Loading...
HomeMy WebLinkAboutS003.0\A1;4'-0" \A1;54'-0" - OVERALL \A1;46'-0" \A1;21'-0" \A1;67'-0" - OVERALL \A1;4'-0" \A1;57'-0"\A1;6'-0"\A1;67'-0" - OVERALL \A1;13'-8" \A1;20'-4" \A1;20'-0" \A1;54'-0" - OVERALL \A1;21'-0"\A1;12'-0" \A1;54'-0" - OVERALL\A1;19'-0" - ℄ OF OPT. DOOR \A1;2'-0" - ℄ OF OPT. DOOR \A1;10'-0" \A1;10'-0" \A1;10'-0"\A1;20'-0"\A1;27'-0" \A1;7'-0" \A1;6'-8" \A1;21'-4" \A1;16'-0" \A1;℄ OF OPT. DOOR \A1;20'-7{\H0.750000x;\S1#2;}"\A1;5'-0"\A1;20'-4" \A1;5'-0" \A1;4'-0" \A1;2'-4{\H0.750000x;\S1#2;}" \A1;8'-0" \A1;7'-0"\A1;4'-0" \A1;1'-0" \A1;9'-0" \A1;21'-0" - GARAGE \A1;19'-0" - ℄ OF OPT. DOOR \A1;10'-0" \A1;11'-0" \A1;21'-0" \A1;17'-11" \A1;18'-6{\H0.750000x;\S3#4;}" 14" I-JOIST W/ SERIES & SPACING BY MANUFACTURER W8x10 DROPPED CONTINUOUS 14" I-JOIST W/ SERIES & SPACING BY MANUFACTURER \A1;PC 3 (9.5k) W8x10 DROPPED CONTINUOUS 14" I-JOIST W/ SERIES & SPACING BY MANUFACTURER 14" I-JOIST W/ SERIES & SPACING BY MANUFACTURER \A1;PC 3 (9.5k) W8x13 OR W10x12 DROPPED CONTINUOUS \A1;PC 6 (28k) \A1;13'-10{\H0.750000x;\S1#4;}" \A1;5'-6"\A1;9'-5"\A1;7'-0" \A1;15'-0" \A1;10'-11"\A1;12'-4"\A1;11'-9" \A1;3'-8" 14" I-JOIST W/ SERIES & SPACING BY MANUFACTURER 14" I-JOIST W/ SERIES & SPACING BY MANUFACTURERSD.0214 SD.011 SD.011 SD.011 SD.0214 SD.011 SD.015 SD.01 5SD.01 SD.011 SD.0214 SD.0214 SD.011 SD.011 POST ABOVE \A1;12'-11"\A1;OFFSET BEARING WALL ABOVE (550 plf)\A1;OFFSET BEARING WALL ABOVE (550 plf) \A1;4'-2" \A1;\pxql;PIPE COLUMN ABOVE TO BEAR DIRECTLY ON TOP FLANGE OF STEEL BEAM \A1;PC 4 (15k) W8x13 OR W10x12 DROPPED CONTINUOUS W8x13 OR W10x12 DROPPED CONTINUOUS \A1;\pxqc;{\LBASEMENT SLAB\P}-SEE NOTES ON S-0 \A1;(1)1{\H0.7x;\S3#4;}"x14" LVL FLUSH \A1;SIMPSON HU14 HANGER \A1;PC 4 (15.4k)W8x10 DROPPED\A1;PC 1 OR (3)2x4 (5.5k) \A1;PC 2 (6.9k)W8x10 DROPPED CONTINUOUS \A1;{\LNOTE:} OMIT THIS SECTION OF STEEL BEAM W/ INSTALLATION OF OPT. 2x4 @16" O.C. BRG. WALL ON 8"X16" THICKENED SLAB. \A1;{\LNOTE:} OMIT THIS SECTION OF STEEL BEAM W/ INSTALLATION OF OPT. 2x4 @16" O.C. BRG. WALL ON 8"X16" THICKENED SLAB. *\A1;PC 2 (8.0k) W8x10 DROPPED CONTINUOUS W8x10 DROPPED CONTINUOUS \A1;PC 2 (6.5k) POST ABOVE SO-2.5copyright : MULHERN & KULPStructural Engineering, Inc.cissue date: drawn by: project mgr: M&K project number: initial: REVISIONS: date: 09-22-17 JGF DLG 104-17001 Croix ModelIndiana Divisionsheet: VRFARCH REVISIONS10/25/2017 PARTIAL 1st FLOOR FRAMING/FOUNDATION PLAN 1 OPT. 2ND FLOORw/ OPT. BASEMENTELEVATION HR2C SHOWN (ALL ELEV. SIM.)Framing Plan OptionsSCALE: 1/4"=1'-0" (22x34 SHEET)SCALE: 1/8"=1'-0" (11x17 SHEET) 07/19/19 William Hohlt