HomeMy WebLinkAboutA-021 - FLOOR TYPES1 /8"TYPE X GYP.BD. 1/2" RESILIENT CHANNEL 1ST FLOOR/CORRIDOR F 2 TYPICAL FLOOR GUESTROOM 3HR UL J924 iHR UL P545 STC = 66 ' STC = 55 ROOFING 5/8" RIGID INSULATION BLOWN IN INSULATION OPEN WEB TRUSS RESILIENT CHANNEL TYPE X GYP.BD. F-3 TYPICAL CORRIDOR FLOOR UPPER FLOOR iHR UL L 516 STC = 66 ROOF R-1 1 HR UL P 545 BATT INSULATION '.STC =55 TPO ROOFING MEMBRANE PARTICLEBOARD RIGID INSULATION --2X10 JOIST L 3/4" D ®FLOOR III II II II - 1 1 I 1 \ 5(1 TYPE X GYP.BD RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City NCamel x DATE: 07/22/19 GENERAL NOTES WALL TYPES ALL GYPSUM BOARD IS TO BE 5/8" THICK UNLESS NOTED OTHERWISE INSTALL ACOUSTICAL SEALANT AT ALL GYP BD TERMINATIONS HOLD ALL SUBSTRATE 1/2" ABOVE CONCRETE TO AVOID WICKING ACTION ALL EDGES OF GYP. BD. SHALL BE LOCATED ATAND SECURED TO FRAMING SUPPORT USE PAPERLESS MOISTURE RESISTANT GYP BD (FIRE RATED IN FIRE RATED AREAS) IN ALL WET AREAS. ON WALLS WITH MULTIPLE LAYERS ONY THE OUTERMOST LAYER NEEDS TO MEET THIS CRITERIA. THIS INCLUDES BUT IS NOT LIMITED TO: GUEST BATHROOMS PUBLIC& STAFF RESTROOMS. JANITOR CLOSETS LAUNDRY AREA -POOL AREAS .USE CEMENT BOARD BEHIND ALL SHOWERS, TUB SURROUNDS B TILED AREAS USE CEMENT BOARD BEHIND ALL EXTERIOR ADHEARED FINISHES ON A NON FIRE RATED WALL GYP. BD SHALL TERMINATE 6" ABOVE THE FINISH CEILING MATERIALS OR CONTINUE TO THE UNDERSIDE OF THE STRUCTURE ABOVE IF FIRE RATED OR CEILING IS EXPOSED TO STRUCTURE ALL CMU WALL SHALL CONTINUE TO THE UNDERSIDE OF STRUCTURE UNO. FINISHES APPLIED TO THESE WALLS SHALL TERMINATE AT THE FINISH CEILING MATERIAL OR CONTINUE TO THE STRUCTURE ABOVE IF THE CEILING IS EXPOSED TO STRUCTURE .ALL FIRE RATED EXTERIOR WALLS WITH A DISTANCE GREATEER THAN 10' FROM ANOTHER STRUCTURE SHAL BE .RATED FROM THE INSIDE ONLY SEE STRUCTURAL PLANS FOR SPACING OF STUDS UNLESS SPECIFICALLY NOTED PROVIDE FIRE BLOCKING AT FLOOR AND ROOF LEVELS, CONCEALED SPACES BETWEEN STAIRWAY STRINGERS, PENETRATIONS IN FLOORICEILING ASSEMBLIES AND OTHER LOCATIONS AS REQUIRED PER CODE FIRE RATED EGRESS CORRIDORS ARE TO BE SEALED WITH INTUMESCENT SEALING SYSTEMS. RATED WALLS ARE TO BE SEALED TO DECK. VERTICAL JOINTS AT CMU/GYPSUM BOARD WALLS ARE TO BE SEALED BOTH SIDES. WALL PENETRATIONS SUCH AS BAR JOISTS, PIPING, CONDUIT, DUCTWORK, ETC. ARE TO BE SEALED PER FIRE STOP MANUFACTURER'S RECOMMENDATIONS. PROVIDE BLOCKING AT ALL WALL HUNG EQUIPMENT AS REQUIRED AND DETAILED IN DRAWINGS. COORDINATE EXACT LOCATION WITH ARCHITECT/OWNER/TENANT. .MAXIMUM HEIGHT OF NON LOAD BEARING WALL ABOVE HEADER TO BE 20'-0" REFERENCE CAPTURE TRACK DETAILS FOR DEFLECTION REQUIREMENTS. METAL STUD WALLS RECEIVING PLYWOOD SHALL BE 22 GAUGE OR HEAVIER. PROVIDE HORIZONTAL BRACING FOR METAL STUDS AT 1/3 & 213 OF WALL HEIGHT GENERAL NOTES STC NOTES SOUND ATTENUATION REQUIREMENTS EMPLOY THE BEST PRACTICES OUTLINED BY THE AMERICAN SOCIETY OF TESTS AND MEASURES (ASTM), SECTION E497 TO ENSURE GOOD SOUND CONTROL; CONFER WITH GYPSUM WALLBOARD MANUFACTURERS FOR SPECIFIC RECOMMENDATIONS ON HOW BEST IMPLEMENT THEIR SYSTEMS TO OPTIMIZE SOUND CONTROL THE ENTIRE PERIMETER OF SOUND -INSULATING ASSEMBLIES SHALL BE AIRTIGHT, SO AS TO ELIMINATE FLANKING PATHS THROUGH WHICH SOUND CAN TRAVEL; SOUND -INSULATING ASSEMBLIES THEMSELVES SHALL BE AIRTIGHT— NO HOLES OR HAIRLINE CRACKS ARE ALLOWED, AS THEY WOULD CREATE FLANKING PATHS FOR SOUND APPLY ACOUSTICAL SEALANT BETWEEN SOUND INSULATING ASSEMBLIES AND OTHER DISSIMILAR ASSEMBLIES, OR BETWEEN SOUND INSULATING ASSEMBLIES AND SIMILAR SURFACES, WHERE PERIMETER RELIEF IS REQUIRED. TAPING AND CAULKING OF GYPSUM WALLBOARD AND WALL / CEILING INTERSECTIONS WILL PROVIDE AN ADEQUATE SEAL AT THESE LOCATIONS RECESSED WALL FIXTURES, SUCH AS CABINETS, OUTLETS AND OTHER ITEMS THAT PENETRATE THE GYPSUM WALLBOARD SURFACE SHALL NOT BE LOCATED BACK-TO-BACK IN THE SAME STUD CAVITY. ANY OPENINGS FOR SUCH FIXTURES SHALL BE CAREFULLY CUT TO SIZE AND CAULKED WALL TYPE ABBREVIATIONS EX= EXTERIOR ER= EXTERIOR RATED CR= CORRIDOR GD= GUESTROOM DEMISING ST= STAIRS CM-- CMU WALL CN= CONCRETE WALL FS= FIRE SEPERATION IP= INTERIOR PARTION IR= INTERIOR PARTITION RATED FR= FURRING PR-- PARAPET WALL SH= SHAFT WALL STRUCTURAL SHEATHING COORDINATE WITH STRUCTURAL DRAWINGS ON LOCATIONS OF STRUCTURAL SHEATHING. WALLS IN THE SAME PLANE REQUIRING STRUCTURAL SHEATHING, GC IS TO FURR OUT SO ALL FINAL FINISHES PLANE OUT OPTION 1: R-3.8d + R-20 BATT INSULATION NOTE: FLOORIMPACT 1.SUrrE TO SUITE -SSIIC 2.SUrrE SLEEPING AREA TO MECHANICAL ROOM -SSIIC FLOOR ASSEMBLY HAS AN PROPER TIC RATING BAS F. BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 w .base-4.00m RICARDO J. MUNIZ-GULLIET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: -........ 11 uN1U 7 ``OpNu� . U�OOPEGISTE/kO 1700161 OF DIANP. -. •��`` ' 'u/CHITI�G41`�. Owner /V�•�iI THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513.623.9430 HOME SUITES BY HILTON CARMEL,INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA I ISSUE DATE DESCRIPTION 1 AO 12DI9.M.04 ISSUED FOR PERM IT CURRENTISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY NP CHECKED BY NL PROJECTNO. - B4-134-1705 SHEET NAME FLOOR TYPES DRAWINGS NO. A=021