HomeMy WebLinkAboutA-200 - INTERIOR FINISH LEGENDS & NOTESGENERAL NOTES: BASE4 INTERIORS HAS PERFORMED THE WORK AND PRODUCED THE INTERIOR CONTRACT DOCUMENTS IN ASSOCIATION WITH BASE4 ARCHITECTS & ENGINEERS. REFER TO ARCHITECTURAL COVER SHEET FOR ADDITIONAL GENERAL NOTES & REQUIREMENTS. CONTRACTOR TO ENSURE CONCRETE FLOOR SLABS ARE LEVEL AND SUITABLY PREPARED FOR INSTALLATION OF NEW FLOORING MATERIALS. CONTRACTOR TO CONDUCT A MOISTURE PERMEATION TEST ON ALL CONCRETE SLABS ON GRADE PRIOR TO THE INSTALLATION OF ANY AND ALL FLOORING MATERIALS. TEST IS TO DETERMINE THE AMOUNT OF MOISTURE PASSING UP THROUGH THE SLAB. CONTRACTOR TO NOTIFY BASE4 OF ANY ISSUES PRIOR TO THE INSTALLATION OF FLOORING MATERIAL. ALL MANUFACTURER'S RECOMMENDED INSTALLATION REQUIREMENTS ARE TO BE MET. ALL PREFINISHED MATERIALS SHALL BE PROTECTED FROM DAMAGE OR REPAIRED/REPLACED AT CONTRACTOR'S EXPENSE. ALL FIELD FINISH METAL WORK SHALL BE DONE IN ACCORDANCE WITH THE PAINTING SPECIFICATIONS. INTERIOR FINISH NOTES: ALL CONDITIONS AND DIMENSIONS ON THE DRAWINGS AND AT THE PROJECT SITE ARE TO BE FIELD VERIFIED PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH WORK. SAMPLES OF ALL SPECIFIED FINISHES ARE TO BE SUBMITTED TO BASE4 FOR FINAL APPROVAL PRIOR TO ORDERING AND INSTALLING. ALL SURFACES RECEIVING NEW FINISHES SHALL BE PROPERLY PREPARED PER THE MATERIAL MANUFACTURER'S RECOMMENDATION. NOTIFY BASE4 OF ANY DEFECT WHICH COULD AFFECT INSTALLATION OF ANY FINISH MATERIAL. ALL SEALANTS AND ADHESIVES USED IN CONSTRUCTION TO HAVE VOC CONTENTS MEETING WITH OR LOWER THAN THE CONTENT LIMITS IN THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE #1166. CONTRACTOR IS TO COMPLY WITH FIRE DEPT. REGULATIONS & OSHA REGULATIONS REGARDING USE AND DISPOSAL OF FLAMMABLE/HAZARDOUS MATERIALS. BASE4 CANNOT GUARANTEE WARRANTY OR BE HELD RESPONSIBLE FOR A PRODUCTS OR MANUFACTURER'S FAILURE, OR ITS INABILITY TO SATISFY ITS OBLIGATIONS. ALL INTERIORS PRODUCTS INCLUDING BUILDING MATERIALS, FINISHES AND FURNITURE PRODUCTS SPECIFIED FOR THE PROJECT ARE TO FALL BELOW ACCEPTABLE CONTAMINANT LEVELS AS OUTLINED IN'MSDS'. FLOORING INSTALLATION MUST COMPLY WITH MFR'S RECOMMENDED INSTALLATION INSTRUCTIONS TO MAINTAIN DIRECTION OF PATTERN, TEXTURE, NAP, AND PILE AT ALL SEAMED LOCATIONS. ALL FLOORING MATERIALS SHALL BE INSTALLED ON A CLEAN AND SMOOTH SUBSTRATE, AS PER MANUFACTURER SPECIFICATIONS/RECOMMENDATIONS. STANDARD SEAMLESS BROADLOOM & SHEET GOOD WIDTHS SHALL BE USED AND SEAMS KEPT TO A PRACTICAL MINIMUM. INSTALLER SHALL PROVIDE A SEAMING DIAGRAM IN THE FORM OF SHOP DRAWINGS TO BASE4 FOR APPROVAL PRIOR TO ORDERING AND INSTALLING. UNLESS OTHERWISE NOTED, FLOORING MATERIALS THAT TRANSITION AT DOORWAYS SHALL BE SEAMED TO FALL HALF WAY UNDER CLOSED DOOR AND ARE TO BE INVISIBLE WHEN DOOR IS CLOSED. ALL BROADLOOM CARPET AND SHEET GOODS TO BE INSTALLED AS DIRECT GLUE DOWN METHOD UNLESS OTHERWISE NOTED. CONTRACTOR SHALL ENSURE WITH THE IINSTALLER/DEALER MATCHING DYE LOTS OF ALL FLOORING MATERIALS ARE IN THE SAME PATTERN AND COLOR. CARPET BASE SHALL HAVE EDGE BINDING TO MATCH CARPET COLOR. CONTRACTOR TO PROVIDE BINDING SAMPLE TO BASE4 FOR APPROVAL PRIOR TO FABRICATION. REFER TO PLANS FOR INSTALLATION LOCATIONS. MODULAR CARPET TO BE INSTALLED BY FULL SPREAD APPLICATION WITH RELEASABLE ADHESIVE OR PER MANUFACTURER'S INSTALLATION GUIDELINES. PROVIDE AND INSTALL REDUCER STRIPS AND/OR APPROPRIATE FLOORING TRANSITION ACCESSORIES WHERE CHANGE IN FLOORING HEIGHTS OCCUR. ALL CERAMIC/GRANITE/MARBLE/PORCELAIN TILES TO BE INSTALLED PER MANUFACTURER'S RECOMMENDED INSTRUCTIONS FOR A THIN -SET INSTALLATION. CONTRACTOR IS TO FIELD VERIFY CONDITION OF NEW FLOOR PRIOR TO INSTALLATION FOR ANY PREP WORK REQUIRED. ALL CUTTING OF TILES TO BE DONE WITH A WET SAW. JOINTS TO BE KEPT TO A MINIMUM; 1/16- PREFERRED UNLESS NOTED OTHERWISE. CONTRACTOR TO PROVIDE CLEVAGE MEMBRANE, SLIP SHEET AND/OR CRACK SUPPRESSION SYSTEM AS REQUIRED FOR PROJECTS WITH TILE EXCEEDING 12-X 12. OR WHEN FLOOR/SLAB MOVEMENT IS EXPECTED. CONTRACTOR AND INSTALLERS TO REFER TO THE TCA (TILE COUNCIL OF AMERICA) INSTALLATION HANDBOOK AND APPROPRIATE ANSI SECTIONS FOR GUIDELINES AND REQUIREMENTS. ALL STONE FLOORS AND COUNTERTOPS TO BE SEALED AS PER MANUFACTURERS RECOMMENDATIONS, UNLESS NOTED OTHERWISE. ALIGN CERAMIC/GRANITE/MARBLE/PORCELAIN TILE AND BASE GROUT LINES. INSTALLER TO APPLY GROUT SEALER (IF RECOMMENDED) AFTER SUFFICIENT CURBING TIME HAS ELAPSED AND ALL MOISTURE HAS EVAPORATED (GENERALLY 2-3 DAYS). REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION. AT COMPLETION OF CONSTRUCTION, CONTRACTOR TO VACUUM ALL CARPETS, CLEAN PRIOR TO PROVIDING (2) COATS OF SEALER WAX ON ALL VINYL COMPOSITION TILE AND/OR SHEET FLOORING REQUIRING SEALANT. PROVIDE A FINAL DAMP MOP FINISH ON ALL HARD FLOORING SURFACES. ALL BLOCKING BELOW COUNTERS TO BE PAINTED TO MATCH WALL BEYOND. ALL PAINT SHALL BE APPLIED AS RECOMMENDED BY THE PAINT MANUFACTURERS FOR SPECIFIC PURPORSES. ALL WALLCOVERING, INCLUDING VINYL AND TEXTILE WALLCOVERINGS, SHALL BE INSTALLED IN ACCORDANCE WITH THE SPECIFIED MANUFACTURER'S INSTRUCTIONS TO ASSURE COLOR UNIFORMITY/COLOR MATCH, AND TO MAINTAIN PRODUCT WARRANTIES. REFLECTED CEILING PLAN LEGEND BATHROOM NOTES: REFER TO ENGINEERING DOCUMENTATION FOR ALL PLUMBING SPECIFICATIONS, DRAINS, VENTS, ETC. CONTRACTOR TO PROVIDE FIXTURE AND ACCESSORY CUT SHEETS TO BASE4 INTERIORS FOR APPROVAL PRIOR TO ORDERING. CONTRACTOR TO PROVIDE PHYSICAL TOILET PARTITION FINISH SAMPLES TO BASE4 INTERIORS FOR APPROVAL PRIOR TO ORDERING. CONTRACTOR TO INSTALL MOISTURE RESISTANT GWB OR BACKER BOARD ATALL WET WALL LOCATIONS (I.E. WALLS AT SINKS, TOILETS, SHOWERS, ETC. CONTRACTOR TO PROVIDE BLOCKING IN WALLS BABY CHANGING STATIONS, GRAB BAR LOCATIONS, AND SHOWER BENCH SEATS AS REQUIRED. CONTRACTOR TO PROVIDE AND INSTALL FULL STEEL LADDER FRAMES AS REQUIRED UNDER ALL STONE COUNTERS FOR SUPPORT. ADD ADDITIONAL STEEL AND WOOD BLOCKING IN PARTITIONS BEYOND AS REQUIRED. UNLESS CALLED FOR IN COUNTER DETAILS, NO VERTICAL LEGS ARE TO BE USED. COUNTERS TO BE SCRIBED TO ADJACENT WALLS ON ALL SIDES. PAINTALL EXPOSED BLOCKING TO MATCH WALL BEYOND, UNLESS NOTED OTHERWISE. INSULATE ALL EXPOSED PIPES BELOW COUNTER PER ADA REQUIREMENTS, USING TRUEBRO-LAV GUARD OR EQUAL; PROVIDE COLOR OPTIONS TO BASE4 INTERIORS FOR APPROVAL PRIOR TO ORDERING. CONTRACTOR TO PROVIDE PRODUCT DATA SUBMITTALS ON ALL TOILET ACCESSORIES SPECIFIED. INSTALL TOILET AND BATH ACCESSORIES IN ACCORDANCE WITH ADA REQUIREMENTS. MILLWORK/ CASEWORK: MILLWORK SUBCONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL PROJECT AREAS AND DELIVERY PATH MEASUREMENTS/DIMENSIONS AND FIELD CONDITIONS PRIOR TO THE START OF FABRICATION AND GENERALL COORDINATION WITH OTHER TRADES AS REQUIRED. CONTRACTOR TO ENSURE THAT THE FIELD CONDITIONS IN THE CONSTRUCTION AREA ARE SUITABLE FOR RECEIVING/INSTALL OF ANY AND ALL MILLWORK/CASEWORK. THE APPROXIMATE RANGES ARE RECOMMENDED: OPTIMUM MOISTURE CONTENT OF WOOD: 5-10%, INDOOR RELATIVE HUMIDITY REQUIRED TO HOLD OPTIMUM MOISTURE CONTENT: 2555 h (TEMPERATURE AND HUMIDITY AFFECTS WOOD PRODUCTS). GC TO REFER TO MOST RECENT AW I TEMPERATURE AND HUMIDITY CHART TO VERIFY CONDITIONS ARE SUITABLE. DELIVERY OF ALL MILLWORK TO THE PROJECT AREA (ELEVATOR AND/OR STAIRS) IS TO BE COORDINATED WITH THE GENERAL CONTRACTOR. ALL MILLWORK IS TO BE CONSTRUCTED IN SECTIONS AS REQUIRED IN ORDER TO BE DELIVERED AND INSTALLED AS EFFICIENTLY AS POSSIBLE AT THE SITE. FULL DETAILED SHOP DRAWINGS ARE TO BE SUBMITTED TO BASE4 INTERIORS AND SHOULD INCLUDE DIMENSIONED PLANS/ELEVATIONS, ATTACHMENT DEVICES, BLOCKING & SHIMMING REQUIRED ALL CASEWORK AND FINISHINGS ARE TO CONFORM WITH THE "ARCHITECTURAL WOODWORK QUALITY STANDARDS- OF THE ARCHITECTURAL WOODWORK INSTITUE (AWI), LATEST EDITION. ALL PLASTIC LAMINATES OR FINISH MATERIALS WITH A GRAIN/PATTERN AND/OR TEXTURE IS TO BE INSTALLED SO THATTHE GRAIN/PATTERN AND/OR TEXTURE IS CONTINUOUS ACROSS ALL SURFACES FOR A UNIFORM INSTALLATION. REFER TO DRAWINGS FOR SPECIFIC DIRECTIONS. THE CONTRACTOR SHALL COORDINATE THE SCOPE OF MILLWORK WITH ALL PROJECT ELECTRICAL, COMMUNICATIONS, PLUMBING, LIGHTING F00(TURE AND DEVICE LOCATIONS. THE CONTRACTOR SHALL COORDINATE AND BE RESPONSIBLE FOR CUTOUTS AND TEMPLATES SUPPLIED BY OTHER TRADES. ELECTRICAL WORK SPECIFIED IN CONJUNCTION WITH MILLWORK IS TO BE UL APPROVED AND PROVIDED BY ELECTRICAL CONTRACTOR. MILLWORK CONTRACTOR TO COORDINATE INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR PROVING WOOD BLOCKING AND/OR SUPPORT METAL IN PARTITIONS BEYOND MILLWORK AS REQUIRED FOR SECURE ANCHORING OF MILLWORK. ALL VISIBLE BLOCKING TO BE PAINTED TO MATCH SURROUNDING WALLS. ALL COUNTERTOP AND BACKSPLASH SEAMS ARE TO ALIGN WITH ONE ANOTHER. ALL SEAMS ARE TO BE EQUALLY SPACED ALONG COUNTERTOP UNLESS OTHERWISE NOTED ON DRAWINGS. PROVIDE A MITERED COUNTERTOP SEAM AT ALL 90 DEGREE COUNTERTOP INTERSECTIONS UNLESS OTHERWISE NOTED ON DRAWINGS. ALL COUNTERTOP TO WALL OR BACKSPLASH JOINTS TO BE CONTINUOUSLY SEALED WITH A CLEAR SILICONE SEALANT. WHEREVER COUNTERS ARE INSTALLED WITHOUT BACKSPLASH, CONTRACTOR IS TO PROVIDE CAULK OF AN APPROPRIATE MATCHING COLOR AS REQUIRED AT THE INTERSECTION OF COUNTER WITH WALL. PROVIDE COLOR SAMPLE TO BASE4 FOR APPROVAL PRIOR TO INSTALLATION. CONTRACTOR IS TO PROVIDE BLOCKING, FRAMING AND/OR P.LAM VERTICAL SUPPORT LEGS FOR ALL COUNTERS IN ORDER TO ACCOMMODATE 100 LBS PER LINEAL FOOT. SUPPORT SPACING NOT TO EXCEED 48. ON CENTER, TYP. ALL MILLWORK TO BE SCRIBED TO ADJACENT WALLS, CEILINGS AND/OR FLOORS. PROVIDE FILLER STRIPS/PIECES AS REQUIRED FOR A UNIFORM, TIGHT INSTALLATION. ALL WALL OR BASE CABINETS WITH INTERNAL SHELVING HAVING A SPAN GREATER THAN 36-W IS TO BE PROVIDED WITH ADDITIONAL CENTER SUPPORTS AS REQUIRED. FIELD TOUCHUP SHALL BE COMPLETED UPON INSTALLATION OF MILLWORK. THIS SHALL INCLUDE THE FILLING AND TOUCHUP OF EXPOSED JOB MADE NAIL OR SCREW HOLES, REFINISHING OF RAW SURFACES RESULTING FROM JOB FITTING AND REPAIR OF JOB INFLICTED SCRATCHED AND MARKS, ALONGW ITH FINAL CLEANUP OF FINISHED SURFACES, HARDWARE AND INSTALLATION AREA. THE INSTALLER IS TO PROVIDE A GENERAL CLEANUP IN AND AROUND ALL INSTALLATION WORK INCLUDING REMOVING ALL TOOLS, SCRAP MATERIAL, ETC. FLUORESCENT LIGHT EXIT LIGHT RETURNIEXHAUST FLUORESCENT LIGHT ACCESS PAN0` AP GRILLE ® (1'-0"x 1'-0"UNO) O) (T-0"x2'-0") SMOKE DETECTORS ® LINEAR DIFFUSER � e DOWNLIGHT 0 O SPEAKERS O SUPPLY AIR DIFFUSER PENDANT LIGHT Q FIRE ALARM/HORN/STROBE V1 SPRINKLER HEADS WALL WASH LIGHT 0i WALL MOUNT SPR. STRIP LIGHTS — — — CEILING LIGHT O SPRINKLER HEADS (RACK& HEADBOARDS) CEILING MOUNT CEILING FAN WALL MOUNT LIGHT '0 ® ACCESS PANEL COMBINATION OF SMOKE (1'-0"xi'-0" UNO) AND CO DETECTOR RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� `�vmlUtlenrJnwJ�L x DATE: 07/22/19 AP EILING DIMENSION LEGEND CENTER FIXTURE IN SPACE -CENTER THE FIXTURE IN SPACE IDENTIFIED BY DIAGONAL LINE. ALIGN FIXTURES —�—� - ALIGN FIXTURES ALONG CENTERLINE SHOWN CENTER OVER S= - CENTER THE FIXTURE IN SPACE IDENTIFIED BY DIAGONAL LINE. OUESTROOM FURNISHINGS LEGEND: GR-100 OTTOMAN GR-101 SLEEPER SOFA GR-102 DINING CHAIR GR-103 LOUNGE CHAIR OR-104 TASK CHAIR GR-200 SIDE TABLE LAMP GR-201 TASKLAMP GR-202 HEADBOARD WALL SCONCE GR-203 VANITY LIGHT GR-204 FLOOR LAMP GR-205 END WALL SCONCE GR-206 NIGHTSTAND TABLE LAMP GR-207 END WALL SCONCE GR-208 SOFA WALL SCONCE GR-300 QUEEN HEADBOARD GR-301 KING HEADBOARD GR-302 VANITY OR-303 ACCESSIBLE VANITY GR-304-16 WORKING WALL GR-317 NIGHTSTAND GR-318 SIDE TABLE GR-319 DINING TABLE GR-400-03 ROLLER SHADE GR-404 ROOM DIVIDER GR-405-06 CLOSET DRAPERY GR-500 ARTWORKAT SLEEPER SOFA GR-501 ARTWORK AT DINING TABLE GR-502 ARTWORK AT END WALL GR-503 VANITY MIRROR GR-504 WALL MIRROR GR-600 QUEEN BOXSPRING COVER GR-601 KING BOXSPRING COVER GR-602 QUEEN BED BASE GR-603 KING BED BASE GR-604 QUEEN COVERLET GR-605 KING COVERLET 901 REFRIGERATOR 902 DISHWASHER 903 TELEVISION 904 CLOCK/RADIO 905 TELEPHONE 906 QUEEN MATTRESS &BOXSPRING 907 KING MATTRESS & BOXSPRING 908 SHOWER CURTAIN ROD 909 SHOWER CURTAIN m FINISH LEGEND: PT PAINT PL PLASTIC LAMINATE ST STONE SS SOLD SURFACE SF SPECIAL FINISH CO CONCRETE CIE CARPET CT TILE G GLASS QT QUARRYTILE VB VINYL BASE VCT VINYL COMPOSITION TILE VF VINYL FLOORING WC WALL COVERING NOTE: REFER TO FF&E PACKAGE FOR FURNITURE AND FINISH SPECIFICATIONS XXX FURNITURE LEGEND XXX FURNITURE LEGEND PA-100 BANQUETTE 300 SHELVING Pi 01-03 PILLOW 301 OFFICE FURNITURE PA-104-06 LOUNGE CHAIR 302 WORKSTATION PA-107 PILLOW 303 SAFE PA-108 COUNTER STOOL 304 LOCKER Pi 09 LOUNGE CHAIR 305 STACKABLE CHAIR PA-110-12 DINING CHAIR 400 FIRE PIT WITH FITTED SCREEN PA-113 OTTOMAN 401 COMMERCIAL WASHER PA-114-16 BARSTOOL 402 COMMERCIAL DRYER Pi 17 TASK CHAIR 403 WORK CENTER PA-118 BENCH 404 WIRE SHELVING PA-200 PENDANT 405 BREAKROOM SINK PA-201 SMALL PENDANT 406 COIN OPERATED WASHER PA-202 TABLE LAMP 407 COIN OPERATED DRYER PA-203 CEILING LIGHT 408 DECORATIVE TRASH CAN PA-204 WALL SCONCE 409 DISHWASHER PA-205 FLOOR LAMP 410 MOBILE TABLE PA-300 BREAKFAST SERVING COUNTER 411 REACH -IN COOLER PA-301 BUSSING STATION 412 REACH -IN FREEZER PA-302 MEDIA WALL & COFFEE BAR 413 WORK STATION PA-303 DISH RECOVERY PA-304 HOME 2 MARKET 414 MOBILE SHELVING PA-305 FRONT DESK 415 COFFEE MACHINE 416 3-COMPARTMENT SINK PA-306 BUSINESS CENTER 418 HANDSINK PA-307 WINDOWPERCH PA-308 PERCH 418 LF PA-309-10 SERVING COUNTER MEETING ROOM 420 PRE-RIRACK/NSE PRE -RINSE WITH FAUCET PA400-02 ROLLER SHADE 420 WATER FILTER PA403 DRAPERY PANELS 421 WALL MOUNTED SHELVING PA404 ROMAN SHADE 422 SMART FRIDGE PA405 ROLLER SHADE 423 COLD WELL PA-500-07 ARTWORK 424 COMMERCIAL MICROWAVE PA-50B MIRROR 425 TOASTER CONVEYOR OVEN PA-600 TOWEL HAMPER 426 JUICE DISPENSER PA-602 UTILITYCART 427 REFRIGERATOR OF-603-05 PLANTER 428 VENTLESS EXHAUST SYSTEM OF-700 BENCH 429 MERCHANDISER REFRIGERATOR OF-701 LOUNGE CHAIR 430 MERCHANDISER FREEZER OF702 BENCH 431 WALL MOUNTED TELEVISION OF-703 OTTOMAN 432 ICE DISPENSER OF-704 CUBE TABLE 433 KETTLE RETHERMALIZER OF-705 C-TABLE 434 WAFFLE MAKER OF-706 SIDE TABLE 800 TOWEL HAMPER OF-707 SIDE TABLE 801 WATER & CUP DISPENSER OF-708 4-TOP TABLE 802 GYM WIPES DISPENSER OF-712 DINING CHAIR 803 TREADMILL OF-722 ENTRY BENCH 804 FITNESS TRAINER ELLIPTICAL PA-800-01 ROUNDTABLE 805 RECUMBENT CYCLE PA-802 RECTANGULAR TABLE 806 FREE WEIGHTS &RACK PA-803 HALF ROUND TABLE 807 WEIGHT BENCH PA-804 BREAKFAST TABLE 808 STRENGTH SYSTEM PA-805 LOG SIDE TABLE 809 MEDICINE BALLS & RACK PA-806-07 SIDE TABLE 810 EXERCISE BALL PA-808 CONSOLE TABLE 811 EXERCISE MAT PA-809 ADIRONDACK CHAIR 812 RULES SIGN PA-810 TOWEL AND FOLDING STATION 813 WALL MOUNTED TELEVISION PA-811 SIDE TABLE 814 EMERGENCY TELEPHONE BOH-812 BREAKROOM TABLE 816 TOWELHOOK OF-722 BENCH 817 WALL MOUNTED MIRROR OF-604 PLANTERS 819 WALL MOUNTED CLOCK OF-605 OF-603 PLANTERS BASE4. BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.Dom RICARDO J. MUNIZ-GULLIET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: j.t..... ., ```."o ``eO;'PEGISTE/kO 17oo161 OF ' 'u/CHITt�G4``�. owner: 1 I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513.623.9430 HOME SUITES BY HILTON CARMEL,INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA ISSUE DATE DESCRIPTION 1 JAD 12DI9.D3.D4 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY NP CHECKED BY NIL PROJECTNO, B4-134-1705 SHEET NAME INTERIOR FINISH LEGENDS & NOTES DRAWINGS NO. A=200