Loading...
HomeMy WebLinkAboutA-020.a - PARTITION TYPES93/4" 111/4" 103/8" GENERAL NOTES WALL TYPES 5/e"=+�1rz 7sg gyg• 1112" 1" ,�� 5/8' 75/8"l 1/2"-5/8" 41/T ALL GYPSUM BOARD IS TO BE 5/8"THICK UNLESS NOTED 518"GYPSUM WALL OTHERWISE FURRING CHANNEL BOARD 5/8'� 31/2'� t' 71m5/8" RIGID INSULATION INSTALL ACOUSTICAL SEALANT AT ALL GYP BD TERMINATIONS 751B"CMU BLOCKS FURRING CHANNEL - 75/8"CMU BLOCKS 7 5/8" CMU BLOCKS HOLD ALL SUBSTRATE 112"ABOVE CONCRETE TO AVOID 5/e"GYPSUM WALL - WICKING ACTION BOARD 1"AIR GAP " 1 112" FURRING CHANNEL :- :- 1-_. ;- ALL EDGES OF GYP. 60. SHALL BE LOCATED AT AND SECURED 1 1/2" RIGID INSULATION 5/8"GYPSUM WALL - TO FRAMING SUPPORT " 35/8"BRICK VENEER BOARD t- USE PAPERLESS MOISTURE RESISTANT GYP BD (FIRE RATED 518"GYPSUM BOARD IN FIRE RATEDAREAS) INALLWETAREAS. ONWALLSWITH MULTIPLE LAYERS ONY THE OUTERMOST LAYER NEEDS TO - MEET THIS CRITERIA. THIS INCLUOESBUTIS NOTLIMITEO TO: GUEST BATHROOMS -- PUBLIC & STAFF RESTROOMS 0JANITOR CLOSETS T8.1 LAUNDRVAREA -POOL AREAS ..USE CEMENT BOARD BEHIND ALL SHOWERS TUB SURROUNDS & TILED AREAS 2X4 WOOD STUD USE CEMENT BOARD BEHIND ALL EXTERIOR ADHEARED FINISHES PLAN VIEW ON A NON FIRE RATED WALL GYP. BD SHALL TERMINATE 6" PLAN NEW PLAN VIEW FR 4.2 ABOVE THE FINISH CEILING MATERIALS OR CONTINUE TO THE v UNDERSIDE OF THE STRUCTURE ABOVE IF FIRE RATED OR PLAN VIEWS CEILING IS EXPOSED TO STRUCTURE ALL CMU WALL SHALL CONTINUE TO THE UNDERSIDE OF STRUCTURE UNO. FINISHES APPLIED TO THESE WALLS SHALL TERMINATEATTHE FINISH CEILING MATERIAL ORCONTINUE ;;r= ''. TO THE STRUCTURE ABOVE IF THE CEILING IS EXPOSED TO ..::r ...-.. .r r_. STRUCTURE ALL FIRE RATED EXTERIOR WALLS WITH A DISTANCE STAIR. ROOM GREATEER THAN 10' FROM ANOTHER STRUCTURE SHAL BE ELEVATOR LOBBY ELEVATOR SHAFT EXTERIOR INTERIOR z RATED FROM THE INSIDE ONLY / SEE STRUCTURAL PLANS FOR SPACING OF STUDS UNLESS SPECIFICALLY NOTED ELEVATOR INTERIOR WALL 1ST FLOOR EL-8.1 - STAIRCASE. EXTERIOR WALL ST 8.1 — STAIRCASE INTERIOR WALL - ST 8.2 FURRING WALL FR-4.2 PROVIDE FIRE BLOCKING AT FLOORAND ROOF LEVELS, CONCEALED SPACES BETWEEN STAIRWAVSTRINGERS, UL U930 2 HR RATED STC- UL U905 3 HR RATED STC-N/A - UL U905 2 HR RATED STC-N/A -. PENETRATIONS IN FLOOR/CEILING ASSEMBLIES AND OTHER 8 1/4" LOCATIONS AS REQUIRED PER CODE y Lf 1" xl p 1/g^ xl 9 3l8" y y 8 1/4" 3 3/4" FIRE RATED EGRESS CORRIDORS ARE TO BE SEALED WITH 35180 5 112" /g^ 2 5/8" ^ " 1" � 1 1 1, INTUMESCENT SEALING SYSTEMS. RATED WALLS ARE TO BE 5^ � 5/9'"8' 5/b 1/2 351 � �I z. 1 1/4 SEALED TO DECK. VERTICAL JOINTS AT CMU/GYPSUM BOARD 3 5/8" BRICK VENEER U - WALLS ARE TO BE SEALED BOTH SIDES. WALL PENETRATIONS - - SUCH AS BAR JOISTS, PIPING, CONDUIT, DUCTWORK, ETC. ARE FLUID APPLIED TO BE SEALED PER FIRE STOP MANUFACTURER'S WEATHER BARRIER 1"AIR GAP 1"AIR GAP RECOMMENDATIONS. 11/2" RIG ID INSULATION 398"BRICK VENEER 398"THICK BRICK PROVIDE BLOCKING AT ALL WALL HUNG EQUIPMENT AS REQUIRED AND DETAILED IN DRAWINGS. COORDINATE EXACT 5/8"GYP. BD. MOISTURE 518"GYP. BO. MOISTURE FLUID APPLIED LOCATION WITH ARCHITECTIOWNER/TENANT. RESISTANT RESISTANT WEATHER .MAXIMUM HEIGHT OF NON LOAD BEARING WALL ABOVE !� TPO MEMBRANE BARRIER HEADER TO BE 20'1 — REFERENCE CAPTURE TRACK DETAILS FOR DEFLECTION TPO MEMBRANE 5l8"EXTERIOR WOOD_ REQUIREMENTS. 2x6 WOOD STUD FLUID APPLIED SHEATHING METAL STUD WALLS RECEIVING PLYWOOD SHALL BE 22 1' AIR GAP WEATHER BARRIER 5/8" GYP. BD. MOISTURE FIBERGLASS BLANKI GAUGE OR HEAVIER. PRE.1 RESISTANT PROVIDE HORIZONTAL BRACING FOR METAL STUDS AT 1/3 & 2 5l8" EPS 2/3 OF WALL HEIGHT 2 518^ EPS 518" TYPE X GYPEQ SHEATHINGOD 1 1/2" C-H METAL ST GENERAL NOTES:STC NOTES zxs 2x6 WOOD STUD WOOD STUD zxswooDsruD � LANwew PLAN VIEW PLAN VIEW PLAN VIEW SOUND ATTENUATION REQUIREMENTS EMPLOY THE BEST PRACTICES OUTLINED BY THE AMERICAN SOCIETY OF TESTS AND MEASURES (ASTM), SECTION E-497 TO ENSURE GOOD SH21 SOUND CONTROL; CONFER WITH GYPSUM WALLBOARD MANUFACTURERS FOR SPECIFIC RECOMMENDATIONS ON HOW BEST IMPLEMENT THEIR SYSTEMS TO OPTIMIZE SOUND CONTROL R-6.3 1"TYPE X LINER PANEL- THE ENTIRE PERIMETER OF SOUND -INSULATING ASSEMBLIES SHALL BE AIRTIGHT, SO AS TO ELIMINATE FLANKING PATHS 1"TYPE X LINER PI THROUGH WHICH SOUND CAN TRAVEL; SOUND -INSULATING 7PR-6.2 ASSEMBLIES THEMSELVES SHALL BE AIRTIGHT - NO HOLES OR EXTERIOR INTERIOR EXTERIOR INTERIOR Ll SHAFT ROOM HAIRLINE CRACKS ARE ALLOWED, AS THEVWOULD CREATE FLANKING PATHS FOR SOUND EXTERIOR INTERIOR / APPLY ACOUSTICAL SEALANT BETWEEN SOUND INSULATING PARAPET WALL1 AIR SHAFT WALL SH4.1 ASSEMBLIES AND OTHER DISSIMILARASSEMBLIES,OR BETWEEN SOUND INSULATING ASSEMBLIES AND SIMILAR PARAPET WALL PR 6.2 PARAPET WALLZ PR 6.1PR 6.3 U428 2 HR RATED SURFACES, WHERE PERIMETER RELIEF IS REQUIRED. TAPING AND CAULKING OF GYPSUM WALLBOARD AND WALL/CEILING INTERSECTIONS WILL PROVIDE AN ADEQUATE SEAL AT THESE y4 1/4" 77 1/4" 7 112" 5 318" LOCATIONS 5/8'3 S/8' 5/8"� /2'�6 5 1/2 5/A 1/2" 1/2". 5 1/I 1 5/8" 111 3 WB' RECESSED WALL FIXTURES, SUCH AS CABINETS, OUTLETS AND OTHER ITEMS THAT PENETRATE THE GYPSUM WALLBOARD SURFACE SHALL NOT BE LOCATED BACK-TO-BACK IN THE SAME STUD CAVITY. ANY OPENINGS FOR SUCH FIXTURES SHALL BE 18" TYPE X GYPED... CAREFULLY CUT TO SIZE AND CAULKED -........ /8" TYPE X GYP.BO. 3 518" METAL STUD L 1/2' RESILIENT CHANNEL 2" RESILIENT CHANNEL WALL TYPE ABBREVIATIONS 5f8"TYPE X GYP.BD. EX= EXTERIOR - - ER= EXTERIOR RATED 3 5t8" METAL STUDS CR= CORRIDOR GD= GUESTROOM DEMISING `518' GYPSUM BOARD R-0 a ST= STAIRS CM= CMU WALL CN= CONCRETE WALL 35/8"METAL STUDS FH-FIRE SEPERATION 1/2" RESILIENT CHANNEL iP= INTERIOR PARTION . 3 5r6' METAL STUDS 1R= INTERIOR PARTITION RATED FR= FURRING _FIR 518" TYPE X GYP.BD. ... PR= PARAPET WALL 4.1 SH= SHAFT WALL PLAN VIEW STRUCTURAL SHEATHING - - - COORDINATE WITH STRUCTURAL DRAWINGS ON LOCATIONS IN THE R-64 R-4.2 R QUIRINURALSHTURAL S EATHINGWALLS SAME PLANE REQUIRING STRUCTURAL SHEATHING, GC IS TO FURR OUT SO P11 FINAL FINISHES PLANE OUT /I TYPE X GVP BD /8" TYPE X GYP.BD. NOTE: RELEASED FOR CONSTRUCTION 1.FOR FINISH LEGEND REFER TO SHEET G-0OS ///�///7�, `LRIxO EXTERIOR INTERIOR EXTERIOR INTERIOR. n SudjecHocompliancewithall regulations EXTERIOR INTERIOR of State and meal Codes City of Camel INTERIOR A I I N WALL 1HR RATED INTERIOR.PARTITION WALL 2HR RATED INTERIOR PARTITION WALL IR-6.1 IR 6.2 IR42 UL U914 2HR RATED STC-50 ULU914 2HR RATED STC-50 P11III to DATE: 07/22/19 BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base4.00m RICARDO J. MUNIZ-GULLIET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: %%%" 51111,1nIUN�'x'xxxgai 7 %N 4D.. GIBTE/kO 1700161 :m_ OF u/CH ITI�G41`�. ' fill, OwnerOFF t, I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513.623.9430 HOME SUITES BY HILTON CARMEL,INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA ISSUE DATE DESCRIPTION 1 JAD 12019.03.04 JISSUEDFORPERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY NP GHECKa D BY NIL PROJECTNO. -- 134-134-1705 SHEET NAME PARTITION TYPES DRAWINGS NO. A=020.a