Loading...
HomeMy WebLinkAboutA000.31012 1012 3:12 SHINGLES PERSUB. SPECS. 9" CROSSHEAD14" PANELED SHUTTERS (TYP.) FYPON LV12x36 OR EQUIV., TYP. SHINGLES PERSUB. SPECS. STONE VENEERPER SPECS9" CROSSHEAD 4" TRIM SURROUND ON DOORSTONE VENEER PER SPECS VERTICAL SIDING PER SPECS STONE SILL6" TRIM BOARD (TYP.)DRIP CAP 9" CROSSHEAD OVER DOOR C L 1012 3:12 20202020 GABLE VENT PER SPEC SHINGLES PER SUB SPECS.SHINGLES PER \PSUB SPECS.FIXEDFIXED WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT 9" CROSSHEAD4" TRIM BOARD4" SILL(SEE PORCH DETAIL)STONE VENEERPER SPECS \A1;1'-1" \A1;2'-11{\H0.750000x;\S5#8;}" \A1;3'-6"\A1;2'-11{\H0.750000x;\S5#8;}" \A1;25'-2{\H0.750000x;\S1#2;}"\A1;6'-0" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;4'-6" A.F.F. SCALE:FRONT ELEVATION1/4" = 1'-0"- BRICK WRAP WINDOW HEIGHT 1st FLR LINE CEILING HEIGHT \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" SCALE:REAR ELEVATION1/8" = 1'-0"- WINDOW HEIGHT 1st FLR LINE CEILING HEIGHT STONE VENEER PER SPECS6" CORNER BD. ON FRONT ELEV. &4" ON SIDES& REAR ELEV.BRICK WRAP 612 612 \A1;1'-1"\A1;1'-1"\A1;2'-0" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;1'-1" SCALE:LEFT ELEVATION1/8" = 1'-0"- \A1;10'-0" \A1;14'-0" \A1;8'-0" \A1;14'-0" SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREA"A"3104 SQ. FT. 10:1210:12 10:1210:12 6:12 6:126:12 10:12 3:12 3:12 6:126:12 ELEVATION CT2H ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3104 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.14 5.17 5.08 49.73 12 0 AT EAVE 6.21 5.17 5.14 50.27 0 74.00 TOTAL (MIN)10.35 10.35 10.22 100.00 3 HIGH - RIDGE VENT 4.14 5.17 6.00 53.87 0 0 48.00 AT EAVE 6.21 5.17 5.14 46.13 0 74.00 TOTAL (MIN)10.35 10.35 11.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE BRICK WRAP 612 \A1;8'-4{\H0.750000x;\S3#8;}"\A1;HDR. HGT. @ 4010 612 SCALE:RIGHT ELEVATION1/8" = 1'-0"- DORMER DETAIL 9" CROSSHEADTRIM BOARD AROUND WINDOW SCALE 1/4" = 1'-0"PORCH ELEVATIONS LEFT PORCHFRONT PORCHRIGHT PORCH 2" CORNER BOARD (TYP)SIDING PER COMM. SPECS (TYP) \A1;5'-4" \A1;2'-7" \A1;8{\H0.750000x;\S1#4;}"\A1;4"\A1;4"1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 SUZETTE SCHUETTE06/07/2013 GARAGE RIGHT Croix 1993.301 LOT 12 06/26/2019 PLOTTED: June 26, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-CT2H.DWG A3 CT2H-2GS.1Cottage 2H - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule07/22/19 Mike Sheeks