HomeMy WebLinkAboutA102 CONSTRUCTION PLANSEMI STUD
W/BATT
INSULLATION
5/8" GYP. BD.
OVER VAPOR
BARRIER
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Carmel
EXISTING
CONSTRUCTION
EXISTING
STOREFRONT
z WINDOW HEAD DETAIL
A1O2 SCALE: 3" = 1'-0"
0 ON 6' 9"
6" MTL. STUD SOLID SURFACE SILL
W/BATT W/EASED EDGE, R=
INSULLATION 1/8"
5/8" GYP. BD.
OVER VAPOR 1"X 21/4'WOOD TRIM
BARRIER BELOW (CHAMFERED'
I \ CORNER BEAD MOLD
SOLID
SURFACE SILL
EXISTING
STOREFRONT
EXISTING
CONSTRU
TION
s WINDOWJAMBDETAIL
Al 2 SCZE: 3 = 1 -0
0 ON 6" 9"
6" MTL.
W/ BATI
INSULLL
5+8" GYI
OVER V
BARRIE
BACKER ROD
EXISTING
STOREFRONT
EXISTING
CONSTRUCTION
a WINDOW SILL DETAIL
A102 SCALE: 3" = 1'-0"
0 3' 6' 9"
CONSTRUCTION PLAN
A102 SCALE: 1/4" 1'-0"
a z a•
GENERAL CONSTRUCTION NOTES:
1, DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD UNLESS NOTED OR SHOWN
OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE IS TO BE VERIFIED BY
2, SEE SHEET A405 FORWALL CONSTRUCTION AND WALL TYPES. ALL INTERIORWALLS ARE TO
BE S3 5B ANDTO EXTEND 6' ABOVE HIGHEST ADJACENT CEILING UNLESS NOTED OTHERWISE.
WALLS AT BUILDING PERIMETERTO BE S64i AND TO EXTEND UPTO FLOOR I ROOF ABOVE.
3 ALL WALLS SHALL BE CHALKED OFF FOR ARCHITECTS REVIEW OF NEW WALL CONSTRUCTION.
4. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL
SURFACE MOUNTED ITEMS.
5 NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN
ONE DOOR OCCURS IN A ROOM, ASUFFIX HAS BEEN ADDED (ie. 1ODA),
6, ALL NEW DOORS TO BE INSTALLED WITH HINGE 6'AWAY FROM WALL UNLESS NOTED OTHERWISE.
7. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND IB"CLEAR ON PULL SIDE OF
DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS.
8, ALL NEW FIRE EXTINGUISHER CABINETS TO BE FINISHED TO MATCH ADJACENT WALL FINISH
AND INSTALLED ACCORDING TO CODE LIFESAFETY CONTRACTOR TO VERIFY PLACEMENT AND
COUNT OF FIRE EXTINGUISHERS THROUGHOUT THE SPACE. IF ADDITIONAL FIRE
EXTINGUISHER LOCATIONS ARE NEEDED, A PLAN MUST BE SUBMITTED TO THE ARCHITECT
FOR REVIEW FOR AESTHETIC PURPOSES ONLY
9, ALL NEW WORK SURFACES TO RECEIVE YGROMMETS. NEW GROMMET LOCATIONS TO BE
VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT GROMMET
COLOR TO BE SELECTED BY ARCHITECT
10, RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH
ARCHITECT
it APPLY SEALANT AT ALL PLUMBING FIXTURES, AT JUNCTURE WITH WALL, ANDATALL
COUNTERTOPS AND BACKSPLASH JUNCTURES.
12, FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES
AS SCHEDULED.
13, ALL WALLS SCHEDULED TO REMAIN(I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE
PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES.
14, USE MOISTURE -MOLD RESISTANT GYPSUM WALLBOARD MEETING ASTM D3273 ON ALL WALL
SURFACES RECEIVING FRP PANELS AND IN RESTROOMS.
15, CEMENT BOARD IS TO BE USED IN ALL SECTIONS AND PORTIONS OF WALLS WITH TILE FINISH.
SEE FINISH PLANS TO COORDINATE FINISH LOCATIONS.
16. SEE A405 FOR DOOR SCHEDULE.
17. ALL PENETRATIONS IN RATED WALL PARTITIONS AND FLOOR SYSTEMS SHALL BE FIRE RATED
ASSEMBLIES. SUBMIT PRODUCT DATA AND ASSEMBLY DRAWINGS WITH TEST FILE NUMBERS
FOR REVIEW.
18, INSULATION FOR INTERIOR WALL APPLICATIONS SHALL BE FORMALDEHYDE -FREE, UNFACED,
GLASS -FIBER BLANKET INSULATION IN BATT FORM CONFORMING TO ASTM C 665, TYPE I, WITH
THICKNESS TO BE EQUAL OR GREATER THAN THE STUD THICKNESS OF THE WALL INTO WHICH
IS IT INSTALLED
19, REPAIR AND PATCH ALL FIRE PROOFING ON THE BUILDING SHELL THAT WAS REMOVED DURING
CONSTRUCTION. REMOVE FIREPROOFING SPRAY FROM THE DECK AND OTHER ITEMS THAT DO
NOT REQUIRE FIRE PROOFING.
CONSTRUCTION PLAN NOTES:
FP1 ALIGN FINISHED FACES.
FP2 CONCRETE COLUMN TO REMAIN UNFINISHED AND EXPOSED.
FP3 ELECTRIC FIREPLACE TO BE: DIMPLEX, PRISM SERIES, BLF5051. CONTACT GODBY HEARTH&
HOME, ADAM MORNS, 317.271.8400 X203.
FP4 PROVIDE 314'k4'x4' FIRE RETARDANT PLYWOOD PHONE BOARD MOUNTED AT G AFF TO
BOTTOM. PHONE BOARDTO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO
MATCH ADJACENT WALL FINISH.
FP5 PROVIDE A WATER METERTO MONITORWATER SUPPLY TO THE SPACE.
FPfi PROVIDE FULL LENGTH WALL MIRRORS AT THIS LOCATION. MOUNT 18"AFF TO BOTTOM, SEE
ELEVATION 71A404. PROVIDE BLOCKING AS NEEDED.
FP7 PROVIDE& INSTALL COMMERCIAL WATER HEATER FOR LAVS,(2) SHOWERS, KITCHEN SINK,
DISHWASHER AND MOP SINK. HANG FROM CEILING, PROVIDE PLATFORM AND DRAIN PAN AS
REQUIRED.
FP8 COMPUTERS AND PRINTERS PROVIDED AND INSTALLED BY TENANT G.C. TO PROVIDE POWER
SOURCE FOR MACHINES. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S
MANUAL.
FP9 INSTALL MOP SINK WI FAUCET. SEE PLUMBING SCHEDULE FOR SPECIFICATIONS. PROVIDE
WALL BLOCKING FOR FAUCET & HOOKS @4'-0" AFF ON (2) WALLS AS REQUIRED. INCLUDE (1)
16" DP 314" PAINTED PARTICLE BOARD SHELF ON WALL CLEATS. SEE ELEVATION ON TA402.
FPt6 PROVIDE AND INSTALL APPLIANCES AS SCHEDULED. PROVIDE WATER SUPPLY, DRAIN AND
ELECTRICAL SERVICE AS REQUIRED. ALTERNATE: INCLUDE KENMORE PRICE. CONTACT DANNI
RIZZO 269,615,3565
FP11 PROVIDE 1/4" COLD COPPER LINES WITH VALVE FOR REFRIGERATOR ICE MAKERAND COFFEE
MAWR. VERIFY EXACT LOCATION OF ALL APPLIANCES REQUIRING A WATER SOURCE WITH
TENANT
FP13 PROVIDE SINGLE BOWL UNDER MOUNT SINK. UNDERCOUNTER GARBAGE DISPOSALTO BE
PROVIDEDAND INSTALLED BY B.C. PROVIDE POWER SOURCE FOR GARBAGE DISPOSAL.
VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. SEE PLUMBING AND
APPLIANCE SPECIFICATIONS ON A405
FPt3 KITCHEN CABINETS TO BE MERILLAT CLASSIC, LANIELLE SQUARE, CAVERN. HARDWARE TO BE
BERENSON, ASPIRE 9237-1BONI BRUSHED NICKEL. SEE ELEVATIONS ON SHEET A403.
ALTERNATE: SMART CABINETS, BRENTWOOD, COFFEE OR MASTER WOOD DRAFT.
FPta PROVIDE PLASTIC LAMINATE_ COUNTER SCRIBED TO WALL. INCLUDE 3'X5-6'BOOKSHELF AND
UNDER COUNTER SUPPORTS AS NEEDED. INCLUDE (3) Y GROMMETS IN COUNTER. SEE
ELEVATION 51A403.
FPtS PROVIDE CONCRETE COUNTER TOPS. INCLUDE WATERFALL EDGE AT PENINSULA AND
OPENING FOR UNDER MOUNT SINK SEE SHEET M03 FOR DETAILS. ALTERNATE: QUARTZ IN
PLACE OF CONCRETE, SEE FINISH LEGEND
FPt6 PROVIDE WATER LINE FOR DRINKING FOUNTAIN WITH BOTTLE FILLER STATION TO BE
ELKAYLZSBWSSP.
FP+T PROVIDE PLASTIC LAMINATE CUBBY WITH 15 EQUAL OPENINGS 4'WIDE X T-6"DEEP.
SEE DETAILS 211
FPtfi PROVIDE& INSTALL FLOOR DRAIN WITH STRAINER FOR RESTROOMS.
FPte (5)18"1314" WHITE MELAMINE SHELVES ON HEAVY DUTY KV 187-7TSTANDARDS & KV 87-1Z'
BRACKETS. SEE DETAIL 8/A403 PROVIDE ADDRIONAL BLOCKING AS REQUIRED.
FFz6 SEE ENLARGED RESTROOM PLAN IIM02 FOR DETAILS. PLUMBING AND ACCESSORY
SPECIFICATIONS ON A405. RESTROOM EXHAUST TO RUN TO EXTERIOR OF BUILDING VIA ROOF
OR NORTH EXTERIOR WALL.
Fes+ EXISTING WINDOW OPENINGS TO BE DRYWALL WRAPPED WITH SOLID SURFACE SILLS. SEE
DETAILS ON A102.
F� NOTUSED.
FPxa BUILDING SHELL: STOREFRONT SYSTEM SEE DOOR SCHEDULE ON A405. PROVIDE EXTERIOR
KEY CODE ACCESS FOR RESIDENTS AND RETAIL TENANTS.
S PROVIDE AND INSTALL BLOCKING FOR WALL MOUNTED TELEVISION. TELEVISIONS ARE TO BE
MOUNTED AT T-0" AFF TO THE BOTTOM. VERIFY IN THE FIELD WITH THE TENANT BEFORE
LOCATING BLOCKING AND ELECTRICAL.
FFze NEW SEMI RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THESE
LOCATIONS WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE.
CONFIRM QUANTITY OF EXTINGUISHERS WITH FIRE DEPARTMENT. IF EXTINGUISHERS NEED
TO BE ADDED VERIFY LOCATIONS WITH THE ARCHITECT
Fri PERIMETER WALLS AT MOVIE AND GOLF ROOMS TO RECEIVE (1) LAYER OF ACOUSTIMAC,
SOUNDLOCK MASS LOADED VINYL IUS SOUNDPROOFING BARRIER ORAPS, SOUNDELOCK,
CONTACT KAREN GUERRETTAZ 317.695.4923 ON INTERIOR SIDE. ON PARTY WALL BETWEEN
ROOMS INSTALL (1) LAYER ON EACH SIDE OF WALL.
FPx1 DEMISING WALL TO RECEIVE (1) LAYER OF ACOUSTIMAC, SOUNDLOCK MASS LOADED VINYL
1US SOUNDPROOFING BARRIER OR APS, SOUNDBLOCK CONTACT KAREN GUERRETTAZ
31T6954923 ON FITNESS SIDE.
FP18 PROVIDE CONTINUOUS BLOCKING ABOVE WINDOWS FOR WALL MOUNTED DRAPERY RODS.
VERIFY HEIGHT IN THE FIELD WITH DESIGNER.
FFze PROVIDE BENCH WI FRONT CLAD WITH WOOD TO MATCH ACCENT WALL. TOP TO BE STAINED
WOOD. SEE DETAIL 411
Fv3o BUILDING SHELL: SEE DOOR SCHEDULE ON A405. PROVIDE EXTERIOR KEY CODE ACCESS FOR
03 rnt NOTE DELETED.
IT I-
GaYCTE>
C 1 ff Y�CEN Ti`E R
PEDCOR DESIGN GROUP LLC
ArchitecWre / Project Management:
355 City Center Drive
Carmel, Indiana 46032
317.705.7979 (phone)
317.705.7980 (fax)
00033126
STATE OF j
KEY PLAN
PARK EAST
S^NE'. MS (P
PUN NORTH
Developer:
P E D C O R
?P Ii3myAW
DEVELOPMENT CO.
Project
0)o
o
MCI
W IN ��
EEEEI
E
u) 00
�m
OLU
Z IN
w (� z M
O
= Z U
Qr�Ln
i 00
00
COP YRIMI OWNERSHIP OF DOCUMENTS
TH S DOCUMENT IS AN ART RUM AT OF DEMAND AND IS THE SUITE
PARMARETY OF I HI JET AND HEADER HEARD DEATH LD ALL
AND
THESE SHOWERS MATTE RESULTED JEROME OR ENTITIES AM
MODIFIED OR G= HE DISTRIMUTED IN AMR My AUTHOR IRE
OJECIFICAND ASIAN ARMED CONSENT AT THE ARCHITECT HARE51
PEDOOR DESIRE GROUT LED C DEEP HER XM
JAMES A HERNANDO AS DATA AM A.
State Release Set
Set Issue Date
Sheet Issue Date
01/03/2019
01/03/2019
Drawn By
Checked By
AAJE
w MD
LasT Revision
Me:
Project Number:
Sheet Title:
CONSTRUCTION
PLAN
INNIMMIND
Sheet Number:
A1(12
DATE: 07/17/19