Loading...
HomeMy WebLinkAboutA000.21900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette06/13/2016 Right Lyon 2448.300.00.CPM Lot 14 06/18/2019 PLOTTED: June 18, 2019 / Vidya / 2448-LYON-MZ-BASE-EL-HR1A.DWG A3-HR1A 3FB.1Heartland 1A3 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule1210 \A1;2'-2{\H0.750000x;\S7#8;}" SCALE:FRONT ELEVATION1/4" = 1'-0"- TOP OF FOUNDATION WINDOW HEAD HGT.TOP OF PLATE TOP OF FLOOR \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;5'-0" 12101210 12101210 6:12 6:12 +0+6+0+6 2634 FX BRICK SOLDIER COURSE, PER SPEC 8" TRIM, PER SPEC 8"x8" CEDAR SQUARE COLUMN HORIZONTAL SIDING, PER SPEC 4" TRIM BOARD PER SPEC 6" CORNER BOARD, PER SPEC 1x2 OVER 1x10 TRIM BOARD 6" TRIM BOARD, PER SPEC BLACKOUT WINDOW FYPON #TRLV60X23 OR APPROVED EQUALFYPON #DTLB6X6X5 OR APPROVED EQUAL, TYP. SHAKE SIDING, PER SPEC 1x2 OVER 1x10 TRIM BOARD 6" RAKE BOARD, PER SPEC 6" FRIEZE, PER SPEC ROWLOCK SILL, PER SPECBRICK VENEER, PER SPEC ROOF SHINGLES, PER SPEC 6" CORNER TRIM, PER SPEC 18" SHUTTERS, PER SPEC FYPON #TRLV60X23 OR APPROVED EQUAL 1x2 OVER 1x6 TRIM BOARD 10:126:12 6:12 \A1;3'-0" SCALE:ROOF PLAN1/8" = 1'-0"- \A1;9'-0" 6:12 6:12 10:12 \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. 10:1210:12 \A1;16'-0"\A1;13'-0" 10:1210:12 6:126:12"A"3364ROOF AREA:SQ. FT. 126126 SCALE:RIGHT ELEVATION1/8" = 1'-0"- \pxql;HORIZONTAL SIDING, PER SPEC \pxql;ROOF SHINGLES, PER SPEC \pxql;4" CORNER BOARD, PER SPEC \A1;WAINSCOT MASONRY WRAP 126126 SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF FOUNDATION TOP OF PLATE TOP OF FLOOR WINDOW HEAD HGT. \A1;WAINSCOT MASONRY WRAP 126 \A1;7'-8"\A1;HDR. HEIGHT 1210 SCALE:REAR ELEVATION1/8" = 1'-0"- \A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" 12101210 TOP OF FND TOP OF PLATE TOP OF FLOOR WINDOW HEAD HGT. \A1;WAINSCOT MASONRY WRAP 126 10" FRIEZE, PER SPEC. ELEVATION HR1A ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3364 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.49 5.61 5.08 48.41 12 0 AT EAVE 6.73 5.61 5.42 51.59 0 78.00 TOTAL (MIN)11.21 11.21 10.50 100.00 3 HIGH - RIDGE VENT 4.49 5.61 5.13 48.94 0 0 41.00 AT EAVE 6.73 5.61 5.35 51.06 0 77.00 TOTAL (MIN)11.21 11.21 10.47 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 07/11/19 Adam Schriner