HomeMy WebLinkAboutLEGACY RIDGE 88 - LR088 (AS DESIGNED)IECC 2009 Performance Compliance Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDGE 88 LR088 (AS DESIGNED) LEGACY RIDGE 88 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,658 $255 $410 $2,324 $922 $0 $3,246 Requirements C-M, Energy Solutions As Designed $1,591 $242 $410 $2,243 $922 $0 $3,165 C4405.3 Performance -based compliance passes by 3.5% R402.4.12 Air Leakage Testing Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 3.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 6118119 at 3:17 PM Ekotrope RATER - Version 3.1.0.2197 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 6790 PULASKI CT CARMEL, IN 46033 Builder: LENNAR HOMES 4Fri MI Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U-Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 308.0 CFM @ 25Pa Total Duct Leakage 411.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 6/18119 at 3:17 PM Ekotrope RATER - Version 3.1.0.2197 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 6790 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (A) Community: LEGACY RIDGE 88 Builder LENNAR HOMES LR088 (AS DES IG NED) LEGACY RIDGE 88 General Building Information Conditioned Area (sq ft) 5,144 Conditioned Volume (cubic ft) 45,306 Insulated Shell Area (sq ft) 8,815 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (1,812 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 161, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 32, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (2,274 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I [ Name: CONDIAMB 2X6 (468 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 6790 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (A) Community: LEGACY RIDGE 88 Builder LENNAR HOMES LR088 (AS DESIGNED) LEGACY RIDGE 88 Name: CONDIGAR (288 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (256 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (296 s.f.) R: 13.575 Name: CONDIGAR (32 s.f.) R: 10.876 Name: CONDIATTIC (32 s.f.) R: 13.575 Roof El Name: MAIN (1,813 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (123 s.f.), U: 0.320, SHGC: 0.28, Orientation: EAST El Name: BACK (210 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST C-M, Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 6790 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (A) Community: LEGACY RIDGE 88 Builder LENNAR HOMES LRO88 (AS DESIGNED) LEGACY RIDGE 88 E] Name: BACK BSMT (11 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST E] Name: SLIDER (40 s.f.), U: 0.280, SHGC: 0.32, Orientation: WEST El !Name: RIGHT SIDE (50 s.f.), U: 0.320, SHGC: 0.31, Orientation: NORTH El Name: LEFT SIDE (94 s.f.), U: 0.320, SHGC: 0.31, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,531 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDGE 88 LR088 (AS DES IG NED) LEGACY RIDGE 88 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 308.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 411.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 6790 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (A) Community: LEGACY RIDGE •C-• Builder LENNAR HOMES LR088 (AS DESIGNED) LEGACY RIDGE 88 Genera?Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 5;144 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 45;306 Total Units in Building 1 Residence Type Single family detached Floor Number Model SOUTHILL (A) Community LEGACY RIDGE 88 Climate Zone 5A C-M, Energy Solutions Foundation Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4ft 1 7 161 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4ft 1 7 32 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R-11 Draped_ Oft 0 4 No N?A NIA 11.00 Slak BSMT Uninsulated 1 Below Grade 0 0 1.812.0 sq. ft. Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame / Other No 0 0 0 No D.00 1 Building Summary Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDGE 68 LR088 (AS DESIGNED) LEGACY RIDGE 88 Wramed Floor Framed Floor Library List Rim Joist Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 296.0 sq.ft. Exposed Exterior CONDIATTIC G1 R-13, R-3.0 32.0 sq. ft. Attic CONDIGAR G1 R-13, OSB 32.0 sq. ft. Unconditioned, attached garage Rim Joist Library Lis Name Effective Insulation R-value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 Name Library Type Surrace COIOr Surtace Area LOCatIOn CONDIAMB G1 R-13 BATT, R-3.0 Medium 2,274.0 sq. fl. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 468.0 sq. fl. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 256.0 sq. fl. Attic CONDIGAR G1 R-13 Gar Walls Medium 288.0 sq. ft. Unconditioned, attached garage 2 Building Summary Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDGE 88 LR088 (AS DESIGNED) LEGACY RIDGE SS FWaliTibrary List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing Inspection Status Results are projected C-M, Energy Solutions Name Library Type Wall Assignment Foundation Wall Overhang Depth Assignment Overhang Ft To Top Overhang Ft To Bottom Orientation Surface Area BACK 111-.32, SHGG.31 CONDIAMB 0 0 0 West 210.0 sq. ft. BACK BSMT 11-.32, SHGG.31 CONDIAMB 0 0 0 West 11.0 sq. ft. FRONT 11-.32, SHGG28 CONDIAMB 0 0 0 East 123.0 sq. ft. LEFT SIDE 11-.32, SHGG.31 CONDIAMB 0 0 0 South 94.0 sq. fL RIGHT SIDE 11-.32, SHGG.31 CONDIAMB 0 0 ❑ North 50.0 sq. fL SLIDER 11-28, SHGG.32 CONDIAMB 0 0 0 West 40.0 sq. ft. Glazing Library List Name U-28, SHGC-.32 U-.32, SHGC-28 11-.32, SHGC-.31 Skylight Shgc U #actor 0.32 0.280 028 0.320 0.31 0.320 9 Building Summary Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDGE 88 LR088 (AS DESIGNED) LEGACY RIDGE 88 kylight Library List I Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Opaque Door Name Library Type Wall Assignmen, FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR Assign ment Opaque Door Library List JL Name Effective U-factor Steel Door 0.182 C-M Energy Solutions Inspection Status Results are projected r Surface Area Location Ab sorpta n ce 0.9 0.75 Medium 20.0 sq- fL Exposed Exterior 0.9 0.75 Medium 18.0 sq- fL Exposed Exterior Roof Insulation M= Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location P.f.] Tiles MAIN R-38 Blown. GR1 7.813 No Medium 1.813-0 sa. fL Attic Roof Insulation Library List Name Has Radiant Barrier Effective R-value '•0 :a l No 38268 Whole House Infiltrati I nfiItration 6 ACH at 50 Pa Blower -door tested 4 M Building Summary Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDG: C-•C-• LR088 (AS DESIGNED) LEGACY RIDGE 88 Mechanical Ventilation Lighting o Interior Fluorescent Lighting Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting Lighting 100 10 tDO Gnsite Generation Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present C-M, Energy Solutions Lighting 0 100 Building Summary Property Organization Inspection Status 6790 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (A) Community: LEGACY RIDG: C-•C-• Builder LENNAR HOMES LR088 (AS DESIGNED) LEGACY RIDGE 88 onditioning Equipment Name Library Type Heating Percent Load Co( Air conditioner (2) CA13NA042 0% C-M, Energy Solutions g Percent Load Hot Water 100% 0% Fuel4red air 915SA4808OS17 100% ❑ % 0% distribution (1) Water Heating (3) RE350" 0% 0% 100% 1 Equipment Type: 915SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 Equipment Type: CA13NA042 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Building Summary Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDG: C-•C-• LR088 (AS DESIGNED) LEGACY RIDGE 88 1bution System Lion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 5144 6 3❑ 3❑ 1041.7 964.5 308 411 Post -Construction Yes Conditioned Space 7❑ 70 Attic (well vented; under insulation) 3❑ 3❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No C-M, Energy Solutions 7 Building Summary Property 6790 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (A) Community: LEGACY RIDGE 88 LR088 (AS DESIGNED) LEGACY RIDGE 88 ater DistributionMM I ter Fixture Type e Default Hot Water Pipe Length t Water Pipe Length [ft] Least R3 Pipe Insulation? t Water Recirculation System? circulation System Pipe Loop Length [ft] in Water Heat Recovery? Clothes Dryer Fuel Type Cef Field utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Standard No 121 No No 20 No Electric Timer Controls glow 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.847 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � C-M, Energy Solutions ,�