Loading...
HomeMy WebLinkAboutE-104 - ELECTRICAL DETAILS-4CI z0 5z �n mU z o z �a �o a; oz w� FENCE, PROPERTY LINE, BUILDING SCREEN WALL OR LANDSCAPING z0 �a -W ono zz KO rc3 mz ui w wo FENCE, PROPERTY LINE, BUILDING SCREEN WALL OR LANDSCAPING BETWEEN CONDUITS ?EDGES KVA 1 A 1 B 1 C 1 D 1 E 1 F 1 G 1 H 1 I 1 J 45-500 1 76176 1 6 1 8 1 34 126 1 8 142 1 26 1 8 750-1000 1 90190 1 8 115 1 34 126 1 15 154 1 26 1 10 1500-2500 1 10411041 8 122 1 34 126 1 22 168 1 26 1 10 NOTES: 1. CONCRETE SPECIFICATIONS, MIN 28 DAY COMPRESSIVE STRENGTH 3000PSI,3r4" AGGREGATE MAXIMUM SIZE. 2. REINFORCING STEEL, ASTM -A615 GRADE 60, PLACE 6" O.C. EACH WAY AND SECURELY TIED TOGETHER. 3. MINIMUM CONCRETE COVER OVER REINFORCING RODS, 3". 4. WOOD FLOAT FINISH, LEAVING NO DEPRESSIONS. 5. PRIMARY & SECONDARY CONDUITS TO BE SEPARATED BYAT LEAST 6". RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel ((�� �vmlUtlenrJnIX1�L x DATE: 07/22/19 NSTALLATION DETAILS 1. WALL ASSEMBLY: - THE 1 OR 2 HR FIRE RATED FRAMED GYPSUM BOARD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300, U400, V400, OR W400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A.STUDS :- WALL FRAMING SHALL CONSIST OF STEEL CHANNEL STUDS OR WOOD STUDS. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE AND SPACED MAX 24 IN. (610 MM) OC. WOOD STUDS TO BE MIN 2 BY 4 IN. (51 BY 102 MM) OR LARGER AND SPACED MAX 16 IN. (406 MM) OC. AN ADDITIONAL FRAMING MEMBER SHALL BE USE TO FORM A SHELF WITHIN THE WALL CAVITY TO SUPPORT THE STEEL BOX (ITEM 2) AND MAT FILL MATERIAL (ITEM 3). THE FRAMED OPENING IS TO BE 1 IN. (25 MM) WIDER THAN THE WIDTH OF THE STEEL BOX. B. GYPSUM BOARD,. - THE GYPSUM BOARD TYPE, THICKNESS, NUMBER OF LAYERS AND ORIENTATION SHALL BE, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. SIZE OF CUTOUT MADE TO ACCOMMODATE STEEL BOX (ITEM 2) IS TO BE 1 IN. (25 MM) WIDER AND 1 IN. (25 MM) HIGHER THAN THE WIDTH AND HEIGHT OF THE STEEL BOX. THE HOURLY F, T, FT, FH AND FTH RATINGS OF THE FIRE STOP SYSTEM -ARE EQUAL TO THE HOURLY FIRE RATING OF THE WALL IN WHICH THE FIRE STOP SYSTEM IS INSTALLED. 2. STEEL BOX: - MAX 19 IN. (483 MM) WIDE BY MAX 32 IN. (813 MM) HIGH BY MAX 31/2 IN. (89 MM) DEEP FOR STEEL STUD WALLS. MAX 12 IN. (305 MM) WIDE BY MAX 32 IN. (813 MM) HIGH BY MAX 31/2 IN. (89 MM) DEEP FOR WOOD STUD WALLS. BOX TO BE RECESSED BOX WITH HINGED STEEL DOOR AND MOUNTING FLANGE. STEEL BOX SECURED TO STEEL STUDS WITH STEEL SCREWS AFTER APPLICATION OF MAT MATERIAL (ITEM 3) ON EXTERIOR SURFACES OF STEEL BOX. BOTTOM AND/OR TOP OF STEEL BOX MAY BE PENETRATED BY UP TO TWO MAX 1-1/2 IN. (38 MM) DAM COPPER, STEEL OR IRON PIPES OR TUBES. OPEN PIPES OR TUBES WHICH TERMINATE WITHIN THE BOX SHALL BE SEALED WITH CAULK (ITEM 4) OR PLUGGED WITH A BALL OF PUTTY (ITEM 5). 3. FILL, VOID OR CAVITY MATERIALS' - MAT: - NOMINAL 0.4 IN. (10 MM) THICK ALUMINUM FOIL FACED ENDOTHERMIC MAT SUPPLIED IN 24 IN. WIDE ROLLS. INDIVIDUAL PIECES OF MAT CUT TO COVER FOUR SIDES AND BACK OF BOX AND LAMINATED TO BOX WITH HIGH STRENGTH, FAST, CONTACT TYPE ADHESIVE (FOIL FACE EXPOSED). THE MAT SECTIONS ON THE TOP AND BOTTOM OF THE BOX SHALL BE CUT TO OVERLAP THE MAT SECTIONS ON THE SIDES OF THE BOX. THE MAT SECTION ON THE BACK OF THE BOX SHALL BE CUT TO LAP OVER THE EDGE OF THE MAT SECTIONS ON THE TOP, BOTTOM AND VERTICAL SIDES OF BOX. CIRCULAR CUTOUTS MADE IN THE MAT TO ACCOMMODATE THE PIPES OR TUBES TO BE 1/4 IN. TO 1/2 IN. (6 TO 13 MM) LARGER THAN OUTSIDE DAM OF PIPE OR TUBE. ALL CORNERS AND BUTTED SEAMS IN THE MAT ARE TO BE COVERED WITH MIN 2 MIL ALUMINUM FOIL TAPE. 3M COMPANY 3M FIRE PROTECTION PRODUCTS —TYPE E-54A OR E-5A-4 MAT 4. FILL, VOID OR CAVITY MATERIALS' - CAULK OR SEALANT: - (NOT SHOWN) - NOM 114 IN. (6 MM) DAM BEAD OF CAULK APPLIED TO THE EDGE OF THE MAT MATERIAL AROUND THE PERIMETER OF THE BOX MOUNTING FLANGE. ADDITIONAL CAULK FILL MATERIAL SHALL BE USED TO COMPLETELY FILL EACH CIRCULAR CUTOUT MADE IN THE MAT MATERIAL TO ACCOMMODATE A PIPE OR TUBE. THE END OF EACH OPEN PIPE OR TUBE WHICH TERMINATES WITHIN THE BOX SHALL BE SEALED WITH A MIN 1/2 IN. (13 MM) DEPTH OF CAULK. 3M COMPANY 3M FIRE PROTECTION PRODUCTS —TYPE CP 25WB+CAULK, FB-3000WT SEALANT 5. FILL, VOID OR CAVITY MATERIALS' - PUTTY: - (NOT SHOWN) -AS AN ALTERNATE TO THE CAULK (ITEM 4), THE END OF EACH OPEN PIPE OR TUBE WHICH TERMINATES WITHIN THE BOX MAY BE SEALED WITH A MIN 1/2 IN. 13 MM) DEPTH OF PUTTY FILL MATERIAL. 3M COMPANY 3M FIRE PROTECTION PRODUCTS —TYPE MP+MOLD-ABLE PUTTY FLUSH MOUNTED PANEL BOARD DETAIL NOT TO SCALE SECTION A -A BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF QP��'\si EHh� O' %p m N 1 12 o ATE 9D . 01I PNP:'2b �g&f.NAL DATE: 20190304 GAMY VE]VIII PhD. PE Owner: t� �1 1� �I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 EO 2019.03.04 ISSUED FOR PERMIT CURRENTISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO, 64-134-1705 SHEET NAME ELECTRICAL DETAILS-4 DRAWINGS NO. E-104