HomeMy WebLinkAboutA-803 - CONSTRUCTION DETAILS @ ROOFROOF DRAIN T SLOPE 1/4:/FT
SLOPE
TAPERED' INSULATION SLOPE 1/4:/FT
do
nommoso
• •
a -
• -•• s • •-
•
1 DETAIL (a)ROOF DRAIN
,05 1/211 = 1 L-0n
NEOPRENESEAL
METAL COUNTER FLASHING
OR EQUIPMENT FLANGE
TAPERED INSULATION
SINGLE PLY ROOF
SYSTEM - SEE SPECS
LAP SPLICE
4 EQUIPMENT CURB
1 1/21, = 1'-01,
SUPPLY OR
RETURN DUCT "3
1�
SEALANT
CLAMPING RING
METAL STORM COLLAR y
TRANSITION FROM DUCT
PROFILE TO CURB
1/2"EXTERIOR
SHEATHING BOARD
BEYOND ATTACHED
TO T
�Ilra
�IIIN 7■
SEE MECHANICAL FOR "' V "
CONTINUATION
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulatims
of State and local Codes NT PENETRATION
City of Camel ((��
`�vmlUtlBnrJnwJaL
DATE: 07/22/19
MECH. EQUIPMENT
- SEE MECHANICAL
MECH EQUIPMENT
CURB-SEESPECS
MEMBRANE BASE
FLASHING
2xTREATED WOOD
e BLOCKING AS
REQ'D
TAPERED
'ro INSULATION
RIGID INSULATION
FACTORY FABRICATED
VANES (TYPICAL)
1" THICK EXTERNAL
INSULATION - SEE MECH
TREATED 2x4 WOOD FRAMING
MEMBRANE FLASHING
TAPERED INSULATION
RIGID INSULATION
SINGLE PLY ROOF
SYSTEM - SEE SPECS
LAP SPLICE
BATT INSULATION
ROOF DRAIN — SEE PLUMBING
ROOF SUMP RECEPTOR
SINGLE PLY ROOF
SYSTEM — SEE SPECS
TAPERED INSULATION
RIGID INSULATION
PROVIDE SLOPE TO
ROOF DRAIN
UNDERLOCK CLAMP
SEE PLUMBING FOR
CONTINUATION
NOTE: COORDINATE LOCATION OF ROOF DRAINS W/STRUCTURAL
/ 2 ROOF DRAIN PENETRATION
PIPE"'" A"^
MATI
VARI
PLUS
SEAL
STAII
CLAI,
/ 5 1 ROOF VENT STACK PENETRATION
1 1/21, = 1'-01,
CLAMP AND SEALANTAT
TOP OF PREMOLDED
EAD VENT PIPE COVER
a
/�.mil/�'��a �1 ROOF CONDUIT PENETRATION
1 o = 1'-0"
STACK PIPE FLASHING
LAP SEALANT
TAPERED INSULATION
SINGLE PLY ROOF SYSTEM
-SEE SPECS
RIGID INSULATION
2x TREATED WOOD NAILERS
2 X 10 WOOD JOIST
1/2" RESILIENT CHANNEL
5/8" TYPE X GYPSUM BOARD
MEMBRANE BASE FLASHING APPLIED AT
PERIMETER OF PREMOULDED LEAD VENT PIPE
COVER PERIMETER WITH 22'-0" SQUARE
FLANGE
ROOF MEMBRANE ADHERED TO TAPERED
POLYISOCYANURATE INSULATION ADHERED
TO TOP PRECAST CONCRETE ROOF PLANKS
SEAL PERIMETER OF
PIPE PENITRARION
BATT INSULATION
FINISHED CEILING
MATERIAL AND
HEIGHT VARY
FABRICATE CRICKETS USING TAPERED
RIGID RIGID POLYISOCYANURATE
INSULATION AT PERIMETER OF ROOF
DRAIN AS INDICATED ON ROOF PLAN
TO PROVIDED A MINIMUM SLOPE OF
1/8" PER FOOT IN ALL AREAS
MINIMUM THICKNESS OF RIGID
INSULATION AT DRAIN CLAMPING RING
SHALL BE 2"
FILL ENTIRE FLOOR
SYSTEM CAVITY FULL OF
NON-COMBUSTIBLE BLOW
IN INSULATION (MIN R-38)
/ s
ROOF DRAIN
PENETRATION
DETAIL
dk�"
CONT. CLEAT
SECURED TO WOOD
NAILER
WEATHER RESISTANT
BARRIER ON 3/4"
EXTERIOR GRADE
PLYWOOD SHEATHING
ROOF SIDE FLANGE
METAL SLEEVE (BY
OTHERS)
FLEXIBLE SHT. FLASHING
W /CONT. SEALANT @ ALL
EXPOSED EDGES. TURN
INLET MIN. 2"
SLOPE 1/4" / FT.
EDPM
MEMBRANE
MEMBRANE FLASHING OVER
SHEET LEAD FLASHING AT ROOF
DRAIN SUMP PERIMETER
FASTENED WITHIN DRAIN
CLAMPING RING (LEAD
FLASHING SHALL BE 3'-0"
SQUARE)
RIGID POLYISOCYANURATE
INSULATION TAPERED TO
ROOF DRAIN SUMP
METAL CLAMPING RINGS
SHALL BE CONCEALED FROM
VIEW IN ALL AREAS
METAL BLOCKING
PRE —FINISHED ALUM.
COPING
9 7/8
CONT. CLEAT
SECURED W/NAILER
CONT. SEALANT
METAL SCUPPER
ASSEMBLY 61/2"x14" _
24 GA. GALV. STL r
CONDUCTOR HEAD `
W/OVERFLOW OPENING
OVERFLOW
OPENING
7/8" PORTLAND CEMENT
PLASTER ON SELF —
FURRING METAL LATH
( c LOW ROOF DETAIL @ SCUPPER EIFS
1 1/2" = 1'-0"
WEATHER RESISTANT BARRIER
ON LAYERS 518" EXTERIOR GYP
SHEATHING. EXTEND WEATHER
BARRIER OVER PARAPET
BLOCKING CONT.
COLLECTOR HEAD
PREFABRICATED FROM 24
GA G90 GALV. PRE -
FINISHED IN KYNAR 500
PAINT FINISH (COLOUR
PER ARCHITECT)
PREFABRICATED 24 GA G-90
GALVANIZED SCUPPER FLASHING
RIVET (CLOSED END 4-2) AND SEALANT
N14 HEX HEAD TYPE'A 5/8" S/S
SEALING WASHERRAINTED AS
APPROVED BY ARCHITECT
ATTACHMENT FLANGE
PREDRILL TO RECEIVE
FASTENER
DROP TUBE- SEALENT AND
CLOSED -END SIS RIVET (4-2)
LEADER ATTACH TO
DROP TUBE
V-2•
♦�10
BAS E4
BASE4
2901 CLINT MOORE ROAD, #114
BOCA RATON, FLORIDA 33496
888.901.8008 www.base-4.com
RICARDO J. MUNIZ-GULLIET, AIA
5453 NW 106TH DR
CORAL SPRINGS, FL 33076
Seal:
j11MUAl/ 111*
`o
z :r =
OF
DIASJ."o 0`�
ITIeGN1x`
owner
lv m0000�
THE WITNESS GROUP
600 ENTERPRISES DRIVE
LEWIS CENTER,OH
513.623.9430
HOME
SUITES BY HILTON
"
CARMEL,INDIANA
PROTOTYPE VERSION-V2.2 2016
REVISION: MAY 2016
DECOR PACKAGE: TRIBECA
ISSUE
NO.
DELTA
ISSUE DATE
I DESCRIPTION
1
IAO
12019.03.04
JISSUED FOR PERMIT
CURRENT ISSUE
ISSUED FOR PERMIT
CURRENT ISSUE DATE
2019.03.04
DRAWN BY
NP
CHECKED BY
NL
PROJECT NO.
B4-134-1705
SHEET NAME
CONSTRUCTION
DETAILS @ ROOF
DRAWINGS NO.
A=803