HomeMy WebLinkAboutGN000.2PLOTTED: October 3, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-COVR.DWG
CZ
0.2 General NotesMidwest ZoneZone Base Plans1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2017
RICK STARKEY06/07/2013
GARAGE LEFT
Croix
1993.301
--
08/01/2017
\A1;{\LGENERAL REQUIREMENTS\P}\P\pxi-2,l2,t2;1. WORK PERFORMED SHALL COMPLY WITH THE FOLLOWING:\P\pi-3,l5,tz;1.1. THESE GENERAL NOTES UNLESS OTHERWISE NOTED ON PLANS OR IN SPECIFICATIONS\P1.2. APPLICABLE NATIONAL CODES (IRC, NEC, IECC ETC.) LATEST ADOPTED EDITION WITH LOCAL AMMENDMENTS\P1.3. ALL APPLICABLE LOCAL AND STATE CODES, ORDINANCES AND REGULATIONS\P1.4. IN AREAS WHERE THE DRAWINGS SPECIFICATIONS OR SCOPES OF WORK DO NOT ADDRESS METHODOLOGY, THE CONTRACTOR SHALL BE BOUND TO PERFORM IN STRICT COMPLIANCE WIITH MANUFACTURER'S SPECIFICATIONS AND/OR RECOMMENDATIONS\P\pi-2,l2,t2;2. ON-SITE VERIFICATIONS OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALE.\P3. THE GENERAL NOTES AND TYPICAL DETAILS APPLY THROUGHOUT THE PROJECT UNLESS OTHERWISE NOTED OR SHOWN.\P4. DISCREPANCIES:\P\pi-3,l5,tz;4.1. THE CONTRACTOR SHALL COMPARE AND COORDINATE ALL DRAWINGS \P4.2. WHEN IN THE OPINION OF THE CONTRACTOR, A DISCREPANCY EXISTS, THE CONTRACTOR SHALL PROMPTLY REPORT IT FOR PROPER RESOLUTION BEFORE PROCEEDING WITH THE WORK.\P\pi-2,l2,t2;5. OMISSIONS:\P\pi-3,l5,tz;5.1. IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE DRAWINGS, THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR NOTED\P5.2. WHERE NO SIMILAR FEATURE OR CONDITION EXISTS THE CONTRACTOR SHALL PROMPTLY REPORT IT FOR PROPER RESOLUTION BEFORE PROCEEDING WITH THE WORK.\P\pi-2,l2,t2;6. ALL WORK IS TO BE PERFORMED IN A PROFESSIONAL MANNER AND IN ACCORDANCE WITH STANDARD PRACTICE AND CONSISTENT WITH MANUFACTURER'S AND SUPPLIER'S RECOMMENDED INSTALLATION PROCEEDURES.\P7. DIMENSIONING:\P\pi-3,l5,tz;7.1. ALL DIMENSIONS SHALL BE READ OR CALCULATED - NOT SCALED\P7.2. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF SHEATHING UNLESS NOTED OTHERWISE\P7.3. ALL DRAWINGS ARE AT A SCALE OF {\H0.7x;\S1#4;}" = 1'-0" UNLESS NOTED OTHERWISE\P7.4. ALL DIMENSIONS AT WINDOWS ARE TO THE CENTERLINE OF THE OPENING.\P\pi-2,l2,t2;8. BEFORE SUBMITTING PROPOSALS, BIDDERS SHALL CAREFULLY EXAMINE THE DRAWINGS, INSPECT THE SITE AND ACQUAINT THEMSELVES WITH ALL GOVERNING CODES, ORDINANCES, REGULATIONS, LAWS, ETC. AND OTHERWISE FAMILIARIZE THEMSELVES WITH ALL MATTERS WHICH MAY AFFECT PERFORMANCE AND COMPLETION OF THE WORK. THE ACT OF SUBMITTING A PROPOSAL SHALL BE CONSIDERED AS MEANING THAT THE BIDDER HAS COMPLIED WITH ALL REQUIREMENTS OF THESE GENERAL NOTES AND SPECIFICATIONS AND THEREFORE NO CONCESSION WILL BE GRANTED BECAUSE OF ANY CLAIM OF MISUNDERSTANDING OR LACK OF INFORMATION.GENERAL NOTES
AFF\PA/C\PALT\PARCH\PBSMT\PBLK\PBLKG\PBD\PBLDG\PCAB\PCPT\PCSMT\PCLG\PCIR\PCIRC\PCLR\PCOL\PCMU\PCONC\PCONST\PCONT\PCJ\PCF\PCY\PDET\PDIA\PDIM\PDW\PDR\PDH\PDS\PELEC\PELEV\PEQ\PEXH\PEXT\PFO\PFIN\PFPL\PFLR\PFD\PFLUOR\PFTG\PFND\PFUR\PGA\PGDO\PGFI\PGFI/WP\PGL\PGYP BD\PHDW\PHDR\PHVAC\PHGT\PHC\PHORIZ\PHB\PINSUL\PINT\PJT\PJST\PKIT\PLAV\PLT\PLNTL\PLVR\PMFR\PMAS\PMATL\PMAX\PMECH\PMC\PMTL\PMIN\PMIR\PMISC\PMOD\PMULL\PNTS\POC\POA\POH\POPT\PPB\PPNL\PPAR\PPED\PPL\PPVC\PPREFAB\PR\PREF\PREFR\PREINF\PRA\PREV\PRD\PRFG\PRM\PRO\PSCHED\PSECT\PSGD\PSHTH\PSHT\PSH\PSIM\PSL\PSC\PSPKR\PSPEC\PSQ\PSTD\PSTL\PSTOR.\PSTRUCT\PTEL\PTV\PTHR\PT&G\PTOC\PTOF\PTYP\PUNF\PUNO\PVERT\PWH\PWC\PWIN\PW/\PW/O\PWD\PWIABOVE FINISH FLOOR\PAIR CONDITIONING\PALTERNATE\PARCHITECT ARCHITECTURAL\PBASEMENT\PBLOCK\PBLOCKING\PBOARD\PBUILDING\PCABINET\PCARPET\PCASEMENT WINDOW\PCEILING\PCIRCLE\PCIRCUMFERENCE\PCLEAR CLEARANCE\PCOLUMN\PCONCRETE MASONRY UNIT\PCONCRETE\PCONSTRUCTION\PCONTINUOUS\PCONTROL OR CONSTRUCTION JOINT\PCUBIC FOOT\PCUBIC YARD\PDETAIL\PDIAMETER\PDIMENSION\PDISH WASHER\PDOOR\PDOUBLE HUNG\PDOWNSPOUT\PELECTRIC ELECTRICAL\PELEVATION\PEQUAL\PEXHAUST\PEXTERIOR\PFACE OF\PFINISH\PFIREPLACE\PFLOOR FLOORING\PFLOOR DRAIN\PFLUORESCENT\PFOOTING\PFOUNDATION\PFURR FURRED FURRING\PGAUGE\PGARAGE DOOR OPENER\PGROUND FAULT CIRCUIT\PGROUND FAULT CIRCUIT-WEATHER PROOF\PGLASS GLAZING\PGYPSUM WALLBOARD DRYWALL\PHARDWARE\PHEADER\PHEATING-VENTILATING-AIR CONDITIONING\PHEIGHT\PHOLLOW CORE\PHORIZONTAL\PHOSE BIBB\PINSULATE INSULATED INSULATION\PINTERIOR\PJOINT\PJOIST\PKITCHEN\PLAVATORY\PLIGHT\PLINTEL\PLOUVER\PMANUFACTURE MANUFACTURER\PMASONRY\PMATERIAL\PMAXIMUM\PMECHANICAL\PMEDICINE CABINET\PMETAL\PMINIMUM\PMIRROR\PMISCELLANEOUS\PMODULAR\PMULLION\PNOT TO SCALE\PON CENTER\POVERALL\POVERHEAD\POPTIONAL\PPUSH BUTTON\PPANEL\PPARTITION\PPEDESTAL\PPLATE\PPOLYVINYL CHLORIDE\PPREFABRICATE PREFABRICATED\PRISER\PREFERENCE\PREFRIGERATOR\PREINFORCE REINFORCED REINFORCING\PRETURN AIR\PREVISIONS REVISED\PROOF DRAIN\PROOFING\PROOM\PROUGH OPENING\PSCHEDULE\PSECTION\PSLIDING GLASS DOOR\PSHEATHING\PSHEET\PSHELF SHELVING SINGLE HUNG WINDOW\PSIMILAR\PSLIDING WINDOW\PSOLID CORE\PSPEAKER\PSPECIFICATIONS\PSQUARE\PSTANDARD\PSTEEL\PSTORAGE\PSTRUCTURAL\PTELEPHONE\PTELEVISION\PTHRESHOLD\PTONGUE AND GROOVED\PTOP OF CONCRETE\PTOP OF FOUNDATION\PTYPICAL\PUNFINISHED\PUNLESS NOTED OTHERWISE\PVERTICAL\PWATER HEATER\PWATER CLOSET\PWINDOW\PWITH\PWITHOUT\PWOOD\PWROUGHT IRONABBREVIATIONS
SCHEDULE of AREAS
BASE HOUSE - HEATED
FIRST FLOOR 2285
SECOND FLOOR 0
TOTAL BASE HEATED 2285
BASE HOUSE - UNDER ROOF
GARAGE - 2 CAR FRONT ENTRY 621
BASEMENT 0
TOTAL BASE UNDER ROOF 2906
BASE OPTIONS - HEATED
BASEMENT 2129
FINISHED LOFT 489
FINISHED LOFT W/ BEDROOM 4 & BATH 4 820
SUNROOM 240
OWNER'S SUITE BAY 16
FINISHED BASEMENT OPTIONS
FINISHED BASEMENT 1670
FINISHED BASEMENT BATH 48
FINISHED BASEMENT BEDROOM 148
ADDITIONAL AREA W/ SUNROOM 1985
MECHANICAL & STORAGE 222
STORAGE 237
0
0
0
BASE OPTIONS
BASEMENT / SUNROOM 2364
COVERED PORCH 240
SCREENED PORCH 240
2-CAR GARAGE W/ 4 FT. EXTENSION 705
2-CAR GARAGE W/ GOLF CART GARAGE 731
WOOD DECK 240
CONCRETE PATIO 242
OTHER 0
LIGHT & VENT SCHEDULE
ROOM NAME AREA
REQUIRED SUPPLIED
LIGHT VENT LIGHT VENT
GATHERING ROOM 414.78 33.18 16.59 51.00 17.70
KITCHEN / CAFE 405.56 32.44 16.22 27.40 11.80
OWNER'S SUITE 274.58 21.97 10.98 51.00 17.70
OWNER'S BATH 107.58 8.61 4.30 ARTIF.MECH.
TOILET ROOM 22.88 1.83 .92 ARTIF.MECH.
BEDROOM 2 209.24 16.74 8.37 27.40 11.80
BATH 2 51.68 4.13 2.07 ARTIF.MECH.
BATH 2 W/ SHOWER 51.14 4.09 2.05 ARTIF.MECH.
FLEX 168.81 13.50 6.75 27.40 11.80
ENTRY / LAUNDRY 87.07 6.97 3.48 ARTIF.MECH.
POWDER 27.11 2.17 1.08 ARTIF.MECH.
HVAC 41.34 3.31 1.65 ARTIF.MECH.
OPT. DEN 168.80 13.50 6.75 27.40 11.80
OPT. BEDROOM 3 148.78 11.90 5.95 13.70 5.90
OPT. FLEX 2 166.19 13.30 6.65 27.40 11.80
OPT. OWNER'S SUITE 2 166.19 13.30 6.65 27.40 11.90
OPT. SUNROOM 234.65 18.77 9.39 64.70 23.60
OPT. OWNER'S BATH 1 90.78 7.26 3.63 ARTIF.MECH.
OPT. OWNER'S BATH 2 107.15 8.57 4.29 ARTIF.MECH.
OPT. OWNER'S BATH 3 106.39 8.51 4.26 ARTIF.MECH.
OPT. OWNER'S BATH 4 108.07 8.65 4.32 ARTIF.MECH.
OPT. OWNER'S BATH 5 108.07 8.65 4.32 ARTIF.MECH.
OPT. OWNER'S BATH 6 108.07 8.65 4.32 ARTIF.MECH.
OPT. FINISHED LOFT 393.61 31.49 15.74 ARTIF.MECH.
OPT. BEDROOM 4 190.56 15.24 7.62 23.40 10.0
OPT. BATH 4 45.21 3.62 1.81 ARTIF.MECH.
OPT. BATH 4 W/ SHOWER 45.21 3.62 1.81 ARTIF.MECH.
OPT. HVAC 40.25 3.22 1.61 ARTIF.MECH.
OPT. FINISHED BASEMENT 1669.7
9 133.58 66.79 ARTIF.MECH.
OPT. FINISHED BASEMENT
BEDROOM 148.45 11.88 5.94 12.20 6.70
OPT. FINISHED BASEMENT BATH 48.36 3.87 1.93 ARTIF.MECH.
OPT. FINISHED BASEMENT BATH
W/ SHOWER 48.13 3.85 1.93 ARTIF.MECH.
OPT. FINISHED BASEMENT W/
SUNROOM
1924.7
9 153.98 76.99 ARTIF.MECH.
0.00 .00 .00
0.00 .00 .00{\Fsimplex|c0;\W0.7;ARTIF. = ARTIFICIAL LIGHT SUPPLIED\PMECH. = MECHANICAL VENTILATION SUPPLIED\PTHIS TABLE SHOWS CALCULATIONS FOR THE BASE HOUSE CONDITION}
2447
2447
07/19/19
William Hohlt