HomeMy WebLinkAboutA-019 - LIFE SAFETY DETAILSGYPSUN
BOARD
SECTION
/ \ FIRE EXTINGUISHER CABINET
A-019 3" = 10-0"
ILUMINATED EXITSIGN ;`
-1 I
MTLSTUDS-SEE
PLAN FOR STUD SIZE
GYPSUM BOARD
RECESSED CABINET
ASSEMBLY
GYPSUM
BOARD
NOTE:
PROVIDE RATED FIRE CABINET
ASSEMBLY WHEN INSTALLED IN
RATED WALL.
PLAN
ILUMINATED EXIT SIGN
TACTILE EXIT SIGN
� \ F
\ o
\ LOW LEVEL
\ PHOTOLUMINECENT n
\ li EXIT SIGN
\ 2. 3"
`� EXIT
Ca GROUND LEVEL
2 EXIT SIGNS
A-019 3141, = 1'-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Camel ((��
�vmlUlllw.nJnla�L
N
DATE: 07/22/19
RETURN
TRIM
TYP
GLASS -
0
Z
t
w
re
x O
w
o
O Q
Nr z
O
O
f
O
LL
FINISH FLOOR
I
ELEVATION
TACTILE EXIT SIGN
\ o
\ LOW LEVEL
\ PHOTOLUMINECENT
to EXIT SIGN
\
`� EXIT
Ca UPPER LEVELS
(a) CORRIDOR EXITS
FIRE
EXFINGUISHE
z
m
i7
EXIT SIGNS
1013.1 Where Required
Exits and exit access tloors shall be marked by an approved exit sign readily visible from any
direction of egress travel. The path of egress travel to exits and within exits shall be marked by
readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or
the path of egress travel is not immediately visible to the occupants. Intervening means of egress
doors within exits shall be marked by exit signs. Exit sign placement shall be such that no paint in
an said access wrndoror exit passageway is more than 100 feet (30480 mm) or the listed
viewing distance for the sign, whichever is less, from the nearest visible exit sign.
Exceptions:
1. Exit signs are not real ired in rooms or areas that require only one exit or exit access.
2. Main exterior exit tloors or gates that are obviously and clearly identifiable as exits need not
have exit signs where approved by the building official.
3. Exit signs are not required in occupancies in Group U and individual sleeping units or
dwelling units in Group R-1, R-2 or R-3.
4. Exit signs are not required in dayroams, sleeping moms or dormitories in occupancies in
Group l-3.
5. In occupancies in Groups A4 and A-5, exit signs are not required on the seating side of
vomitories or openings into seating areas where exit signs are provided in the cencourse
that are readily apparent from the vomitories. Egress lighting is provided to identify each
vomitory or opening within the seating area in an emergency.
1013.2 Floor -Level Exit Signs In Group R-1
Where exit signs are required in Group R-1 occupancies by Section 1013.1, additional low-level
exit signs shall be provided in all areas serving guest rooms in Group R-1 occupancies and shall
comply with Section 1013.5.
The bottom of the sign shall be not less than 10 inches (254 mm) nor more than 12 inches (305
mm) above the Boor level. The sign shall be flush mounted to the door or wall. Where mounted
on the wall, the edge of the sign shall be within 4 inches (102 mm) of the door frame on the latch
;ine.
BASE 4
BASE4
2901 CLINT MOORE ROAD, #114
BOCA RATON, FLORIDA 33496
888.901.8008 wWw.base-4.DGrn
RICARDO J. MUNIZ-GULLIET, All
5453 NW 106TH DR
CORAL SPRINGS, FL 33076
Seal:
j11MuN4, 4
`.p
tic
z ric
17 16, f"=
OF
' 'ufCHFir ec%'0"
Owner:
�V �IIII
THE WITNESS GROUP
600 ENTERPRISES DRIVE
LEWIS CENTER,OH
513.623.9430
HOME
SUITES BY HILTON
CARMELJNDIANA
PROTOTYPE VERSION-V2.2 2016
REVISION: MAY 2016
DECOR PACKAGE: TRIBECA
ISSUE
NO.
DELTA
ISSUE DATE
I DESCRIPTION
1
JAB
12019.03.04
ISSUED FOR PERMR
CURRENT ISSUE
ISSUED FOR PERMIT
CURRENT ISSUE DATE
2019.03.04
DRAWN BY
NP
CHECKED BY
NIL
PROJECTNO.
B4-134-1705
SHEET NAME
LIFE SAFETY
DETAILS
DRAWINGS NO.
A=019