Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E-203 - 3RD FLOOR POWER PLAN
1 2 3 3.1 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 100 19 20 21 I I I I I I I I I I I I I I I I I I I I I I I 4 E210 I I I I ACC. ° ° ° ° QUEEN/ G — — — — — — — — — QUEEN/ _ — — — — — — _ QUEEN/ QUEEN/ QUEEN/ QUEEN STUD0 STUD O KING ONE — KING KING KING QUEEN QUEEN QUEEN STUDIO CONNECTI CONNECTING BEDROOM STAIR#2 STUDI0303 CONNECTING STUDI0315 STUDq 317 CONNECTING F 38 +I STUDI0305 STUDI0307 STUDI0309 -31— 313 319 II'CCCUSTOM ING ONE OO B° -. SEA: 1,3 EDROOM NL'C' 301 3 A.57 3GA: 9,11 3 A: 13,15 SEA: 17, 9 A; 21,23 3GB: B: '�,7 3GB: 9, 1113GS: 13.15 I PNL'E' 3GB: 17,19 NL'D' PN PI PNL'H' PNL'H' PNL'F' N D' PNL'D' PNL'D' O O 9 9 9 9 9 9 9 TRIP Im O O O O Q, #NUC' 9 1-011 AW 331 SIG:29 10 4 IDF/I CORR. 300 10 CORR. 00 4 4 CORR. 300 ELE 8P9 CAL 4 GA: 26 s 7 8 4NL' O OQ , ELEV# 719 99P L'D' PNL' L'D' PNL'D' KA 1ELEVATOR3GA: 6,8 3 A: 10,12 3GA: 14, 6 3GA: 18,20 3GA: 22, LOBBV327(DcSTKINGt STUDIOKINGC NNECTING STUDIO KING KING KING KING GA: 25302 CONNECTING STU010306 STU010306 STU010310 STU010312 1 All ° — — — — — — ° HP 8 1 1 1 HOUSEP3EEPING 30 A.1 � — � — _ — — — — — 3GA: 28 I I I I I I I I I I I I I I n 3RD FLOOR POWER PLAN 1/8 11 = 11.011 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� �vm�JllBnrklDAaL x DATE: 07/22/19 RACK 3GB:8,8 3GB:10,12 3GB: 14,16 3GB: 18,20 30-)) KING KING KING KING KING ST 38R0#1 STUD10316 STUDIO 318 STUDI0320 STUDIO 322 STUDIO 324 I I I I I I I I I I I I I E-203 KEY NOTES ® Text 1 PROVIDE HOUSE PHONE. 2 PROVIDE TWO WAY COMMUNICATION SYSTEM AT ELEVATOR LANDING ON EACH ACCESSIBLE FLOOR THAT IS ONE OR MORE STORIES ABOVE OR BELOW THE STORY OF EXIT DISCHARGE. COMPLY WITH IBC SECTION 10093A AND 1009.8.2. AS PER IBC SECTION 1009.08.1 TWO WAY COMMUNICATION SYSTEM SHALL PROVIDE COMMUNICATION BETWEEN EACH REQUIRED LOCATION AND THE FIRE COMMAND CENTER OR A INTERNAL CONTROL POINT LOCATION APPROVED BY THE FIRE DEPARTMENT. WHERE THE CENTRAL CONTROL POINT IS NOT CONSTANTLY ATTENDED A TWO WAY COMMUNICATION SYSTEM SHALL HAVE A TIMED AUTOMATIC TELEPHONE DIAL OUT CAPABILITY TO A MONITORING LOCATION OR 911. THE TWO WAY COMMUNICATION SYSTEM SHALL INCLUDE BOTH AUDIBLE AND VISIBLE SIGNALS. AS PER IBC SECTION 1009.8.2 DIRECTION FOR THE USE OF TWO WAY COMMUNICATION SYSTEM INSTRUCTION FOR SUMMONING ASSISTANCE VIA THE TWO WAY COMMUNICATION SYSTEM AND WRITTEN IDENTIFICATION OF THE LOCATION SHALL BE POSTED ADJACENT TO THE TWO WAY COMMUNICATION SYSTEM. CONTRACTOR SHALL ALSO VERIFY TWO WAY COMMUNICATION AS PER IBC SECTION 3008.6.6. 3 J BOX FOR LAUNDRY CHUTE DOOR INTERLOCK TYPICAL FOR EACH FLOOR INTO CIRCUIT. 4 CONTRACTOR TO ENSURE WIFI IS PROVIDED THROUGHOUT PUBLIC AREA. 5 FIRE VENDOR SHALL PROVIDE RADIO RESPONDER OF APPROVED RADIO COVERAGE FOR EMERGENCY RESPONDERS WITHIN THE BUILDING BASED UPON THE EXISTING COVERAGE LEVELS OF THE PUBLIC SAFETY COMMUNICATION SYSTEMS OF THE JURISDICTION AT THE EXTERIOR OF THE BUILDING. 6 CONTRACTOR SHALL PROVIDE POWER AND COORDINATE WITH LV VENDOR FOR CONNECTION. 7 AS PER NEC 210.8 PROVIDE GFCI RECEPTACLE AT READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI PROTECTION IN BREAKER FOR CIRCUIT. 8 CONTRACTOR SHALL PROVIDE BATTERY PACK CARD READER TYPICAL FOR ALL FLOORS. 9 GUEST ROOM PANEL BOARD SHALL BE FLUSH MOUNTED ON WALL AND MAINTAIN MIN. 1HR FIRE RESISTANCE RATING OF THE WALL. CONTRACTOR SHALL MAINTAIN MIN CLEAR SPACE REQUIRED AS PER NEC ARTICLE 110.26. 10 FIRE/SMOKE DAMPER CONNECT TO FIRE ALARM SYSTEM. SEE MECHANICAL DRAWING FOR LOCATION AND EQUIPMENT. PROVIDE ELECTRICAL CONNECTION TO FIRE/SMOKE DAMPER FROM EM40 PANEL. 11 CONTRACTOR TO ENSURE A MINIMUM CLEARANCE BETWEEN ELECTRICAL AND LV CONDUIT. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.com RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QP��\si Or. o.m Oc.x N 1 12 o AE a OF �geronu,L eN° DATE: 2°1e.°3.°4 GARRY VERMMS. Phi PE Owner: AI ZZ, I t� THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTOK CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO. DELTA I ISSUED DATE DESCRIPTION 1 E0 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO. B4-134-1705 SHEET NAME 3RD FLOOR POWER PLAN DRAWINGS NO. E=203