HomeMy WebLinkAboutA-323 - ELEVATOR PLAN & SECTIONS/ l 1 ENLARGED ELEVATOR FIRST FLOOR PLAN
A-323 1/4" = 1'-0"
3
10 11 -323
e
m
N
C�
N
ELEVATOR
LOBBY
227 0
r-
10'-6 5/8'
CLEAR
P
— -m
—
--^
N
—
15 12" 5'-0 310-
6-3 7/8" �4o'Ie
1-0 12'
M 8'-9 3/4'
f
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
'ATOR TYPICAL FLOOR PLAN
City of Camel
�Nt��t�o>ti31WA�
x
DATE: 07/22/19
31
r
N
A.1
-4- - - -4
e
PR-6.1
- R2 — — — —
52
0 0
� I
ELEV#2 ELEV#1
— — o
W
(ELEV#2 ELEV#1
EL BA
— O
C q
N o EL8.1 (ELEV#2 ELEV#1
O
(ELEV#2 ELEV#1
12.1
LED
v __ - - i K
F
EL8.1
ELEV#2 ELEV#1
ELEVATOR
PIT LADDER
IIIIIIIIIIII—III III III III III
I ICI I IIIIIIII � IIIIIII-III III III I I I
3 ELEVATOR SECTION
A-323 1/4" = 1'-0"
PARAPETLV
L3 _
65' - 10 3/4"
_PARAPET 4' - LVL2 % _-
61 1/4" 7
V
O
PARAPETLVL1
ROOF LVL
55' - 11 1/2" V
N
5TH FLOOR
44' - 6" —
4TH FLOOR
33, - 10"
N
3RD FLOOR n
23' - 2" V
3 ELEVATOR SECTION
A-323 1/4" = 1'-0"
PARAPETLV
L3 _
65' - 10 3/4"
_PARAPET 4' - LVL2 % _-
61 1/4" 7
V
O
PARAPETLVL1
ROOF LVL
55' - 11 1/2" V
N
5TH FLOOR
44' - 6" —
4TH FLOOR
33, - 10"
N
3RD FLOOR n
23' - 2" V
N
5TH FLOOR
44' - 6" —
4TH FLOOR
33, - 10"
N
3RD FLOOR n
23' - 2" V
ELEVATOR NOTES
GENERAL
1.
MINIMUM WIDTH OF DOOR OPENING IS TO BE T-6"
1 O
(1.07M).
2.
ONE OPERATING PANEL IS REQUIRED IN EACH
CAB.
3.
HEAT OR TOUCH -SENSITIVE CALL BUTTONS ARE
PERMITTED PROVIDED THERE IS AN AUTOMATIC
AUXILLARY RETURN IN THE EVENT OF FIRE OR
PARAPET LVL 3
OTHER EMERGENCY.
_
65' - 1 O 3/4"
4.
THE ELEVATOR CALL BUTTON SHALL BE
VANDALISM RESISTANT AND MOUNTED NO MORE
PARAPET LVL 2 n
THAN 42" (107M) AFF. ELEVATOR CONTROLS AND
1 1/4" 1
TELEPHONE SHALL BE MOUNTED NO MORE THAN
48" (1.22M) AFF.
5.
ALL ELEVATOR CONTROLS MUST BE EQUIPPED
WITH A "DOOR OPEN" BUTTON.
6.
ELEVATOR WALLS SHALL HAVE GRAB RAILS ON
ALL THREE SIDES MOUNTED 32' (.81M) AFF.
PARAPET LVL 1
7.
A SIGN STATING "DO NOT USE ELEVATOR IN CASE
"rT+T'1 60' - 1 1/8" u OF FIRE - USE STAIRS" MUST BE INSTALLED AT
ELEVATOR
LOBBY
527
ELEVATOR
LOBBY
427
ELEVATOR
LOBBY
327
ELEVATOR
LOBBY
227
EACH ELEVATOR ENTRANCE ON EACH FLOOR AND
IN EACH CAB.
8. PROVIDE BRAILLE MARKINGS ON ELEVATOR
9. A RECESSED TELEPHONE CABINET MUST CONTAIN
A HOUSE PHONE THAT DIALS AUTOMATICALLY TO
ROOF LVL
THE FRONT DESK. UNLESS OTHERWISE REQUIRED
55' - 11 1/2" V
BY LOCAL AUTHORITIES.
10. BENTONITE WATERPROOFING ON ALL BELOW
GRADE WALLS
11. REFER TO ANSI At 17.1-407 FOR ELEVATOR
ACCESSIBILITY REQUIREMENT
12. USE STAINLESS STEEL DOOR OPENINGS ON ALL
FLOORS
13. USE OTIS MRL ELEVATOR SYSTEM
LADDER
GD-6.3
1. LADDER FINISH, GALVANIZED.
2. 311B WELD ALL AROUND FABRICATE LADDER,
APPLICATION.
3. FEILD VERIFY EXACT LOCATION, COORDINATE WITH
ELEVATOR SUPPLIER.
STH FLOOOR n
ELEVATOR NOTES
44'-6"
ELEVATOR PIT/SHAFT DIMENSIONSAND CAPACITY
SPEED ARE BASIS OF DESIGN SPECIFICATION ONLY. GC
SHALL COORD. WITH OWNER AND SUBMIT ELEVATOR
SHOP DRAWINGS /SPECIFICATIONS TO BASE4, AS SOON
AS POSSIBLE BUT NO LATER THAN PRIOR TO INITIAL
MUNICIPAL FILING COMMENTS RESUBMITTAL.
4TH FLOOR OIL
33' - 10" 1'1
3RD FLOOR
23'-2" %
2ND FLOOR _ _ _ 2ND FLOOR
EL 8.1
w
1ST F_LOOI _-
0"
T.O. Footing
m
-3' - 0"
SUMP PIT
4 ELEVATOR SECTION
AJ23 1/4" = 1'-0"
ELEV
LOBBY
127
1 ST FLOOR
0^
T.O. Footin
-3' - 0"
ELEVATOR PIT LADDER
BAS E4
BASE4
2901 CLINT MOORE ROAD, #114
BOCA RATON, FLORIDA 33496
888.901.8008 www.base4.Gom
RICARDO J. MUNIZ-GULLIET, All
5453 NW 106TH DR
CORAL SPRINGS, FL 33076
Seal:
5 MUIV/ "iN,
```li
;CG'<�'
``�eO;'PEGIBTE/kO
EE
1700161
OF
IT1�G41`�.
Owner:
r4
t, I
RIM Miami
THE WITNESS GROUP
600 ENTERPRISES DRIVE
LEWIS CENTER,OH
513.623.9430
HOME
SUITES BY HILTON
CARMELINDIANA
PROTOTYPE VERSION-V2.2 2016
REVISION: MAY 2016
DECOR PACKAGE: TRIBECA
ISSUE
NO.
DELTA
I ISSUE DATE
DESCRIPTION
1
AO
2019.03.04
ISSUED FOR PERMIT
CURRENTISSUE
ISSUED FOR PERMIT
CURRENT ISSUE DATE
2019.03.04
DRAwN BY
NP
CHECI9=D BY
NIL
PHOIECTNO.
B4-134-1705
SHEET NAME
ELEVATOR PLAN &
SECTIONS
DRAWINGS NO.
A-323