HomeMy WebLinkAboutA-034 - FIRE RATED WALL DETAILSDesign No. J924
November 19, 2018
Restrained Assembly Ratings s-2 3and 4 Hr.
See item 1 and 2
UnrThis design
Assembly Rating g a Hr.
This tlesign was Working
Stress
using i In M design method other than the Limit States Design
Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States
Design Method, such as Canada, a load restriction factor shall be usetl - See Guide
BXUV or BXUV]
` Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions
employing the UL or cUL Certification (such as Canada), respectively.
1 4 q I
141
x�^,nnn,r- nnnni� �1�
J� VVUUUUuuuu C�
I I
I
Restrained
End Detail
Unrestraineo
End Detail
1. Concrete Topping - Normal -Weight aggregate, 3000 psi compressive strength, 110 to 153
per unit weight.
Concrete topping is required for the following units only:
Rating Hr
Unit
Thk In.
Topping
Thkns In.
2
8
0
3
8
1
4
8
1-112
2
10
0
3
10
0
4
1 10
1
1A. Floor Topping Mixture' - Altemate to Item 1 - Min 3/4 in. thickness of floor topping mixture
having a min compressive strength of 1100 psi. Mixture shall consist of 6.8 gal of water to 801bs
of floor topping mixture to 1.9 cu ft of sand.
Floor Topping Mixture is required for the following units only:
Rating Hr
Unit
Thk In.
Topping
Thkns In.
2
8
0
3
8
1/2
4
8
3/4
2
10
0
3
10
0
a
1 10
1n
HACKER INDUSTRIES INC Firm -Fill Gypsum Concrete, Fiml-Fill 2010, Firm -Fill 3310, Firm -Fill
4010, Gyp -Span Radiant
Floor Mat Materials - (Optional) - Floor met material nom 1/8 in. (3 men) thick loose laid over
the precast concrete unit. Floor topping thickness shall be a min of 3/4 in. (19 rum).
HACKER INDUSTRIES INC FIRM -FILL SCM 125
Alternate Floor Mat Materials - (Optional) - Floor mat material nom 1/4 in. (6 mm) thick
loose laid over the precast concrete unit. Floor topping thickness shall be a min of 1 in. (25 men).
HACKER INDUSTRIES INC Type FIRM -FILL SCM 250
Alternate Floor Mat Materials - (Optional) - Floor mat material nom 3r8 in. (10 men) thick
loose laid over the precast concrete unit. Floortopping thickness shall be a min of 1-1/4 in. (32
mm)
HACKER INDUSTRIES INC FIRM -FILL SCM 400
Alternate Floor Mat Materials - (Optional) - Floor mat material nom 314 in. (19 mm) thick
loose laid overthe precast concrete unit. Floortopping thickness shall be a min of 1-1/2 in. (38
men).
HACKER INDUSTRIES INC Type FIRM -FILL SCM 750
Metal Lath (Optional)- For use with 318 in. (10 men), or greater, floor mat maleriab, 3/8 in.
expanded steel diamond mesh, 3.4lbs/sq yd placed over the floor mat material. Hacker Floor
Primer to be applied prior to the placement of the metal lath. W hen metal lath is used, floor
topping thickness a nom 1 in. (25 men) over the floor mat.
1B. Floor Topping Mixture' -Alternate to Items 1 and 1A- Floor topping mixture having a min
compressive strength of 1100 psi. Mixture shall consist of 6.8 gal of water to 80 lbs of floor
topping mixture to 1.9 cu ft of sand. Thickness per table.
HACKER INDUSTRIES INC Firm -Fill Gypsum Concrete, Firm -Fill High Strength, Gyp -Span
Radiant
Floor Mat Materials` - (Optional) - Floor mat material nom 5t64 in. (2 mm) thick adhered to
precast concrete unit with Hacker Floor Primer. Primer to be applied to the surface of the mat
prior to the placement of floor -topping mature. Floor topping thickness a min 1 in. over the floor
mat.
ECORE INTERNATIONAL INC -Type QTscu 4002
HACKER INDUSTRIES INC - Type Hacker Sound -Mat
Alternate Floor Mat Materials - (Optional) - Floor mat material nom 1/4 in. (6 mm) thick
adhered to precast concrete unit with Hacker Floor Primer. Primer to be applied to the surface of
the mat prior to the placement of a min 1-1/4 in. (32 men) of floor -topping mature.
ECORE INTERNATIONAL INC - Type QTmm 3006-3
HACKER INDUSTRIES INC - Type Hacker Sound -Mat 11
Metal Lath (Optional)- For use with 3/8 in. (10 men) floor mat materials, 3/8 in. expanded steel
diamond mesh, 3.4lbs/sq ytl placed over the floor mat material. Hacker Floor Primer to be
applied prior to the placement of the metal lath. When metal lath is used, floor topping thickness
a nom 1-1A in. over the floor mat.
1C. Alte mate Fl nlsh Fl ood rig - Floor Topiel rig Mixture' - Min. 3/4 in. thickness of floor
topping mixture having a minimum compressive strength of 1500 psi. Refer to manufacturers
instructions accompanying the material for specific ma design.
Floor Topping Mixture is required for the following units only:
Unit Topping
Rating Hr Thk In. Thkns In.
2 8 0
3 8 112
4 8 314
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel ((��
�vmlU)llanrJnalJ�L
N
DATE: 07/22/19
MAXXON CORP - Type D-C, GC, GC 2000, L-R, T-F, CT, SS
RAPID FLOOR SYSTEMS - Types RE, REP, RFU, Odecrete
Floor Mat Materials` (Optional) - Floor mat material loose laid over the subfloor. Refer to
manufacturer's instructions regarding the minimum thickness of floor topping over each floor mat
material.
MAXXON CORP - Type Acousti-Matt/B Acousti-Matt/4 Acousti-Mat 1/4Premium, Acousti-
Mat r MAcousti-Matme Premium, Acousti-Mat 3/4, Acousti-Mat tru Premium, Acousti-Top.
Floor Mat of
topping
for use
witnalph
- Reffloor
mat
manufacturers instructions regarding minimum
thickness of floor topping for use with floor mat reinforcement.
Metal Lath (Optional)- 98 i expanded galvanized steel diamond mesh, 3.41bs/sq ytl loose
laid over the floor mat material.
Fiber Glass mesh,
0.368
.3ro Revea-(Optional,Not Shown)-0. mat in. thick PVC coated non -woven
fiberglass mesh, 0.3681bs/sq ytl loose laid over the floor mat material.
1D. Alternate Floor Topping Mixture'- Compressive strength to be 1800 psi minimum. Refer
to manufacturer's instructions accompanying the material for specific mix design.
Floor Topping Mixture is required for the following on As only:
Rating Hr
Unit
Thk In.
Topping
Thkns In.
2
8
0
3
8
1/2
4
8
3/4
2
10
0
3
10
0
4
10
1 2
UNITED STATES GYPSUM CO -Type CSD, LRK, HRLRK
USG MEXICO S A DE C V - Types LRK, HSLRK, CSD
Floor Mat Materials' - (Optional) - Floor mat material loose laid over the subfloor. Refer to
man ufactu refs instructions regarding the minimum thickness of floor topping over each floor mat
material.
UN RED STATES GYPSUM CO -Types SAM, LEVELROCK® Brand Sound Reduction Board,
LEVELROCK® Brand Floor Underlayment SRM-25
Alternate Floor Mat Materials•- (Optional) - Floor mat material nom 3/8 In. thick loose laid
over the subfloor. Floor topping thickness a min 3/4 in. over the floor mat.
G RASSWORX L L C-Type SC50
1E. Alternate Floor Toppl ng Mixture' - Compress Ne strength to be 1000 psi min. Thickness
to be 3/4 in. min. Refer to manufacturers instm ctions accompanying the material for specific mix
design.
Floor Topping Mixture is required for the following on its only:
Rating
Hr
Unit
Thk In.
Topping
Thkns In.
2
8
0
3
8
1/2
4
8
314
2
10
0
P43
10
0
10
1l2
ADD MATERIALS -Attu-Crete types NexGen, Green, Prime, B, M, and PrePour,
Accu Radiant, Accul-evel types G40, SD30, and G50.
Alternate Floor Mat Material` - (Optional) - Floor mat material nominal 2 - 9.5 men thick loose
laid over the subfloor. Floor topping shall be a min of 3/4 in.
ACG MATERIALS - AccuQuiet types P80, C40, D13, D-18, D25, DX38, EM.125, EM.125S,
EM.250, EM.2508, EM.375, EM.3758, EM.750, and EM.750S.
1 F. Alternate Floor Topping Mixture'- Compressive strength to be 1000 psi min. Thickness
to be 3/4 in. min. Refer to manufacturer's instructions accompanying the material for specific mix
design.
Floor Topping Mixture is required for the following units only:
Rating
Hr
Unit
Thk In.
Topping
Thkns in.
2
8
0
3
8
1/2
4
8
314
2
10
0
3
1 10
0
4
1 10
1/2
FORMULATED MATERIALS LLC -Types FR-25, FR-30, SiteMix, and SIteMIx SL
Alternate Floor Mat Material'- (Optional) - Floor mat material nominal - 9.5 men thick loose
laid over the subfloor. Floor topping shall be a min of 3/4 in.
FORMULATED MATERIALS LLC -Types Ml, M2, M3, R1, and R2
1G. Alternate Floor Topping Mixture'- Compressive strength to be 2100 psi min. Thickness
to be 3/4 in. min. Refer to manufacturer's instructions accompanying the material for specific mix
design.
Floor Topping Mixture is required for the following units only:
Rating Hr
Unit
Thk In.
Topping
Thkns In.
2
8
0
3
8
112
4
8
518
2
10
0
3
10
0
4
10
1/2
2. Precast Concrete Units'-8, 10 and 12 in. thick units. Normal weight aggregate. Cross-
section similar to the above illustration. For 12 inunits, the Rating is 4 his with or without a
topping. When units are made without core holes, the Rating is 4 him with or without a topping.
CONEWAGO BUILDING SYSTEMS L L C
KERKSTRA PRECAST INC
SPANCRETE INDUSTRIES INC
SPANCRETE NORTHEAST INC
3. End Details - Restrained and unrestrained.
4. Grout - Sand cement type, 3500 psi compressive strength.
5. Min Bearing- 1-1/2 in. for assembly rating of 3 hror less and 3 in. for assembly rating of 4
hr.
' Indicates such products shall bear the UL or cUL Certification Markfor jurisdictions
employing the UL or cUL Certification (such as Canada), respectively.
Design No. X528
October 24, 2017
Ratings -1, 2 and 3 Hr.
'Intlicates such products shall hearths UL or cUL Certification Mark for jurisdictions
employing the UL or cUL Certification (such as Canada), respectively.
CORNER DETAILS OF WALLBOARD
SUPPORT SYSTEMS WITHOUT STEEL COVERS
1. Steel Column - Min sires of W-shaped and tubularsteel columns which appear in the AISC
Steel Construction Manual as shown under Item 2.
2. Gypsum Boartl' - Any 112 in. thick UL Classified Gypsum Board that is eligible for use
In Design No. X515. Any 518 in. thick UL Classified Gypsum Board that is eligible for use in
Design Nos. L501 G512 or U305. Nora 1 /2 in. or 518 in. thick sum board. Applied in layers
9 gypsum PP Ye
as noted in the above ayers in inc Boards are to be u applied a di min without horizontal joints.
Min total thickness of layers in inches for the various ratings and min column sizes are as
follows:
W Shaped
Column
Min Column
Rating (No
Comer Details For Various Rating
Size
1
1 2
1 3
1 1Hr
2Hr
3Hr
Total thickness (in.)
w4z1a
1
1-12
z-v4
e
c
D
wax l5s
1
1-112
12-114
e
I c
I D
W18x49
1/2
1-1/e
1 1181
A
IB
I C
Tube Shaped columns
TS4by4
beel
1
1.314
2-5/8
B
C
D
TS8by8
by a 259
1 but
1 1-11212-1141
A
c
D
ACADIA DRYWALL SUPPLIES LTD Subscrbr ID+and+CKNX'+CCN"(View Classification) -
CKNX.R2637O
AMERICAN GYPSUM CO Subscrbr ID+and+CKNX'+CCN"(View Classification)
-
CKNX.R14196
BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO
Subscrbr ID+and+CKNX'+CCN"(View Classificotion)-CKNX.R19374
CERTAINTEED GYPSUM INC Ell ID+antl+CKNX'+CCN"(ViewClassification) -
CKNX.R3660
CDC INC Subscrbr ID+and+CKNX'+CCN"(View Classification)-CKNX.R19751
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C
Subscrbr ID+antl+CKNX'+CCN"(View Classification)-CKNX.R18482
GEORGIA-PACIFIC GYPSUM L L C Subscrbr ID+and+CKNX'+CCN"(ViewClassification) -
CKNX.R2717
LOADMASTER SYSTEMS INC Subscrbr ID+antl+CKNX"+CCN"(View Classification) -
CKNXR11809
NATIONAL GYPSUM CO Subscrbr ID+and+CKNX'+CCN"(View Classification) - eXP-C,
CKNX.R36O1
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM
Subscrbr ID+and+CKNX`+CCN"(View Classificetion)-CKNX.R7094
PANEL REY S A Sulcutr ID+antl+CKNX'+CCN"(View Classification) -CKNX.R21796
SIAM GYPSUM INDUSTRY (SARABURI) CO LTD Subscrbr ID+antl+CKNX'+CCN"(View
Classification) - CKNX. R19262
THAI GYPSUM PRODUCTS PCL Subscrbr ID+antl+CKNX'+CCN"(View Classification) -
CKNX.R27517
UNITED STATES GYPSUM CO Subscrbr ID+and+CKNX'+CCN"(View Classification) -
CKNX.R1319
USG BORAL DRYWALL SFZ LLC Subscrbr ID+antl+CKNX'+CCN"(ViewClassification) -
CKNX.R38438
USG MEXICO S A DE C V Subscrbr ID+antl+CKNX'+CCN"(Visa Classification) -
CKNX.R16089
2A. Gypsum Boartl'-As an alternate to Rem 2- 3/4 in. thick gypsum wallboard. For 2 Hr
rating, 1-1/2 in. total thickness, installed in accordance with corner detail B. For3 Hr rating, 2-1/4
in. total thickness installed in accordance with corner debit C. Boards are to be applied vertically
without horizontal joints.
CGC INC -Type IP-X3 or ULTRACODE
UNITED STATES GYPSUM CO -Type IP-X3 or ULTRACODE
USG BORAL DRYWALL SFZ LLC - Type ULTRACODE
USG MEXICO S A DE C V -Type IP-X3 or ULTRACODE
2B. Gypsum Board' - (As an alternate to Items 2 and 2A)- Nominal 5/8 in. thick panels. One
of the layers of Gypsum Board (Item 2) used to obtain the minimum required thickness in Item 2
may be substituted with one layer and secured as described in Item 2.
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM -Type QuietRock ES
2C. Wall and Partition Facings and Accessories' - (As an alternate to Item 2 through 2B) -
Composite Gypsum Panel- Nominal 5/8 in. thick panels. One of the layers of Gypsum Board
(Item 2) used to obtain the minimum required thickness in Item 2 may be substituted with one
layer of composite gypsum panel and secured as described in Item 2.
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM - Type QuietRock OR
3. Steel Stud-1-5/8 in. wide with 1-5/16 and 1-7/16 in. legs having a 1/4- in. folded flange,
fabricated from No. 25 MSG galy steel. Length to be 112 in. less than the assembly height.
3A. As an alternate to Rem 3 Steel Framing Members' -galy. steel clips spaced 4 ft OC and
1-1/4 in. from top and boflem of column. A No. 28 MSG galy steel support angle with 1-1/4 in.
length shall be placed over clips and secured with screws attaching the wallboard. The angle cut
1 in. less than assembly height splices in angle to occur over clips. The clips for use with wide
flange columns only.
JOHN WAGNER ASSOCIATES INC, DBA GRABBER -Types CB, CB1Clips.
4. Comer Beads - No. 28 MSG galy steel, 1-1/4 in. legs to be attached to the wallboard with
No. 6 by 1 in. screws spaced 12 in. OC max.
5. Tie Wire - No. 18 SWG steel wire spaced 24 in. OC used with second layer of wallboard.
6. Screws - For attaching first layer of wallboard to steel studs, and third layer of wallboard to 2
in. by 2 in. steel angle (25 Gal to be No. 6 by 1 in. (or 1-1/4 in. for 3/4 in. thick wallboard) Phillips
head self -drilling, self -tapping double lead screws spaced 24 in. OC For attaching second layer
of wallboard to steel studs and fourth layer of wallboard! to 2 in. by 2 in. steel angle (25 Go) to be
No. 6 by 1-3/4 in. (or 2-1/4 in. for 3/4 in. thick wallboard) steel screws of the same type spaced
12 in. OC For attaching third layer of wallboard to steel studs to be No. 8 by 2-1/4 in. screws of
the same type spaced 12 in. OC
7. Finishing System - (Not Shown) - Joint compound applied over corner beads to a
thickness of 1/16 in.
' Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions
employing the UL or cUL Certification (such as Canada), respectively.
Design No. U905
December 20, 2018
Bearing Wall Rating-2 HR.
Nonbearing Wall Rating-2 HR
This design was evaluated using a load design method other than the Limit States Design
Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States
Design Method, such as Canada, a load restriction factor shall be used - See Guide
BXUV or BXUV7
' Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions
employing the UL or cUL Certification (such as Canada), respectively.
-1a� r nu CO<G'I�'>
I I� 7-S/B'MIN.
s__,__.
3
` 4 T i T HoriZf•M1fal Section
0 �:l
1. Concrete Blocks'- Various designs. Classification D-2 (2 hr).
See Concrete Blocks category for list of eligible manufacturers.
2. Mortar -Blocks laid in full bed of mortar, none. 18 in. thick, of not less than 2-1/4 and not
more than 3-1/2 palls of clean sharp sand to 1 pad Portland cement (proportioned by volume)
and not more than 50 percent hydrated lime (by cement volume). Vertical joints staggered.
3. Portland Cement Stucco or Gypsum Plaster -Add 1/2 hr to classification if used. Where
combustible members are framed in wall, plaster or stucco must the applied on the face opposite
framing to achieve a max. Classification of 1-1/2 hr. Attached to concrete blocks (Item 1).
4. Loose Masonry Fi 11- If all core spaces are filled with loose dry expanded slag, expanded
cla or shale Rota Kiln Process water re Ilan) vermiculite mason fill insulation or silicone
Y (Rotary ce masonry
treated partite loose fill insulation atltl 2 hr to classification.
5. Foamed Plastic' - (Optional -Not Shown)- 1-1/2 in. thick max, 4 ft wide sheathing attached
to concrete blocks (Item 1).
ATLAS ROOFING CORP- "EnergyShieltl Pro Wall Insulation", "EnergySh ield Pro 2 Wall
Insulation", EnergyShieltl CGF Pro and EnergyShieltl Ply Pro
CARLISLE COATINGS S WATERPROOFING INC - Type R2+ SHEATHE
FIRESTONE BUILDING PRODUCTS CO L L C- "EnvergeTM Cl Foil Exterior Wall Insulation"
and "EnvergeT" Cl Glass Exterior Wall Insulation"
HUNTER PANELS - Types Xci-Class A, Xci 286
RMAX OPERATING L L C-"TSX-8500", "TSX-8510", "Thermasheath-XP", "ECOMAXci ,
7hermasheath-3","Durasheath-3"
THE DOW CHEMICAL CO -Types Thermax Sheathing, Thermax Light Duty Insulation,
Thermax Heavy Duty Insulation, Thermax Metal Building Board, Thermax White Finish
Insulation, Thermax of Exterior Insulation, Thermax XARMOR of Exterior Insulation, Thermax IN
Insulation, Thermax Plus Liner Panel, Thermax Heavy Duty Plus (HDP) and TUFF-R^ ci
Insulation
5A. Building Units - As an alternate to Items 5, min. 1-in thick polyicocyanurete composite
foamed plastic insulation boards, nom. 48 by 48 or 96 in.
RMAX OPERATING L L C-"Thermasheath-SI", "ECOBASEci",'7hermaBase-CI",
"ECOMAXci FIR Ply"
Indicates such products shall bear the UL or cUL Certification Mark for jurlsdialons
employing the UL or cUL Certification (such as Canada), respectively.
BAS E4
BASE4
2901 CLINT MOORE ROAD, #114
BOCA RATON, FLORIDA 33496
888.901.8008 www.base4.conn
RICARDO J. MUNIZ-GULLIET, AIA
5453 NW 106TH DR
CORAL SPRINGS, FL 33076
Seal:
Er
1700161 rD;
OF
'
CHITEC4xx�.
xy If/IIIIIIIItllnitl
Owner:
It 1,
I
1 I
- a
THE WITNESS GROUP
600 ENTERPRISES DRIVE
LEWIS CENTER,OH
513.623.9430
HOME
SUITES BY HILTON
CARMEL,INDIANA
PROTOTYPE VERSION-V2.2 2016
REVISION: MAY 2016
DECOR PACKAGE: TRIBECA
ISSUE
NO.
DELTA
I ISSUE DATE
DESCRIPTION
1
AO
12019.03.04
ISSUEDFORPERMIT
CURRENT ISSUE
ISSUED FOR PERMIT
CURRENT ISSUE DATE
2019.03.04
DRAWN BY
NP
CHECKED BY
NIL
PROJECTNO.
B4-134-1705
SHEET NAME
FIRE RATED WALL
DETAILS
DRAWINGS NO.
A=034