Loading...
HomeMy WebLinkAboutA-503 - WINDOW SCHEDULEWINDOW SCHEDULE TYPE MARK LOCATION ELEV. TYPE WIDTH HEIGHT HEAD HEIGHT SILL HEIGHT FRAME MATERIAL GLASS TYPE DESCRIPTION 1 ST FLOOR W1 ELEVATOR LOBBY A 81.099 7' — 4 3/411 7' — 4 3/411 0" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W3 HOUSEKEEPING C 51.099 6' — 2 1/411 7' — 4 3/411 1' — 2 1/2" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W5 LAUNDRY/POOL EQUIP E 51.099 2' — 2" 5' — 2" 31. 0" ALUMINUM LOUVERS LOUVERS 2ND FLOOR W1 ELEVATOR LOBBY A 81.011 71.4 3/4" 7' — 7 7/8" 3 1/811 CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W2 GUESTROOMS B 5' — 0" 6' — 1 1/411 6' — 1 1/411 0" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W3 HOUSEKEEPING C 5' — 0" 6' — 2 1/411 T— 7 7/8" 1' — 5 5/811 CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W4 CORRIDOR D 4' — 7" 6' — 2 1/411 6' — 1111 8 3/411 CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED 3RD FLOOR W1 ELEVATOR LOBBY A 81.011 7' — 4 3/411 T— 7 7/8" 3 1/811 CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W2 GUESTROOMS B 5' — 0" 6' — 1 1/411 6' — 1 1/411 loll CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W3 HOUSEKEEPING C 5' — 0" 6' — 2 1/411 T— 7 7/8" 1'— 5 5/8" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W4 CORRIDOR D 4' — 7" 6' — 2 1/411 6' — 1111 8 3/411 CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED 4TH FLOOR W1 ELEVATOR LOBBY A 81.011 7' — 4 3/411 T— 7 7/8" 3 1/8" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W2 GUESTROOMS B 5' — 0" 6' — 1 1/41' 6' — 1 1/41' 0" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W3 HOUSEKEEPING C 5' — 0" 6' — 2 1/411 T— 7 7/8" 1'— 5 5/811 CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W4 CORRIDOR D al 7" 6' — 2 1/41' 6' — 11" 8 3/4" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED 5TH FLOOR W1 ELEVATOR LOBBY A 81.019 7' — 4 3/41' T— 7 7/8" 3 1/8" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W2 GUESTROOMS B 5' — 0" 6' — 1 114" 6' — 1 1/41' 0" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W3 HOUSEKEEPING C 5' — 0" 6' — 2 1/41' T— 7 7/8" Ill— 5 5/811 CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED W4 CORRIDOR D al 7" 6' — 2 1/4" 6' — 11" 8 3/4" CLEAR ANODIZED, ALUMINUM MULLION CLEAR TEMPERED * 4 (Y 4 0' X I� 1 W1 3/4" - - 1'-0" WATER -RESISTIVE BARRIER COATING RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �NtY�l�o>�WA� x DATE: 07/22/19 STEP 01 APPLY DIAGONAL STRIP OF FLASHING MESH & FLASHING AT CORNERS -SEE NOTES I&3 STEP 82 2 W2 3/4" - - 1'-0" SHALL EXTEND TO INTERIOR FACE OF OPENING. L AND JAMB DETAILS FOR FLASHING INTEGRATION. NDOW HEAD & 4" TO 6" BELOW BOTTOM EDGE OF NAILING FLANGE. DUTER EDGES OF JAMB FLASHING. )MPLETE GUEST ROOM MOCK UP TO INCLUDE EXTERIOR WINDOW FOR OWNER/ARCHITECT APPROVAL. T-0, 5--0" STEP #4 STEP 05 INSTALL APPROVED SEALANT BEHIND WINDOW FLANGES (JAMB & HEAD ONLY) INSTALL WINDOW IN OPENING INSTALL FASTENERS AT APPROVED SPACING INTO NAILING FLANGES T J CHANNE a e L 4 7 STEP 06 J CHANNEL IS NAILED TO THE WINDOW HEADER AND TRIMMERS AFTER THE WINDOW FRAME IS SET. DRYWALL SLIPS INTO THESE CHANNELS. APPLYFLASHING SYSTEM AT JAMBS -SEE NOTES I&3 STEP 07 GENERAL GLAZING NOTES 1. TEMPERED LOW-E GLASS WITH 2O-30h TINT ON GUESTROOMS. 2. 1ST FLOOR CLEAR GLAZING 3. ALL OPERATING AND FIXED ALUMINUM WINDOWS FACTORY GLAZING ONLY USE QUAKER, WOJAN OR EQUIVALENT 4. ALL EXTERIOR AND INTERIOR WINDOWS ARE FIXED TYPE WITH NO OPERABLE PANELS. 5. ALL INTERIOR GLAZING TO BE CLEAR. 6. ALL GLASS IN HAZARDOUS AREAS AND ALL GLASS WITHIN 18" OF FLOOR AND/OR WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR JAMB IN A CLOSED POSITION SHALL BE TEMPERED GLASS PER SECTION 2406.3 OF THE I.B.C. 7. ALL EXTERIOR ALUMINUM FRAMES TO BE THERMALLY BROKEN. 8. FINISHED PTAC LOUVERS TO MATCH WINDOW FRAMES. 9. COORDINATE WINDOW SILL HEIGHTS WITH REVEAL IN BUILDING ELEVATIONS. 10. ALL GLAZING SURROUNDED BY LAMINATE COLORED PANELS AT ENTRY AREAS TO BE PREFINISHED TO MATCH ADJACENT COLOR ON EXTERIOR SIDE ONLY PROJECT NOTES: • ALL OPERABLE WINDOWS PROVIDED IN PUBLIC GUEST ACCESSIBLE SPACES AND IN ACCESSIBLE GUEST ROOM TYPES MUST MEET ALL ACCESSIBILITY REQUIREMENTS PERTAINING TO REACH RANGE, OPERATING CONTROLS AND CLEAR FLOOR SPACE - HARDWARE AND WINDOW OPERATION MUST BE NO GREATER THAN WINDOWS MUST BE STANDARD ALUMINUM STOREFRONT, THERMALLY BROKEN, WITH CLEAR DUAL GLAZING WITH A FACTORY PAINTED FINISH. LOUVERS FOR THRU-WALL Hi UNITS MUST BE INTEGRATED WITH WINDOWS AND PROVIDED BY WINDOW MANUFACTURER GENERAL GUESTROOM GLAZING NOTES 1. MIN STC 33 ON GUESTROOMS WINDOWS 2. MIN STC 41 IF HOTEL IS BY HIGHWAYOR AIRPORT 3. "T" SAFETY GLAZING REQUIRED WINDOWS-BAKED/POLYESTER PAINT/KYNAR TYPE FINISH FRAME WITH CLEAR GLASS -DUAL GLAZED THERMLLY BROKEN {ID 'PLY FLASHING 'STEM AT HEAD - :E NOTES 1, 3 & 4 STEP 08 BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.com RICARDO J. MUNIZ-GULLIET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: ip 17oo161 — OF 4``�. ' All ill T110 Owner: f� A=491 ra THE WITNESS GROUP 60C ENTERPRISES DRIVE LEWIS CEH 513.fi23.9430.9430 HOME SUITES BY HILTON CARMEL,INDIANA PROTOTYPE VERSION42.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA I ISSUE DATE DESCRIPTION 1 AO 12019.03.N ISSUEDFORPERMIT CURRENTISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY NP CHECKEDBY NIL PROJECTNO. B4-134-1705 SHEET NAME WINDOW SCHEDULE DRAWINGS NO. A=503