Loading...
HomeMy WebLinkAboutA-323 - ELEVATOR PLAN & SECTIONS/ l 1 ENLARGED ELEVATOR FIRST FLOOR PLAN A-323 1/4" = 1'-0" 3 10 11 -323 e m N C� N ELEVATOR LOBBY 227 0 r- 10'-6 5/8' CLEAR P — -m — --^ N — 15 12" 5'-0 310- 6-3 7/8" �4o'Ie 1-0 12' M 8'-9 3/4' f RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes 'ATOR TYPICAL FLOOR PLAN City of Camel �Nt��t�o>ti31WA� x DATE: 07/22/19 31 r N A.1 -4- - - -4 e PR-6.1 - R2 — — — — 52 0 0 � I ELEV#2 ELEV#1 — — o W (ELEV#2 ELEV#1 EL BA — O C q N o EL8.1 (ELEV#2 ELEV#1 O (ELEV#2 ELEV#1 12.1 LED v __ - - i K F EL8.1 ELEV#2 ELEV#1 ELEVATOR PIT LADDER IIIIIIIIIIII—III III III III III I ICI I IIIIIIII � IIIIIII-III III III I I I 3 ELEVATOR SECTION A-323 1/4" = 1'-0" PARAPETLV L3 _ 65' - 10 3/4" _PARAPET 4' - LVL2 % _- 61 1/4" 7 V O PARAPETLVL1 ROOF LVL 55' - 11 1/2" V N 5TH FLOOR 44' - 6" — 4TH FLOOR 33, - 10" N 3RD FLOOR n 23' - 2" V 3 ELEVATOR SECTION A-323 1/4" = 1'-0" PARAPETLV L3 _ 65' - 10 3/4" _PARAPET 4' - LVL2 % _- 61 1/4" 7 V O PARAPETLVL1 ROOF LVL 55' - 11 1/2" V N 5TH FLOOR 44' - 6" — 4TH FLOOR 33, - 10" N 3RD FLOOR n 23' - 2" V N 5TH FLOOR 44' - 6" — 4TH FLOOR 33, - 10" N 3RD FLOOR n 23' - 2" V ELEVATOR NOTES GENERAL 1. MINIMUM WIDTH OF DOOR OPENING IS TO BE T-6" 1 O (1.07M). 2. ONE OPERATING PANEL IS REQUIRED IN EACH CAB. 3. HEAT OR TOUCH -SENSITIVE CALL BUTTONS ARE PERMITTED PROVIDED THERE IS AN AUTOMATIC AUXILLARY RETURN IN THE EVENT OF FIRE OR PARAPET LVL 3 OTHER EMERGENCY. _ 65' - 1 O 3/4" 4. THE ELEVATOR CALL BUTTON SHALL BE VANDALISM RESISTANT AND MOUNTED NO MORE PARAPET LVL 2 n THAN 42" (107M) AFF. ELEVATOR CONTROLS AND 1 1/4" 1 TELEPHONE SHALL BE MOUNTED NO MORE THAN 48" (1.22M) AFF. 5. ALL ELEVATOR CONTROLS MUST BE EQUIPPED WITH A "DOOR OPEN" BUTTON. 6. ELEVATOR WALLS SHALL HAVE GRAB RAILS ON ALL THREE SIDES MOUNTED 32' (.81M) AFF. PARAPET LVL 1 7. A SIGN STATING "DO NOT USE ELEVATOR IN CASE "rT+T'1 60' - 1 1/8" u OF FIRE - USE STAIRS" MUST BE INSTALLED AT ELEVATOR LOBBY 527 ELEVATOR LOBBY 427 ELEVATOR LOBBY 327 ELEVATOR LOBBY 227 EACH ELEVATOR ENTRANCE ON EACH FLOOR AND IN EACH CAB. 8. PROVIDE BRAILLE MARKINGS ON ELEVATOR 9. A RECESSED TELEPHONE CABINET MUST CONTAIN A HOUSE PHONE THAT DIALS AUTOMATICALLY TO ROOF LVL THE FRONT DESK. UNLESS OTHERWISE REQUIRED 55' - 11 1/2" V BY LOCAL AUTHORITIES. 10. BENTONITE WATERPROOFING ON ALL BELOW GRADE WALLS 11. REFER TO ANSI At 17.1-407 FOR ELEVATOR ACCESSIBILITY REQUIREMENT 12. USE STAINLESS STEEL DOOR OPENINGS ON ALL FLOORS 13. USE OTIS MRL ELEVATOR SYSTEM LADDER GD-6.3 1. LADDER FINISH, GALVANIZED. 2. 311B WELD ALL AROUND FABRICATE LADDER, APPLICATION. 3. FEILD VERIFY EXACT LOCATION, COORDINATE WITH ELEVATOR SUPPLIER. STH FLOOOR n ELEVATOR NOTES 44'-6" ELEVATOR PIT/SHAFT DIMENSIONSAND CAPACITY SPEED ARE BASIS OF DESIGN SPECIFICATION ONLY. GC SHALL COORD. WITH OWNER AND SUBMIT ELEVATOR SHOP DRAWINGS /SPECIFICATIONS TO BASE4, AS SOON AS POSSIBLE BUT NO LATER THAN PRIOR TO INITIAL MUNICIPAL FILING COMMENTS RESUBMITTAL. 4TH FLOOR OIL 33' - 10" 1'1 3RD FLOOR 23'-2" % 2ND FLOOR _ _ _ 2ND FLOOR EL 8.1 w 1ST F_LOOI _- 0" T.O. Footing m -3' - 0" SUMP PIT 4 ELEVATOR SECTION AJ23 1/4" = 1'-0" ELEV LOBBY 127 1 ST FLOOR 0^ T.O. Footin -3' - 0" ELEVATOR PIT LADDER BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base4.Gom RICARDO J. MUNIZ-GULLIET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: 5 MUIV/ "iN, ```li ;CG'<�' ``�eO;'PEGIBTE/kO EE 1700161 OF IT1�G41`�. Owner: r4 t, I RIM Miami THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513.623.9430 HOME SUITES BY HILTON CARMELINDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA I ISSUE DATE DESCRIPTION 1 AO 2019.03.04 ISSUED FOR PERMIT CURRENTISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAwN BY NP CHECI9=D BY NIL PHOIECTNO. B4-134-1705 SHEET NAME ELEVATOR PLAN & SECTIONS DRAWINGS NO. A-323