Loading...
HomeMy WebLinkAboutE-202 - 2ND FLOOR POWER PLAN1 2 3 3.1 4 T TT T III I I I 3 E E-210 -210 K ItIt IT '` D O I O o 1 0 --8 1THiNiD ACC. D D D D gg ONE o QUEEN/ IRDS20M QUEEN/ QUEEN QUEEN/ QUEEN/ QUEEN STUDIO KING QUEEN QUEEN QUEEN/ STUDIO CONNECTING. KING KING KING STUDI0203 STUDI0205 STUDI020] QUEEN CONNECTING 213 STUDIO STUDIO STUDIO 2GA: 1,3 2 2GA:911 STUD10209 211 yG8:1.3 2GB:S,7 2GB:9,11 G13:13,15 � GA: 1315 ® ,� _JII NN NN �iffW 7 N��1 e� 11 .w .. Li. . L_ _ III --I 1 I ■ _ 1.: ■ ■ .n ■I �= rua�=�I■ Ic�ar����l= I�r_���d� ■I= Irua '��r�i�-j -■ �—II�LJI�II I■ �j wiw j��—I■ ■j Moll: u I I IN 7�I I u� 7�I u� ail � � � ,I■, ��-��. TUDIO KING lIJ DO NECTING STUDIO KING KING KING KING -v�2GA 25 �I 30 li - I JCi� �2NDFLOOR POWER PLAN POWER PLAN 1/8" = 1'-011 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Caved AUTG,U `/�f N DATE: 07/22/19 16 17 18 100 19 20 21 I I I I E-210 I I I I o I I I KING ONE BEDROOM 221 2GB: 1],19 O OF STORAGE 231 2GA: 29 I I I I I 4 '%i CORR. 200 10 GA: 26 I i1111 9 9 9 MILD 9 313:: 21.4 1 PNLG I PNLG' PNLD' \CK 2GB: 6,11 8: 10,12 2GB: 14,16 213B: 18,20 KING KING I KING I KING KING STAIR#1 STUDIO 216 STUDIO 218 STUDIO 220 STUDIO 222 STUDI0224 I I I I I I I I I I II II E-202 KEY NOTES ® Text 1 PROVIDE HOUSE PHONE. 2 PROVIDE TWO WAY COMMUNICATION SYSTEM AT ELEVATOR LANDING ON EACH ACCESSIBLE FLOOR THAT IS ONE OR MORE STORIES ABOVE OR BELOW THE STORY OF EXIT DISCHARGE. COMPLY WITH IBC SECTION 1009.8.1 AND 1009.8.2. AS PER IBC SECTION 1009.08.1 TWO WAY COMMUNICATION SYSTEM SHALL PROVIDE COMMUNICATION BETWEEN EACH REQUIRED LOCATION AN D THE FIRE COMMAND CENTER OR A INTERNAL CONTROL POINT LOCATION APPROVED BY THE FIRE DEPARTMENT. WHERE THE CENTRAL CONTROL POINT IS NOT CONSTANTLY ATTENDED A TWO WAY COMMUNICATION SYSTEM SHALL HAVE A TIMED AUTOMATIC TELEPHONE DIAL OUT CAPABILITY TO A MONITORING LOCATION OR 911. THE TWO WAY COMMUNICATION SYSTEM SHALL INCLUDE BOTH AUDIBLE AND VISIBLE SIGNALS. AS PER IBC SECTION 1009.8.2 DIRECTION FOR THE USE OF TWO WAY COMMUNICATION SYSTEM INSTRUCTION FOR SUMMONING ASSISTANCE VIA THE TWO WAY COMMUNICATION SYSTEM AND WRITTEN IDENTIFICATION OF THE LOCATION SHALL BE POSTED ADJACENT TO THE TWO WAY COMMUNICATION SYSTEM. CONTRACTORSHALLALSOVERIFYTWOWAY COMMUNICATION AS PER IBC SECTION 3008.6.6. 3 J-BOX FOR LAUNDRY CHUTE DOOR INTERLOCK TYPICAL FOR EACH FLOOR INTO CIRCUIT. 4 CONTRACTOR TO ENSURE WI-FI IS PROVIDED THROUGHOUT PUBLICAREA. 5 FIRE VENDOR SHALL PROVIDE RADIO RESPONDER OF APPROVED RADIO COVERAGE FOR EMERGENCY RESPONDERS WITHIN THE BUILDING BASED UPON THE EXISTING COVERAGE LEVELS OF THE PUBLIC SAFETY COMMUNICATION SYSTEMS OF THE JURISDICTION AT THE EXTERIOR OF THE BUILDING. 6 CONTRACTOR SHALL PROVIDE POWER AND COORDINATE WITH LV VENDOR FOR CONNECTION. 7 AS PER NEC 210.8 PROVIDE GFCI RECEPTACLE AT READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI PROTECTION IN BREAKER FOR CIRCUIT. 8 CONTRACTOR SHALL PROVIDE BATTERY PACK CARD READER TYPICAL FOR ALL FLOORS. 9 GUEST ROOM PANEL BOARD SHALL BE FLUSH MOUNTED ON WALL AND MAINTAIN MIN. 1HR FIRE RESISTANCE RATING OF THE WALL. CONTRACTOR SHALL MAINTAIN MIN CLEAR SPACE REQUIRED AS PER NEC ARTICLE 110.26. 10 FIRE/SMOKE DAMPER CONNECT TO FIRE ALARM SYSTEM. SEE MECHANICAL DRAWING FOR LOCATION AND EQUIPMENT. PROVIDE ELECTRICAL CONNECTION TO FIRE/SMOKE DAMPER FROM EM40 PANEL. 11 CONTRACTOR TO ENSURE A MINIMUM CLEARANCE BETWEEN ELECTRICAL AND LV CONDUIT. BAS E'' BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base4.ccm RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QP��'\si EHh� O' %p m Nac 12 o ATE 90 . 01I PNP:'2b �gBrONAI E�` DATE: 201803 W GARRY VERMAAS. Phi HE Owner: illAM ,1 1 �� rAW ��IVA THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 EO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO. 134-134-1705 SHEET NAME 2ND FLOOR POWER PLAN DRAWINGS NO. E=202