HomeMy WebLinkAboutA-200 - INTERIOR FINISH LEGENDS & NOTESGENERAL NOTES:
BASE4 INTERIORS HAS PERFORMED THE WORK AND PRODUCED THE
INTERIOR CONTRACT DOCUMENTS IN ASSOCIATION WITH BASE4
ARCHITECTS & ENGINEERS.
REFER TO ARCHITECTURAL COVER SHEET FOR ADDITIONAL GENERAL
NOTES & REQUIREMENTS.
CONTRACTOR TO ENSURE CONCRETE FLOOR SLABS ARE LEVEL AND
SUITABLY PREPARED FOR INSTALLATION OF NEW FLOORING MATERIALS.
CONTRACTOR TO CONDUCT A MOISTURE PERMEATION TEST ON ALL
CONCRETE SLABS ON GRADE PRIOR TO THE INSTALLATION OF ANY AND
ALL FLOORING MATERIALS. TEST IS TO DETERMINE THE AMOUNT OF
MOISTURE PASSING UP THROUGH THE SLAB. CONTRACTOR TO NOTIFY
BASE4 OF ANY ISSUES PRIOR TO THE INSTALLATION OF FLOORING
MATERIAL. ALL MANUFACTURER'S RECOMMENDED INSTALLATION
REQUIREMENTS ARE TO BE MET.
ALL PREFINISHED MATERIALS SHALL BE PROTECTED FROM DAMAGE OR
REPAIRED/REPLACED AT CONTRACTOR'S EXPENSE.
ALL FIELD FINISH METAL WORK SHALL BE DONE IN ACCORDANCE WITH
THE PAINTING SPECIFICATIONS.
INTERIOR FINISH NOTES:
ALL CONDITIONS AND DIMENSIONS ON THE DRAWINGS AND AT THE
PROJECT SITE ARE TO BE FIELD VERIFIED PRIOR TO ORDERING
MATERIAL OR PROCEEDING WITH WORK.
SAMPLES OF ALL SPECIFIED FINISHES ARE TO BE SUBMITTED TO BASE4
FOR FINAL APPROVAL PRIOR TO ORDERING AND INSTALLING.
ALL SURFACES RECEIVING NEW FINISHES SHALL BE PROPERLY
PREPARED PER THE MATERIAL MANUFACTURER'S RECOMMENDATION.
NOTIFY BASE4 OF ANY DEFECT WHICH COULD AFFECT INSTALLATION OF
ANY FINISH MATERIAL.
ALL SEALANTS AND ADHESIVES USED IN CONSTRUCTION TO HAVE VOC
CONTENTS MEETING WITH OR LOWER THAN THE CONTENT LIMITS IN
THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE #1166.
CONTRACTOR IS TO COMPLY WITH FIRE DEPT. REGULATIONS & OSHA
REGULATIONS REGARDING USE AND DISPOSAL OF
FLAMMABLE/HAZARDOUS MATERIALS.
BASE4 CANNOT GUARANTEE WARRANTY OR BE HELD RESPONSIBLE
FOR A PRODUCTS OR MANUFACTURER'S FAILURE, OR ITS INABILITY TO
SATISFY ITS OBLIGATIONS.
ALL INTERIORS PRODUCTS INCLUDING BUILDING MATERIALS, FINISHES
AND FURNITURE PRODUCTS SPECIFIED FOR THE PROJECT ARE TO FALL
BELOW ACCEPTABLE CONTAMINANT LEVELS AS OUTLINED IN'MSDS'.
FLOORING INSTALLATION MUST COMPLY WITH MFR'S RECOMMENDED
INSTALLATION INSTRUCTIONS TO MAINTAIN DIRECTION OF PATTERN,
TEXTURE, NAP, AND PILE AT ALL SEAMED LOCATIONS.
ALL FLOORING MATERIALS SHALL BE INSTALLED ON A CLEAN AND
SMOOTH SUBSTRATE, AS PER MANUFACTURER
SPECIFICATIONS/RECOMMENDATIONS.
STANDARD SEAMLESS BROADLOOM & SHEET GOOD WIDTHS SHALL BE
USED AND SEAMS KEPT TO A PRACTICAL MINIMUM. INSTALLER SHALL
PROVIDE A SEAMING DIAGRAM IN THE FORM OF SHOP DRAWINGS TO
BASE4 FOR APPROVAL PRIOR TO ORDERING AND INSTALLING.
UNLESS OTHERWISE NOTED, FLOORING MATERIALS THAT TRANSITION
AT DOORWAYS SHALL BE SEAMED TO FALL HALF WAY UNDER CLOSED
DOOR AND ARE TO BE INVISIBLE WHEN DOOR IS CLOSED.
ALL BROADLOOM CARPET AND SHEET GOODS TO BE INSTALLED AS
DIRECT GLUE DOWN METHOD UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL ENSURE WITH THE IINSTALLER/DEALER MATCHING
DYE LOTS OF ALL FLOORING MATERIALS ARE IN THE SAME PATTERN
AND COLOR.
CARPET BASE SHALL HAVE EDGE BINDING TO MATCH CARPET COLOR.
CONTRACTOR TO PROVIDE BINDING SAMPLE TO BASE4 FOR APPROVAL
PRIOR TO FABRICATION. REFER TO PLANS FOR INSTALLATION
LOCATIONS.
MODULAR CARPET TO BE INSTALLED BY FULL SPREAD APPLICATION
WITH RELEASABLE ADHESIVE OR PER MANUFACTURER'S INSTALLATION
GUIDELINES.
PROVIDE AND INSTALL REDUCER STRIPS AND/OR APPROPRIATE
FLOORING TRANSITION ACCESSORIES WHERE CHANGE IN FLOORING
HEIGHTS OCCUR.
ALL CERAMIC/GRANITE/MARBLE/PORCELAIN TILES TO BE INSTALLED
PER MANUFACTURER'S RECOMMENDED INSTRUCTIONS FOR A THIN -SET
INSTALLATION. CONTRACTOR IS TO FIELD VERIFY CONDITION OF NEW
FLOOR PRIOR TO INSTALLATION FOR ANY PREP WORK REQUIRED. ALL
CUTTING OF TILES TO BE DONE WITH A WET SAW. JOINTS TO BE KEPT
TO A MINIMUM; 1/16- PREFERRED UNLESS NOTED OTHERWISE.
CONTRACTOR TO PROVIDE CLEVAGE MEMBRANE, SLIP SHEET AND/OR
CRACK SUPPRESSION SYSTEM AS REQUIRED FOR PROJECTS WITH TILE
EXCEEDING 12-X 12. OR WHEN FLOOR/SLAB MOVEMENT IS EXPECTED.
CONTRACTOR AND INSTALLERS TO REFER TO THE TCA (TILE COUNCIL
OF AMERICA) INSTALLATION HANDBOOK AND APPROPRIATE ANSI
SECTIONS FOR GUIDELINES AND REQUIREMENTS.
ALL STONE FLOORS AND COUNTERTOPS TO BE SEALED AS PER
MANUFACTURERS RECOMMENDATIONS, UNLESS NOTED OTHERWISE.
ALIGN CERAMIC/GRANITE/MARBLE/PORCELAIN TILE AND BASE GROUT
LINES.
INSTALLER TO APPLY GROUT SEALER (IF RECOMMENDED) AFTER
SUFFICIENT CURBING TIME HAS ELAPSED AND ALL MOISTURE HAS
EVAPORATED (GENERALLY 2-3 DAYS). REFER TO MANUFACTURER'S
INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION.
AT COMPLETION OF CONSTRUCTION, CONTRACTOR TO VACUUM ALL
CARPETS, CLEAN PRIOR TO PROVIDING (2) COATS OF SEALER WAX ON
ALL VINYL COMPOSITION TILE AND/OR SHEET FLOORING REQUIRING
SEALANT. PROVIDE A FINAL DAMP MOP FINISH ON ALL HARD FLOORING
SURFACES.
ALL BLOCKING BELOW COUNTERS TO BE PAINTED TO MATCH WALL
BEYOND.
ALL PAINT SHALL BE APPLIED AS RECOMMENDED BY THE PAINT
MANUFACTURERS FOR SPECIFIC PURPORSES.
ALL WALLCOVERING, INCLUDING VINYL AND TEXTILE WALLCOVERINGS,
SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFIED
MANUFACTURER'S INSTRUCTIONS TO ASSURE COLOR
UNIFORMITY/COLOR MATCH, AND TO MAINTAIN PRODUCT WARRANTIES.
REFLECTED CEILING PLAN LEGEND
BATHROOM NOTES:
REFER TO ENGINEERING DOCUMENTATION FOR ALL PLUMBING
SPECIFICATIONS, DRAINS, VENTS, ETC.
CONTRACTOR TO PROVIDE FIXTURE AND ACCESSORY CUT SHEETS TO
BASE4 INTERIORS FOR APPROVAL PRIOR TO ORDERING.
CONTRACTOR TO PROVIDE PHYSICAL TOILET PARTITION FINISH SAMPLES
TO BASE4 INTERIORS FOR APPROVAL PRIOR TO ORDERING.
CONTRACTOR TO INSTALL MOISTURE RESISTANT GWB OR BACKER BOARD
ATALL WET WALL LOCATIONS (I.E. WALLS AT SINKS, TOILETS, SHOWERS,
ETC.
CONTRACTOR TO PROVIDE BLOCKING IN WALLS BABY CHANGING STATIONS,
GRAB BAR LOCATIONS, AND SHOWER BENCH SEATS AS REQUIRED.
CONTRACTOR TO PROVIDE AND INSTALL FULL STEEL LADDER FRAMES AS
REQUIRED UNDER ALL STONE COUNTERS FOR SUPPORT. ADD ADDITIONAL
STEEL AND WOOD BLOCKING IN PARTITIONS BEYOND AS REQUIRED.
UNLESS CALLED FOR IN COUNTER DETAILS, NO VERTICAL LEGS ARE TO BE
USED.
COUNTERS TO BE SCRIBED TO ADJACENT WALLS ON ALL SIDES.
PAINTALL EXPOSED BLOCKING TO MATCH WALL BEYOND, UNLESS NOTED
OTHERWISE.
INSULATE ALL EXPOSED PIPES BELOW COUNTER PER ADA REQUIREMENTS,
USING TRUEBRO-LAV GUARD OR EQUAL; PROVIDE COLOR OPTIONS TO
BASE4 INTERIORS FOR APPROVAL PRIOR TO ORDERING.
CONTRACTOR TO PROVIDE PRODUCT DATA SUBMITTALS ON ALL TOILET
ACCESSORIES SPECIFIED. INSTALL TOILET AND BATH ACCESSORIES IN
ACCORDANCE WITH ADA REQUIREMENTS.
MILLWORK/ CASEWORK:
MILLWORK SUBCONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION
OF ALL PROJECT AREAS AND DELIVERY PATH
MEASUREMENTS/DIMENSIONS AND FIELD CONDITIONS PRIOR TO THE
START OF FABRICATION AND GENERALL COORDINATION WITH OTHER
TRADES AS REQUIRED.
CONTRACTOR TO ENSURE THAT THE FIELD CONDITIONS IN THE
CONSTRUCTION AREA ARE SUITABLE FOR RECEIVING/INSTALL OF ANY
AND ALL MILLWORK/CASEWORK. THE APPROXIMATE RANGES ARE
RECOMMENDED: OPTIMUM MOISTURE CONTENT OF WOOD: 5-10%,
INDOOR RELATIVE HUMIDITY REQUIRED TO HOLD OPTIMUM MOISTURE
CONTENT: 2555 h (TEMPERATURE AND HUMIDITY AFFECTS WOOD
PRODUCTS). GC TO REFER TO MOST RECENT AW I TEMPERATURE AND
HUMIDITY CHART TO VERIFY CONDITIONS ARE SUITABLE.
DELIVERY OF ALL MILLWORK TO THE PROJECT AREA (ELEVATOR AND/OR
STAIRS) IS TO BE COORDINATED WITH THE GENERAL CONTRACTOR. ALL
MILLWORK IS TO BE CONSTRUCTED IN SECTIONS AS REQUIRED IN
ORDER TO BE DELIVERED AND INSTALLED AS EFFICIENTLY AS POSSIBLE
AT THE SITE.
FULL DETAILED SHOP DRAWINGS ARE TO BE SUBMITTED TO BASE4
INTERIORS AND SHOULD INCLUDE DIMENSIONED PLANS/ELEVATIONS,
ATTACHMENT DEVICES, BLOCKING & SHIMMING REQUIRED
ALL CASEWORK AND FINISHINGS ARE TO CONFORM WITH THE
"ARCHITECTURAL WOODWORK QUALITY STANDARDS- OF THE
ARCHITECTURAL WOODWORK INSTITUE (AWI), LATEST EDITION.
ALL PLASTIC LAMINATES OR FINISH MATERIALS WITH A GRAIN/PATTERN
AND/OR TEXTURE IS TO BE INSTALLED SO THATTHE GRAIN/PATTERN
AND/OR TEXTURE IS CONTINUOUS ACROSS ALL SURFACES FOR A
UNIFORM INSTALLATION. REFER TO DRAWINGS FOR SPECIFIC
DIRECTIONS.
THE CONTRACTOR SHALL COORDINATE THE SCOPE OF MILLWORK WITH
ALL PROJECT ELECTRICAL, COMMUNICATIONS, PLUMBING, LIGHTING
F00(TURE AND DEVICE LOCATIONS. THE CONTRACTOR SHALL
COORDINATE AND BE RESPONSIBLE FOR CUTOUTS AND TEMPLATES
SUPPLIED BY OTHER TRADES.
ELECTRICAL WORK SPECIFIED IN CONJUNCTION WITH MILLWORK IS TO
BE UL APPROVED AND PROVIDED BY ELECTRICAL CONTRACTOR.
MILLWORK CONTRACTOR TO COORDINATE INSTALLATION.
CONTRACTOR IS RESPONSIBLE FOR PROVING WOOD BLOCKING AND/OR
SUPPORT METAL IN PARTITIONS BEYOND MILLWORK AS REQUIRED FOR
SECURE ANCHORING OF MILLWORK. ALL VISIBLE BLOCKING TO BE
PAINTED TO MATCH SURROUNDING WALLS.
ALL COUNTERTOP AND BACKSPLASH SEAMS ARE TO ALIGN WITH ONE
ANOTHER. ALL SEAMS ARE TO BE EQUALLY SPACED ALONG
COUNTERTOP UNLESS OTHERWISE NOTED ON DRAWINGS. PROVIDE A
MITERED COUNTERTOP SEAM AT ALL 90 DEGREE COUNTERTOP
INTERSECTIONS UNLESS OTHERWISE NOTED ON DRAWINGS.
ALL COUNTERTOP TO WALL OR BACKSPLASH JOINTS TO BE
CONTINUOUSLY SEALED WITH A CLEAR SILICONE SEALANT.
WHEREVER COUNTERS ARE INSTALLED WITHOUT BACKSPLASH,
CONTRACTOR IS TO PROVIDE CAULK OF AN APPROPRIATE MATCHING
COLOR AS REQUIRED AT THE INTERSECTION OF COUNTER WITH WALL.
PROVIDE COLOR SAMPLE TO BASE4 FOR APPROVAL PRIOR TO
INSTALLATION.
CONTRACTOR IS TO PROVIDE BLOCKING, FRAMING AND/OR P.LAM
VERTICAL SUPPORT LEGS FOR ALL COUNTERS IN ORDER TO
ACCOMMODATE 100 LBS PER LINEAL FOOT. SUPPORT SPACING NOT TO
EXCEED 48. ON CENTER, TYP.
ALL MILLWORK TO BE SCRIBED TO ADJACENT WALLS, CEILINGS AND/OR
FLOORS. PROVIDE FILLER STRIPS/PIECES AS REQUIRED FOR A UNIFORM,
TIGHT INSTALLATION.
ALL WALL OR BASE CABINETS WITH INTERNAL SHELVING HAVING A SPAN
GREATER THAN 36-W IS TO BE PROVIDED WITH ADDITIONAL CENTER
SUPPORTS AS REQUIRED.
FIELD TOUCHUP SHALL BE COMPLETED UPON INSTALLATION OF
MILLWORK. THIS SHALL INCLUDE THE FILLING AND TOUCHUP OF
EXPOSED JOB MADE NAIL OR SCREW HOLES, REFINISHING OF RAW
SURFACES RESULTING FROM JOB FITTING AND REPAIR OF JOB
INFLICTED SCRATCHED AND MARKS, ALONGW ITH FINAL CLEANUP OF
FINISHED SURFACES, HARDWARE AND INSTALLATION AREA.
THE INSTALLER IS TO PROVIDE A GENERAL CLEANUP IN AND AROUND
ALL INSTALLATION WORK INCLUDING REMOVING ALL TOOLS, SCRAP
MATERIAL, ETC.
FLUORESCENT LIGHT
EXIT LIGHT
RETURNIEXHAUST
FLUORESCENT LIGHT
ACCESS PAN0`
AP
GRILLE
®
(1'-0"x 1'-0"UNO) O)
(T-0"x2'-0")
SMOKE DETECTORS
®
LINEAR DIFFUSER
�
e
DOWNLIGHT
0 O
SPEAKERS
O
SUPPLY AIR DIFFUSER
PENDANT LIGHT
Q
FIRE ALARM/HORN/STROBE V1
SPRINKLER HEADS
WALL WASH LIGHT
0i
WALL MOUNT
SPR.
STRIP LIGHTS — — — CEILING LIGHT O SPRINKLER HEADS
(RACK& HEADBOARDS) CEILING MOUNT
CEILING FAN
WALL MOUNT LIGHT '0
® ACCESS PANEL
COMBINATION OF SMOKE (1'-0"xi'-0" UNO)
AND CO DETECTOR
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel ((��
`�vmlUtlenrJnwJ�L
x
DATE: 07/22/19
AP
EILING DIMENSION LEGEND
CENTER FIXTURE IN SPACE
-CENTER THE FIXTURE IN SPACE
IDENTIFIED BY DIAGONAL LINE.
ALIGN FIXTURES
—�—� - ALIGN FIXTURES ALONG
CENTERLINE SHOWN
CENTER OVER
S= - CENTER THE FIXTURE IN SPACE
IDENTIFIED BY DIAGONAL LINE.
OUESTROOM
FURNISHINGS LEGEND:
GR-100
OTTOMAN
GR-101
SLEEPER SOFA
GR-102
DINING CHAIR
GR-103
LOUNGE CHAIR
OR-104
TASK CHAIR
GR-200
SIDE TABLE LAMP
GR-201
TASKLAMP
GR-202
HEADBOARD WALL SCONCE
GR-203
VANITY LIGHT
GR-204
FLOOR LAMP
GR-205
END WALL SCONCE
GR-206
NIGHTSTAND TABLE LAMP
GR-207
END WALL SCONCE
GR-208
SOFA WALL SCONCE
GR-300
QUEEN HEADBOARD
GR-301
KING HEADBOARD
GR-302
VANITY
OR-303
ACCESSIBLE VANITY
GR-304-16
WORKING WALL
GR-317
NIGHTSTAND
GR-318
SIDE TABLE
GR-319
DINING TABLE
GR-400-03
ROLLER SHADE
GR-404
ROOM DIVIDER
GR-405-06
CLOSET DRAPERY
GR-500
ARTWORKAT SLEEPER SOFA
GR-501
ARTWORK AT DINING TABLE
GR-502
ARTWORK AT END WALL
GR-503
VANITY MIRROR
GR-504
WALL MIRROR
GR-600
QUEEN BOXSPRING COVER
GR-601
KING BOXSPRING COVER
GR-602
QUEEN BED BASE
GR-603
KING BED BASE
GR-604
QUEEN COVERLET
GR-605
KING COVERLET
901
REFRIGERATOR
902
DISHWASHER
903
TELEVISION
904
CLOCK/RADIO
905
TELEPHONE
906
QUEEN MATTRESS &BOXSPRING
907
KING MATTRESS & BOXSPRING
908
SHOWER CURTAIN ROD
909
SHOWER CURTAIN
m FINISH LEGEND:
PT
PAINT
PL
PLASTIC LAMINATE
ST
STONE
SS
SOLD SURFACE
SF
SPECIAL FINISH
CO
CONCRETE
CIE
CARPET
CT
TILE
G
GLASS
QT
QUARRYTILE
VB
VINYL BASE
VCT
VINYL COMPOSITION TILE
VF
VINYL FLOORING
WC
WALL COVERING
NOTE:
REFER TO FF&E PACKAGE FOR FURNITURE AND FINISH
SPECIFICATIONS
XXX
FURNITURE LEGEND
XXX
FURNITURE LEGEND
PA-100
BANQUETTE
300
SHELVING
Pi 01-03
PILLOW
301
OFFICE FURNITURE
PA-104-06
LOUNGE CHAIR
302
WORKSTATION
PA-107
PILLOW
303
SAFE
PA-108
COUNTER STOOL
304
LOCKER
Pi 09
LOUNGE CHAIR
305
STACKABLE CHAIR
PA-110-12
DINING CHAIR
400
FIRE PIT WITH FITTED SCREEN
PA-113
OTTOMAN
401
COMMERCIAL WASHER
PA-114-16
BARSTOOL
402
COMMERCIAL DRYER
Pi 17
TASK CHAIR
403
WORK CENTER
PA-118
BENCH
404
WIRE SHELVING
PA-200
PENDANT
405
BREAKROOM SINK
PA-201
SMALL PENDANT
406
COIN OPERATED WASHER
PA-202
TABLE LAMP
407
COIN OPERATED DRYER
PA-203
CEILING LIGHT
408
DECORATIVE TRASH CAN
PA-204
WALL SCONCE
409
DISHWASHER
PA-205
FLOOR LAMP
410
MOBILE TABLE
PA-300
BREAKFAST SERVING COUNTER
411
REACH -IN COOLER
PA-301
BUSSING STATION
412
REACH -IN FREEZER
PA-302
MEDIA WALL & COFFEE BAR
413
WORK STATION
PA-303
DISH RECOVERY
PA-304
HOME 2 MARKET
414
MOBILE SHELVING
PA-305
FRONT DESK
415
COFFEE MACHINE
416
3-COMPARTMENT SINK
PA-306
BUSINESS CENTER
418
HANDSINK
PA-307
WINDOWPERCH
PA-308
PERCH
418
LF
PA-309-10
SERVING COUNTER MEETING ROOM
420
PRE-RIRACK/NSE
PRE -RINSE WITH FAUCET
PA400-02
ROLLER SHADE
420
WATER FILTER
PA403
DRAPERY PANELS
421
WALL MOUNTED SHELVING
PA404
ROMAN SHADE
422
SMART FRIDGE
PA405
ROLLER SHADE
423
COLD WELL
PA-500-07
ARTWORK
424
COMMERCIAL MICROWAVE
PA-50B
MIRROR
425
TOASTER CONVEYOR OVEN
PA-600
TOWEL HAMPER
426
JUICE DISPENSER
PA-602
UTILITYCART
427
REFRIGERATOR
OF-603-05
PLANTER
428
VENTLESS EXHAUST SYSTEM
OF-700
BENCH
429
MERCHANDISER REFRIGERATOR
OF-701
LOUNGE CHAIR
430
MERCHANDISER FREEZER
OF702
BENCH
431
WALL MOUNTED TELEVISION
OF-703
OTTOMAN
432
ICE DISPENSER
OF-704
CUBE TABLE
433
KETTLE RETHERMALIZER
OF-705
C-TABLE
434
WAFFLE MAKER
OF-706
SIDE TABLE
800
TOWEL HAMPER
OF-707
SIDE TABLE
801
WATER & CUP DISPENSER
OF-708
4-TOP TABLE
802
GYM WIPES DISPENSER
OF-712
DINING CHAIR
803
TREADMILL
OF-722
ENTRY BENCH
804
FITNESS TRAINER ELLIPTICAL
PA-800-01
ROUNDTABLE
805
RECUMBENT CYCLE
PA-802
RECTANGULAR TABLE
806
FREE WEIGHTS &RACK
PA-803
HALF ROUND TABLE
807
WEIGHT BENCH
PA-804
BREAKFAST TABLE
808
STRENGTH SYSTEM
PA-805
LOG SIDE TABLE
809
MEDICINE BALLS & RACK
PA-806-07
SIDE TABLE
810
EXERCISE BALL
PA-808
CONSOLE TABLE
811
EXERCISE MAT
PA-809
ADIRONDACK CHAIR
812
RULES SIGN
PA-810
TOWEL AND FOLDING STATION
813
WALL MOUNTED TELEVISION
PA-811
SIDE TABLE
814
EMERGENCY TELEPHONE
BOH-812
BREAKROOM TABLE
816
TOWELHOOK
OF-722
BENCH
817
WALL MOUNTED MIRROR
OF-604
PLANTERS
819
WALL MOUNTED CLOCK
OF-605
OF-603
PLANTERS
BASE4.
BASE4
2901 CLINT MOORE ROAD, #114
BOCA RATON, FLORIDA 33496
888.901.8008 www.base-4.Dom
RICARDO J. MUNIZ-GULLIET, All
5453 NW 106TH DR
CORAL SPRINGS, FL 33076
Seal:
j.t..... .,
```."o
``eO;'PEGISTE/kO
17oo161
OF
' 'u/CHITt�G4``�.
owner:
1 I
THE WITNESS GROUP
600 ENTERPRISES DRIVE
LEWIS CENTER,OH
513.623.9430
HOME
SUITES BY HILTON
CARMEL,INDIANA
PROTOTYPE VERSION-V2.2 2016
REVISION: MAY 2016
DECOR PACKAGE: TRIBECA
ISSUE
NO.
DELTA
ISSUE DATE
DESCRIPTION
1
JAD
12DI9.D3.D4
ISSUED FOR PERMIT
CURRENT ISSUE
ISSUED FOR PERMIT
CURRENT ISSUE DATE
2019.03.04
DRAWN BY
NP
CHECKED BY
NIL
PROJECTNO,
B4-134-1705
SHEET NAME
INTERIOR FINISH
LEGENDS & NOTES
DRAWINGS NO.
A=200