E-102 - ELECTRICAL DETAILS-2
1 CI ATTACH FULLY -CHARGED BATTERY CONTROL BOX --- 0 1/2" X 1-12" HEX BOLT (4) 012" FLAT WASHER (4)- I ANCHORS (4)- INSTALLED y� FLUSH W/DECKJ ` POOL LIFT DETAILS NOT TO SCALE NOTES: 1. VERIFY NAMEPLATE RATINGS, LOCATIONS AND POINT OF POWER CONNECTIONS PRIOR TO ROUGH -IN. 2.DO NOT LOCATE DISCONNECT SWITCHES OVER UNIT ACCESS PANELS. 3.PROVIDE A 3/4' EMPTY CONDUIT THROUGH INACCESSIBLE LOCATIONS (I.E. WALLS, UNDER SLAB) 4. EQUIPMENT REQUIREMENTS ARE FOR MANUFACTURER AND MODEL NUMBER LISTED ON MECHANICAL PLANS. THE MECHANICAL CONTRACTOR SHALL BEAR ANY ADDITIONAL COSTS INCURRED IF ALTERNATE EQUIPMENT IS USED. 5.ALL MOTOR STARTERS AND/OR COMBINATION STARTERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. 6.#@ REPRESENTS THE TYPICAL WIRE SIZE AND TO VERIFY WIRE SIZE PER MANUFACTURER'S NAMEPLATE. 7. @,@ REPRESENTS THE TYPICAL PANEL AND CIRCUIT PER PIECE OF EQUIPMENT. 8 CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS WHERE AVAILABLE FAULT CURRENT AT EQUIPMENT IS ABOVE 5KA AMPS. - POOL WALL 2P/3R @/2P F CU #@AWG T#g " 2PF G TYPICAL TRANSFORMER SIZE ISOLATION 30,3Wr PRIMARY GROUND PER NEC 30,4W,,Y SECONDARY TABLE 250-122. SIZE GROUND PER L- SIZE GROUND PER NEC TABLE 250-122. J NEC TABLE 250-66. FURNISH AND INSTALL A COPPER EQUIPMENT GROUND BAR KIT WITH INDIVIDUAL TERMINALS FOR EACH GROUNDING CONDUCTOR. SECURELY MOUNT IN ACCESSIBLE SPACE AT TRANSFORMER TERMINAL COMPARTMENT. SIZE GROUND BAR KIT TO ACCOMMODATE MAXIMUM AND MINIMUM GROUND CONDUCTOR SIZES FOR EACH GROUND TERMINAL. BOND TO ELECTRICAL ROOM GROUND BAR (IF NEAR BY) OR TO BUILDING STEEL AND COLD WATER PIPE (2-MIN). VERIFY CONTINUITY OF _ COLD WATER PIPE. SIZE GROUND PER NEC TABLE 2501,66. DRY TYPE SHIELDED ISOLATION 2TRANSFORMER WIRING DETAIL NOT TO SCALE TYPICAL BRANCH CIRCUIT WITH GROUND CONDUCTOR (IF REQUIRED). TYPICAL30,4W PANEL WITH ISOLATION GROUND BUS PANEL MPZLA 0 208Y/120V,3P,4W FED FROM 1HA NOTES: 1. TAGS TO BE MELAMINE PLASTIC LAMINATE IN SIZES AND THICKNESSES INDICATED. TAG THICKNESS TO BE 1/16' FOR UNITS UP TO 20 SQUARE INCHES OR 8' IN LENGTH AND III FOR LARGER TAGS. 2. SECURE TAGS TO EQUIPMENT WITH SELF -TAPPING STAINLESS STEEL SCREWS, EXCEPT CONTACT TYPE PERMANENT COMMERCIAL GRADE ADHESIVE PROVIDING A PERMANENT BOND SHALL BE USED WHERE SCREWS CANNOT OR SHOULD NOT PENETRATE SUBSTRATE. 3. COLOR CODES: (a) NORMAL SYSTEM: WHITE LETTERING IN A BLACK FIELD (b) EMERGENCY SYSTEM: WHITE LETTERING IN A YELLOW FIELD (c) FIRE ALARM SYSTEM: WHITE LETTERING IN A RED FIELD 4. REFER TO SPECIFICATION SECTION 16020 FOR FURTHER INFORMATION. WIRING DIAGRAM - HVAC SPLIT SYSTEM. 5 PANEL IDENTIFICATION DETAIL NOT TO SCALE NOT TO SCALE NOTES: 1. BACK-TO-BACK AND THRU-WALL OUTLETS ARE NOT PERMITTED. GUESTROOM POWER OUTLETS, TELEPHONE OUTLETS, TELEVISION OUTLETS, HVAC JUNCTION BOXES, ETC. MUST BE OFFSET. THIS IS TO MAINTAIN THE FIRE RATING OF THE WALL AND TO PREVENT SOUND TRANSMISSION THROUGH THE OUTLETS. IN CONCRETE BLOCK WALLS OFFSET OUTLETS 6' BY LOCATING IN SEPARATE BLOCK CELLS. IN METAL STUD WALLS AND WOOD STUD WALLS, PROVIDE AT LEAST 6' CLEAR HORIZONTAL SPACE BETWEEN BOXES. LOCATE IN SEPARATE STUD SPACES IF POSSIBLE, BUT DO NOT MOUNT ON THE OPPOSITE SIDES OF THE SAME STUD. ;1aIZIMA1]111;1M11;ti'1MIA ItlE Subject to compliance Bgh all regulations of State and Local Codes City of Camel ((�� `�vmlUtlDnrJnD�L x DATE: 07/22/19 TLET DETAIL 19 u TRANSFORMER GROUNDING DETAIL NOT TO SCALE 0 0 0 0 0 0 0 0 0 0 0 0 M 0 0 0 0 0 D GROUND BAR. COORDINATE -LOCATION SUCH THAT LEAD LENGTH DOES NOT EXCEED 18'. INTERNALLY MOUNTED SURGE PROTECTIVE DEVICE (SPD) CLOSE NIPPLE 5#10,314'C MINIMIZE LEAD LENGTHS AND BENDS NEUTRAL BAR. COORDINATE LOCATION SUCH THAT LEAD LENGTH DOES NOT EXCEED 18'. NOTES: 1. IN ALL CASES, THE SPD SHALL BE LOCATED IMMEDIATELY ADJACENT TO THE SWITCHBOARD OR POWER DISTRIBUTION PANELBOARD BEING PROTECTED.SPD CAN BE MOUNTED TO THE SIDE OR TOP OF THE SWITCHBOARD OR POWER DISTRIBUTION PANELBOARD. 2. IN ALL CASES, THE SPD SHALL BE LOCATED IMMEDIATELY ADJACENT TO ITS DISCONNECTING CIRCUIT BREAKER. 3. IN NO CASE SHALL THE LEAD LENGTHS OF THE SPD EXCEED 18'. IF THIS LENGTH IS EXCEEDED THROUGH NECESSITY, THE CONTRACTOR MUST CONTACT THE MANUFACTURER FOR INSTALLATION ASSISTANCE. 4. REFER TO SPECIFICATION SECTION 16610 FOR FURTHER INSTALLATION REQUIREMENTS. 3 SWITCHBOARD TVSS INSTALLATION DETAIL NOT TO SCALE MAXIMUM 3mm (1/8') CLEARANCE BETWEEN BOX AND THE WALL BOARD FRONT FACE OF (TYPICAL) 1 OR 2 HOUR FIRE WALL RECESMAXIMUMDEPTH F RATED GYPSUM FROM FACE OF H BOX WALL BOARD FROM FACE OF THE WALL I STEEL OR WOOD WALLSTUD- METALLIC BOX NOTES: 1. WALL OPENING PROTECTION SYSTEM FOR 4'x4' MAXIMUM SIZE OUTLET BOXES MOUNTED: 2. ON OPPOSITE SIDES OF A WALL LESS THAN 24' APART, OR WHERE MORE THAN FIVE (5) OUTLET BOXES ARE INSTALLED PER 100 SQUARE FEET OF A WALL SURFACE ON THE SAME SIDE. BOXES SHALL NOT BE INSTALLED BACK TO BACK. 3. DETAIL FOR USE WITH METALLIC OUTLET BOXES ONLYA OR 2 HOUR RATING. 6 WALL OPENING PROTECTION NOT TO SCALE OND U IT OR CABLE 3M FIRE BARRIER MOLDABLE PUTTY \-CONDUIT OR CABLE MAXIMUM III CLEARANCE BETWEEN BOX AND THE WALLBOARD (TYPICAL) - 1 OR 2 HOUR FIRE RATED GYPSUM WALL CONDUIT OR CABLE- 0 O O Q Q METALLIC O OUTLET BOX 3M FIRE BARRIER MOLDABLE PUTTY MAXIMUM III STEEL OR WOOD RECESS DEPTH OF WALL STUD BOX FROM FACE OF THE WALL NOTES: 1.TOP OF GROUND WIRE AND ROD SHALL BE 6' BELOW GRADE. 2.THIS STANDARD PAD GROUNDING INSTALLATION METHOD SHALL BE USED WHEN DIFFERENT PARTIES ARE RESPONSIBLE FOR THE CONDUIT AND PAD INSTALLATION. NOTES. 1. BARE COPPER GROUNDING WIRE, #2AWG, 7-STRAND SOFT DRAWN. 2. RUN SECOND TAIL AROUND GROUND ROD BUT NOT THRU CLAMP. 3. SDGSE FURNISHED AND INSTALLED COMPRESSION CONNECTOR. 4.24' LENGTH OF TAILOUT BEYOND PAD. 5.PAD INSTALLATION BY ELECTRICAL CONTRACTOR PER SDGBE REQUIREMENTS. &GROUND ROD 5/8' X 8'1 COPPER W ELD. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 wWw.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF QP��'\si EHh� e' %p m N 12 o ATE DATE: 20190304 01 VERMAAS. PhD. PE Owner: 1� �I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY III TOM CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 EO 2019.03.04 ISSUED FOR PERMIT CURRENTISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO, 134-134-1705 SHEET NAME ELECTRICAL DETAILS-2 DRAWINGS NO. E-102