HomeMy WebLinkAboutGN - Childress Approved Truss Plans16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). June 18,2019 Liu, Xuegang Pages or sheets covered by this seal: I37475069 thru I37475093 My license renewal date for the state of Indiana is July 31, 2020. J19902818 Old Town 81 Sunrise IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475069 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-FFcMHD8gc8c6USzRidlWAtfA6owgbH0Wn4_hUfz55fc Scale = 1:55.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 2x4 3x4 4x6 2x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 22-7-0 22-7-0 -1-0-0 1-0-0 11-3-8 11-3-8 22-7-0 11-3-8 23-7-0 1-0-0 0-11-08-5-50-11-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.08 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 19 19 20 19 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 328 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 22-7-0. (lb) - Max Horz 37=-199(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 37, 20, 29, 30, 31, 33, 34, 35, 36, 27, 26, 25, 24, 23, 22, 21 Max Grav All reactions 250 lb or less at joint(s) 37, 20, 28, 29, 30, 31, 33, 34, 35, 36, 27, 26, 25, 24, 23, 22, 21 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 37, 20, 29, 30, 31, 33, 34, 35, 36, 27, 26, 25, 24, 23, 22, 21. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss GE02 Truss Type Common Supported Gable Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475070 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-jRAkUZ9INRkz5cYdGLGlj5CKxBGYKnif0kkE15z55fb Scale: 3/16"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 3x4 4x6 4x6 4x6 3x4 4x6 29-8-0 29-8-0 -1-0-0 1-0-0 14-10-0 14-10-0 29-8-0 14-10-0 30-8-0 1-0-0 0-11-010-9-110-11-08.00 12 Plate Offsets (X,Y)-- [3:0-1-8,0-0-0], [4:0-2-12,0-2-4], [4:0-0-0,0-1-12], [24:0-2-12,0-2-4], [24:0-0-0,0-1-12], [25:0-1-8,0-0-0], [40:0-3-0,0-1-4], [40:0-0-0,0-1-12], [41:0-1-4,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.24 0.10 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.01 0.00 (loc) 27 27 28 27 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 525 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 14-39: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 14-39, 13-41, 12-42, 15-38, 16-37 REACTIONS.All bearings 29-8-0. (lb) - Max Horz 51=254(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 28, 41, 42, 43, 44, 45, 46, 47, 48, 49, 37, 36, 35, 34, 33, 32, 31, 30 except 51=-141(LC 4), 50=-136(LC 5), 29=-101(LC 4) Max Grav All reactions 250 lb or less at joint(s) 51, 28, 39, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 13-14=-21/258, 14-15=-21/258 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 28, 41, 42, 43, 44, 45, 46, 47, 48, 49, 37, 36, 35, 34, 33, 32, 31, 30 except (jt=lb) 51=141, 50=136, 29=101. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss GE03 Truss Type Monopitch Supported Gable Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475071 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-Cdk6ivAw8lsqjm7pp2n_FIkXCbdX3FRpFOToZYz55fa Scale = 1:21.4 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 11 10 9 8 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 6-7-8 6-7-8 0-8-03-5-25.00 12 Plate Offsets (X,Y)-- [2:0-2-3,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.08 0.05 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 1 1 8 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-6-7 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-7-8. (lb) - Max Horz 2=103(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 8, 2, 9, 10, 11 Max Grav All reactions 250 lb or less at joint(s) 8, 2, 9, 10, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2, 9, 10, 11. 8) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss GE04 Truss Type Common Supported Gable Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475072 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-gqIUvFBYv3_hLwi?NmIDoWHiI?ysohFyT2DL5_z55fZ Scale = 1:30.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-0-0 12-0-0 -1-0-0 1-0-0 6-0-0 6-0-0 12-0-0 6-0-0 13-0-0 1-0-0 0-11-04-11-00-11-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.12 0.05 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 11 11 12 11 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 120 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 12-0-0. (lb) - Max Horz 20=-117(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475073 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-80ss6bCAgM6Yy4HCxTpSLjqrePHRX7M6iiyvdQz55fY Scale = 1:63.2 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 2x4 3x4 3x4 4x6 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-6-0 24-6-0 -1-0-0 1-0-0 12-3-0 12-3-0 24-6-0 12-3-0 0-11-09-1-00-11-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.21 0.09 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 0.00 0.00 (loc) 1 1 22 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 375 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 21-22: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-31 REACTIONS.All bearings 24-6-0. (lb) - Max Horz 41=223(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 22, 32, 33, 35, 36, 37, 38, 39, 29, 28, 27, 26, 25, 24, 23 except 41=-115(LC 4), 40=-116(LC 5) Max Grav All reactions 250 lb or less at joint(s) 41, 22, 31, 32, 33, 35, 36, 37, 38, 39, 40, 30, 29, 28, 27, 26, 25, 24, 23 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 32, 33, 35, 36, 37, 38, 39, 29, 28, 27, 26, 25, 24, 23 except (jt=lb) 41=115, 40=116. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss GE06 Truss Type Common Supported Gable Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475074 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-cCQFKxCpRgEOaDrOVBKhtxM0bodkGaaFxMiSAsz55fX Scale: 3/16"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 2x4 3x4 3x4 4x6 3x4 2x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-6-0 24-6-0 -1-0-0 1-0-0 12-3-0 12-3-0 24-6-0 12-3-0 25-6-0 1-0-0 0-11-09-1-00-11-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.20 0.09 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 23 23 24 23 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 376 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 12-33 REACTIONS.All bearings 24-6-0. (lb) - Max Horz 43=-214(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 24, 34, 35, 37, 38, 39, 40, 41, 31, 30, 29, 28, 27, 26, 25 except 43=-108(LC 4), 42=-110(LC 5) Max Grav All reactions 250 lb or less at joint(s) 43, 24, 33, 34, 35, 37, 38, 39, 40, 41, 42, 32, 31, 30, 29, 28, 27, 26, 25 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 34, 35, 37, 38, 39, 40, 41, 31, 30, 29, 28, 27, 26, 25 except (jt=lb) 43=108, 42=110. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss GE07 Truss Type Common Supported Gable Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475075 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-4PzdXHDRC_MFCNQa2uswQ8vCgCzt??XOA0R?iJz55fW Scale = 1:46.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-7-0 14-7-0 -1-0-0 1-0-0 7-3-8 7-3-8 14-7-0 7-3-8 15-7-0 1-0-0 1-1-07-1-151-1-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.09 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 15 15 16 15 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 195 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-7-0. (lb) - Max Horz 28=-171(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except 28=-196(LC 4), 16=-155(LC 5), 27=-197(LC 5), 17=-167(LC 4) Max Grav All reactions 250 lb or less at joint(s) 28, 16, 22, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except (jt=lb) 28=196, 16=155, 27=197, 17=167. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss M01 Truss Type MONOPITCH Qty 7 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475076 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-YbX?ldE3zHV6pX?nccN9yMSHzcFAkV2YOgBZElz55fV Scale = 1:21.0 1 2 3 4 5 3x6 3x8 3x4 3x8 6-7-8 6-7-8 -1-0-0 1-0-0 6-7-8 6-7-8 0-8-03-5-23-1-100-3-83-5-25.00 12 Plate Offsets (X,Y)-- [2:0-4-3,Edge], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.52 0.34 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.16 0.03 0.12 (loc) 5-8 5-8 2 5-8 l/defl >999 >478 n/a >624 L/d 360 240 n/a 240 PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=324/0-3-8, 5=255/0-1-8 Max Horz 2=101(LC 6) Max Uplift 2=-88(LC 6), 5=-97(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-257/112 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T01 Truss Type Common Qty 6 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475077 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-0n5NyyFhkbdzRhazAJuOVZ_PP0WNTwahdKw6mBz55fU Scale = 1:49.3 1 2 3 4 5 6 7 8 11 10 92021 4x6 6x10 4x6 6x10 4x6 3x8 3x4 2x4 3x4 2x4 7-7-3 7-7-3 14-11-13 7-4-11 22-7-0 7-7-3 -1-0-0 1-0-0 5-9-0 5-9-0 11-3-8 5-6-8 16-10-0 5-6-8 22-7-0 5-9-0 0-11-08-5-50-11-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.74 0.67 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.24 -0.38 0.06 0.03 (loc) 9-11 9-11 8 9-11 l/defl >999 >717 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 85 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=979/Mechanical, 2=1042/0-3-8 Max Horz 2=185(LC 5) Max Uplift 8=-37(LC 7), 2=-69(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1300/120, 4-5=-1183/184, 5-6=-1187/185, 6-8=-1304/121 BOT CHORD 2-11=-66/1001, 9-11=0/712, 8-9=-29/1005 WEBS 5-9=-76/507, 6-9=-256/167, 5-11=-74/500, 4-11=-252/166 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T02 Truss Type COMMON Qty 4 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475078 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-0n5NyyFhkbdzRhazAJuOVZ_Rw0XMTwdhdKw6mBz55fU Scale = 1:51.9 1 2 3 4 5 6 7 8 9 12 11 102122 4x6 5x12 4x6 3x8 3x4 2x4 3x4 2x4 5x12 4x6 7-7-3 7-7-3 14-11-13 7-4-11 22-7-0 7-7-3 -1-0-0 1-0-0 5-9-0 5-9-0 11-3-8 5-6-8 16-10-0 5-6-8 22-7-0 5-9-0 23-7-0 1-0-0 0-11-08-5-50-11-08.00 12 Plate Offsets (X,Y)-- [2:0-6-13,Edge], [8:0-6-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.64 0.60 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.24 -0.38 0.07 0.03 (loc) 10-12 10-12 8 10-12 l/defl >999 >710 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1040/0-3-8, 8=1040/0-3-8 Max Horz 2=-177(LC 4) Max Uplift 2=-69(LC 6), 8=-69(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1299/120, 4-5=-1181/183, 5-6=-1181/183, 6-8=-1299/120 BOT CHORD 2-12=-55/999, 10-12=0/710, 8-10=0/999 WEBS 5-10=-74/501, 6-10=-252/166, 5-12=-74/500, 4-12=-252/166 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T03 Truss Type COMMON Qty 5 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475079 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-U_flAIFJVvlq3r99k0Pd2nXdoQplCJPrs_gfJez55fT Scale = 1:67.0 1 2 3 4 5 6 7 8 9 10 11 14 13 1223242526 27 28 3x6 4x6 3x6 6x10 4x6 3x8 4x6 2x4 3x4 2x4 5x12 4x6 9-11-6 9-11-6 19-8-4 9-8-14 29-8-0 9-11-12 -1-0-0 1-0-0 7-6-4 7-6-4 14-10-0 7-3-12 22-1-12 7-3-12 29-8-0 7-6-4 30-8-0 1-0-0 0-11-010-9-110-11-08.00 12 Plate Offsets (X,Y)-- [10:0-6-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.57 0.85 0.39 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.28 -0.43 0.03 0.27 (loc) 12-14 12-14 10 12-21 l/defl >838 >545 n/a >438 L/d 360 240 n/a 240 PLATES MT20 Weight: 118 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-14,8-12: 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-12 REACTIONS.(lb/size)2=1097/0-3-8, 12=1214/0-3-8, 10=700/0-3-8 Max Horz 2=232(LC 5) Max Uplift 2=-128(LC 6), 10=-275(LC 7) Max Grav 2=1097(LC 1), 12=1214(LC 1), 10=706(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1302/289, 4-6=-1149/370, 6-8=-521/540, 8-10=-663/456 BOT CHORD 2-14=-137/1002, 12-14=-57/490, 10-12=-266/491 WEBS 4-14=-397/218, 6-14=-79/858, 6-12=-430/0, 8-12=-425/229 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=128, 10=275. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T04 Truss Type COMMON Qty 8 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475080 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-zAD7NeGxFCthg?kMHkwsa_3iWpBexnU_4ePDr4z55fS Scale = 1:67.0 1 2 3 4 5 6 7 8 9 10 11 14 13 1223242526 27 28 3x6 4x8 3x6 8x10 4x6 3x12 3x6 2x4 3x6 2x4 8x10 4x6 9-11-8 9-11-8 19-8-8 9-9-0 29-8-0 9-11-8 -1-0-0 1-0-0 7-6-4 7-6-4 14-10-0 7-3-12 22-1-12 7-3-12 29-8-0 7-6-4 30-8-0 1-0-0 0-11-010-9-110-11-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.95 0.68 0.34 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.40 -0.66 0.09 0.05 (loc) 12-14 12-14 10 12-14 l/defl >885 >541 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 118 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 8-12,4-14: 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1506/0-3-8, 10=1506/0-3-8 Max Horz 2=232(LC 5) Max Uplift 2=-81(LC 6), 10=-81(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1969/159, 4-6=-1808/241, 6-8=-1808/241, 8-10=-1969/159 BOT CHORD 2-14=-77/1541, 12-14=0/1065, 10-12=-10/1541 WEBS 6-12=-97/821, 8-12=-368/219, 6-14=-97/821, 4-14=-368/219 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T05 Truss Type Common Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475081 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-zAD7NeGxFCthg?kMHkwsa_3sLpG6xra_4ePDr4z55fS Scale = 1:31.1 1 2 3 4 5 6 7 8 3x12 4x6 3x12 4x6 2x4 4x6 6-0-0 6-0-0 12-0-0 6-0-0 -1-0-0 1-0-0 6-0-0 6-0-0 12-0-0 6-0-0 13-0-0 1-0-0 0-11-04-11-00-11-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [6:0-6-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.26 0.33 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.06 0.02 0.04 (loc) 8-11 8-11 2 8-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=540/0-3-8, 6=540/0-3-8 Max Horz 2=-95(LC 4) Max Uplift 2=-51(LC 6), 6=-51(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-500/81, 4-6=-500/81 BOT CHORD 2-8=0/347, 6-8=0/347 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T06 Truss Type COMMON Qty 5 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475082 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-RMnWb_HZ0W?YI8JYrRR57CcwdDX0fG07JI9mNWz55fR Scale = 1:52.9 1 2 3 4 5 6 7 8 9 12 11 102122 3x4 4x6 6x10 4x6 6x10 4x6 3x6 3x4 2x4 3x4 2x4 8-2-13 8-2-13 16-3-3 8-0-5 24-6-0 8-2-13 -1-0-0 1-0-0 6-2-12 6-2-12 12-3-0 6-0-4 18-3-4 6-0-4 24-6-0 6-2-12 0-11-09-1-00-11-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.74 0.67 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.32 -0.50 0.08 0.04 (loc) 10-12 10-12 9 10-12 l/defl >905 >585 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 92 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=1068/Mechanical, 2=1131/0-3-8 Max Horz 2=200(LC 5) Max Uplift 9=-41(LC 7), 2=-72(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1438/131, 4-6=-1308/199, 6-7=-1312/200, 7-9=-1441/132 BOT CHORD 2-12=-72/1109, 10-12=0/783, 9-10=-32/1113 WEBS 6-10=-82/565, 7-10=-283/182, 6-12=-81/559, 4-12=-280/181 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 2. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T07 Truss Type Roof Special Qty 2 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475083 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-vZLuoKICnq7PwIukP9yKfP96Yds8OZqHYyuKvyz55fQ Scale = 1:53.2 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 3x4 4x6 6x8 4x6 5x12 4x6 2x4 2x4 6x10 3x8 2x4 3x8 2x4 4x6 4x10 3x6 8-2-13 8-2-13 14-1-0 5-10-3 19-1-0 5-0-0 21-8-4 2-7-4 24-6-0 2-9-12 -1-0-0 1-0-0 6-2-12 6-2-12 12-3-0 6-0-4 14-1-0 1-10-0 19-1-0 5-0-0 21-8-4 2-7-4 24-6-0 2-9-12 0-11-09-1-00-11-02-0-08.00 12 Plate Offsets (X,Y)-- [2:0-6-13,Edge], [12:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.60 0.74 0.86 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.28 0.16 0.06 (loc) 14-15 14-15 11 14-15 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 110 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-16,8-13: 2x3 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-17 REACTIONS.(lb/size)11=979/Mechanical, 2=1041/0-3-8 Max Horz 2=200(LC 5) Max Uplift 11=-41(LC 7), 2=-72(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1271/134, 4-6=-1138/198, 6-7=-1291/206, 7-8=-1370/138, 8-9=-2476/163, 9-11=-1221/99 BOT CHORD 2-17=-74/981, 14-15=-60/2085, 8-14=0/780, 11-12=-41/930 WEBS 4-17=-299/179, 8-15=-1098/122, 12-14=-46/1191, 9-14=-17/1140, 9-12=-841/62, 15-17=0/855, 6-15=-69/969 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T08 Truss Type COMMON Qty 7 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475084 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-NlvG?gIqY7FGXSTwzsUZCchF61DV7AXQncetSPz55fP Scale = 1:53.4 1 2 3 4 5 6 7 8 9 10 11 14 13 122324 3x4 4x6 3x4 5x12 4x6 3x6 3x4 2x4 3x4 2x4 5x12 4x6 8-2-13 8-2-13 16-3-3 8-0-5 24-6-0 8-2-13 -1-0-0 1-0-0 6-2-12 6-2-12 12-3-0 6-0-4 18-3-4 6-0-4 24-6-0 6-2-12 25-6-0 1-0-0 0-11-09-1-00-11-08.00 12 Plate Offsets (X,Y)-- [2:0-6-13,Edge], [10:0-6-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MS 0.74 0.67 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.33 -0.51 0.08 0.04 (loc) 12-14 12-14 10 12-14 l/defl >898 >580 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1129/0-3-8, 10=1129/0-3-8 Max Horz 2=-192(LC 4) Max Uplift 2=-72(LC 6), 10=-72(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1436/130, 4-6=-1306/199, 6-8=-1306/199, 8-10=-1436/130 BOT CHORD 2-14=-61/1108, 12-14=0/782, 10-12=-1/1108 WEBS 6-12=-81/559, 8-12=-280/181, 6-14=-81/559, 4-14=-280/181 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss T09 Truss Type Common Qty 2 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475085 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-NlvG?gIqY7FGXSTwzsUZCchGT1Hd7BIQncetSPz55fP Scale = 1:44.5 1 2 3 4 5 8 7 6 4x6 3x4 3x4 3x8 6x6 6x6 7-3-8 7-3-8 14-7-0 7-3-8 -1-0-0 1-0-0 7-3-8 7-3-8 14-7-0 7-3-8 15-7-0 1-0-0 1-1-07-1-151-1-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.65 0.40 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.13 0.01 0.00 (loc) 7-8 7-8 6 7-8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 60 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=640/0-3-8, 6=640/0-3-8 Max Horz 8=-171(LC 4) Max Uplift 8=-54(LC 6), 6=-54(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-578/84, 3-4=-578/84, 2-8=-577/117, 4-6=-577/117 BOT CHORD 7-8=-250/332, 6-7=-130/332 WEBS 3-7=0/304, 2-7=-106/269, 4-7=-113/274 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The Fabrication Tolerance at joint 2 = 0%, joint 4 = 0% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 Old Town 81 Sunrise Job Reference (optional) I37475086 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-rxSeD0JSJRN79c17Wa?olqEOKRYtsWta?FNQ_rz55fO Scale = 1:41.7 1 2 3 4 5 6 7 9 810111213 14 15 16 8x10 4x6 4x8 8x10 4x6 10x10 2x4 10x10 2x4 4-11-8 4-11-8 9-7-8 4-8-0 14-7-0 4-11-8 3-9-8 3-9-8 7-3-8 3-6-0 10-9-8 3-6-0 14-7-0 3-9-8 1-1-07-1-151-1-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.84 0.72 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.13 0.03 0.03 (loc) 8-9 8-9 7 8-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 156 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 2-6-9, Right 2x6 SPF No.2 2-6-9 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=3845/0-3-8, 7=4484/0-3-8 Max Horz 1=-157(LC 11) Max Uplift 1=-184(LC 5), 7=-220(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-4306/241, 3-4=-4062/303, 4-5=-4060/305, 5-7=-4299/242 BOT CHORD 1-9=-166/3044, 8-9=-91/2290, 7-8=-120/3047 WEBS 4-8=-200/2552, 5-8=-69/348, 4-9=-196/2556, 3-9=-69/361 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=184, 7=220. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1048 lb down and 53 lb up at 2-0-12, 1048 lb down and 53 lb up at 4-0-12, 1048 lb down and 53 lb up at 6-0-12, 1048 lb down and 53 lb up at 8-0-12, 1048 lb down and 53 lb up at 10-0-12, and 959 lb down and 53 lb up at 12-0-12, and 964 lb down and 50 lb up at 14-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 1-7=-20 Continued on page 2 June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 Old Town 81 Sunrise Job Reference (optional) I37475086 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:37 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-rxSeD0JSJRN79c17Wa?olqEOKRYtsWta?FNQ_rz55fO LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 10=-1048(F) 11=-1048(F) 12=-1048(F) 13=-1048(F) 14=-1048(F) 15=-959(F) 16=-964(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Old Town 81 Sunrise Job Reference (optional) I37475087 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-J700QMK44lV_nmcJ4HW1H1ndrqxBbvCjEv7_WHz55fN Scale = 1:29.4 1 2 3 4 5 6789 10 11 12 6x10 3x4 3x4 4x6 6x10 3x4 3x4 4x10 6-0-0 6-0-0 12-0-0 6-0-0 6-0-0 6-0-0 12-0-0 6-0-0 0-11-04-11-00-11-08.00 12 Plate Offsets (X,Y)-- [1:0-4-8,0-2-0], [5:0-5-13,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.60 0.53 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.13 0.01 0.03 (loc) 5-6 5-6 5 1-6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 112 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 3-6-15, Right 2x4 SPF-S Stud 3-6-15 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=3570/0-3-8, 5=3147/0-3-8 Max Horz 1=105(LC 12) Max Uplift 1=-176(LC 5), 5=-157(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-3366/206, 3-5=-3367/206 BOT CHORD 1-6=-98/2636, 5-6=-98/2636 WEBS 3-6=-121/3475 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=176, 5=157. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 963 lb down and 47 lb up at 0-6-12, 959 lb down and 49 lb up at 2-6-12, 959 lb down and 49 lb up at 4-6-12, 959 lb down and 49 lb up at 6-6-12, and 959 lb down and 49 lb up at 8-6-12, and 959 lb down and 49 lb up at 10-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Old Town 81 Sunrise Job Reference (optional) I37475087 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:38 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-J700QMK44lV_nmcJ4HW1H1ndrqxBbvCjEv7_WHz55fN LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 1-5=-20 Concentrated Loads (lb) Vert: 7=-963(B) 8=-959(B) 9=-959(B) 10=-959(B) 11=-959(B) 12=-959(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss V01 Truss Type Valley Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475088 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-J700QMK44lV_nmcJ4HW1H1ngNq2lb6ljEv7_WHz55fN Scale = 1:31.4 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 11-10-4 11-10-4 11-10-9 0-0-5 5-11-4 5-11-4 11-10-9 5-11-4 0-0-44-11-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.43 0.11 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-9-15. (lb) - Max Horz 1=107(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-112(LC 6), 6=-112(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=295(LC 10), 6=295(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=112, 6=112. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss V02 Truss Type Valley Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475089 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-nKaPeiLir2drOwBVe?1GqFJtGELeKaUtTZsX2kz55fM Scale: 1/2"=1' 1 2 3 43x6 4x6 3x6 2x4 0-0-5 0-0-5 8-8-2 8-7-13 4-4-1 4-4-1 8-8-2 4-4-1 0-0-43-7-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.30 0.19 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=166/8-7-9, 3=166/8-7-9, 4=297/8-7-9 Max Horz 1=-76(LC 4) Max Uplift 1=-16(LC 6), 3=-20(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss V03 Truss Type Valley Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475090 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-FW8nr1MKcMlh03miCiYVMSs3Leio31E0iDc5bAz55fL Scale = 1:16.4 1 2 3 4 2x4 4x6 2x4 2x4 0-0-5 0-0-5 5-5-12 5-5-7 2-8-14 2-8-14 5-5-12 2-8-14 0-0-42-3-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.21 0.13 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=106/5-5-2, 3=106/5-5-2, 4=161/5-5-2 Max Horz 1=45(LC 5) Max Uplift 1=-15(LC 7), 3=-19(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss V04 Truss Type Valley Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475091 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-FW8nr1MKcMlh03miCiYVMSs6Jek031X0iDc5bAz55fL Scale = 1:7.5 1 2 3 2x4 3x4 2x4 0-0-5 0-0-5 2-3-5 2-3-1 1-1-11 1-1-11 2-3-5 1-1-11 0-0-40-11-60-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.02 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-3-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=59/2-2-12, 3=59/2-2-12 Max Horz 1=-14(LC 4) Max Uplift 1=-2(LC 6), 3=-2(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss V05 Truss Type Valley Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475092 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-kii93NMyNgtYeDLulP3kvgPEY22foUB9wtLe7cz55fK Scale = 1:18.4 1 2 3 4 3x6 4x6 3x6 2x4 0-0-6 0-0-6 8-1-7 8-1-1 4-0-11 4-0-11 8-1-7 4-0-11 0-0-42-8-80-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.25 0.16 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=141/8-0-11, 3=141/8-0-11, 4=291/8-0-11 Max Horz 1=55(LC 5) Max Uplift 1=-15(LC 6), 3=-19(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19902818 Truss V06 Truss Type Valley Qty 1 Ply 1 Old Town 81 Sunrise Job Reference (optional) I37475093 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Jun 18 08:52:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:njH48OrSVGbxChUj_v3DQWz569W-kii93NMyNgtYeDLulP3kvgPGu21EoUn9wtLe7cz55fK Scale = 1:9.6 1 2 3 2x4 3x4 2x4 0-0-6 0-0-6 4-1-7 4-1-1 2-0-11 2-0-11 4-1-7 2-0-11 0-0-41-4-80-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.10 0.25 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=126/4-0-11, 3=126/4-0-11 Max Horz 1=-24(LC 4) Max Uplift 1=-5(LC 6), 3=-5(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. June 18,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths