E-209 - TYPICAL UNIT ELECTRICAL POWER PLAN-1
I T1VF1. `LR1jOp GENERAL NOTES: 1. REFER TO ARCHITECTURAL/ID DRAWINGS FOR EXACT DIMENSIONS AND HEIGHT. 2. REFER TO SHEET E-301 THROUGH E-310 FOR PANEL SCHEDULE, RISER DIAGRAM AND BRANCH CIRCUIT INFORMATION. 3'-0"AFF 15 3. ALL RECEPTACLES USED IN GUEST ROOM SHOULD BE FID NEMA 5-20R DUPLEX RECEPTACLE, UON. SWITCH FOR MOTORISED FOR REFRIGERATOR SHADEAT3'-6"AFF -6"AFF 4. PROVIDE ALL NON LOCKING-TYPE,125-VOLT,15-AND 20 AMPERE CKT:9,11 CKT:10,1 `J CKT. FOR MICROWAVE RECEPTACLES LOCATED IN GUESTROOMS AND GUEST SUITES 13I 1 @3'-4"AFF SHALL BE LISTED TAMPER -RESISTANT RECEPTACLES AS PER NEC V 7 7 7 C :3 406.12. T AFF 2 ON 5. CONTRACTOR SHALL CO-ORDINATE INSTALLATION OFWIRELESS VI K3 8 COMMUNICATION SYSTEM THROUGHOUT THE BUILDING. 4 ° OR UTILITY ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND ® CKT:1 @3'-4"AFF JUNCTION BOXES FOR WAP INSTALLATION. 5 12 1'-5"AFF 1' FF 11 SWITCH FOR GARBAGE 3'4"AFF 12 CKT: DISPOSAL @3'-4"AFF 6. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING WITH THE 4 CKT.7 AUTHORITY HAVING JURISDICTION, THAT THE RECEPTACLES Z 12 ® Z n FOR DISHWASHER LAYOUT MEETS THE REQUIREMENTS OF 210.52 AND LOCAL %, 14 CKT: @i'-0"AFF REQUIREMENTS. 12 _ 1 J-BOX FOR GARBAGE 7. AS PER NEC ARTICLE 210.8 GFCI PROTECTION REQUIRED FOR ALL © — 1'-0"AFF� T DIPOSAL @1'-0"AFF RECEPTACLES THAT SERVE KITCHEN COUNTERTOP SURFACES IN C .1 DWELLING UNIT.GFCI PROTECTION IS REQUIRED FOR ' j RECEPTACLES SERVING APPLIANCES LIKE DISHWASHERS ,OR CONVENIENCE RECEPTACLES INSTALLED WITHIN 6FTOF THE ACC. KING OUTSIDE EDGE OF A W ET BAR SINK. GFCI RECEPTACLE SHALL BE ONE I / AT READILY ACCESSIBLE LOCATION IF NOT PROVIDE GFCI BEDROOM BREAKER IN PANEL FOR DUPLEX RCPT. R.I.S 201 S. BACK-TO-BACK AND THRU-WALL OUTLETS ARE NOT PERMITTED. 1'-6"AFF ACC. KING GUESTROOM POWER OUTLETS, TELEPHONE OUTLETS, STU DID TELEVISION OUTLETS, HVAC JUNCTION BOXES, ETC. MUST BE - 0'AFF �- CONNECTING 12 3'-0"AFF OFFSET. THIS IS TO MAINTAIN THE FIRE RATING OF THE WALL J-BOX FOR GARBAGE 10 11 9 r 1'-0"AFF 1'-FAFF 202 AND TO PREVENT SOUND TRANSMISSION THROUGHTHE DISPOSAL@1'-0"AFF CKT: T PNL'A' OUTLETS. IN CONCRETE BLOCK WALLS OFFSET OUTLETS 6" BY C - 14 - CKT:1 LOCATING IN SEPARATE BLOCK CELLS. IN METAL STUD WALLS K ,12 AND WOOD STUD WALLS,PROVIDE AT LEAST 6" CLEAR SWITCH] FOR GARBAGE HORIZONTAL SPACE BETWEEN BOXES. LOCATE IN SEPARATE DISPOSAL @3'-0"AFF O STUD SPACES IF POSSIBLE, BUT DO NOT MOUNT ON THE OPPOSITE SIDES OF THE SAME STUD. FOR UTILITY 12 @3'-0"AFF 8 - u E-209 KEY NOTES FOR DISHWASHER 3 12 o @ ,- . 1 OAFF I � OKT.3 ® Text FOR MICROWAVE 1 I 5 @3'-0"AFF T.4 T AFF 1'-7"AFF 1 ALL GFCI RECEPTACLES AND SWITCHES IN GUEST BATHROOMS SHALL BE MOUNTED 40" TO CENTER A.F.F. PROVIDE GFCI FOR REFRIGERATOR RECEPTACLE IN GUEST BATHROOM. @i'-0"AFF 191 1'-WAFF �-uy gCKT:2 2 WHEN AN OPTIONAL WIRED CONNECTION FOR GUEST IS ALSO PROVIDED, ANOTHER CAT6-RJ45 CABLE TERMINATED ON AN B-PIN RJ45 FEMALE JACK MUST BE PROVIDED ON THE WALL 7 7 -_ -- BELOW THE DESKNVORKAREA. MAINTAIN 6" CLEARANCE FROM 13 ALL OTHER OUTLETS AND DEVICES. A PATCH CORD SHOULD BE PROVIDED AT THE DESKTOP FOR GUEST CONVENIENCE. SWITCH FOR MOTORISED 3 PROVIDE (1) CAT6-RJ45 CABLE IN EVERY GUESTROOM ON THE WALL BELOW THE DESK/W ORK AREA TERMINATED ON AN 8-PIN SHADE AT 3'-6"AFF RJ45 FEMALE JACK FOR WIRELESS ACCESS POINT J-BOX FOR MOTORIZED INFRASTRUCTURE (LINE POWERED WAP). ROLLER SHADE 4 CONTRACTOR SHALL COORDINATE WAP LOCATION WITH CASEGOODS TO AVOID CONFLICT. 5 EACH CABLE MUST HOMERUN BETWEEN THE GUESTROOM AND THE OF ON EACH FLOOR. 6 PATAIPOWERRECEPTACLELOCATIONFORCONNECTIVITY PANEL. ACC KING ONE BEDROOM R.I.S )ACC KING STUDIO CONNECTING )ACC 7 CONTRACTOR SHALL PROVIDE J-BOX W ITH CONTROLLING SWITCH FOR MECHANICAL MOTORIZED SHADES FOR ALL ADA 11.011 U 1/411 `` 11.011 1/°�II GUESTROOM. — V — 8 CONTRACTOR TO COORDINATE WITH KITCHEN VENDOR AND PROVIDE NECESSARY ELECTRICAL POWER OUTLET WITH PROPER SPACING IN ACCORDANCE TO NEC SECTION 210.52(B) AND 210.11(C)(1). 9 CONTRACTOR SHALL PROVIDE THERMOSTAT AT GIVEN HEIGHT FORALLGUESTROOMS. 75 ED — 10 JUNCTION BOX FOR GARBAGE DISPOSAL. 11 CONTRACTOR SHALL PROVIDE DEDICATED CIRUCUITWITH SWITCH CONTROLLING FOR GARBAGE DISPOSAL. CKT: OR REFRIGERATOR @1'-0"APP 12 CONTRACTOR SHALL PROVIDE CAT-6 CABLE FOR TV OUTLET, DATA OUTLET AND TELEPHONE OUTLET. OR MICROWAVE @6'-5"AFF HORIZONTAL 13 ALTERNATE LOCATION FOR W INDOW SHADE J-BOX AT LOCATIONS WHERE WINDOW DOES NOT EXTEND TO FILING. 1'-0"AFF CKT: OR UTILITY @3'-6"AFF J-BOX COVER TO BE PAINTED TO MATCH ADJACENT WALL FINISH. O C '3 CKT:6 CKT:7 OR GARBAGE DISPOSAL 14 GUEST ROOM PANEL BOARD SHALL BE FLUSH MOUNTED ON WALL AND MAINTAIN MIN. 2HR FIRE RESISTANCE RATING OF THE @1'-0'AFF WALL. CONTRACTOR SHALL PROVIDE MAINTAIN MINIMUM CLEAR 1'-D"AFF 1 0"AFF 11 10 CKT: OR DISHWASHER @1'-0"AFF SWITCH FOR GARBAGE SPACE AS PER NEC 2008 ARTICLE 110.26. 3'-5"AFF -fi KT.2 3 F 14 9 CKT: 8 DISPOSAL@3'-6"AFF OR UTILITY@3'-6"AFF 15 CONTRACTOR SHALL PROVIDE RFID/RADIO FREQUENCY IDENTIFICATION LOCKS.LOCK MUST ALSO BE H ILTON BILE 5 VIENABLED FOR INTEGRATION WITH THE HILTON'STRAIGHT TO ROOM'PROGRAM. 12 Z 12 1'-0"AFF 3 CUSTOM p 3'-6"AFF pNG 3'-6"AFF fi ® Y 1 eFF STUDIO 402 C GUEST ROOM KITCHEN EQUIPMENT SCHEDULE QTY EQUIPMENT CATEGORY ELEC. LOAD ELECTRICAL MOUNTING INW SUPPLY HEIGHTAFF 2 3 4 CUSTOM PNL'C' CKT:2 2 1'-5"AFF 12 TI1AFF 1 DISHWASHER 1080 120I60HL1Ph VI12 1 GARBAGE DISPOSAL 540 120/60Hz)1Ph 1'-D"AFF '-9"AFF KING ONE BEDROOM 1'-0"AFF 1 MICROWAVE 1740 120/60Hz/1Ph -5"AFF(HORI) FOR UTILITY@3'-6"AFF 11 1 REFRIGERATOR 1260 120/60H;s1Ph VI"AFF SWITCH FOR DISPOSAL @3'4i"AFF CKT:9 CKT:B FOR DISHWASHER 10 CKT O9 12 r @1'-0"AFF KT'S S CKT: — VIJ-BOX FOR GARBAGE 1 CKT: DISPOSAL @1'-0"AFF KT'S i FOR UTILITY B @3'-6"AFF FOR MICROWAVE "AFF @6'-5"AFF HORIZONTAL 72 FOR REFRIGERATOR CKTA o @i'-0"AFF 20/10,12 20/2P 1 3'-4"AFF [)WID 1'-0"AFF- — — 15 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations State local Codes CUSTOM KING ONE BEDROOM CUSTOM KING STUDIO — of and n J n Y CityofCarrin�d 1/411 = 11.011 1/411 = 11.011 T1Nt10.Y- DATE: 07/22/19 Am BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.Dom RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF QP��'\si EHh� e' m N 1 12 o ATE 90 . ''1:01I PNP:'2b CBS rONAI DATE: 20190304 OAEEY VE2MM5. PhD. PE Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 EO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO 134-134-1705 SHEET NAME TYPICAL UNIT ELECTRICAL POWER PLAN-1 DRAWINGS NO. E-209