Loading...
HomeMy WebLinkAboutA101.1 Perimeter Cabinetry Details1 EN PRE -INSTALLED ALIGNMENT BLOCKING GUIDES AT BASE CABINET BELOW RECESSED STANDARDS, TYP. PRE -INSTALLED ALIGNMENT BLOCKING AT UPPER CABINET D PLAN @ HUTCH (BWH-V##-WAL) ILOCATE LED LIGHTING DRIVERS IN UPPER CABINET HEADER — FOR ALL WOOD TM FOR TRW PAINT FINISHES REFER PROFILES REFER TO J/A10.1 TO FLOOR AND WALL FIN18H PLA WHERE APPLICABLE, REFER TO AsS.1 REFER TO QUAD OUTLET FOR LED LI TING, REFER TO POWER PLAN 81 C203mmi X 4 3/8' Immi CUT-OUT AT BACK OF UPPER CABINET, ELEVATION FOR LOCATION 8'-9 13/161, C2 Bmmi A.F.F. T.O. HUTC G.C. TO DRI 1/2' 9 HOLE AT HUTCH TOP PANEL FOR TOP IM LIGHT FIXTURE CONNECTOR WIRE 11/4' 2mm3 ADJUSTABLE SHELVES 17 M ETIC SHELF LIGHT FIXTURE. G.C. T RUN CONNECTOR WIRE THRU SHELF 0 WIRE MANAGEMENT STRIP AT O T BACK OF HUTCH -TYPICAL ALL K MOVEABLE SHELVES AND 70P TRIM aD.I IN -WALL BLOCKING TYP. PI OR F MULTIPLE LOCATIONS ,uz.1yyn1 Aa.lggryry O U A,D11 NC D,EIF G.C. TO SECURE HUTCH TO IN -WALL BLOCKING THROUGIN SHELF STANDARDS AT PRESET HOLES W/ (b) 3 1/2' Main mi #12 SELF TAPPING SHEET METAL SCREWS THRU IN -WALL BLOCKING; IF LONGER SCREW SIZE 15 NEEDED USE #14 17 A I H Li- RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel BWH-V##-WAL) nAVE. F17/1 F/1Q PRE -INSTALLED IGNMENT BLOCKING GUIDES AT BACKS E OF BASE CABINET DRAWER BUNK MTL. STUDS. REFER TO 1.1 FOR REVD STUD SIZE, GA. AND PACING CONTINUE FLOORING UNDER A IRE LEVEL HUTCH AS REQUIRED FI IT ETD FLOOR WALL BASE B-13 1" R T_Qw 428-A10-N00-SECT QI ATTACH DRAWER BUNK CLEAT AT IN -WALL BLOCKING WITH #12 SELF TAPPING SHEET METAL SCREWS AT 12' C3051m11 O.C. O SECURE DRAWER BUNK FROM INSIDE TO BACK WALL AT CLEAT W/ (2) #10 X 3 1/2" 189mm1 LONG METAL SCREWS F 12' [305mm3 O.L. O3 ATTACH CABINET UPPER CLEATS AT IN -WALL BLOCKING WITH #12 SELF TAPPING SHEET METAL SCREWS AT 12" E305mm1 O.C. ® PLACE CABINET UPPER ON DRAWER BUNK AND SECURE AT CLEATS USING #10 X 3 I/2' I&2nm3 LONG METAL SCREWS P PRE-SET COUNTERSUNK HOLE LOCATIONS (USE PRE -FINISHED CAPS PROVIDED BY VENDOR TO CONCEAL SCREW HEADS) SECURE CABINET UPPER/COUNTERTOP ASSEMBLY TO DRAWER BUNK FROM INSIDE USING #10 X 1 1/2' 139mm1 LONG WOOD SCREWS. WALL CABINET INSTALLATION 1/2" - 1'-0" SEQUENCING 420-A1044b041ETL WAD OUTLET BEHIND UPPER PRE -INSTALLED BLOCKING AT UPPER r CABINET HEADER ABOVE, SEE CABINET ATTACHMENT POINTS. SEE SECTION FOR MOUNTING HEIGHT SECTION FOR LOCATIONS I OT lO------------------ -� ....... LINE OF BASE CABINET BELOW CUT-OUT AT BA00.0F UPPER CABINET SHOWN DASHED, TYP. SHELF PLACEMENT VARIES, REFER TO PPL STAGING DOCUMENT PROVIDED BY OWNER WALL FINISH VARIES, REFER TO A05.1 G.C. TO RUN LED 514ELF LIGHT WIRING TO WIRE MANAGEMENT STRIP AT BACKSIDE OF HUTCH LINE OF UPPER CABINET CROWN ABOVE SHOWN DASHED ATION @ HUTCH (BWH-V##-WAL) 1 1/2" %*1.Q 42D-A101-L004)ETL REFlEFL TO RCP B.O. CEILING APPLICABLE, Ego TO AOE.I M OUTLET IN WALL BEHIND LH, REFER TO POWER PLAN FOR EXACT LOCATION METAL BLOCKING BEYOND SHOWN HATCHED. REFER TO DETAIL P/Al2.1 31_3 LAW CI008mm1 A.F.F.JJ,, T.O. CAU-IN TERTOPY 1/2" • T-0" 42E-A101-K00-ELEV TRIM PROFILES (TR5-08 / TRB-O9) SHIPLAP PLANKING 15 PRE -FINISHED ARE PRE -PRIMED BY MANUFACTURER BY MANUFACTURER. G.C. TO TOUCH AND HAND PAINTED IN FIELD BY G.C. UP CUT ENDS AND NAIL HOLES ON REFER TO A05.1 FOR PAINT FINISHES SITE. RffER TO A05.1 FOR FINISHES. b 1 5/8, C41mm] L@®�q 99OLID PCILAR-BO 61'n0 BLOCKING BLOCKING FURN1514ED BY PARTNER FOR INTERNATIONAL STORES 1/2' CGmm1 Q v ` I' [25mn] 3/4' [1.3 R OB R 1 LBiOTH. II' - IT LENDTH. 51 LSBBEA.., - BHI"wma [EwB...N TRANSITIOON TRIM TRANSITION TRIM1TErAL TRIM PROFILE DETAILS �04 � � E 2 3/I611 [56mm1 R O9 09F 1FNGTH�1r LErwTW 12'[BeBd.xna oEEamm1 rP' sa: uw1 a mmev, W+n1"iNBANo� FlNMR-.IomEo CRaNu w roLnwETNeaE RBIBIE .. N Nc CROW N 01; urtTaiFoa(oveaw wN [RNma�uioEo FEoxTs mar) I'PO.PLIS any) FINISHED FACE WD 5 m WD 6-1 M SF M PR6MI&Im PREFINIB PREFINISHm n-IB PT-N CREAMY WHITE F LBGTH. 10' CEMR MIPTP PLANKING DR WD F PREFIN1911Ep mern'Isulm PT-IB PT-19 w INTUMESCENT TweA ENT — L THE 10' [BONB...1 3A, [10mml RenD SHIFT P PLANKING 6" 1' 0" BLOCKING AND DRILL PRAT HOLES FOR ALL SCREW ATTACHMENTS IN . -. .1.1a - .... mfZ7 I. 10 GA. TKAOK TONAL BRACE - SEE STRUCTURAL 41L A/503.01 FOR SIZE N SPACING __--_—_REFER TO RCP J� 6.0. CEILIN CONNECTOR WIRE FOR TOP TRIM LIGHT ERE APPLICABLE) THRU 1/2' 0 -DRILLED HOLE AT TOP OF CABINET ER TO PLUG MOLD AT BACK OF GABLE ._ 81=.{_Ia'_1 553mm1 A.F.F �.0. CFBINET� TO SECURE CABINET UPPER TO IN -WALL :KING USING #10 X 3 V2' 180MMI LONG AL SCREWS F PRE-SET COUNTERSUNK LOCATIONS (USE PRE41NISHED CAPS VIDED BY VENDOR TO CONCEAL SCREW DS) . STUDS. REFER TO N/501.1 FOR 'D STUD SIZE, GA. AND SPACING CH IN GABLE (ON OPPOSITE SIDE) LED SHELF LIGHTING PLUG MOLD, NN DASHED F LIGHTING PLUG MOLD (ON OPPOSITE SIDE) ERE APPLICABLE) ALL BLOCKING TYP. PI OR P2 JLTIPLE LOCATIONS AQ I glz.I [GW SEISMIC An" 50IR'NC CAT A, B[C GT D,E[F I3&mn3 THICK MDF SHELVES -F LIGHTS (WHERE APPLICABLE, SEE 1) - GC TO MOUNT MAGNETIC LIGHTS METAL STRIP AT SHELF AND RUN NECTOR WIRE THRU SHELF TO PLUG D AT BACK OF GABLE - TYPICAL ALL SABLE SHELVES AND TOP TRIM JRE CABINET UPPER/COUNTERTOP A5561BLY DRAWER BUNK (THROUGH BUNK INTERIOR) #0 X 1 1/2' I38mm3 LONG WOOD SCREWS 2_9" 1838mml -__- T.O. COUNTERTOP mI3 a-m.. NSFORMER FOR LED SHELF LIGHTING JRED TO INSIDE OF DRAWER BUNK ERE APPLICABLE) JRE DRAWER BUNK TO BACK WALL IN -WALL METAL BLOCKING WITH (2) X 3 1/2' 15M1m1 LONG METAL ENS F 12' 1305mm1 O.C. WIRE CHASE -OUT AT BACK OF DRAWER BUNK LEX OUTLET FOR LED SHELF LIGHTING ERE APPLICABLE, REFER TO POWER PLAN) EL DRAWER BUNK AS REQUIRED 01_011 FINISHED FLOOR 5E BASE. G.C. TO SCRIBE < 1 TO FIT v-1 1 APPLICABLE, REFER TO OOE.I CUT-OUT AT BACK OF DRAWER BUNK SHOWN DASHED, TYP. REFER TO RCP B.O. CE I Cv 81-4 1/8"' 12553m1ml A.F. F.Js T.O. CA -ME-TY METAL BLOCKING BEYOND SHOWN HATCHED. REFER TO DETAIL P/Al2.1 �Z 461 FROM ROAD ammm9lu PARAMUS NJ 07652 ISERESEW u T1973.253.9393 R WWW.SAROARCH.COM B!✓ a Q CO) Rt a) a Uri U O(0 O 44 N E z j LL OUyX <) O W_ Z T 0 l` Lri i N A� CL v LjJ UD ww � 0) LL J L 0 W 0) CL 0) Cn F- H Wy `s- 552 DG g`€r8 �i+sae y8'Ec� a�s6e &1e_ a gig OR 1'S .0. sss�s b= „gm iEo�e H9 soe i'e nr SjN g�- f N M W O O U O I Y N O d � M V)m a N C838mml A.F. V/ _2_-911 COUNTERTOP - DUPLEX OUTLET IN WALL BEHIND DRAWER BUNK, WHERE T APPLICABLE (ONE OUTLET O `' PER LED POWER SUPPLY). i r1 REFER TO POWER PLAN FOR aM EXACT LOCATION 4e CC o w O 10 F o a z t 01_011 A.F.F. f Y w < w FINISHED FLOOR SECTION @ WALL CABINET 1 1/2" • 1'-0" F I ELEVATION @ WALL CABINET S/a" • 1'-0• BWWC#-V##-XX AND BWWC#-S-V##-XX •+se wTOT Poo aecT o61317 BWWC#-V##-XX AND BWWC#-S-V##-XX 42E-A101 BOO ELEY DUPLEX OUTLET BEHIND DRAWER BUNK BELOW (WHERE APPLICABLE, REFER TO FOR WALL CABINET INSTALLATION POWER PLAN) ONE OUTLET PER LED POWER SEQUENCING SEE DETAIL M/A70.1SUPPLY. SEE SECTION FOR MOUNTING HEIGHT LINE OF WOOD BASE BELOW 8-13 - WALL BASE TO TERMINATE AT SIDES OF DRAWER BUNK — CABINET SIZE LEGEND FIXTURE TAG # OF BAYS OVERALL WIDTH 5WWL2 2 BAY 3'-9' [1143n 3 5WWC3 3 BAY V-0 1I676mml BWW A 4 BAY 7'-3' [22101nm3 BWWCS 5 BAY 9'-O' 12743mm] PLUG MOLD AND E CONNECTORS FOR . SHELF LIGHTING - TYPICAL LEFT SIDE OF EACH CABINET \ 1d` (WHERE APPLICABLE, REFER TO A04.1) i1 PRE -INSTALLED BLOCKING AT BACKSIDE OF CABINET UPPER, G.C. TO PROVIDE IN -WALL BLOCKING - SEE SECTION FOR MOUNTING HEIGHT LINE OF DRAWER BUNK g COUNTERTOP BELOW AIo.I LINE OF DRAWER BUNK BELOW. REFER TO SECTION F/AI0.1 FOR ATTACHMENT AT BACK WALL — J I ENLARGED PLAN @ WALL CABINET - BWWC#-V##-XX AND BWWC#-S-V##-XX I2RAW 12,12.17 1 1/20 11-0" 42D-A101-A00-DETL a EDa J D W � M 00 0 � U m Q E U O O w m 0 `O M a�• M J W Wm w MMM UU m 06az N M BAt Cc 124.17 3 CC F m a da C W } ^ Z L) F U Z L~ U W d O ¢ r U w Q > OW a JIt 1 ••' V�0U In 0'� REVISIONS: REeUIRE] BY; DATE DATE ISSUED: 05/31 /2019 DESIGNED BY: JH DRAWN BY: YL CHECKED BY: YL BBW PERIMETER CABINETRY DETAILS 111.mtulv