HomeMy WebLinkAboutA-019 - LIFE SAFETY DETAILSGYPSUN BOARD SECTION / \ FIRE EXTINGUISHER CABINET A-019 3" = 10-0" ILUMINATED EXITSIGN ;` -1 I MTLSTUDS-SEE PLAN FOR STUD SIZE GYPSUM BOARD RECESSED CABINET ASSEMBLY GYPSUM BOARD NOTE: PROVIDE RATED FIRE CABINET ASSEMBLY WHEN INSTALLED IN RATED WALL. PLAN ILUMINATED EXIT SIGN TACTILE EXIT SIGN � \ F \ o \ LOW LEVEL \ PHOTOLUMINECENT n \ li EXIT SIGN \ 2. 3" `� EXIT Ca GROUND LEVEL 2 EXIT SIGNS A-019 3141, = 1'-0" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel ((�� �vmlUlllw.nJnla�L N DATE: 07/22/19 RETURN TRIM TYP GLASS - 0 Z t w re x O w o O Q Nr z O O f O LL FINISH FLOOR I ELEVATION TACTILE EXIT SIGN \ o \ LOW LEVEL \ PHOTOLUMINECENT to EXIT SIGN \ `� EXIT Ca UPPER LEVELS (a) CORRIDOR EXITS FIRE EXFINGUISHE z m i7 EXIT SIGNS 1013.1 Where Required Exits and exit access tloors shall be marked by an approved exit sign readily visible from any direction of egress travel. The path of egress travel to exits and within exits shall be marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs. Exit sign placement shall be such that no paint in an said access wrndoror exit passageway is more than 100 feet (30480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. Exceptions: 1. Exit signs are not real ired in rooms or areas that require only one exit or exit access. 2. Main exterior exit tloors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the building official. 3. Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1, R-2 or R-3. 4. Exit signs are not required in dayroams, sleeping moms or dormitories in occupancies in Group l-3. 5. In occupancies in Groups A4 and A-5, exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the cencourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. 1013.2 Floor -Level Exit Signs In Group R-1 Where exit signs are required in Group R-1 occupancies by Section 1013.1, additional low-level exit signs shall be provided in all areas serving guest rooms in Group R-1 occupancies and shall comply with Section 1013.5. The bottom of the sign shall be not less than 10 inches (254 mm) nor more than 12 inches (305 mm) above the Boor level. The sign shall be flush mounted to the door or wall. Where mounted on the wall, the edge of the sign shall be within 4 inches (102 mm) of the door frame on the latch ;ine. BASE 4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 wWw.base-4.DGrn RICARDO J. MUNIZ-GULLIET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: j11MuN4, 4 `.p tic z ric 17 16, f"= OF ' 'ufCHFir ec%'0" Owner: �V �IIII THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513.623.9430 HOME SUITES BY HILTON CARMELJNDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA ISSUE DATE I DESCRIPTION 1 JAB 12019.03.04 ISSUED FOR PERMR CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY NP CHECKED BY NIL PROJECTNO. B4-134-1705 SHEET NAME LIFE SAFETY DETAILS DRAWINGS NO. A=019