HomeMy WebLinkAboutA15.4 SpecsP. RECESSED WALL STUD INSTALLATION SEQUENCE
I. REMOVE RUBBER FILLER FROM STANDARD BEFORE RECESSED STUD IS PUT IN PLACE.
2, MASK TAPE STANDARD PORTION OF RECESSED STUD FOR ALL WALLS RECEIVING
PAINT OR WALL COVERING.
B. SET RECESSED STUDS IN WALL.
4. USE LASER TO SET CONSISTENT HEIGHT OF STANDARD PORTION OF RECESSED
STUDS - SCREW CLIP IN TOPS AND BOTTOMS. (SET INSERT 7'-0" A.F.F.)
S. INSTALL DRYWALL ON RECESSED STUDS - AVOID DRYWALL FACTORY EDGE AGAINST
STANDARD (REQUIRES EXCESSIVE MUD BUILD UP).
6. FLAT TAPE DRYWALL AGAINST STANDARD,
7. SAND MUD DOWN TO STANDARD TO AVOID EXCESS WILD UP.
8. APPLY ALL FINISH MATERIALS TO WALL PRIOR TO CUTTING OUT STANDARD SLOTS.
9. USE RAZOR BLADES TO CUT OUT STANDARD SLOTS - TOPS AND BOTTOMS OF ALL
SLOTS MUST ALIGN. CUTS TO BE MADE INSIDE OF STANDARD SLOTS.
10. WHEN COMPLETE - INSTALL BRACKETS ON EACH STANDARD AND INSTALL ROD TO
VERIFY ALIGNMENT.
2.
INSTALL CEILING SYSTEMS IN A MANNER CAPABLE OF SUPPORTING SUPERIMPOSED
LOADS, WITH MAXIMUM PERMISSIBLE DEFLECTION OF/8'IN 10'-0".
B.
CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR
ENSURING ACCESS FOR PERSONS WITH DISABILITIES.
3.
ENSURE SUSPENSION SYSTEM 15 LOCATED TO ACCOMMODATE FITTINGS AND UNITS OF
EQUIPMENT WHICH 15 TO BE PLACED AFTER INSTALLATION OF CEILING GRID.
C.
MANUFACTURER: THE MATWORKS COMPANY 1119DO OLD BALTIMORE PIKE, BELTSVILLE,
MD 20705, (301-857-1272)
4.
WHERE DUCTS OR OTHER EQUIPMENT PREVENT REGULAR SPACING OF HANGERS,
I. 55W ENTRY: REFER TO FINISH SCHEDULE.
REINFORCE NEAREST ADJACENT HANGERS AND RELATED CARRYING CHANNELS AS
REQUIRED TO SPAN REQUIRED DISTANCE.
D.
INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES
AND STANDARDS. G.C. TO PAINT SUBSTRATE. ONCE DRY, CLEAN RECESSED WELL PRIOR TO
5.
INSTALL EDGE MOLDINGS AT INTERSECTION OF CEILING AND VERTICAL SURFACES,
INSTALLING GRID.
USING MAXIMUM LENGTHS, STRAIGHT, TRUE TO LINE AND LEVEL; MITER CORNERS.
6.
FIT ACOUSTIC UNITS IN PLACE, FREE FROM DAMAGED EWES OR DEFECT
SECTION 01172111111 - WIML-COATED FABRIC WALL COVERED
DETRIMENTAL TO APPEARANCE AND FUNCTION. LAY DIRECTIONALLY PATTERNED
UNITS ONE WAY WITH PATTERN AS DIRECTED. FIT BORDER UNITS NEATLY AGAINST
A
GENERAL: PROVIDE PREFINISHED GLASS FIBER REINFORCED POLYESTER RESIN FABRICATED
ABUTTING SURFACES.
WALL PANELS, WITH TRIM PIECES AND ACCESSORIES AS REQUIRED FOR COMPLETE
7.
INSTALL UNITS LEVEL, IN UNIFORM PLANE AND FREE FROM TWIST, WARP AND DENTS.
INSTALLATION
8.
INSTALL HOLD-DOWN CLIPS WHERE REQUIRED BY APPLICABLE CODES AND WHERE
B.
SUBMITTALS: SEE SECTION 013000.
CEILING IS WITHIN 20LO' OF AN EXTERIOR DOOR.
I ADJUSTMENT:
ADJUST SAGS OR TWISTS WHICH DEVELOP IN CEILING SYSTEM AND REPLACE
C.
MAINTENANCE INSTRUCTIONS: SEE SECTION 017000.
ANY
PART WHICH IS DAMAGED OR FAULTY.
D.
MANUFACTURERS: AS INDICATED ON FINISH SCHEDULE.
SECTION OSS000 - TEUNG
SECTION M420 - WOOD STEP AND PLANS FLOORING
E.
TYPES: AS INDICATED ON FINISH SCHEDULE.
A. GENERAL: PROVIDE TILE SYSTEMS INCLUDING SETTING MATERIALS, GROUT AND
A.
GENERAL: INSTALL SHOP FINISHED ACRYLIC IMPREGNATED WOOD STRIP FLOORING SYSTEM
ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
F.
ADHESIVE: NONTOXIC TYPE RECOMMENDED BY WALL COVERING MANUFACTURER TO SUIT
B. STANDARDS: COMPLY WITH TILE COUNCIL OF AMERICA 'HANDBOOK OF CERAMIC TILE
B.
PROJECT CONDITIONS: DO NOT INSTALL WOOD FLOORING SYSTEM UNTIL WET CONSTRUCTION
APPLICATION.
INSTALLATION' INCLUDING REFERENCED ASTI AND ANSI STANDARDS.
WORK 15 COMPLETED AND SURROUNDING AIR WAS MAXIMUM MOISTURE CONTENT OF 40
PERCENT. PROVIDE PERMANENT HEAT, LIGHT AND VENTILATION PRIOR TO INSTALLATION.
G.
PROVIDE PRIMER WHICH ALLOWS REMOVAL OF WALL COVERING FROM GYPSUM BOARD
C. TILE MANUFACTURERS: AS INDICATED ON DRAWINGS.
WITHOUT DAMAGING PAPER FACING OF BOARD, AND WITHOUT PREMATURE SEPARATION OF
I. MAINTAIN ROOM TEMPERATURE BETWEEN 60-90 DEGREES F, HUMIDITY 25-50 FOR
WALL COVERING FROM WALL. PRIMER TO BE NON -STAINING AND NON -TOXIC, AS
I. FLOOR TILE: PROVIDE NON -SLIP UNITS WITH MINIMUM WET AND DRY VALUE OF 0.60
PERIOD OF SEVEN DAYS PRIOR TO DELIVERY OF MATERIALS
RECOMMENDED BY WALL COVERING MANUFACTURER.
COEFFICIENT OF FRICTION WHEN TESTED IN ACCORDANCE WITH ASTI C1028.
D. LATEX TWIN CO - OUS MORTAR
N SLT� THINSLT BOND AT LATEX CEMENTITI ORT R CONFORMING TO AN51
�
C.
MANUFACTURER: PERMAGRAIN
W.
EXAMINATION: ENSURE SURFACES TO RECEIVE WALL COVERING ARE CLEAN, TRUE AND FREE
AII8.4.
D.
WOOD: AS INDICATED ON DRAWINGS TONGUE AND GROOVED EWES WITH SHOP APPLIED
OF IRREGULARITIES, DONOT COMMENCE WITH WORK UNTIL SURFACES ARE SATISFACTORY.
ACRYLIC IMPREGNATED FINISH INTENDED FOR DIRECT ADHESIVE APPLICATION TO CONCRETE.
ENSURE WALL SURFACE FLATNESS TOLERANCE DOES NOT VARY MORE THAN 1/8' IN 10-0",
E. GROUT: ANSI A118.6, LATEX CEMENTITIOUS TYPE BY LATICRETE, BOSTIK OR CUSTOM
NOR VARY AT A RATE BEATER THAN I/16 PER RUNNING FOOT.
G G
BUILDING0
PRODUCTS. REFER T DRAWINGS.
E.
O
ADHESIVE: TYPE AS RECOMMENDED BY MANUFACTURER T ENSURE MAXIMUM DURABILITY
OVER TIME; NONTOXIC, WATERPROOF TYPE SUITABLE FOR FLOORING, SUBSTRATE, AND
1.
PREPARATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS; FILL NICKS, GOUGES AND
I INTEGRAL WATERPROOFING: LATICRETE, BOSTIK, OR NOBEL LIQUID RUBBER INTEGRAL TILE
ACCEPTABLE TO APPLICABLE AUTHORITIES.
OTHER MINOR IMPERFECTIONS OF SUBSTRATES WITH LATEX FILLER; SAND SMOOTH, FLUSH
SETTING WATERPROOFING SYSTEM WITH NO BITUMINOUS EXTENDS; PROVIDE AT TILE
WITH SURFACE; APPLY PRIME COAT IN ACCORDANCE WITH MANUFACTURERS
APPLICATIONS ABOVE GRADE.
I
SUBFLOOR FILLER: UTILIZE PORTLAND CEMENT BASED PRODUCTS FOR FLOOR PREP
RECOMMENDATIONS.
G. CLEANING AND SEALING MATERIALS: AS RECOMMENDED BY TILE AND GROUT
G.
DIVIDER STRIPS: TYPE AS INDICATED IN DETAILS.
MANUFACTURERS, SUCH AS BOSTIK CONSTRUCTION PRODUCTS/HYDROMENT CERAMASEAL.
J.
APPLICATION: HANDLE AND APPLY WALL COVERING IN ACCORDANCE WITH MANUFACTURER'S
H.
PREPARATION: BROOM CLEAN SUBSTRATE SURFACE AND ENSURE FLOOR SURFACE IS
RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; MIX AND APPLY ADHESIVE IN
H. SURFACE A COMMENCE W UNTIL SURFACE CONDITIONS
PREPARATION: DO NOT ENE WORK TL RF E CONDT ARE WITHIN
x x
SMOOTH AND FLOAT TO PLUS OR MINUS I/8 PER 10'-0, FREE OF OIL, GREASE, DUST AND
ACCORDANCE WITH ADHESIVE MANUFACTURERS RECOMMENDATIONS.
TOLERANCES REQUIRED FOR PROPER INSTALLATION.
FOREIGN SUBSTANCE. USE LATEX FILLER TO PATCH CRACKS AND SMALL HOLES, AND FOR
I. WHERE RA TESTING 15 GREATER THAN 80X AS PER ASTM F-2170. QUICK -SETTING,
MINOR LEVELING.
WATER-RESISTANT, HIGH -COMPRESSIVE -STRENGTH, SELF -LEVELING UNDERLAYMENT:
I. USE PANELS IN EXACT ORDER AS CUT FROM ROLLS; USE ROLLS IN CONSECUTIVE
E
ADVANCED HYDRAULIC, SPECIALLY FORMULATED FOR THE RESURFACING OF INTERIOR
1. GRIND CONCRETE WHERE RIDGES AND IRREGULARITIES PROVIDE UNSATISFACTORY
ORDER NUMBERED BY MANUFACTURER.
HORIZONTAL SURFACES WHERE ENVIRONMENTAL CONTROLS ARE NOT IN PLACE, TWAT
SUBSTRATE FOR WOOD STRIP FLOORING.
CAN BE APPLIED IN MINIMUM UNIFORM THICKNESS OF 1/4 INCH TO I INCH (6 MM TO
2. HORIZONTAL SEAMS AND CUTTING AT CORNERS ARE NOT ACCEPTABLE; CUT NO
25 MM).
I.
INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION
CLOSER THAN 2" OF AN INSIDE CORNER, AND NOT CLOSER THAN 6' OF AN OUTSIDE
I.a. PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE MAPEI
INSTRUCTION FOR DIRECT APPLICATION OF WOOD STRIP FLOORING OVER CONCRETE.
CORNER.
CORPORATION; ULTRAPLAN EXTREME 2.
Lit. PRODUCT: LATICRETE NXT LEVEL OR I LEVEL PLUS
1. ENSURE JOINTS OF WOOD FLOORING ARE IN LINE; ENSURE FULL ADHESIVE CONTACT
2. WHERE RH TESTING 15 LESS THAN 80% AS PER A57M F-2170 WIGW-PERFORMANCE,
FOR PERMANENT BOND TO SUBSTRATE.
B. FILL SPACES ABOVE 4 BELOW WINDOWS, DOORS, AND SIM. AREAS IN SEQUENCE FROM
QUICK -SETTING, HYDRAULIC CEMENT UNDERLAYMENT: POLYMER -MODIFIED,
ROLL.
SELF -LEVELING, HYDRAULIC CEMENT PRODUCT THAT CAN BE APPLIED FROM FEATHER
2. LAY FLOORING SYMMETRICAL ABOUT ROOM CENTER LINE; FIT NEATLY TO VERTICAL
EWE TO 1-1/2 INCHES (38 I
INTERRUPTIONS.
INSTALL IN PATTERN AS PROVIDED BY MANUFACTURER OR AS INDICATED IN DRAWINGS
2.a. PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE MAPEI
CORPORATION; ULTRAP I PLUS.
3. PROVIDE DIVIDER STRIPS AT CENTERLINE OF DOOR OPENINGS AND WHERE FLOORING
2.6. PRODUCT: LATICRETE NXXTT LEVEL OR NM LEVEL PLUS
TERMINATES WITH TILE OR OTHER FLOOR FINISHES. (SEE FINISH PLAN LAYOUT)
SECTION OSTMIG - NK04I M ITEMWALL COVERINGS III PANELS)
3. WATER: POTABLE AND AT A TEMPERATURE OF NOT MORE THAN 70 DEGREE F (21
DEGREE C)
4 PROVIDE MAXIMUM 1:12 SLOPE WHERE FINISHED FLOOR SURFACE CHANGES LEVEL
A.
GENERAL: PROVIDE PREFINISHED CLA55 FIBER REINFORCED POLYESTER RE51N FABRICATED
4. PRIMER: PRODUCT OF UNDERLAYMENT MANUFACTURER RECOMMENDED IN WRITING FOR
BETWEEN WOOD FLOORING AND ADJACENT FLOORING.
WALL PANELS, WITH TRIM PIECES AND ACCESSORIES AS REQUIRED FOR COMPLETE
SUBSTRATE, CONDITIONS, AND APPLICATION INDICATED.
5. PROVIDE MOISTURE BARRIER AS RECOMMENDED BY VENDOR.
INSTALLATION.
4.a. ALL-PURPOSE PRIMER FOR SELF -LEVELING UNDERLAYMENTS:
4.a.a. PRODUCT: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE MAPEI
CORPORATION: PRIMER T.
J.
MOISTURE TESTING: FOR REQUIREMENTS, REFER TO SECTION 093000, ITEM J.
B.
MANUFACTURERS: KEMLITE COMPANY/KEMLITE FIRE-X GLASBORD PLUS, SEQUENTIA, SET.
4.o.b. PRODUCT: LATICRETE NXT PRIMER
INC./STRUCTOGLAS PYRO PANEL SYSTEM, OR I PRODUCTS, INC./FIBER-LITE PANELS,
CLASS
I. INSTALLATION: COMPLY WITH TILE COUNCIL OF AMERICA (TCA) HANDBOOK FOR CERAMIC
SECTION OESS - RESIENT TILE FLOORING
TILE INSTALLATION FOR LATEX BOND COAT THIN SET APPLICATION.
A.
GENERAL: PROVIDE RESILIENT TILE FLOORING SYSTEM AND RESILIENT BASE, WITH
C.
PANELS: FIBERGLASS REINFORCED PLASTIC (FRP) PANEL SYSTEM; NOMINAL 0.090'
ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
THICKNESS; WHITE.
I. TILE: INSTALL TILE IN ACCORDANCE WITH REFERENCED ANSI STANDARDS AND TCA
RECOMMENDATIONS FOR TYPE OF SUBSTRATE AND INDICATED SETTING METHOD;
B.
SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF FLOORING AND
LATEX -CEMENT THIN SET AND BOND COATS REQUIRED.
BASE COLOR AND PATTERN SELECTED.
I. FIRE -RATING: CLA55 I (UL CLASS A), MAXIMUM 25 FLAME SPREAD, 25 SMOKE
GENERATION BASED ON ASTI E84 INSTALLATION.
2. PLACE TILE IN ACCORDANCE WITH PATTERNS INDICATED ON DRAWINGS OR AS
C.
PROJECT CONDITIONS: ENSURE FLOOR SURFACES ARE SMOOTH AND FLAT WITH MAXIMUM
DIRECTED BY OWNER'S PROJECT MANAGER; CAREFULLY PLAN TILE LAYOUTS, ENSURE
VARIATION OF 1/8' IN 101 ENSURE CONCRETE FLOORS ARE DRY AND EXHIBIT NEGATIVE
D.
TRIM PIECES: MANUFACTURER'S STANDARD MATCHING MOLDINGS AND TRIM PIECES AS
PATTERN IS UNINTERRUPTED FROM ONE SURFACE TO THE NEXT AND THROUGH
ALKALINITY, CARBONIZING AND DUSTING.
REQUIRED FOR COMPLETE, FINISHED INSTALLATION, AND AS REQUIRED FOR JOINTS,
DOORWAYS.
CORNERS AND PANEL EWES.
3. SEAL TILE AND GROUT SURFACES WHERE RECOMMENDED BY MANUFACTURER FOR
D.
RESILIENT TILE: 12' X 12' BY 1/6" THICK; VINYL COMPOSITION TILE CONFORMING TO ASTI
MATERIALS AND APPLICATIONS INVOLVED; COMPLY WITH MANUFACTURER'S
F1066, COMPOSITION I; COLOR AND PATTERN AS INDICATED IN FINISH SCHEDULE.
E.
ADHESIVE: MANUFACTURER'S RECOMMENDED NONTOXIC, WATERPROOF ADHESIVE SUITABLE
RECOMMENDATIONS.
I. MANUFACTURERS: ARMSTRONG WORLD INDUSTRIES, INC.; AZROOK INDUSTRIES, INC.;
FOR SUBSTRATES INDICATED.
J. MOISTURE TESTING: PROCEED WITH INSTALLATION ONLY AFTER SUBSTRATES PASS TESTING
TARKETT INC., OR APPROVED EQUAL.
FLAMMABILITY: PROVIDE MATERIALS TESTED UNDER ASTM E648, FLOORING
F.
PRIMER: PROVIDE NON -STAINING RELEASE COAT PRIMER AS RECOMMENDED BY WALL PANEL
ACCORDING TO FLOORING MANUFACTURER'S WRITTEN RECOMMENDATIONS. PERFORM ONE OR
RADIANT PANEL TEST, WITH RESULTS OF 0.45 WATT5/CM2 OR HIGHER.
MANUFACTURER WWERE PANELS ARE APPLIED TO GYPSUM BOARD,
BOTH TESTS, AS REQUIRED BY THE MANUFACTURER, IN ACCORDANCE WITH THE FOLLOWING:
2. SLIP RESISTANCE: PROVIDE MATERIALS TESTED UNDER ASTM D2047, JAMES SLIP
I. PERFORM ANHYDROUS CALCIUM CHLORIDE TEST ACCORDING TO ASTMF1869. PROCEED
TEST WITH MINIMUM 0.6 RATING FOR FLOORS.
G.
MECHANICAL FASTENERS: CONCEALED TYPE ONLY; TYPES AS RECOMMENDED BY SYSTEM
WITH INSTALLATION ONLY AFTER SUBSTRATES NAVE MAXIMUM
MANUFACTURER.
MOISTURE -VAPOR -EMISSION RATE ACCEPTABLE TO THE FLOORING MANUFACTURER.
E.
RESILIENT BASE: FS S5-W-401 1/8' GAGE COVED BASE AT HARD FLOOR SURFACES,
2. PERFORM RELATIVE HUMIDITY TEST USING IN SITU PROBES ACCORDING TO
STRAIGHT (TOP SET) BASE AT CARPET; PROVIDE PREMOLDED END STOPS AND EXTERNAL
W.
INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE
ASTMF2170. PROCEED WITH INSTALLATION ONLY AFTER SUBSTRATES NAVE A
CORNERS.
REQUIREMENTS FOR FIRE RATINGS. CORE AND MITER TRIM PIECES. INSTALL PANELS IN
MAXIMUM RELATIVE HUMIDITY LEVEL ACCEPTABLE TO THE FLOORING MANUFACTURER.
I. MANUFACTURERS: BURKE OR ROPPE, MOLDED RUBBER BASE.
MAXIMUM SIZE INCREMENTS AVAILABLE,
WEIGHT: 6" UNLESS OTHERWISE INDICATED.
SECTION OSSDO - ACOUSTICAL CEREIGN
1. INSTALL WALL PANELING BEFORE INSTALLATION OF PLUMBING, BASES, HARDWARE,
2. COLOR: AS INDICATED IN FINISH SCHEDULE.
AND SIMILAR ACCESSORIES.
A. GENERAL: PROVIDE ACOUSTICAL CEILINGS INCLUDING SUSPENSION SYSTEM, TRIM, AND
ACCESSORIES A5 REQUIRED FOR COMPLETE FINISHED INSTALLATION.
F.
EWE STRIPS AND ACCESSORIES: RUBBER OR VINYL EWE STRIPS MATCHING RESILIENT
2. SECURELY ADHERE PANELS TO WALL SURFACES; USE BLIND NAILING METHODS AND
FLOORING; LATEX -MODIFIED PORTLAND CEMENT BASED UNDERLAYMENT AND PATCHING
REQUIRED TO SUPPORT PANELS UNTIL ADHESIVE DRIES; EXPOSED MECHANICAL
B. STANDARDS: CONFORM TO A5TM C635 FOR METAL SUSPENSION SYSTEM AND 5TM C636 FOR
COMPOUND; NONTOXIC WATER RESISTANT TYPE ADHESIVES.
FASTENERS SHALL NOT BE ACCEPTABLE. REMOVE EXCESS ADHESIVE FROM EWES;
INSTALLATION OF ACOUSTICAL CEILINGS.
WIPE SEAM CLEAN WITH DRY CLOTH TOWEL.
G.
SUBFLGOR FILLER: WHITE PREMIXED LATEX -CEMENT PASTE DESIGNED FOR PROVIDING THIN
C. PERFORMANCE REQUIREMENTS: PROVIDE PRODUCTS LISTED BY UNDERWRITERS
SOLID SURFACE FOR LEVELING AND MINOR RAMPING OR SUBSURFACE TO ADJACENT FLOOR
LABORATORIES (UL).
FINISHES; MATERIAL CAPABLE OF BEING APPLIED AND FEATHERED OUT TO ADJACENT FLOOR
WITHOUT 5PALLING.
SECTION OSS000 - PADISG AND COATING
I. FLAME SPREAD/SMOKE DENSITY: PROVIDE PRODUCTS MEETING CODE REQUIREMENTS
W.
PRIMERS AND ADHESIVES: WATERPROOF NONTOXIC TYPES AS RECOMMENDED BY FLOORING
FOR MAXIMUM 25 FLAME SPREAD AND MAXIMUM 25 SMOKE DENSITY.
MANUFACTURER FOR SPECIFIED MATERIAL AND APPLICATION.
A.
GENERAL: PROVIDE PAINTING OF EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS
REQUIRED FOR COMPLETE FINISHED INSTALLATION
D. SEISMIC REQUIREMENTS: COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS FOR SEISMIC
BRACING OF CEILING SUSPENSION SYSTEM, AND WITH ASTM E580.
I.
SEALER AND WAX: TYPE RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIAL TYPE
AND LOCATION.
B.
SURFACES NOT 70 BE PAINTED: PREFINISHED ITEMS; CONCEALED AND INACCESSIBLE AREAS,
E. SUBMITTALS: SUBMIT PRODUCT DATA, SHOP DRAWINGS INDICATING LAYOUT, AND SAMPLES
CODE -REWIRED LABELS.
OF GRID, TRIM, AND CEILING UNITS.
J.
PREPARATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION AND
WITH A5TM I REMOVE SUBFLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS,
I INSTALLER: FIRM WITH MINIMUM THREE YEAR'S SUCCESSFUL EXPERIENCE IN PROJECTS OF
JOINTS, HOLES AND DEFECTS WITH SUBFLOOR FILLER.
C.
STANDARDS: PROVIDE MATERIALS APPROVED FOR USE BY APPLICABLE AIR QUALITY
51MILAR TYPE AND SCOPE; ACCEPTABLE TO MANUFACTURER OF ACOUSTICAL UNITS.
MANAGEMENT DISTRICT FOR LIMITATIONS OF VOLATILE ORGANIC COMPOUNDS FOR
K.
FLOORING INSTALLATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS AND
ARCHITECTURAL COATINGS.
G. PROJECT CONDITIONS: DO NOT INSTALL CEILINGS UNTIL WILDING IS ENCLOSED, SUFFICIENT
INSTALLATION INSTRUCTIONS; SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER TO
HEAT IS PROVIDED, DUST GENERATING ACTIVITIES HAVE TERMINATED AND OVERHEAD
ENSURE FULL ADHESION; SCRIBE FLOORING TO WALLS, COLUMNS, AND OTHER
D.
SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES.
MECHANICAL WORK 15 COMPLETED, TESTED, AND APPROVED; ALLOW WET WORK TO DRY
APPURTENANCES, TO PRODUCE TIGHT JOINTS.
PRIOR TO INSTALLATION.
I. INSTALL MINIMUM 1/2 TILE AT ROOM AND AREA PERIMETER; TERMINATE RESILIENT
I. DUPLICATED PAINTED FINISHES OF APPROVED SAMPLES ON ACTUAL WALL SURFACES
H. ACOUSTICAL UNITS: TYPES AS INDICATED ON DRAWINGS.
FLOORING AT CENTERLINE OF DOOR OPENINGS WHERE ADJACENT FLOOR FINISH IS
AND COMPONENTS FOR APPROVAL PRIOR TO COMMENCING WORK.
DISSIMILAR; INSTALL EWE STRIPS AT UNPROTECTED AND EXPOSED EWES WHERE
I. MANUFACTURERS: ARMSTRONG
FLOORING TERMINATES.
E.
DELIVERY: DELIVER MATERIALS TO JOB SITE IN ORIGINAL, NEW AND UNOPENED PACKAGES
SALES: REFER TO FINISH SCHEDULE FOR ARMSTRONG TYPE.
AND CONTAINERS BEARING MANUFACTURER'S NAME AND LABEL.
BACK -OF -HOUSE AREAS: REFER TO FINISH SCHEDULE FOR ARMSTRONG TYPE.
2. SEE FINISH PLAN FOR FLOOR PATTERN DESIRED IN FALW AREA.
1. SUSPENSION SYSTEM:
L.
MOISTURE TESTING: FOR REQUIREMENTS, REFER TO SECTION 093000, ITEM J.
F.
MANUFACTURER: BENJAMIN MOORE
MANUFACTURERS, ACOUSTICAL UNIT MANUFACTURER, OR C141CAGO METALLIC.
M.
BASE INSTALLATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION
G.
MATERIAL QUALITY: PROVIDE TOP LINE QUALITY COMMERCIAL GRADE PROFESSIONAL
I. TYPICAL: SPECIAL 15/16' NARROW PROFILE WHITE BAKED ENAMEL FINISHED STEEL OR
INSTRUCTIONS; APPLY TO WALLS, COLUMN, PILASTERS, CASEWORK, AND OTHER PERMANENT
PAINTER_ PAINTS; MATERIALS NOT BEARING MANUFACTURER'S IDENTIFICATION AS A
ALUMINUM TYPE; EWE TRIM WITH VERTICAL LEG CONCEALED.
FIXTURES IN ROOMS AND AREAS WHERE BASE IS REWIRED.
BEST -GRADE PRODUCT SHALL NOT BE ACCEPTABLE.
2. BACK -OF -HOUSE AREAS: STANDARD I' PROFILE WHITE BAKED ENAMEL FINISHED
3. MITER INTERNAL CORNERS; USE PREMOLDED SECTIONS FOR EXTERNAL CORNERS AND
I. PRIMERS; PROVIDE PREMIUM GRADE PRIMERS RECOMMENDED BY PAINT
STEEL OR ALUMINUM TYPE, EWE TRIM WITH VERTICAL LEG CONCEALED. J.
EXPOSED ENDS; SCRIBE AND FIT TO DOOR FRAMES AND OTHER OBSTRUCTIONS.
MANUFACTURER FOR SUBSTRATES INDICATED AND FOR FINISH SYSTEMS SPECIFIED.
PREPARATIM MEASURE CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL
N.
EDGE EDGE
E STRIPS: INSTALL WHERE E OF TILE WOULD OTHERWISE BE EXPOSED; BUTT TO
E
UNITS TO BALANCE BORDER WIDTHS AT OPPOSITE EWES OF EACH CEILING; DO NOT
FLOORING WITHOUT GAPS; SET ADHESIVE.
2. UNDERCOATS AND BARRIER COATS: PROVIDE UNDERCOAT PAINTS PRODUCED BY
USE LESS THAN HALF WIDTH UNITS AT BORDERS.
SAME MANUFACTURER AS FIN154 COATS; USE ONLY THINNERS APPROVED BY PAINT
J. COORDINATE WITH OTHER WORK SUPPORTED BY OR PENETRATING THROUGH CEILINGS,
0.
CLEANING: CLEAN, SEAL AND WAX FLOOR IN ACCORDANCE WITH MANUFACTURER'S
MANUFACTURER, AND USE ONLY WITHIN RECOMMENDED LIMITS.
INCLUDING I IrUT FI)C11J 5. "vw- EQUIPMENT AND PARTITION SYSTEMS.
RECOMMENDATIONS.
RELEASED FOR CONSTRUCTION
3. FINISH COATS: PROVIDE FINISH CHATS CAPABLE OF BEING WASHED WITH MILD
TURER RECOMMENDATIONS, ASTM C636, AND
DETERGENT WITHOUT LOSS OF COLOR, SHEEN, OR PIGMENTS.
RATINGS.
SECTION
OSSEO -CARPET WALK -OFF IA7)
Subject to compliance with all regulations
of State and local Codes
DUES AND LEVELS AND FREE FROM WARPED, SOILED
A.
GENERAL: PROVIDE ENTRY CARPET TYPE FLOOR WALK OFF MATS WITH PVC GRID AND
4. FINISH COAT COORDINATION: PROVIDE FINISH COATS WHICH ARE COMPATIBLE WITH
City of Carmel CAL UNITS.
ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. G.L. TO PROVIDE
PRIME PAINTS, UNDERCOATS, AND BARRIER COATS USED. VOLATILE ORGANIC
(1
CARPET TRANSITION STRIPS FOR FLUSH MOUNTING OF MAT WITH ADJACENT FLOOR FINISH.
COMPOUNDS: PROVIDE MATERIALS WITH MINIMAL VOLATILE ORGANIC COMPOUNDS
� 1
(VCC); COMPLY WITH APPLICABLE REGULATIONS.
nATF- (17/19/1Q1A
H. COLORS AND FINISHES: PURE, NON -FADING, APPLICABLE TYPES TO SUIT SERVICE
INDICATED; NO LEAD CONTENT PERMITTED.
I. PREPARATION: PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH
PAINT MANUFACTURER'S INSTRUCTIONS AND AS SPECIFIED FOR SUBSTRATE CONDITION.
1. EXAMINE AREAS AND CONDITIONS UNDER WHICH PAINTING WORK IS TO BE APPLIED.
START OF PAINTING WORK INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS OF
SURFACES AND CONDITIONS WITHIN ANY PARTICULAR AREA.
2. REMOVE HARDWARE, ACCESSORIES, AND ITEMS IN PLACE AND NOT TO BE PAINTED,
OR PROVIDE PROTECTION PRIOR TO SURFACE PREPARATION AND PAINTING; AFTER
PAINTING REINSTALL REMOVED ITEMS.
J. APPLICATION: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS; USE
APPLICATORS AND TECHNIQUES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL
BEING APPLIED.
1. APPLY ADDITIONAL COATS WHEN STAINS OR BLEMISHES SHOW THROUGH FINAL COAT,
UNTIL PAINT 15 A UNIFORM FINISH, COLOR AND APPEARANCE.
2. FINISH DOORS ON TOPS, BOTTOMS AND SIDE EWES SAME AS FACES. PROVIDE
EXTRA ATTENTION TO ASSURE DRY FILM THICKNESS AT CORNERS AND CREVICES 15
EQUIVALENT TO THAT OF FLAT SURFACES.
3. PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS SIMILAR
EXPOSED SURFACES; PAINT SURFACES BEHIND PERMANENTLY -FIXED EQUIPMENT AND
FURNITURE WITH PRIME COAT ONLY.
4. PAINT BACK SIDES OF ACCESS PANELS AND REMOVABLE OR HINGED COVERS TO
MATCH EXPOSED SURFACE.
SECTION 090=10 - PLASTER
A. PREPARATION:
1. PRIME WALLS WITH TWO COATS OF GRAY (PT-93 BENJAMIN MOORE AF-715
x
DOLPHIN
2. ENSURE CORNER BEAD 15 INSTALLED AT OUTSIDE CORNERS OF ALL GYP. BD,
PASS-THRU'S THAT RECEIVE PLASTER FINISH.
3. SAND LIGHTLY BETWEEN EACH SUCCEEDING ENAMEL AND EACH VARNISH COAT.
K. SCHEDULING PAINTING: APPLY FIRST COAT TO SURFACES THAT HAVE BEEN CLEANED,
PRETREATED OR PREPARED FOR PAINTING AS SOON AS PRACTICABLE AFTER
PREPARATION.
I. ALLOW TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPER DRYING. DO NOT
RECOAT UNTIL PAINT FEELS FIRM AND DOES NOT DEFORM OR FEEL STICKY UNDER
MODERATE THUMB PRESSURE.
L. MINIMUM COATING THICKNESS: APPLY MATERIALS AT NOT LE55 THAN MANUFACTURER'S
RECOMMENDED SPREADING RATE, TO ESTABLISH A TOTAL DRY FILM THICKNESS AS
RECOMMENDED BY COATING MANUFACTURER.
M. PRIME COATS: APPLY TO ITEMS NOT PREVIOUSLY PRIMED; RECOAT PRIMED AND SEALED
SURFACES WHERE THERE IS EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST
COAT.
N. FINNISH COATS: PROVIDE EVEN TEXTURE; LEAVE NO LAPS, IRREGULARITY IN TEXTURE,
SKID MARKS, OR OTHER SURFACE IMPERFECTIONS.
0. PAINT SYSTEM: PROVIDE MINIMUM TWO COAT PLUS PRIMER SYSTEMS.
1. EXT. PAINTED METAL: SEMI -GLOSS 100% ACRYLIC.
2. GYPSUM BOARD WALLS: EGGSHELL (SATIN) LATEX EMULSION.
3. GYPSUM BOARD CEILINGS: FLAT LATEX EMULSION.
4. TOILET ROOM WALLS AND CEILINGS: SEMI -GLOSS ACRYLIC ENAMEL,
5. INT. PAINTED METAL: SEMI -GLOSS 100% ACRYLIC.
6. CONCRETE FLOORS: CLEAR PENETRATING SEAL; ONE COAT SYSTEM ACCEPTABLE.
7. FLOOR STRIPES: TRAFFIC BEARING, NON -SLIP STRIPE PAINT; ONE COAT SYSTEM
ACCEPTABLE.
8. SHEENS: COMPLY WITH ASTI D523, REFLECTANCE OF PAINT.
P. CLEAN-UP: DURING PROGRESS OF WORK, REMOVED DISCARDED PAINT MATERIALS,
RUBBISH, CANS AND RAGS FROM SITE AT END OF EACH WORK DAY.
1. CLEAN GLASS AND PAINT -SPATTERED SURFACES IMMEDIATELY BY PROPER METHODS
OF WASHING AND SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FINISHED
SURFACES.
Q. PROTECTION: PROTECT WORK OF OTHER TRADES, WHETHER TO BE PAINTED OR NOT;
CORRECT DAMAGE BY CLEANING, REPAIRING OR REPLACING, AND REPAINTING, AS
ACCEPTABLE TO OWNER'S PROJECT MANAGER.
1. PROVIDE 'WET PAINT" SIGNS TO PROTECT NEWLY-PPAINTED FINISHES.
2. REMOVED TEMPORARY PROTECTIVE WRAPPINGS PROVIDED BY OTHERS FOR
PROTECTION OF THEIR WORK, AFTER COMPLETION OF PAINTING OPERATIONS.
R. REPAIR: AT COMPLETION OF WORK OF OTHER TRADES, TOUCHUP AND RESTORE DAMAGED
SURFACES OR DEFACED PAINTED SURFACES.
DIVISION 10 - SPECIALTIES
SECTION D2MU - METAL TOILET COMPAR71O(T5
A. GENERAL: PROVIDE FLOOR MOUNTED METAL TOILET COMPARTMENTS AND WALL MOUNTED
URINAL SCREENS WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION,
COORDINATE WITH TOILET ACCESSORIES.
I. COORDINATE WITH TOILET ACCESSORIES.
B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR
ENSURING ACCESS FOR PERSONS WITH DISABILITIES.
C. 51,13MITTALS: SUBMIT PRODUCT DATA, SHOP DRAWINGS, AND SAMPLES.
D. MANUFACTURERS: SANYMETAL, GLOBAL, OR FLUSH METAL.
E. TYPE: FLOOR MOUNTED TOILET PARTITIONS AND WALL MOUNTED URINAL SCREENS.
1. FINISH: STANDARD BAKED ENAMEL FINISH COLOR AS SELECTED BY ARCHITECT FROM
MANUFACTURER'S FULL LINE OF COLORS.
I PILASTER SHOES: 3' HIGH; ASTI Ali", TYPE 302/304, NO. 4 POLISHED FINISH; STAINLESS
STEEL
G. ATTACHMENTS, SCREWS AND BOLTS: STAINLESS STEEL; TAMPER PROOF TYPE; HEAVY
DUTY EXTRUDED ALUMINUM BRACKETS.
W. HARDWARE: MANUFACTURER'S STANDARD CHROME PLATED OR SIMILAR FINISH.
I. HINGES: NONFERROUS CAST PIVOT HINGES, GRAVITY TYPE, ADJUSTABLE FOR DOOR
CLOSE POSITIONING.
2. LATCH: SLIDE LATCH; DOOR STRIKE AND KEEPER WITH RUBBER BUMPER.
~
3. COAT HOOK/BUMPER: CAST ALLOY CHROME PLAYED COMBINATION UNIT.
461 FROM ROAD
MME=qIJ
PARAMUS NJ
07652
4. WALL BUMPER: CAST ALLOY WALL MOUNTED RUBBER BUMPER FOR OUT SWINGING
1� 0
T1973.253.9393
DOORS
WWW.SARGARCH.COM
�<
N
5. PULLS: COMPLY WITH REQUIREMENTS FOR PROVIDING ACCESS FOR PERSONS WITH
DISABILITIES.
�g111111111
I. INTERNAL REINFORCEMENT: PROVIDE INTERNAL REINFORCEMENT IN AREAS OF ATTACHED
`IP.S
0 ; ••"'
HARDWARE AND FITTINGS; MARK LOCATIONS OF REINFORCEMENT FOR PARTITION MOUNTED
p0. 'iU6h� AFoF�i
WASHROOM ACCESSORIES.
3 ¢:
mmi
s
J. PREPARATION: EXAMINE SITE CONDITIONS TO WHICH WORK 15 TO BE APPLIED; TAKE SITE
- '•, SiaiE OTOF
t'•:'am ax4.
;• ,£
DIMENSIONS AFFECTING THIS WORK.
'�'W�UyON
STET' \`Qp.
���q/g1g11111150T���
I. ENSURE CORRECT SPACING AND 51ZE OF PLUMBING FIXTURES; TAKE SPECIAL NOTE
OF FIXTURES IN COMPARTMENTS INDICATED TO BE DESIGNED FOR PERSONS WITH
DISABILITIES TO ASSURE CLEARANCES COMPLYING WITH ACCESS REGULATIONS.
K. INSTALLATION: INSTALL UNITS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS
AND INSTALLATION INSTRUCTIONS, SECURE, PLUMB, LEVEL, AND SQUARE; LEAVE 1/2'
SPACE BETWEEN WALL, PANELS AND END PILASTERS.
1. ADJUST HINGES TO LOCATE DOORS IN PARTIAL OPEN POSITION WHEN UNLATCHED,
Z
EXCEPT ADJUST HINGES TO RETURN DOORS TO CLOSED POSITION AT STALLS
I
DESIGNED FOR USE BY PERSONS WITH DISABILITIES.
CV)
F
aL6
2. ANCHOR URINAL SCREEN PANELS TO WALLS WITH TWO PANEL BRACKETS.
NINO U
V'
D
O
C NI WCNUP OF SCRATCHES AND DEFACED FINISHES WILL NOT BE
L. LEA NG FIELD T
Q'
(0PERMITTED;
REPLACE DAMAGED, SCRATCHED AND MARRED DEFECTIVE MATERIALS WITH
IT-
rn
NEW, UNDAMAGED MATERIALS; REMOVED PROTECTIVE MASKING; CLEAN SURFACES FREE OF
xMP
OIL AND IMPERFECTIONS.
Z
E
LL
O
U
o
SECTION 102M - CORNER GUARDS
O
T
O
A. GENERAL: INSTALL STAINLESS STEEL CORNER GUARDS WITH ATTACHDEVICES AND
Z
0
3MENT
n
�
ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
(�
M
a
Lf)
CL
a
B. MANUFACTURERS: AMERICAN DISPENSER/599, WBRICK/8633, BRADLEY/991 OR PARKER /N0.
LLI
7.
Q
m
to
W
m
C. TYPE: STAINLESS STEEL UNITS WITH SATIN FINISH, 3-1/2' X 3-1/2' X 40 HIGH CORNER
J
L
GUARDS; MINIMUM IB GAGE. PAINT GRIP FINISH AT SALES FLOOR.
Q
N
N
D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS.
V)
L
N
r
r
SECTION =89 - TOILET ACCESSORIES
A. GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED
INSTALLATION.
B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR
ENSURING ACCESS FOR PERSONS WITH DISABILITIES.
C. MANUFACTURERS: BOBRICK, BRADLEY, OR AMERICAN SPECIALTIES. = o IL "s a € a e
D. TYPES: STAINLESS STEEL ACCESSORIES AS INDICATED ON DRAWINGS; PROVIDE GRAB 096P
M.IIE c m o k o W
BARS WITH CONCEALED MOUNTING, SIZES AND SHAPES AS INDICATED AND AS REQUIRED s : 29 � e N o � 6 8 s _
BY APPLICABLE CODES AND REGULATIONS. 8 6 _ 4
�n �y�a gy�=Ua
E. MATERIALS: STAINLESS STEEL ASTI A666, COMMERCIAL GRADE, TYPE 3021304, NUMBER 12= k�,Iliga Bi=1'vZE
o
FRAASSLACCEPTABLE STAINLESS
STEEL LE i = U z
OCCESORRY ITEM SCHEDUED; GAGES AS STANDARD WITH MANUFACTURER OF II`E OOa
SPECIFIED ITEMS. H c € FE:"�a
;�EeiF 5�1fg= Ss €a=
I. FASTENERS, SCREWS, AND BOLTS: HOT DIP GALVANIZED; AS RECOMMENDED BY € a : � 3 a g n : a A a 61 W s g
ACCESSORY MANUFACTURER FOR COMPONENT AND SUBSTRATE. = mEE
911119,
� y � e l
2. CONCEALED SURFACES: PRETREAT AND CLEAN, SPRAY APPLY ONE COAT PRIMER AND '0 7 EI F 3 `II o G i y ic r
BAKED ENAMEL FINISH. ana' Gx�a=s En Sy�;'
15
F. FABRICATION: WELD AND GRIN SMOOTH JOINTS OF FABRICATED COMPONENTS; FORM .Ili & g a ° s x a & 3
EXPOSED SURFACES FROM ONE SHEET OF STOCK, FREE OF JOINTS.
I. FABRICATE UNITS WITH TIGHT SEAMS AND JOINTS, EXPOSED EWES ROLLED; HANG O O o
DOORS AND ACCESS PANELS WITH CONTINUOUS PIANO HINGES; PROVIDE CONCEALED a ut o
ANCHORAGE WHERE POSSIBLE. a
tn�a
2. PROVIDE STEEL ANCHOR PLATES AND ANCHOR COMPONENTS FOR INSTALLATION. 0 N
3. FORM SURFACES FLAT WITHOUT DISTORTION; MAINTAIN FLAT SURFACES WITHOUT T
SCRATCHES AND WITHOUT DENTS; FINISH EXPOSED EWES EASED, FREE OF SHARP
EWES WHERE POTENTIAL EXISTS FOR PHYSICAL CONTACT. T `'
4. HOT DIP GALVANIZE FERROUS METAL ANCHORS AND FASTENING DEVICES. C) le All
5. SHOP ASSEMBLE COMPONENTS; PACKAGE COMPLETE WITH ANCHORS AND FITTINGS. V O o
Oo
G. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES r a W \
AND REGULATIONS.
a caa
w - M
ECTNMI 110511110 - LOCIGRB
m
0
Q
� U O
A. GENERAL INSTALL OWNER FURNISHED METAL LOCKERS; PROVIDE ACCESSORIES AS
O
In
3 0
REQUIRED FOR COMPLETE FINISHED INSTALLATION.
>
o
Nca
m
J
J W
B. INSTALLATION: INSTALL LOCKERS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS
ll.I w
'-`
INSTALLATION INSTRUCTIONS, SECURE, PLUMB, LEVEL, SQUARE, AND IN LINE.
U U
DIDAND
m
iE
Q N
I. BOLT ADJOINING LOCKER UNITS TOGETHER TO PROVIDE RIGID INSTALLATION.
<
K.iR
i
M
� w
ym
o
2
0
^o
2. INSTALL METAL BASES, END PANELS, AND FILLER PANELS TO CLOSE OFF OPENINGS
Z
5
AND AS REQUIRED FOR COMPLETE INSTALLATION.
z
L)w
00
U
0 El
�
a
MHK
dC9ad
SECTION 105= - NOBLE STORAGE WMVMG
J :3 4 o N c
W NU yob
a
A. GENERAL: INSTALL OWNER FURNISHED MOVABLE COMPACT STORAGE SYSTEM; PROVIDE
REVISIONS:
ACCESSORIES AS REWIRED FOR COMPLETE FINISHED INSTALLATION.
REQUIRED BY DATE
B. EXAMINATION: EXAMINE SUBSTRATES AND CONDITIONS UNDER WHICH COMPACTED STORAGE
SYSTEM 15 TO BE INSTALLED. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY
CONDITIONS HAVE BEEN CORRECTED.
C. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION
INSTRUCTIONS.
I. INSTALL UNITS AND ACCESSORIES AT LOCATIONS SHOWN IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS AND INSTALLATIONS INSTRUCTIONS, LEVEL,
PLUMB, SECURE AND AT PROPER HEIGHT.
2. INSTALLATION TO BE SUPERVISED BY FACTORY TRAINED PERSONNEL; MANUFACTURER
DATE ISSUED: 05/31 /201 9
REPRESENTATIVE TO MAKE PERIODIC 51TE INSPECTIONS OF INSTALLATION WHILE IN
DESIGNED BY: JH
PROGRESS.
DRAWN BY: YL
CHECKED BY: YL
D. CLEANING: CLEAN UNITS AND REPAIR OR REPLACE DAMAGED UNITS AS DIRECTED BY
OWNER'S PROJECT MANAGER. TOUCHUP MARRED FINISHES OR REPLACE COMPONENT PARTS
SPECIFICATIONS
AS NECESSARY TO ELIMINATE EVIDENCE OF DAMAGE OR DETERIORATION.
E. PROTECTION: PROVIDE PROTECTION FOR INSTALLED SYSTEM TO ENSURE PERFECT
OPERATING CONDITION WITHOUT DAMAGE AT COMPLETION OF PROJECT.
SECTION 107313 - AWXIGS
DRAWING NUMBER:
A. GENERAL G.C, TO COORDINATE AWNING AND FRAME INSTALLATION WITH OWNER'S PROJECT
MANAGER. SUBCONTRACTOR TO PROVIDE BLOCKING AS REWIRED PER DETAILS.
a,