEDING, SAGGING, STAINING
AND LOSES OF ADHESION; WARRANTY PERIOD TWO YEARS.
D. EXTERIOR NON -TRAFFIC JOINTS: GE/51LPRUF, DOWMIO-7%, OR PECORA/854, LOW MODULES
SILICONE SEALANT.
E. TRAFFIC BEARING JOINTS: MAMECONULKEM 245, OR PECORA/NR-2O0 UREXPAN,
MULTI -COMPONENT POLYURETHANE, SELF -LEVELING JOINT SEALER.
F. MILDEW -RESISTANT SANITARY SEALANTS: GE/SANITARY SEALANT, DOW/BATHTUB CAULK,
OR PECORA/B63 0345 WHITEY PROVIDE AT INTERIOR AREAS WHERE SEALANT WILL BE
EXPOSED TO WATER.
G. GENERAL INTERIOR JOINT SEALER: PECORA/AC-20 OR 5ONNEBORN/SONOLAC, ACRYLIC OR
LATEX EMULSION.
H. MISCELLANEOUS MATERIALS: PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE,
AND SEALANT BACKER RODS AS RECOMMENDED BY SEALANT MANUFACTURER FOR
APPLICATIONS INDICATED.
I. OVERSIZE BACKER ROD MINIMUM 302 TO 50% OF JOINT OPENING.
I. COLORS: AS INDICATED OR AS SELECTED BY OWNER'S PROJECT MANAGER FROM
MANUFACTURER'S FULL RANGER OF COLORS.
MINIMUM A60 GALVANIZING; CLEAN, DEGREASE AND FACTORY PRIME PAINT.
K. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND EITHER SDI OR
NAAMM STANDARDS.
I. INSTALL FIRE RATED UNITS IN CONFORMANCE WITH FIRE LABEL REQUIREMENTS
AND NFPA W.
2. INSTALL DOORS AND FRAMES PLUMB AND SQUARE, AND WITH MAXIMUM DIAGONAL
DISTORTION OF 1/10.
OEM= MM - WOOD DOORS
A. GENERAL: INSTALL WOOD DOORS AND WOOD DOOR FRAMES AS REQUIRED FOR COMPLETE
INSTALLATION; COORDINATE WITH HARDWARE IN SECTION 08700.
B. STANDARDS: COMPLY WITH NATICNAL WOOD WINDOW AND DOOR ASSOCIATION (NWWDA)
INDUSTRY STANDARDS FOR WOOD DOORS.
C. PROJECT CONDITIONS: DO NOT DELIVER OR INSTALL DOORS UNTIL CONDITIONS FOR
TEMPERATURE AND RELATIVE HUMIDITY HAVE BEEN STABILIZED IN ACCORDANCE WITH
REFERENCED STANDARDS REQUIREMENTS APPLICABLE TO PROJECT LOCATION.
D. WARRANTY: PROVIDE FOR REHANGING WOOD DOORS EXHIBITING DEFECTS IN WORKMANSHIP.
WARRANTY PERIOD TWO YEARS.
E. INSTALLATION: INSTALL WOOD DOORS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS AND REFERENCE STANDARDS
PLUMB AND SQUARE, AND WITH MAXIMUM DIAGONAL DISTORTION OF MEN.
F. PROTECTION: PROTECT DOORS AS RECOMMENDED BY DOOR MANUFACTURER TO ENSURE
DOORS ARE WITHOUT DAMAGE AT TIME OF SUBSTANTIAL COMPLETION,
SECTION GUIDO - ACCESS DOORS AND PANELS
A. GENERAL: PROVIDE ACCESS DOORS AS REQUIRED FOR ACCESS TO VALVES AND CONTROLS
LOCATED BEHIND FINISHED WALLS AND CEILINGS NOT OTHERWISE ACCESSIBLE, WITH
ACCESSORIES FOR COMPLETE INSTALLATION.
I. COORDINATE WITH VARIOUS TRADES FOR CONTROLS AND VALVES WHICH MAY BE
CONCEALED.
B. SUBMITTALS: FURNISH PRODUCT DATA FOR EACH TYPE OF ACCESS DOOR AND PANEL.
C. MANUFACTURERS: STEALTH, AVAILABLE THROUGH MDI SUPPLY (568-634-31I AND
SEVERAL OTHER SUPPLIERS; KARP ASSOCIATES INC., MASPETH, N.Y. (718-7S4-2105)
1. SALES AREA (NON -RATED): STEALTH DROP -IN STYLE CEILING ACCESS PANEL
WITH ROUNDED CORNERS. SEE CEILING PLAN FOR SIZES AND LOCATIONS.
2. SALES AREA (RATED): KARP MODEL BKATR PRIME COATED STEEL WITH
STAINLESS STEEL CAM LATCH ON RECESSED DOOR. SEE CEILING PLAN FOR SIZES
AND LOCATIONS.
3. NON -SALES AREA (NON -RATED): KARP MODEL BDSC-21411. PRIME COATED STEEL
WITH STUD LATCH. SEE CEILING PLAN FOR SIZES AND LOCATIONS.
4. 4. NON -SALES AREA (RATED): KARP MODEL OKRP-150FR PRIME COATED STEEL
WITH RING TURN LATCH. SEE CEILING PLAN FOR SIZES AND LOCATIONS.
F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE
REQUIREMENTS FOR FIRE RATINGS.
I. SET FRAMES ACCURATELY IN POSITION AND SECURELY ATTACH TO SUPPORTS
WITH FACE PANEL5 PLUMB OR LEVEL IN RELATION TO ADJACENT FINISH
SURFACES.
2. ADJUST HARDWARE AND DOORS AFTER INSTALLATION FOR PROPER OPERATION.
3. REMOVE AND REPLACE DOORS O2 FRAMES WHICH ARE WARPED, BOWED OR
OTHERWISE DAMAGED.
BECTNN 083220 - SLAMS AID STACKING GLASS DOOR MTM
PART I- GENERAL
1.00 SECTION INCLUDES
A. SLIDING FRAMELESS GLASS PANEL PARTITIONS (INTERIOR ONLY)
1.01 RELATED REQUIREMENTS
A. SECTION 05 50 00 - METAL FABRICATIONS: FOR OVERHEAD SUPPORTS THAT ATTACH
GLASS PANEL PARTITION TRACKS TO STRUCTURE, NOT SPECIFIED IN 114I5 SECTION.
1.02 REFERENCE STANDARDS
A. AAMA 611 - VOLUNTARY SPECIFICATION FOR ANODIZED ARCHITECTURAL ALUMINUM
B. ASTM INTERNATIONAL
I. ASTM All STANDARD SPECIFICATION FOR ANNEALED OR COLD -WORKED
AUSTENITIC STAINLESS STEEL SWEET, STRIP, PLATE, AND FLAT BAR.
2. ASTM B221/ASTM 5221M STANDARD SPECIFICATION FOR ALUMINUM AND
ALUMINUM -ALLOY EXTRUDED BARS, RODS, WIRE, PROFILES, AND TUBES.
3. ASTM CI048 STANDARD SPECIFICATION FOR HEAT -STRENGTHENED AND FULLY
TEMPERED FLAT GLASS.
4. ASTM C1172 STANDARD SPECIFICATION FOR LAMINATED ARCHITECTURAL FLAT
GLASS.
C. BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (5L3MA):
I. AN5VBHMA AI56 SERIES
D. CODE OF FEDERAL REGULATIONS
I. 16 CFR 1201 SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS
E. INTERNATIONAL CODE COUNCIL (ICC):
L ICC AII7.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ANSI)
F. U.S. ARCHITECTURAL 4 TRANSPORTATION BARRIERS COMPLIANCE BOARD:
I. AMERICANS WITH DISABILITIES ACT (ADA) AND ARCHITECTURAL BARRIERS ACT
(ABA) ACCESSIBILITY GUIDELINES FOR BUILDING AND FACILITIES
1.03 ADMINISTRATIVE REQUIREMENTS
A. COORDINATION:
1. COORDINATE INSTALLATION OF GLASS PANEL PARTITIONS WITH INSTALLATION OF
FLOOR, WALL, AND CEILING CONSTRUCTION TO COMPLY WITH SUBSTRATE
TOLERANCE REQUIREMENTS OF PARTITION MANUFACTURER.
2. COORDINATE INSTALLATION OF ANCHORS AND SECONDARY STRUCTURAL MEMBERS
INDICATED ON APPROVED GLASS PANEL PARTITION SHOP DRAWINGS AND
SPECIFIED IN OTHER SECTIONS.
1.04 ACTION SUBMITTALS
A. PRODUCT DATA: FOR EACH GLASS PANEL PARTITION AND DOOR COMPONENT
SPECIFIED, INCLUDING:
I. GLASS PANELS
2. RAILS
3. DOOR HARDWARE AND ACCESSORIES
B. SHOP DRAWINGS: FOR FIXED GLASS PANEL PARTITIONS:
I. INCLUDE PLANS, ELEVATIONS, SECTIONS, AND DETAILS. PROVIDE NUMBERED
PANEL INSTALLATION SEQUENCE.
2. SHOW LOCATIONS AND REQUIREMENTS FOR TRACKS, BRACING, BLOCKING, AND
ATTACHMENTS TO OTHER WORK.
3. INDICATED STACKING ARRANGEMENTS AND CLEARANCES.
C. HARDWARE SCHEDULE:
I. SUBMIT HARDWARE SCHEDULE FOR EACH DOOR OPENING.
2. INCLUDE CATALOG CUTS IF NOT SHOWN ON SHOP DRAWINGS.
D. SAMPLES FOR VERIFICATION: FOR EACH EXPOSED COMPONENT INCLUDING HARDWARE,
FOR EACH COLOR AND FINISH SELECTED, OF SIZE INDICATED BELOW:
I. GLASS: UNITS 12' (300mm) SQUARE.
2. EXPOSED RAIL AND TRACK MEMBERS: NOT LESS -THAN 6' (150rvri LONG.
3. HARDWARE: ONE OF EACH TYPE OF EXPOSED DOOR HARDWARE ITEMS.
1.5 INFORMATIONAL SUBMITTALS
A. QUALIFICATION DATA: FOR QUALIFIED INSTALLER
B. WARRANTY: SAMPLE OF UNEXECUTED MANUFACTURER WARRANTY.
1.06 QUALITY ASSURANCE
A. INSTALLER QUALIFICATIONS: EXPERIENCED INSTALLER EQUIPPED AND TRAINED FOR
INSTALLATION OF GLASS PANEL PARTITIONS REQUIRED FOR THIS PROJECT WITH
RECORD OF SUCCESSFUL COMPLETION OF NOT LESS THAN FIVE PROJECTS OF SIMILAR
SCOPE.
B. SINGLE 501JRCE RESPONSIBILITY: PROVIDE GLASS PANEL PARTITIONS AND ASSOCIATED
HARDWARE BY A SINGLE MANUFACTURER THROUGH A SINGLE SOURCE.
C. • FOR LARGE OR COMPLEX PROJECTS PROVIDE MOCK UPS: PROVIDE MOCKUP
CONSISTING OF INITIAL SECTIONS OF TRACKS, FRAMES, AND GLASS PANELS WITH
OPERATING DOORS AND HARDWARE, IN LOCATION AS DIRECTED BY ARCHITECT.
PROCEED WITH WORK UPON APPROVAL OF MOCKUP BY ARCHITECT.
1.07 WARRANTY
A. SPECIAL MANUFACTURER'S WARRANTY: STANDARD FORM IN WHICH MANUFACTURER
AGREES TO REPAIR OR REPLACE COMPONENTS OF GLASS PANEL PARTITIONS THAT
DEMONSTRATE DETERIORATION OR FAULTY OPERATION DUE TO DEFECTS IN
MATERIALS OR WORKMANSHIP UNDER NORMAL USE WITHIN WARRANTY PERIOD
SPECIFIED.
1. WARRANTY PERIOD: [TWO] YEARS DATE OF SUBSTANTIAL COMPLETION.
PART 2 - PRODUCTS
2.01 MANUFACTURERS
A. BASIS -OF -DESIGN PRODUCT: PROVIDE SLIDING GLASS PANEL PARTITIONS
MANUFACTURED BY DORMA USA, INC., SUPPLIED BY INFINITY;
PH: (613) BM-0301
EMAIL: KBLAYSSINFINITY-AP.COM
WETBSITE: HTTP://INFINITY-APAFT/
B. SOURCE LIMITATIONS: OBTAIN GLASS PANEL PARTITION COMPONENTS THROUGH ONE
SOURCE FROM A SINGLE MANUFACTURER.
2.02 PERFORMANCE REQUIREMENTS
A. ACCE55151LITY STANDARD: COMPLY WITH APPLICABLE PROVISIONS IN ADA-ABA
ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES, ICC A117.11 AND
REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.
2.03 GLASS PANEL PARTITIONS
A. HORIZONTAL SLIDING GLASS PANEL PARTITIONS: FULLY -GLAZED, TOP -HUNG
STACKABLE SLIDING GLASS PANEL PARTITION WITHOUT FLOOR TRACK, WITH TOP AND
BOTTOM DOOR RAILS AND BUTT -GLAZED DRY JOINT BETWEEN PANELS, AND EQUIPPED
WITH [SWINGINQ] LAND] [SLIDING] DOOR PANELS WHERE INDICATED.
DORMA 14514-DR5 IS A PREMIER LINE CUSTOM MODEL USING FRAMLESS aW OR 1/2'
THICK TEMPERED GLASS WITH 3.625' (92mm) TOP RAILS AND 3.625' (92MM) HIGH
BOTTOM RAILS
I. BASIS OF DESIGN: DORMA-GLAS HORIZONTAL SLIDING WALL [NSW-DRS]
2. STACKING ARRANGEMENTS: AS INDICATED ON DRAWINGS.
3. STACKING OPERATIONS: MANUAL.
4. PARTITION TOP TRACK: 0.236 INCH THICK, ALUMINUM EXTRUSION, LOW -PROFILE;
DESIGNED FOR OPERATION, SIZE, AND WEIGHT OF GLASS PANEL DOOR, WITH
FACTORY -FINISHED HEAD CLOSURE TRIM AND SEALS.
a. TRACK MOUNTING: CEILING RECESS -MOUNTED]
S. SLIDING PANEL CARRIERS: CENTER -MOUNTED, SELF BALANCING TROLLEY SYSTEM
DESIGNED FOR OPERATION, SIZE, AND WEIGHT OF GLASS PANEL DOOR CONSISTING
OF STAINLESS STEEL COMPONENTS WITH VINYL ROLLER SURFACES.
B. RAIL FITTINGS, GENERAL: ALL -GLASS CLAMPING FITTINGS IN TYPES, SIZES,
QUANTITIES, AND MOUNTING LOCATIONS RECOMMENDED BY MANUFACTURER FOR GLASS
DOOR TYPES, SIZES, AND OPERATION AND GLASS PANEL CONFIGURATIONS.
1. RAIL CONFIGURATION:
a. BASIS OF DESIGN, DORMA DR5 RAILS
b. TOP RAIL: 3 5/8' (92m )
1) PROFILE: [TAPERED]
2) HARDWARE: WITH MANUFACTURER'S STANDARD PIVOT WHERE
INDICATED ON DRAWINGS.
c. BOTTOM RAIL: C3 5/8'(92mm)3
1) PROFILE: [TAPERED]
2) WITH MANUFACTURER'S STANDARD PIVOT AND SLIDE BOLT] CAND
DEADLOCK] WHERE INDICATED ON DRAWINGS.
2. RAIL CAPS: FORMED METAL SNAP -ON FACE AND END CAPS, MATERIAL AND
FINISH AS FOLLOWS:
a. ALUMINUM, [SEE DOOR SCHEDULE]
3. LOCKING SYSTEM: MOUNTED ON BOTTOM RAIL, ENGAGED BY USE OF
INTERLOCKING FLOOR BOLT.
a. MORTISE LOCK: BRASS, IN POSITION INDICATED, WITH ROUND BOLT
ENGAGING DUSTPROOF FLOOR STRIKE, [WITH CYLINDER] [WITH THUMBTURNI.
C. FRAMED PANEL STILES: REFER TO DOOR SCHEDULE
D. PARTITION SUBSTRUCTURE: MODULAR EXTRUDED ALUMINUM I -BEAM WITH ASSOCIATED
THREADED ROD, STRUTS, BRACKETS, PLATES, AND FASTENERS DESIGNED FOR
CONTINUOUS SUPPORT AND RIGID BRACING OF PARTITION TOP ?RACK AND
ADJUSTABLE FOLLOWING INSTALLATION OF PARTITION TO MAINTAIN PARTITION WITHIN
OPERATING TOLERANCES SPECIFIED BY MANUFACTURER.
2.04 PIVOTING PANELS
A. ACCESSIBILITY STANDARD: COMPLY WITH APPLICABLE PROVISIONS IN ADA-ABA
ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES, ICC A117.1, AND
REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.
B. PIVOTING FIXED END PANEL: SINGLE OR PAIRED GLASS PANEL MATCHING PARTITION
PANEL MATERIAL AND THICKNESS; SIZE AND SWING AS INDICATED ON DRAWINGS.
2.05 MATERIALS
A. ALUMINUM: ASTM 5221 (ASTM 9221M), WITH STRENGTH AND DURABILITY
CHARACTERISTICS OF NOT LESS THAN ALLAY 6063-T5.
B. STAINLESS STEEL: ASTM AGEE, TYPE 304.
2.06 FINISHES
A. STAINLESS STEEL FINISHES:
1. No. 4 DIRECTIONAL SATIN FINISH.
2.07 HARDWARE:
A. CONCEALED TRANSOM CLOSERS AND BOTTOM PIVOTS: CENTER HUNG; BHMA AI56.4,
GRADE I. PROVIDE HOUSINGS, ARMS, MOUNTING BRACKETS, FLOOR PIVOT SET, AND
ACCESSORIES.
I. BASIS OF DESIGN: DORMA, RTSW SERIES TRANSOM DOOR CLOSER.
2. SWING: SINGLE- OR DOUBLE-ACTING AS INDICATED ON DRAWINGS, WITH
ADJUSTABLE CUSHIONED STOP [AND POSITIVE DEAD STOP], [AND HOLD OPEN].
3. OPENING FORCE: COMPLY WITH INTERIOR DOOR OPERATING FORCE OF
AUTHORITIES HAVING JURISDICTION FOR ACCESSIBILITY REQUIREMENTS AND
EGRESS DOORS.
B. CONCEALED FLOOR CLOSERS AND TOP PIVOTS: CENTER HUNG BHMA AI56.4, GRADE I.
PROVIDE HOUSINGS, ARMS, BOTTOM INSERT, MOUNTING BRACKETS, COVER PLATES,
AND ACCESSORIES.
I. BASIS OF DESIGN: DORMA, BTS75 SERIES] CBTSBO SERIES] FLOOR CONCEALED
DOOR CLOSERS.
2. SWING: SINGLE OR DOUBLE ACTING AS INDICATED ON DRAWINGS [AND P054TIVE
DEAD STOP], [AND FIXED HOLD -OPEN?.
3. OPENING FORCE: COMPLY WITH INTERIOR DOOR OPERATING FORCE OF
AUTHORITIES HAVING JURISDICTION FOR ACCESSIBILITY REQUIREMENTS AND
EGRESS DOORS.
4. EXPOSED COMPONENT FINISH: [METALLIC PAINTED ALUMINUM] OR [METALLIC
PAINTED, AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL LINE] OR
[PAINTED, MATCH ARCHITECTS CUSTOM COLOR] OR TRAIN ARM PLATED, AS
SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL LINE].
C. PULLS AND HANDLES:
I. CRL BRUSHED NICKEL FRAMELESS SLIDING GLASS DOOR HANDLE, SG48BN.
D. LOCI[ CYLINDERS: TUMBLER TYPE, CONSTRUCTED FROM BRASS OR BRONZE,
STAINLESS STEEL, OR NICKEL SILVER BHMA AI56.5, GRADE I, PERMANENT
REMOVABLE CORES; WITH FACE FINISH MATCHING LOCKSET [KEYED TO MASTER KEY
SYSTEM
E. LOCK CYLINDERS: AS SPECIFIED IN SECTION 08 71 00 'DOOR HARDWARE'
F. LOCK CYLINDERS: FLAT KEY, FIVE -PIN, CORROSION RESISTANT [BRASS] [NICKEL]
FINISH, ANTI -PICK, FUNCTION AS SELECTED BY ARCHITECT [KEYED TO MASTER KEY
SYSTEM].
I. BASIS OF DESIGN: DORMA, EUROPROFILE DEC 150.
G. WEATHER STRIPPING: CPILE] [BRUSH] TYPE; REPLACEABLE E WITHOUT REMOVING DOOR
PANELS FROM PIVOTS.
2.06 GLASS PANELS
A. GLASS PANELS, GENERAL: PROVIDE GLASS PANES THAT COMPLY WITH 16 CFR 1201,
CATEGORY II REQUIREMENTS FOR SAFETY GLAZING. PERMANENTLY MARK GLAZING WITH
CERTIFICATION LABEL OF THE SGCC.
I. GLASS AND DOOR PANEL THICKNESS: THICKNESS REQUIRED FOR SIZE OF PANEL
BASED UPON MANUFACTURER'S WRITTEN RECOMMENDATIONS, BUT NOT LESS THAN
10[MM
B. FULLY TEMPERED CLEAR FLOAT GLASS CGLG,: ASTM CI048, KIND FT, CONDITION A,
TYPE I, CLASS I, QUALITY-GS, THICKNESS CIOMMI [I3MM7.
"NommosoZ 461 FROM ROAD
BRINERNIN19:1.1 PARAMUS NJ 07652
j` O TI973.253.9393
rt WWW.SARGARCH.COM
�w
I
Z
O
DT
U)
O
C7
N
V
M
IIII
Ill
IIIIIIIIIIII�o
U
o
qt
D
C)a
f0
I-_
vi
(n
=
X
C:
Z
E
LTL
.
O
0
U
O
zO
Z
�
3
0
v
(DIt
Ita
Ui
4t
Ln
d
d
a
KO
0
w
E
m
of
J
O
aa'
i
CL
W
H
M
n
<5eAa
3 e= � 199d58
Ci i 5 .z
sCSs =ae.S BEas
mew sew_
a= €vaatN
IS
ulilsp
Wi
aaW_ E5. 83.aw:e ci"sea`s$6eRa5
W9
E=e Z=_1�§ g0
a=e
�n-s6 ae�a8 ssy3g�9.8 1B. $ 16
WC€aita SUM §w
q?Neal
Q§gg ,, lg��- ga
€a s s Vgzi a$1at 0Xc 3g 5RE
:R ow 0a' E ai a %1
S {{
a g nr aW 3y- sh,12
r
N I+1 M
O
0e) I 1
a,_�
i
d
0m't
0)
W
V
r
r^
(1)
al
O
Y
j
at0
U
V
O
O
o
w f .. o
a�a
T
U Z W
a a
W x o N
W - M
r
C] CN VI
O N 00
Q
i U O
O
o
M
•�•LU
03
\
J W
� 3
Ua
M
�1:
VIZ/
Q N
M
x w m
ItTT
if.
i
W>^
o
j_go�
W W
z
L-
1-
U W
�UqkW
ao
�2
U
W
14 W
z U
'o
`JM5a
oQW_ad
c
a
m
U�a KaJ
ZAo!�)
REVISIONS:
acau.x¢a BY
wrz
DATE ISSUED: 05/31 /2019
DESIGNED BY: JH
DRAWN BY: YL
CHECKED BY: YL
SPECIFICATIONS
1WFF1kI C. w I I IV/ IJ