HomeMy WebLinkAboutA000.21900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
Suzette Schuette06/13/2016
Right
Lyon
2448.300.00.CPM
Lot 14
06/18/2019
PLOTTED: June 18, 2019 / Vidya / 2448-LYON-MZ-BASE-EL-HR1A.DWG
A3-HR1A
3FB.1Heartland 1A3 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule1210
\A1;2'-2{\H0.750000x;\S7#8;}"
SCALE:FRONT ELEVATION1/4" = 1'-0"-
TOP OF FOUNDATION
WINDOW HEAD HGT.TOP OF PLATE
TOP OF FLOOR
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;5'-0"
12101210
12101210
6:12 6:12
+0+6+0+6
2634 FX
BRICK SOLDIER COURSE, PER SPEC 8" TRIM, PER SPEC 8"x8" CEDAR SQUARE COLUMN
HORIZONTAL SIDING, PER SPEC
4" TRIM BOARD PER SPEC
6" CORNER BOARD, PER SPEC
1x2 OVER 1x10 TRIM BOARD
6" TRIM BOARD, PER SPEC
BLACKOUT WINDOW
FYPON #TRLV60X23 OR APPROVED EQUALFYPON #DTLB6X6X5 OR APPROVED EQUAL, TYP.
SHAKE SIDING, PER SPEC
1x2 OVER 1x10 TRIM BOARD
6" RAKE BOARD, PER SPEC
6" FRIEZE, PER SPEC
ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC
ROOF SHINGLES, PER SPEC
6" CORNER TRIM, PER SPEC
18" SHUTTERS, PER SPEC
FYPON #TRLV60X23 OR APPROVED EQUAL
1x2 OVER 1x6 TRIM BOARD
10:126:12
6:12
\A1;3'-0"
SCALE:ROOF PLAN1/8" = 1'-0"-
\A1;9'-0"
6:12
6:12
10:12
\pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
10:1210:12
\A1;16'-0"\A1;13'-0"
10:1210:12
6:126:12"A"3364ROOF AREA:SQ. FT.
126126
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
\pxql;HORIZONTAL SIDING, PER SPEC
\pxql;ROOF SHINGLES, PER SPEC
\pxql;4" CORNER BOARD, PER SPEC
\A1;WAINSCOT MASONRY WRAP
126126
SCALE:LEFT ELEVATION1/8" = 1'-0"-
TOP OF FOUNDATION
TOP OF PLATE
TOP OF FLOOR
WINDOW HEAD HGT.
\A1;WAINSCOT MASONRY WRAP
126
\A1;7'-8"\A1;HDR. HEIGHT
1210
SCALE:REAR ELEVATION1/8" = 1'-0"-
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
12101210
TOP OF FND
TOP OF PLATE
TOP OF FLOOR
WINDOW HEAD HGT.
\A1;WAINSCOT MASONRY WRAP
126
10" FRIEZE, PER SPEC.
ELEVATION HR1A
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3364 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.49 5.61 5.08 48.41 12 0
AT EAVE 6.73 5.61 5.42 51.59 0 78.00
TOTAL (MIN)11.21 11.21 10.50 100.00
3
HIGH -
RIDGE VENT 4.49 5.61 5.13 48.94 0 0 41.00
AT EAVE 6.73 5.61 5.35 51.06 0 77.00
TOTAL (MIN)11.21 11.21 10.47 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
07/11/19
Adam Schriner