Loading...
HomeMy WebLinkAboutA-603 - EXTERIOR ELEVATION & BUILDING SECTION-4PARAPET LVL 2_ PARAPET LVL 1 < 60' - 1 118" ROOF LVL v 55'-111/2" N 5TH FLOOR 6, 0 rill 4TH FLOOR v 330_10„ -o to LA 3RD FLOOR -2" 0 2ND FLOOR �2'-6" ,1ST FLOOR 0" 3 ELEVATION 4 ,maeo 1/81, _ 11-01, lPARAPETLVI-3 65'...- 10 3/4" Jkt PARAPET LVL 2 crn v 64' - 1 1/4" - — Jkt PARAPET LVLI - — v 60' - 1 1/8" � QlROOF LVL 55' - 11 1/2" 5TH FLOOR_ 44' - 6" N aSt m JIL-4TH FLOOR — q/ 33' - 1 O„ o- :o 'y o 3RD FLOOR `s t/ 23' - 2' — — N eii CAN 2ND FLOOR — _ v 12' - 6" ,o cl St iV o � 18T FLOOR ill 01, o T.O. FDDti�7cn - On 1 BUILDING SECTION #6 ,mam 1/8"=11-0" EXTERIOR FINISH LEGEND Material MARK MATERIAL & FINISH : Image BR-1 IBRICK VENEER- HEBRON ONYX RELEASED FOR CONSTRUCTION Subject o compliance and Local all regulations of State and Local Codes _ City of Camel �101Y�t�D>AC\� x DATE: 07/22/19 PAINTED Tt CANOPY W, TRELLIS — i GENERAL BUILDING GENERAL ELEVATION NOTES GENERAL SIGNAGE NOTES SECTION NOTES 1. REVIEW ALL SIGHTLINES AROUND PROPERTY BEFORE LOCATING ROOFTOP EQUIPMENT.VERIFY ALL EQUIPMENT IS ADEQUATELY SCREENED. 1. ALL SIGNAGE INDICATED FOR ILLUSTRATIVE PURPOSES ONLY. LOCATION,SIZE,ETC. TO BE DETERMINED ONAN INDIVIDUAL PROJECT 2. GC TO PROVIDE A MOCK WALL SHOWING A FULL WINDOW INSTALL WITH FLASHING.GC CAN USE A PROPORTIONALLY SCALED DOWN WINDOW IN LUE OF FULL SIZE WINDOW. BASIS. 2. MINIMUM 3/4"PLYWOOD BACKERBOARD REQUIRED AT SIGN LOCATIONS. AREA SHOULD COVER ENTIRE LENGTH AND HEIGHT OF FASCIA OR 3. ALL EXTERIOR VENTS, GRILLES, MECHANICAL LOUVERS O EXTERIOR HOLLOW METAL DOORS TO BE FINISHES TO MATCH ADJACENT EXTERIOR MATERIAL. SPACE AVAILABLE FOR SIGN. 1. ARCHITECTURAL FINISH FLOOR ELEVATIONS REFER TO TOP OF FINISH FLOOR ASSEMBLY. SEE q, ALL BUILDING PERMITS TO BE CONSISTENT WITH THE APPROVED SITE PLAN. THE PLANNING DEPARTMENT DOES NOT REVIEW BUILDING PERMIT PLAN SETS, SO IS THE 3. ELECTRICAL AND FINAL CONNECTION BY CONTRACTOR. ELECTRICAL REQUIREMENTS MAY BE OBTAINED FROM SIGN COMPANY. STRUCTURAL ES FOR TOP OF STRUCTURE AND DEVELOPER'S RESPONSIBILITY TO ENSURE THAT ELEVATIONS SUBMITTED IN THE BUILDING PERMIT SET MATCH THOSE APPROVED DURING THE SITE PLAN REVIEW PROCESS. 4. PERMANENT SS INTERIOR ALLPARAPETSERE LOCATED TO BE PROVIDED BY CONTRACTOR. S AREINSIDE HT BEARING HEIGHT ELEVATIONS IF THE ELEVATIONS DO NOT MATCH WILL DELAY THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY AT THE ENO OF CONSTRUCTION, AND MAY FURNISH AND RI ELECTRICAL ICE CONTRACTOR TO AL CONTRACTOR TO FURNISH AND CONNECT PRIMARY ELECTRICAL SERVICE INSIDE PARAPET WALL THETHOSE NECESSITATE MODIFICATIONS TO THE CONSTRUCTED BUILDING. NECESSITATE CON TRUCT D BUILDING. 5. PROVIDE WEATHER PROOF ACCESS DOORS AT ROOF LEVEL OR ANYWHERE EXTERIOR/ OR WET CONDITIONS MAY APPLY6. 5. ALL VENT PIPES, ETC. EXTENDING ABOVE THE ROOF SURFACE MUST BE PAINTED A COLOR THAT BLENDS WITH THE ROOF COLOR. GUESTROOMS OR PUBLIC SPACES WITH SIGNAGE ON EXTERIOR WALLS MUST HAVE ELECTRICAL PENETRATIONS AND/OR REMOTE 6. ARCHITECTURAL FINISH FLOOR ELEVATIONS REFER TO TOP OF FINISH FLOOR ASSEMBLY. SEE STRUCTURAL DWGS FOR TOP OF STRUCTURE AND BEARING HEIGHT TRANSFORMERS COORDINATED AND/OR INSTALLED PRIOR TO CLOSING UP THE WALL. PENETRATION LAYOUT MAY BE OBTAINED FROM SIGN ELEVATIONS COMPANY ♦6 ) BAS F. BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GULLIET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: U IV/ /l `aa5,rM 4D —G STE/ CG�i = U; noolsl .m_ OF Owner: N ♦nii 1 , 11 ` V THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513.623.9430 HOME SUITES BY HILTON " CARMEL,INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA I ISSUE DATE DESCRIPTION 5 IA4 2019.04.23 CITY COMMENTS 1 IAO 12019.03.04 ISSUEDFORPERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.25 DRAWN BY NP CHECKED BY NILPROIECTNO. B4-134-1705 SHEET NAME EXTERIOR ELEVATION & BUILDING SECTION-4 DRAWINGS NO. A=603