HomeMy WebLinkAboutE-001 - GENERAL NOTES, LEGENDS AND ABBREVIATIONSGENERAL NOTES LEGENDS DRAWING INDEX SYMBOL I ELECTRICAL 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE FOLLOWING a. ALL DISCREPANCIES OF DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WIRING DEVICES SHEET SHEET NAME CURRENT U CURRENT REVISION U CODES/STANDARDS:INTERNATIONAL NATIONAL ELECTRICAL FIRE WRITING INAMPLETO OF SUBMISSION OFABID IELD NUMBER REVISION DATE DESCRIPTION ERNATI NAL ENERGY INTERNATIONAL ENERGYTION. CONSERVATION CODE, AND ALL LOCALCODE ORDINANCES, AND ALLL LOCAL LCOD AC EPTANCTIME AND ELECTRICAL DRAWING CONSTITUTES ACCEPTANCE OF FIELD CONDITIONSAND ELECTRICAL DRAWINGS. OFCONDNS ITIONS ® MOUNTED AT IB"AFF ON CENTER, UNO. NEMA 5OLATE E-001 GENERAL NOTES, LEGENDS AND ABBREVIATIONS 2019.03.04 ISSUED FOR PERMIT REGULATIONS, AND REGULATIONS, AND THE AUTHORITY HAVING JURISDICTION. fIXX G GROUND IG =ISOLATED GROUND E-101 ELECTRICAL DETAILS-1 2019.03.D4 ISSUED FOR PERMIT 9. PROVIDE MEANSTURNISH AND INSTALL COMPLETE AND READY FOR USE. AC=MOUNTED 4"ABOVE COUNTER E-102 ELECTRICAL DETAILS-2 2019.03.D4 ISSUED FOR PERMIT 2. ALL ELECTRICAL WORK PROVIDED FOR THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CRITERIA: USB= UNIVERSAL SERIAL BUS E-103 ELECTRICAL DETAILS-3 2019.03.D4 ISSUED FOR PERMIT 10. DRAWINGS DO NOT NECESSARILY INDICATE THE ACTUAL ROUTES OF CONDUIT. WHERE INDICATED, THEY n A) TRADE SIZE CONDUIT SMALLER THAN I/21NCH SHALL NOT BE USED. SHALL BE FOLLOWED AS CLOSELY AS PROPER COORDINATION WITH THE WORK OF OTHER TRADES AND x GFCI= GROUND FAULT CIRCUIT INTERRUPTER E-104 ELECTRICAL DETAILS-4 2D19DOD4 ISSUED FOR PERMIT E ELECTRICAL DETAILS 2019.03.D4 ISSUED FOR PERMIT SPACES WILL PERMIT. WHERE CONDUIT RUNS ARE NOT SHOWN ON THE DRAWINGS, COORDINATE CONDUIT H= HORIZONTAL OUTLET B) CONDUIT ABOVE GRADE AND NOT EXPOSED TO WEATHER SHALL BE PVC, ENT 8 MC. RUNS WITH THE WORK OF OTHER TRADES AND STRUCTURE. SIMPLIFY INSTALLATION WHERE POSSIBLE, BUT V = VERTICAL OUTLET EA-1D6 06 GRAM GROUNDING RISER DIAGRAM 2019.03.D4 ISSUED FOR PERMIT SUBJECT TO APPROVAL OF ARCHITECT FOR VISUAL AND STRUCTURAL REASONS. IT INOT WITHIN THE WP= WEATHER PROOF C) CONDUIT BELOW GRADE AND PENETRATIONS AT GRADE SHALL BE SCHEDULE 40 PVC EXCEPT TURNS. SCOPE OF THE DRAWINGS TO SHOW ALL NECESSARY OFFSETS, BENDS, PULL BOXES,, AND OBSTRUCTIONS. E-107 POOL GROUNDING DETAIL 2019.03.D4 ISSUED FOR PERMIT E-200 SITE POWER PLAN 2019.03.04 ISSUED FOR PERMIT THE DRAWINGS ARE NOT INTENDED TO BE SCALED AND REFER TO THE ARCHITECTURAL DRAWINGS FOR NEMA 5-20R DUPLEX RECEPTACLE MOUNTED AT 18"AFF ON CENTER, SPLIT D) CONDUITABOVE GRADE AND EXPOSED TO WEATHER SHALL BE SCHEDULE 80 PVC. DIMENSIONS WIRED, UNO. E-201 1ST FLOOR POWER PLAN 2019.03.04 ISSUED FOR PERMIT E) WIRE SIZE SMALLER THAN #12 Awg. SHALL NOT BE USED FOR POWER CKT. #18 Awg.SHALL BE USED FOR LOW NEMA 6-20R DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, DEDICATED E-2D2 2ND FLOOR POWER PLAN 2019.01 ISSUED FOR PERMIT VOLTAGE CKT. 11. LABOR FOR THE INSTALLATION OF MATERIALS AND EQUIPMENT PROVIDED UNDER THE ELECTRICAL CIRCUIT, UNO. E-2D3 3RD FLOOR POWER PLAN 2019.03.D4 ISSUED FOR PERMIT F) BRANCH CIRCUIT WIRING PROVIDED BYTHE ELECTRICAL CONTRACTOR SHALL BE COPPER; FEEDER & SERVICE CONTRACTORS SCOPE OF WORK SHALL BE PERFORMED IN A NEAT AND FIRST CLASS WORKMANSHIP LIKE ® NEMA 5-20R DUPLEX RECEPTACLE FLOOR MOUNTED, UNO. E-204 4TH FLOOR POWER PLAN 2019.03.04 ISSUED FOR PERMIT WIRING SHALL BE ALUMINUM. MANNER BY THOSE EXPERIENCED AND QUALIFIED OF THE PROPER TRADE AND SHALL BE IN COMPLIANCE E-2D5 5TH FLOOR POWER PLAN 2D19DOD4 ISSUED FOR PERMIT WITH THE SPECIFIC REQUIREMENTS OF THE CONTRACT DRAWINGS, AND ALL CODES, ORDINANCES OF ��LL G) ALL CONDUCTORS SHALL HAVE A MINIMUM TEMPERATURE RATING OF 75 DEGREES C. (TYPE TRAIN STATUES, ETC. APPLICABLE. YYYY 0 NEMA 5-20R DUPLEX RECEPTACLE, CEILING MOUNTED, UNO. E-2D6 ROOF POWER PLAN 2D19DOD4 ISSUED FOR PERMIT E-207 ENLARGED FLOOR POWER PLAN-1 2019.03.D4 ISSUED FOR PERMIT OR TYPE THHN), 98% COPPER OR ALUMINUM. 12. FIELD DETERMINE EXACT INSTALLATION LOCATION OF FIRE PROTECTION REQUIREMENTS UNDER THE NFPA It NEMA 5-2OR DOUBLE DUPLEX RECEPTACLE MOUNTED AT 18" AFF ON CENTER, UNO.E-208 ENLARGED FLOOR POWER PLAN-2 2019.03.04 ISSUED FOR PERMIT H)WHERE POSSIBLE, EXCEPT AS SHOWN OTHERWISE ON THE DRAWINGS,ALL CONDUIT SHALL BE RUN CONCEALED E-209 TYPICAL UNIT ELECTRICAL POWER PLANA 2019.03.04 ISSUED FOR PERMIT BELOW GRADE,WITHIN WALLS OR ABOVE CEILING. AND MANUFACTURER'S WRITTEN INSTRUCTIONS. INCLUDE ALL FIRE ALARM SYSTEMS AND DETECTION T NEMAATED 5-20R DOUBLE DUPLEX RECEPTACLE MOUNTED AT 18"AFF ON CENTER, E-210 TYPICAL UN IT ELECTRICAL POWER PLAN-2 2019.03.04 ISSUED FOR PERMIT DEVICES. DEDICATED CIRCUITS UNO. CONDUCTOR AWG AND STRANDED. ANDSMALIDO ER ONLY I) CONDUCTORS12 7®F E-302 PANEL SCHEDULE-1 2019.03.04 ISSUED FOR PERMIT ED,ESOLID NONE STRANDED, THAT ONLY SOLID #12 CONDUCTOR#12AWGMAYSED BE SOLID OR STRANDED, EXCEPT THAT ONLY #12 AWG SOLID OR ONLY #12 AWG 13. ALL MOUNTING HEIGHTS INDICATED ARE MEASURED FROM FINISHED FLOOR UNLESS OTHERWISE NOTED. EJ02 PANEL SCHEDULE -II 2019.03.04 ISSUED FOR PERMIT STRANDED SHALL BE USED. ® NEMA 5-20R DOUBLE DUPLEX RECEPTACLE FLOOR MOUNTED, UNO. J) THERE SHALL BE NO MORE THAN 270 DEGREES TOTAL TURN OR 150 FEET BETWEEN PULL POINTS IN CONDUIT 14. PROVIDE TEMPORARY LIGHTING, POWER, AND WIRING SYSTEMS FOR USE OF ALL TRADES, E-303 PANEL SCHEDULE -III 2019.03.04 ISSUED FOR PERMIT ADEQUATE FOR ENTIRE NEEDS OF THE PROJECT. E304 PANEL SCHEDULE -IV 2019.03.04 ISSUED FOR PERMIT RUNS. NEMA 5-20R DOUBLE DUPLEX RECEPTACLE CEILING MOUNTED UNO. E-305 PANEL SCHEDULE-V 2019.03.04 ISSUED FOR PERMIT K ALL ELECTRICAL RECEPTACLES IN THE BATHROOM OUTSIDE AREAS AND AIR CONDITIONING I HEATING I ) 15. CONNECT ALL MOTORS STARTERS CONTROLS DISCONNECT SWITCHES CIRCUIT BREAKERS ETC. EJO6 PANEL SCHEDULE -VI 2019.03.04 ISSUED FOR PERMIT REFRIGERATION AREAS SHALL BE GFCI PROTECTED. WHETHER FURNISHED UNDER THIS CONTRACT BY THE GENERAL CONTRACTOR, OTHER SUB -CONTRACTOR, `mm'l NEMA 5- 20R SINGLE DUPLEX RECEPTACLE MOUNTED AT 18"AFF ON CENTER,UNO. OR BY THE OWNER. T T E-307 PANEL SCHEDULE-VII 2019.03.04 ISSUED FOR PERMIT L) MOUNTING HEIGHT OF WALL MOUNTED CONTROLS AND RECEPTACLES SHALL FOLLOW THE GIVEN DIAGRAM 16. PROVIDE PULL WIRES WHEN EMPTY CONDUITS ARE SHOWN ON THE PLANS. fA SPECIAL RECEPTACLE SEE PLAN NOTES FOR TYPE. E-308 PANEL SCHEDULE-Vill 2019.03.04 ISSUED FOR PERMIT BELOW, UNLESS COMPARABLE CONTROLS OR OUTLETS (THAT PERFORM THE SAME FUNCTIONS) ARE PROVIDED `�. E-309 ELECTRICAL RISER DIAGRAM 2019.03.04 ISSUED FOR PERMIT WITHIN THE SAME AREA AND ARE ACCESSIBLE. 17. PROVIDE LIGHT FIXTURES AS SELECTED BYARCHITECT,OR AS SPECIFIED. Q JUNCTION BOX FOR ELECTRICAL DEVICE INSTALLATION E-310 FEEDER SCHEDULE 2019.03.04 ISSUED FOR PERMIT 18. PROVIDE ALL WIRING DEVICES. TELEVISION OUTLET MOUNTED AT 18"AFF, UNO E-311 TELEPHONE, DATA AND TV RISER DIAGRAM 2019.03.04 ISSUED FOR PERMIT NOTE: ALL RECEPTACLES SHALL BE 18" A.F.F UNLESS 19. IDENTIFY CLEARLY ON A TYPE WRITTEN FORM ALL CIRCUITS AND EQUIPMENT TO CORRESPOND WITH THE i TELEPHONE OUTLET MOUNTED AT I8"AFF, UNO a NOTED OTHERWISE PLANS AND PANEL SCHEDULE AND ATTACH INSIDE THE PERTAINING PANEL. DATA OUTLET MOUNTED AT AFF, UNO 20. CONTRACTOR SHALL REFER NEC SECTION 310.15(B) FOR TYPE OF CABLE AND ASSOCIATED TEMPERATURE = COMBINATION DATAIPHONE OUTLET OU TLET MOUNTED AT 18" AFF, UNO RATING.ALL UNDERGROUND RACEWAYS TO BE PVC, INSIDE CONCRETE SLAB EMT WITH APPROVED SET WHERE TELEPHONE OR N SCREW FITTING, OR PVC, INSIDE PARTITIONS EMT OR ENT OR MC CABLE, IF ALLOWED BY LOCAL CODES. ® 2 GANG FLOOR BOX WITH DUPLEX RECEPTACLE AND N OUTLET. OUTLETS ARE INDICATED AT DRY LOCATION ROMEX OR BX CABLE WHERE MEET THE CONDITION AS SPECIFIED IN NEC 320 & 334. THE SAME LOCATION AS A ® 2 GANG FLOOR BOX WITH DUPLEX RECEPTACLE AND COMMUNICATION OUTLET. _ DUPLEX RECEPTACLE. THEY 21. CONTRACTOR SHALL FURNISH THE ENGINEERING WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO U U ARE TO BE IN A QUAD BOX PURCHASE FOR APPROVAL. El CARD READER MOUNTED AT 48" AFF, UNO - a u WITH DIVIDER � 22. THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIRECTED BYTHE ARCHITECTAND BY E34 CAMERA MOUNTED AT 80"AFF, UNO v ' AUTHORITIES HAVING JURISDICTION, FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ER ABBREVIATIONS ELECTRICAL POWER. THE ENTIRE INSTALLATION SHALL BE TESTED FOR SHORTS, GROUNDS AND OPEN _CIRCUITS, AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING $ 125V OR 277V AC SINGLE POLE 20 AMP SWITCH (ROCKER TYPE) MOUNTED CONDITION TO THE COMPLETE SATISFACTION OF THE ENGINEER.AT AT48"TFON 48"AFF ON CENTER, UNO. A AMP f C7a AFC AVAILABLE FAULT CURRENT 23. ALL EQUIPMENTS AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE NON -FUSED DISCONNECT SWITCH AIC AMPERES INTERRUPTING CAPACITY BY OWNER. FUSED DISCONNECT SWITCH AFF ABOVE FINISHED FLOOR LOOR FINISH FLOOR ,(�;�� WIRELESS ACCESS POINT ADA AMERICAN DISABILITIES ACT 24. AT COMPLETION OF JOB THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS -BUILT SET OF AT AMP TRIP TYPICAL SWITCH TYPICAL OUTLET TYPICAL LOCATIONS REPRODUCIBLE DRAWINGS SHOWING THE EXACT ELECTRICAL INSTALLATION, WRITTEN MAINTENANCE ATS AUTOMATIC SWITCH HEIGHT INSTRUCTIONS AND SCHEDULE OF ROUTINE MAINTENANCE AS WELL AS ANY OTHER CLOSE OUT ITEMS CONNECTIVITY PANEL AWG GAUGSFERE AMERICAN WIRE GAUGE REQUIRED BY THE CONTRACT DOCUMENTS. BRKR BREAKER NOTE: 25. BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR ELECTRICAL EQUIPMENT C CONDUIT OR CONDUCTOR AS APPLICABLE WITH ANY EXISTING CONDITIONS. CB CIRCUIT BREAKER ELECTRICAL PANEL BOARD ALL RECEPTACLES SHALL BE CKT CIRCUIT 181 UNLESS NOTED 26. ALL ELECTRICAL SWITCHES,CONTROLS,ETC. IN ALL AREAS ARE TO BE ATA.D.A. ACCESSIBILITY CODE = CEILING OTHERWISE WHERE SWITCHES ARE COMPLAINT HEIGHT. REFER TO GENERAL NOTE#2-L). CUE INDICATED AT THE SAME ELECTRICAL DISTRIBUTION PANEL BOARD OR SWITCHBOARD CO CPT CONDUIT ONLY CONTROL POWER TRANSFORMER LOCATION AS DUPLEX 27. CIRCUIT NUMBERS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. BALANCE LOADS AMONG ® RECEPTACLE, THEYARE TO PHASES IN NEW PANEL BOARDS TO WITHIN 10%OF EACH OTHER. DTTS DOUBLE THROW TRANSFER SWITCH BE IN A 3-GANG BOX 71 TRANSFORMER EC EMPTY CONDUIT WITH DIVIDER 28. FEEDER CONDUCTORS SHALL BE SIZED BY ENGINEER. EF EXHAUSTFAN MECHANICAL EQUIPMENT & FIXTURE ELEC ELECTRICAL/ELECTRIC K E 29. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 30 DAYSAFTERTHE DATE OFSYSTEM EM EMERGENCY ,j Q ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDEDTOTHE BUILDING FA FIREALARM w O ❑ W OWNER, INCLUDING: EXHAUST FAN, CEILING MOUNTED FACP FIRE ALARM CONTROL PANEL FAAP FIRE ALARM ANNUNCIATOR PANEL ❑ It NIGHTSTAND FLUOR FLUORESCENT o W IN Q OF B) FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. ® EXHAUST FAN, WALL MOUNTED G,GND GROUND _ 0 z w I NIGHTSTAND ❑ 30. CONSTRUCTION DOCUMENTS SHALL REQUIRE THATAN OPERATING MANUAL AND MAINTENANCE �O THERMOSTAT GEN GENERATOR Ne Q A MANUAL BE PROVIDED TO THE BUILDING OWNER. THE MANUALS SHALL INCLUDE, ATA MINIMUM, O GF,GFCI HH GROUND FAULT (CIRCUIT) INTERRUPTER HAND HOLE P-# PUMP J THE FOLLOWING: HID HIGH INTENSITY DISCHARGE - 11Li LL LL AT TELEPHONE LL HOA HAND/OFF/AUTO 1 ¢ OUTLETS AND QUAD 4 A) SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH HORSE POWER 0 0 �o RECEPTACLES USE PIECE OF EQUIPMENT REQUIRING MAINTENANCE. LEGENDS HP HWH HOT WATER HEATER y 3-GANG BOX y B) OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT IG ISOLATED GROUND FIRE ALARM DEVICES FINISH FLOOR REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. INCAN JB INCANDESCENT JUNCTION BOX TYPICAL G ESTROOM TY ICAL TVVINUML THERMOSTAT TYPICAL NIGHT TYPICAL LAVATORY TV OUTLETS SWITCH OUTLET STANDS COUNTER KW KILOWATT C) NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. KWH KILOWATT HOUR E319 FIRE SMOKE DAMPER, FBSD KVA KILOVOLT -AMPERE 3. CONTRACTOR SHALL: 31. ELECTRICAL OUTLETS OR BOXES LOCATED ON OPPOSITE SIDES OF RATED WALLS OR PARTITIONS SHALL LTG LIGHTING MEET ONE OF THE FOLLOWING CRITERIA: FACP FIRE ALARM CONTROL PANEL LTS LIGHTS A) OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS, ASSOCIATION DUES, ROYALTIES, AND TAXES OF WHATEVER MCB MAIN CIRCUIT BREAKER NATURE WHICH SHALL APPLY TO THE WORK. RF RADIO RESPONDER, SURFACE MOUNTED A) BOXES SHALL BE SURROUNDED ON 5 SIDES WITH FIRE RATED GYPSUM BOARD TO MCC MOTOR CONTROL CENTER B) PAY ALL INSPECTION FEES AS REQUIRED BY LAW OR ORDINANCE. MAINTAIN THE FIRE RATING OF THE WALL. MAGNETIC HOLD OPEN FOR DOOR. MDP MAIN DISTRIBUTION PANEL MH METAL HALIDE OR MANHOLES AS APPLICABLE C) HOLD THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, B) BACK OF BOXES SHALL BE WRAPPED IN FIRE RESISTANT PUTTY SIMILAR TO SPEC- FPAP FIRE ALARM ANNUNCIATOR PANEL MLO MAIN LUG ONLY RULES, OR ORDINANCES. SEAL FIRE RATED PUTTY PADS. N NEUTRAL WC I� WAY COMMUNICATION BOX NEC NATIONAL ELECTRICAL CODE D) PROVIDE MATERIALS THAT ARE NEW AND FREE OF DEFECTS AND ILL L LISTED FOR THE INTENDED APPLICATION. NF NON FUSED 32. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS FREE OF DUST AND DUST PRODUCING ACTIVITIES, NFPA NATIONAL FIRE PROTECTION ASSOCIATION E) TAKE MEASUREMENTS AND MAKE LAYOUTS AS REQUIRED FOR PROPER INSTALLATION AND COMPLETION OF JUST PRIOR TO FINAL INSPECTION FOR CERTIFICATE OF OCCUPANCY. FACP FIRE ALARM CONTROL PANEL NIL NIGHT LIGHT (UNSWITCHEO CKT.) WORK IF THE ELECTRICAL DRAWINGS ARE NOT TO BE SCALED, WHERE SPECIFIC DETAILS AND DIMENSIONS PB PULL BOX FOR ELECTRICAL WORK ARE NOT SHOWN IN DRAWINGS. 33. AT COMPLETION OF WORK, CONTRACTOR SHALL CLEAN UP AND REMOVE ALL DEBRIS AND MATERIALS PH PHASE NOT INSTALLED IN WORK, LEAVING PREMISES CLEAN. PNL PANEL F) INSPECT SITE FOR FIELD VERIFICATION OF ALL ASPECTS OF THE PROJECT PRIOR TO BIDDING. PVC POLYVINYL CHLORIDE 34. ALL BRANCH CIRCUIT SUPPLYING OUTLETS IN LIVING AREA, SLEEPING AREA AND DINNING AREA SHALL G) EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO FAIR POWER PROVIDE PROTECTION OF BRANCH CIRCUIT AS PER NEC 210.12 FOR HOTEL GUEST ROOM AND SUITES. RCPT RECEPTACLE H) BE REQUIRED TO FURNISH, INSTALL AND/OR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS RUNS RIGID GALVANIZED STEEL SHOWN ON ANY OF THE ARCHITECTURAL, PLUMBING, AIR CONDITIONING, SPRINKLER DRAWINGS WITHOUT 35. PROVIDE ALL NON LOCKING -TYPE, 125-VOLT, 15-AND 20 AMPERE RECEPTACLES LOCATED IN SF SUPPLY FAN ADDITIONAL EXPENSE TO THE OWNER. GUESTROOMS AND GUEST SUITES SHALL BE LISTED TAMPER -RESISTANT RECEPTACLES AS PER NEC 40612 SH SHIELDED SPD SURGE PROTECTIVE DEVICE 36. THE FRANCHISE BRAND STANDARDS DESIGN DOCUMENT SHALL BE CONSIDER AS AN INTEGRAL PART OF THE CONSTRUCTION DOCUMENTS. ALL CONTRACTORS SHALL ENSURE THEY OBTAIN, READ, AND SPOT SINGLE POLE, DOUBLE THROW 4. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS FAMILIARIZE THEMSELVES WITH THE BRAND STANDARD DOCUMENT BEFORE BIDDING AND ALSO SPST SINGLE POLE, SINGLE THROW AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS THROUGHOUT THE CONSTRUCTION STAGES. IF THERE ARE ANY DISCREPANCIES BETWEEN THE SRAIC SERIES RATED AMPERES INTERRUPTING CAPACITY CONTRACTOR SHALL REMOVE AND REPLACE AT HIS EXPENSE, ALL ELECTRICAL WORK WHICH MAY HAVE TO BE CONSTRUCTION DOCUMENTS AND THE FRANCHISE BRAND STANDARDS, THE CONTRACTOR SHALL SW SWITCH REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES ISSUE AN RFI TO THE AOR AND EOR. SWB STRUCTURED WIRING BOX 5. VERIFY SERVICES CHARACTERISTICS, LOCATION AND CONNECTION WITH TELEPHONE AND ELECTRICAL UTILITY TELE TELEPHONE COMPANIES. THEY SHALL PERFORM ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTILITY COMPANY 37. GUNFIRE VENDOR SHALL PERFORM RADIO FREQUENCY COVERAGE TESTING AND PROVIDE DISTRIBUTED STANDARDS AND REQUIREMENTS. ANTENNA SYSTEM(DAS) ACCORDINGLY TO COMPLY WITH IFC SECTION 510 AND LOCAL AHJ REQUIREMENT. TTB TELEPHONE TERMINAL BOARD TWC TWO WAY COMMUNICATION 6. PROVIDE ALL LABOR,MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ALL WORK NECESSARY FOR THE COMPLETE EXECUTION OF THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS. TCM THOUSAND CIRCULAR MILES UG UNDERGROUND 7. DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS, UNLESS SPECIFIC DIMENSIONS ARE SHOWN. THE STRUCTURAL, ARCHITECTURAL AND SITE UPS UNINTERPRETABLE POWER SUPPLY CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. IF THE LOCATION OF ELECTRICAL DEVICES ARE NOT SHOWN ON UON UNLESS OTHERWISE NOTED ARCHITECTURAL DRAWINGS, THE CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS V VOLT OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, OR W WATTS �o..� "=RE HEAD ROOM OR SPACES OR CONDITIONS APPEAR INADEQUATE, RELEASED FOR CONSTRUCTION ORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, WP WEATHERPROOF " .ATIONS IN LAYOUTAS NEEDED TO PREVENT CONFLICT WITH WORK WAP WIRELESS ACCESS POINT e 'ION OF WORK. WHERE DISCREPANCIES OCCUR, THE ARCHITECTURAL Subject is compliance with all regulations XFMR TRANSFORMER = OVER THE ELECTRICAL LIGHTING FOR LOCATION AND ORIENTATION of Slate and Local Codes City of Camel ((�� �vmlUllDnrJnD1�L iTAID a DATE: 07/22/19 AM BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 Www.base4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF 1 12 i ATE W y W F '0 ':YO I PNP 2 �gBrONAL Iris` DATE: 20190304 GARRY VERMMS. PhD. HE Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOMEN, SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 E0 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO 64-134-1705 SHEET NAME GENERAL NOTES, LEGENDS AND ABBREVIATIONS DRAWINGS NO. E=001