HomeMy WebLinkAboutSHADOW WOOD 7 - SHW007 (AS DESIGNED)IECC 2009 Performance Compliance Property 14473 CARLOW RUN CARMEL, IN 46074 Model: CROIX Community: SHADOW WOOD 7 SHWO07 (AS DESIGNED) SHADOW WOOD 7 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PULTE HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $2,209 $289 $331 $2,830 $1,436 $0 $4,266 Requirements C-M, Energy Solutions As Designed $2,080 $246 $331 $2,657 $1,432 $0 $4,090 C4405.3 Performance-based compliance passes by 6.1% R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 6.1%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 7/2119 at 11:39 AM Ekotrope RATER - Version 3.1.0.2209 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14473 CARLOW RUN CARMEL, IN 46074 Builder: PULTE HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-11 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 300 CFM @ 25Pa (5.081 100 s.f.) Total Duct Leakage 400.0 CFM @ 25Pa Heating Furnace • Natural Gas • 93 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 712119 at 11:39 AM Ekotrope RATER - Version 3.1.0.2209 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 14473 CARLOW RUN TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 Builder SHWO07 (AS DESIGNED) PULTE HOMES SHADOW WOOD 7 General Building Information Conditioned Area (sq ft) 5,908 Conditioned Volume (cubic ft) 49,915 Insulated Shell Area (sq ft) 10,420 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT(2,528 s.f., 243 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 200, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (2,012 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I [ Name: CONDIGAR (299 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 14473 CARLOW RUN TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 Builder SHWO07 (AS DESIGNED) PULTE HOMES SHADOW WOOD 7 El Name: CONDIGAR 2X6 (88 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIATTIC (689 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (224 s.f.) R: 11.691 Name: CONDIGAR (43 s.f.) R: 11.691 Name: CONDIATTIC (95 s.f.) R: 11.691 Roof El Name: SECOND (2,404 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I El Name: SLOPED (94 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 14473 CARLOW RUN TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 Builder SHW007 (AS DESIGNED) PULTE HOMES SHADOW WOOD 7 E] Name: FRONT (72 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST E] Name: BACK (144 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST El Name: LEFT SIDE (4 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH El Name: GD (20 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH El Name: RIGHT SIDE {68 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH Skylight None Present Mechanical Ventilation Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Air Cycler, 8 hrslday, 100 Watts. Mechanical Equipment M Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 93 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: 81 ower -door tested House is air -sealed as to achieve 4,160 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 3 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Energy Code Inspection Checklist Property 14473 CARLOW RUN CARMEL, IN 46074 Model: CROIX Community: SHADOW WOOD 7 SHWO07 (AS DESIGNED) SHADOW WOOD 7 Duct Leakage Duct System 1 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PULTE HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Leakage to Outside specified as: 300 CFM @ 25 Pa. (5.08 / 100 s.f.) Total Duct Leakage specified as 400.0 CFM @ 25Pa (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage t= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property C-MEnergy Solutions Organization Inspection Status 14473 CARLOW RUN TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 Builder SHWD07 [AS DESIGNED] PULTE HOMES SHADOW WOOD 7 enera?Building Informationmber Of Bedrooms 3 mber Of Floors 2 nditioned Floor Area [sq_ ft.] 5;908 conditioned, attached garage? Yes nditioned Volume [Cu. ft.] I 49;915 tal Units in Building 1 sidence Type Single family detached oor Number odel CROIX mmunity SHADOW WOOD 7 mate Zone 5A Foundation Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4Pt 1 7 200 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4Pt 1 7 43 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R -value Cavity R -value Effective Insulation R - Continuous Insulation Continuous Insulation value Top Bottom R-11 Draped_ Oft 0 4 No N?A NIA 11.00 Slak BSMT Uninsulated 243 Below Grade 1.23 0 2,528.0 11:2 Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction SlabCarn le tel Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame/ Other No 0 0 0 No 1).00 1 Building Summary Property 14473 CARLOW RUN CARMEL, IN 46074 Model: CROIX Community: SHADOW WOOD 7 SHW007 [AS DESIGNED] SHADOW WOOD 7 ramed Floor Framed Floor Library List Rim Joist Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PULTE HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Surface Area Location CONDIAMB G1 R-15, OSB 224.9 fF Exposed Exterior CONDIATTIC G1 R-15, OSB 95.0 IFF Attic CONDIGAR G1 R-15, OSB 43.0 IFF Unconditioned, attached garage Rim Joist Library Lis Name Effective Insulation R -value G1 R-15, OSB 11.691 Wall Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 2.012.0 f[' Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 689.0 f[' Unconditioned, attached garage CONDIGAR G1 R-15 Gar Walls Medium 299.0 f[' Unconditioned, attached garage CONDIGAR 2X6 G1 R-19, 2x6 GAR Medium 88.0 ft2 Unconditioned, attached garage Building Summary Property Organization Inspection Status C-MEnergy Solutions 14473 CARLOW RUN TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 Builder SHW007 [AS DESIGNED] PULTE HOMES SHADOW WOOD 7 Wall-ribrary List Name Effective R -value G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 G1 R-19, 2x6 GAR 16218 Glazing �w Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.31, SHGC-28 CONDIAMB 0 0 0 West 144.0 R2 FRONT U-.31, SHGG28 CONDIAMB 0 0 0 East 72.0 f' GD U-.31, SHGG28 CONDIAMB 0 0 0 North 20.0 ft' LEFT SIDE U-.31, SHGC-28 CONDIAMB 0 0 0 South 4.0 fts RIGHT SIDE U-.31, SHGG28 CONDIAMB 0 0 0 North 68.0 ft' Glazing Library List Name Singe U -factor U-.31, SHGC-28 028 0.310 Skylight None Present Skylight Library List None Present 9 Building Summary Property Organization 14473 CARLOW RUN TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 CONDIGAR Builder SHW007 [AS DESIGNED] PULTE HOMES SHADOW WOOD 7 Fopaque Door Surface Area Location Name Library Type Wall Assignmem FRONT Steel Door R-38 Blown. GR1 No CONDIAMB IGARAGE Steel Door CONDIGAR Shelter Class Opaque Door Library List A Name E ndatPon Wall Assignment 0.182 C-M Energy Solutions Inspection Status Results are projected 0.9 0.75 Medium 200 fr Exposed Exterior 0.9 0.75 Medium 18.0 fr Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area P.f.] Tiles Location SECOND R-38 Blown, GR1 2,404 No Medium 2,404.0 ftp Attic SLOPED R-30 Vaulted, GR1 94 No Medium 94.0 f[s Attic Roof Insulation Library List Solar Surface Color Surface Area Location Absorptance 27.186 0.9 0.75 Medium 200 fr Exposed Exterior 0.9 0.75 Medium 18.0 fr Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area P.f.] Tiles Location SECOND R-38 Blown, GR1 2,404 No Medium 2,404.0 ftp Attic SLOPED R-30 Vaulted, GR1 94 No Medium 94.0 f[s Attic Roof Insulation Library List Name Has Radiant Barrier Effective R -value R-30 Vaulted. GR l No 27.186 R-38 Blown. GR1 No 38.268 Whale House Infiltration Infiltration Measurement Type Shelter Class 5 ACH at 50 Pa Blower -door tested 4 M Building Summary Property Organization 14473 CARLOW RUN TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 Builder SHW007 [AS DESIGNED] PULTE HOMES SHADOW WOOD 7 Mechanical Ventilation Ventilation Type Ventilation Rate[fte f Operational hours per Minute] Air Cycler 50 Lighting Interior Fluorescent Lighting C Onsite Generation w None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List Inspection Status Results are projected C-M, Energy Solutions iy Fan Watts Runs once every three Energy Recovery Percent hours 8 700 Yes crescent ! Exterior LED Lighting % Garage Fluorescenl Lighting Lighting 0 0 D Lighting 0 .01 Building Summary Property Organization Inspection Status 14473 CARLOW RUN TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4655 Model: CROIX Michael Hill Community: SHADOW WOOD 7 Builder SHW007 (AS DESIGNED) PULTE HOMES SHADOW WOOD 7 onditioning Equipment Name Library Type Pleating Percent Load Cooling Percent Load Air conditioner (2) 13ACX-036-230 0% 100% I Fuel-fred air ML193UH070XP36B 100% o% distribution (1) IWater Heating (3) RE350` 0% o% 1 Equipment Type: 13ACX-036-230 w==Pw� Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 33.8 Equipment Type: ML193UH070XP3613 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 93AFUE Heating Capacity [kBtulh] 62 Use default EAE Yes EAE [kWh] 555 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 C-M, Energy Solutions r Percent Load Location 0 Unspecified 0% Unspecified 100% Unspecified Building Summary Property 14473 CARLOW RUN CARMEL, IN 46074 Model: CROIX Community: SHADOW WOOD 7 SHW007 [AS DESIGNED] SHADOW WOOD 7 1butivn System tion Type Equipment Equipment t Served i Grilles ]uct R Value ]uct R Value ]uct Area r] ]uct Area [ft2] 5 to Outdoors akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Cfm Per Watt Organization Inspection Status TSI Energy Solutions Results are projected 317-846-4655 Michael Hill Builder PULTE HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 5968 2 30 30 1365.12 505.6 300 CFM @ 25Pa (5.081 100 s.f.) 400 Post -Construction Yes Attic (well vented; under insulation) 90 90 Conditioned Space 10 10 Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No C-M, Energy Solutions 7 Building Summary Property 14473 CARLOW RUN CARMEL, IN 46074 Model: CROIX Community: SHADOW WOOD 7 SHW007 [AS DESIGNED] SHADOW WOOD 7 Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected 317-846-4655 Michael Hill Builder PULTE HOMES Standard No 75 No No 10 No Electric Timer Controls rw 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year "M � C-M, Energy Solutions ,�