HomeMy WebLinkAboutE001.0SCALE:OPT. BASEMENT UNFINISHED UTILITY PLAN1/4" = 1'-0"-
BASEMENT - UNFINISHED
3SS TO LIGHT/SWITCH\PABOVE
GFI
220VOPT. GAS VALVE
GAS VALVEGFI
OPT. ELECTRICAL PANEL (VERIFY LOCATION IN FIELD)
GFIOPT.
GFI
GFIOPT.
G
\pxi-2,l2,ql,t3;{\T0.9;1. ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE (NEC). AND INTERNATIONAL RESIDENTIAL CODE (IRC). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE CURRENTLY ADOPTED EDITION OF THE NEC.\P2. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT.\P3. GFCI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P\pi-3,l5,q*,t6;3.1. BATHROOMS\P3.2. GARAGE\P3.3. OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P3.4. UNFINISHED BASEMENT AREAS AND CRAWL SPACES\P3.5. SINKS LOCATED IN AREAS OTHER THAN A KITCHEN WHERE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF THE OUTSIDE EDGE OF A SINK.\P3.6. RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P3.7. WITHIN 25'-0" AND ON THE SAME LEVEL OF OUTDOOR HEATING, AIR CONDITIONING OR REFRIGERATION EQUIPMENT.\P\pi-2,l2,ql,t3;4. PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN, DINING AND PANTRY AREAS LIMITED TO ONLY THE REQUIRED WALL AND COUNTERTOP OUTLETS, AND THE REFRIGERATOR.\P5. REQUIRED LAUNDRY RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P6. REQUIRED BATHROOM RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P7. ARC-FAULT CIRCUIT INTERRUPTION PROTECTIONS SHALL BE PROVIDED FOR ALL CIRCUITS SUPPLYING POWER TO BEDROOMS.\P8. ALL ELECTRICAL OUTLETS SHALL BE PLACED AT 15" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS NOTED IN THE FOLLOWING NOTES OR ON PLANS.\P9. ALL ELECTRICAL OUTLETS AT KITCHEN COUNTERS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P10. ALL ELECTRICAL OUTLETS AT BATHROOMS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR AT 36" HIGH COUNTERS, AND 41" ABOVE FINISHED FLOOR AT 33" HIGH COUNTERS, UNLESS OTHERWISE NOTED ON PLANS.\P11. ALL SWITCHES SHALL BE PLACED AT 38" TO CENTER OF SWITCH ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P12. ALL WALL MOUNTED LIGHT FIXTURES SHALL BE SET AT A HEIGHT OF 66" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P13. SMOKE DETECTORS:\P\pi-3,l5,q*,t6;13.1. SMOKE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER APPLICABLE CODES. \P13.2. SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER APPLICABLE CODES.\P13.3. INSTALLATION SHALL MEET NFPA 72-70. \P13.4. SMOKE DETECTORS SHALL BE LOCATED ON EACH FLOOR LEVEL IN THE VICINITY OF ALL BEDROOM ENTRANCE DOORS AND WITHIN EACH BEDROOM.\P\pi-2,l2,ql,t3;14. CARBON MONOXIDE DETECTORS:\P\pi-3,l5,q*,t6;14.1. CARBON MONOXIDE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER APPLICABLE CODES.\P14.2. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER APPLICABLE CODES.\P14.3. A CARBON MONOXIDE ALARM IS REQUIRED OUTSIDE EACH SLEEPING AREA AND/OR IN THE IMMEDIATE VICINITY OF SLEEPING AREAS AS REQUIRED BY APPLICABLE CODES.\P14.4. ALL DETECTORS SHALL COMPLY WITH UL2034-2008.\P\pi-2,l2,ql,t3;15. LIGHTING IN CLOTHES CLOSETS SHALL BE:\P\pi-3,l5,q*,t6;15.1. SURFACE MOUNTED OR RECESSED INCANDESCENT OR LED LUMINAIRES WITH COMPLETELY ENCLOSED LIGHT SOURCES\P15.2. SURFACE MOUNTED OR RECESSED FLUORESCENT LUMINAIRES\P15.3. SURFACE MOUNTED FLUORESCENT OR LED LUMINAIRES IDENTIFIED AS SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE\P15.4. INSTALLED PER APPLICABLE CODES. \P15.5. FIXTURES MAY BE LOCATED ONLY WHERE THERE ARE THE FOLLOWING MINIMUM CLEARANCES TO THE NEAREST POINT OF STORAGE SPACE:\P\pi-4,l9,t9;15.1.1. SURFACE MOUNTED INCANDESCENT OR LED FIXTURES: 12" MINIMUM ON WALL ABOVE DOOR OR CEILING\P15.1.2. SURFACE MOUNTED FLUORESCENT FIXTURES: 6" MINIMUM ON WALL ABOVE DOOR OR CEILING\P15.1.3. RECESSED INCANDESCENT OR LED LUMINAIRES WITH COMPLETELY ENCLOSED LIGHT SOURCE INSTALLED IN WALL OR CEILING\P15.1.4. RECESSED FLUORESCENT LUMINAIRES INSTALLED IN WALL OR CEILING\P15.1.5. SURFACE MOUNTED FLUORESCENT OR LED LUMINAIRES SHALL BE PERMITTED TO BE INSTALLED WITHIN THE CLOSET STORAGE SPACE WHERE IDENTIFIED FOR THIS USE.\P15.1.6. FOR CLOSETS 6 SQ. FT. OR LARGER PROVIDE LIGHT IF REQUIRED BY CODE.\P\pi-2,l2,ql,t3;16. NO PARTS OF HANGING FIXTURES, TRACK LIGHTING, AND CEILING PADDLE FANS SHALL BE INSTALLED WITHIN 3'-0" HORIZONTALLY OF A BATHTUB, MEASURED FROM THE OUTSIDE EDGE OF THE TUB AND 8'-0" VERTICALLY FROM THE TOP OF THE TUB RIM.\P17. RECEPTACLES SHALL NOT BE INSTALLED WITHIN A TUB OR A SHOWER ENCLOSURE.\P18. GROUNDING: RECEPTACLE OUTLETS FOR RANGES AND CLOTHES DRYER MUST BE A 3-POLE WITH GROUND TYPE.\P19. AN INTERSYSTEM BONDING TERMINAL SHALL BE PROVIDED FOR GROUNDING COMMUNICATION SYSTEMS (CABLE TV & SATELLITE DISHES).\P20. GROUNDING AND BONDING OF METAL PIPING SYSTEMS SHALL BE PER CODE.\P21. MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT.\P22. VERIFY LOCATION OF ALL RECEPTACLES FOR APPLIANCES WITH MANUFACTURER SPECIFICATIONS.\P23. ALL RECEPTACLES CONTROLLED BY A SWITCH SHALL SPLIT-WIRED TO CONTROL ONLY THE TOP OUTLET\P24. ELECTRICAL CONTRACTOR SHALL VERIFY SPACE REQUIRED FOR METER INSTALLATION BEFORE CONSTRUCTION AND SHALL NOTIFY GENERAL CONTRACTOR OF ANY DISCREPANCIES.\P25. ALL 15 AND 20 AMP RECEPTACLE OUTLETS SHALL BE TAMPER RESISTANT.}UTILITY NOTESUTILITY LEGEND
SYMBOL SYMBOL TYPE ADDITIONAL NOITES
ADDRESS SIGN ADDRESS SIGN - VISIBLE FROM STREET. LETTERS OR NUMBERS FOR THE ADDRESS SHALL BE 4" MIN. IN HEIGHT AND 0.5" MIN. IN STROKE OF A CONTRASTING COLOR TO THE BACKGROUND ITSELF
CHIMES - DOORBELLDETECTOR - HEAT CEILING MOUNTED HEAT DETECTOR TO BE HARD WIRED TO FIRE ALARM SYSTEM (INSTALL PER CODE)
DETECTOR - SMOKE/CARBON MONOXIDE COMBINATION UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - CARBON MONOXIDE UL APPROVED CEILING MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - CARBON MONOXIDE-WALL UL APPROVED WALL MOUNTED CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - SMOKE UL APPROVED CEILING MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR - SMOKE-WALL UL APPROVED WALL MOUNTED SMOKE DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER CODE)
DETECTOR-CARBON MONOXIDE-PLUGIN UL APPROVED WALL PLUG-IN CO DETECTOR WITH BATTERY BACK-UPDISCONNECT - SWITCHEDFAN - CEILING W/ LIGHT FAN BOX PER CODE. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)
FAN - EXHAUST EXHAUST TO EXTERIORFAN - EXHAUST W/ LIGHT EXHAUST TO EXTERIOR12JBOX - PRE-WIRELIGHT - CEILINGLIGHT - CEILING-PULL CHAINLIGHT - FLUORESCENT-48X9LIGHT - FLUORESCENT-PILLOWLIGHT - FLUORESCENT-UNDER CAB-14
LIGHT - FLUORESCENT-UNDER CAB-20
LIGHT - RECESSEDLIGHT - RECESSED-VAPOR PROOFLIGHT - WALLLIGHT - WALL-PULL CHAINMETER - ELECTRIC VERIFY LOCATION IN FIELDOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - DUPLEX-SWITCHEDOUTLET - FLOOROUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONE CAT 5EOUTLET - TV RG-6OUTLET - WATERPROOF-GFIPANEL - ELECTRIC VERIFY LOCATION IN FIELDPANEL - ELECTRIC-RECESSED VERIFY LOCATION IN FIELDPANEL - MEDIA-RECESSED VERIFY LOCATION IN FIELDSWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAYSWITCH - FOUR WAYSWITCH - PUSH BUTTONTHERMOSTAT THERMOSTAT SHALL BE PROGRAMMABLEHOSE BIBBWATER SERVICEGAS VALVEGAS METERRETURN AIR GRILLEWATER METER
HS/C
CC
SS
C
J
PC
14
20RV
PCE220VDW
GFIGFIPHTVWP/GFI
SDISPS3SS4
THBOPT.\PWATER LINEGAS VALVEGR.A.G.W 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2017
RICK STARKEY06/07/2013
GARAGE LEFT
Croix
1993.301
--
08/01/2017
PLOTTED: October 6, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-UTIL.DWG