E-301 - PANEL SCHEDULE-
SERVICE:2 PXASE,3-WIRE PANELA' MAIN BUS (A) 100 VOLTAGE:120/208 NEUTRAL 100% MOUNTING:FLUSH MOUNTED MAINS (A) I TYPE:LOAD CENTRE AIC(A) 10,000 LOAD DESCRIPTION CKT NO. TRIP POLE WIRE CONDUIT NCH LOAD CONDUIT INCH WIRE TRIP POLE CKT NO. LOAD DESCRIPTION LIVING AREA RCPT I 20/1P 12 3/4 1260 1260 3/4 12 20/1P 2 BEDROOM AREA RCPT BATHROOM RCPT 3 20/1P 12 3/4 260 1260 3/4 12 20/1P 4 REFRIGERATOR MICROWAVE 5 20/1P 12 3/4 1740 1080 3/4 12 20/1P 6 DISHWASHER KITCHEN UTILITY RCPT 7 20/1P 12 3/4 1500 540 3/4 12 20/1P 8 GARBAGE DIPOSALJ-BOX 1-BOX FOR PTAC-1 9 20/2P 12 3/4 1500 1500 3/4 12 20/2P 10 1-BOX FOR PTAC-1 11 15 00 1500 12 KITCHEN UTILITY RCPT 13 20/1P 12 3/4 1500 14 SPACE SPACE 15 16 SPACE SPACE 17 18 SPACE SUBTOTALVA 9260 7140 SUBTOTALVA TOTAL 16400 LOAD CONNECTE DLOAD DEMAND FACTOR DEMAND LOAD 1) PROVIDE ALL NON LOCKING -TYPE, 125-VOLT, 25 AND 20-AMPERE RECEPTACLES LOCATED IN LIVING AREA, SLEEPINGAREA AND DINING AREA IN GUESTROOM AND GUESTSUITES SHALL BE PROTECTED BYA LISTED ARC_ FAULT CURRENT INTERRUPTER, COMBINATION TYPE, INSTALLEDTO PROVIDE PROTECTION OF BRANCH CIRCUITAS PER NEC 220.22. 2)AS PER Ni GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOTCONTRACTOR SHALL PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTAUE AT READILY ACCESSIBLE LOCATION. IF ANY GFCI RECEPTACLE COMING BEHIND EQUIPMENT PROVIDE GFCI PROTECTION IN BREAKERAS PER CODE. LIGHTING AND RCPT LOAD@3WATT/SQFT 2780 AS PER NEC 1704 MICROWAVE 1740 AS PER NEC 1740 REFRIGERATOR 1260 AS PER NEC 1260 DISHWASHER 1080 AS PER NEC 1080 GARBAGE DIPOSALI-BO% 540 AS PER NEC 540 SMALLAPPLIANCES 3000 AS PER NEC 3000 TOTAL LOAD IN VA 10400 9324 PAT 1OKW@100% 9324 AS PER NEC 9324 REMAINDER@40% 0 AS PER NEC 0 HVAC LOAD 6000 AS PER NEC 6000 TOTAL DEMAND LOAD 15324 15324 TOTAL LOAD IN AMPERE 64 64 TAKING 20%SPARE CAPACITY IN AMP 77 SERVICE:2 PXASE,3-WIRE PANELC MAIN BUS (A) 100 VOLTAGE:120/208 NEUTRAL 100% MOUNTING:FLUSX MOUNTED MAINS (A) I TYPE:LOAD CENTRE AIC(A) 10,000 LOAD DESCRIPTION CKT NO. TRIP POLE WIRE CONDUIT NCH LOAD CONDUIT INCH WIRE TRIP POLE CKT NO. LOAD DESCRIPTION LIVING AREA RCPT 1 20/1P 12 3/4 1440 900 3/4 12 20/1P 2 BEDROOM AREA RCPT BATHROOM RCPT 3 20/1P 12 3/4 260 1260 3/4 12 20/1P 4 REFRIGERATOR KITCHEN UTILITY RCPT 5 20/1P 12 3/4 1500 1740 3/4 12 20/1P 6 MICROWAVE GARBAGE DISPOSALI-BOX 7 1 20/113 12 3/4 540 1080 3/4 12 20/113 8 1 DISHWASHER KITCHEN UTILITY RCPT 9 20/1P 12 3/4 1500 1500 3/4 12 20/2P 10 1-BOX FOR PTAC-1 1-BOX FOR PTAC-1 11 20/2P 12 3/4 1500 1500 12 13 1500 14 SPACE SPACE 15 I I 1 16 SPACE SPACE 17 18 SPACE SUBTOTALVA 9240179901 1 1 SUBTOTALVA TOTAL 1 16220 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD I) PROVIDE ALL NON LOCKING-TYPE,125-VOLT, 15 AND 20-AMPERE RECEPTACLES LOCATED IN LIVING AREA, SLEEPING AREA AND DINING AREA IN GUESTROOM AND GUESTSUITES SHALL BE PROTECTED BY A LISTED ARC -FAULT CURRENT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF BRANCH CIRCUIT AS PER NEC 210.12. 2)AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTORSHALL PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLE AT READILY ACCESSIBLE LOCATION. IF ANY GFCI RECEPTACLE COMING BEHIND EQUIPMENT PROVIDE GFCI PROTECTION IN BREAKER AS PER [ODE. LIGHTING AND RCPT LOAD@3WATT/SQF1 2600 AS PER NEC 1692 GARBAGE DISPOSAL J-BOX 540 AS PER NEC 540 DISHWASHER 1080 AS PER NEC 1080 MICROWAVE 1740 AS PER NEC 1740 REFRIGERATOR SMALLAPPLIANCES 1260 3000 AS PER NEC AS PERNEC 1260 3000 TOTAL LOAD IN VA 10220 9312 1AT 1OKW@100% 9312 AS PER NEC 9312 REMAINDER@40% 0 AS PER NEC 0 HVAC LOAD 6000 AS PER NEC 6000 TOTAL DEMAND LOAD 15312 15312 TOTAL LOAD IN AMPERE 64 64 TAKING 20%SPARE CAPACITY IN AMP 77 SERVICE: 1 PHASE,3 WIRE DIMMING PANEL-"2„ MAIN BUSAOCIA VOLTAGE: 120/240 VAC NEUTRAL:100% MOUNfTING:WALL MOUNTED MAINS:MLO TYPE:LOAD CENTRE Ali 10,000 AMP AREA -ZONE DESCRIPTION CKT NO. TRIP POLE WIRE CONDUIT LOAD EMERGENCY CIRCUITS FIXTURE TYPE REGISTRATION DESK LTG 1 15/1P 12 3/41, 140 N/A LED LOBBY AREA LTG 2 151 12 3/41, 140 N/A LED LOBBY AREA LTG 3 15/1P 12 3/4" 200 N/A LED LOBBY AREA LTG 4 1S/1P 12 3/4" 140 N/A LED BREAKFAST AREA LTG 5 15/1P 12 3/4" 300 N/A LED BREAKFAST AREA LTG 6 15/lP 12 3/4" 90 N/A LED SERVERY AREA LTG 7 151 12 3/4" 70 N/A LED LOBBY AREA LTG 8 15/1P 12 3/4" 150 EM:45 LED BREAKFAST AREA LTG 9 15/1P 12 3/4" 180 EM:46 LED BREAKFAST AREA LTG 10 15/1P 12 3/4" 90 EM:47 LED SERVERY AREA LTG 11 15/1P 12 3/4" 60 EM:48 LED LOBBY AREA LTG 12 15/1P 12 3/4" 20 N/A LED 13 15/1P 12 3/4" LED 14 15/1P 12 3/4" LED TOTAL LOAD 1580 TOTAL LOAD IN AMPERE 13 Note: THIS DIMMER SCHEDULE AND RISER DAIGRAM IS FOR GENERAL REFERENCE. CONTRACTOR SHALL COORDINATE WITH DIMMERVENDOR FOR FINAL DIMMER SYSTEM DRAWING AND SPECIFICATION TAKING 10% SPARE CAPACITY IN AMP TAKING NEC SPARE CAPACITY IN AMP 14 18.10417 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� `�NmlUllBnrJnDIJ�L x DATE: 07/22/19 SERVICE:2 PXASE,3-WIRE PANEL'B' MAIN BUS (A) 100 VOLTAGE:120/208 NEUTRAL 100% MOUNTING:FLUSH MOUNTED MAINS(A) I TYPE:LOAD CENTRE All (A) 10,000 LOAD DESCRIPTION CKT NO. TRIP POLE WIRE CONDUIT NCHINCH LOAD CONDUIT WIRE TRIP POLE CKT NO. LOAD DESCRIPTION LIVING AREA RCPT I 20/1P 12 3/4 900 1080 3/4 12 20/1P 2 BEDSIDE AREA RCPT BATHROOM RCPT 3 20/1P 12 3/4 260 1260 3/4 12 20/1P 4 REFRIGERATOR MICROWAVE 5 20/1P 12 3/4 1740 1080 3/4 12 20/1P 6 DISHWASHER KITCHEN UTILITY RCPT 7 20/1P 12 3/4 1500 540 3/4 12 20/1P 8 GARBAGE DISPOSAL J-BOX J-BOX PI 9 20/2P 12 3/4 1500 1500 3/4 12 20/1P 10 KITCHEN UTILITY RCPT 11 1500 12 SPACE SPACE 13 14 SPACE SPACE 15 16 SPACE SPACE 17 18 SPACE SUBTOTALVA 7400 5460 SUBTOTAL VA TOTAL 12860 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD I) PROVIDE ALL NON LOCKING-TYPE,125-VOLT, 15 AND 20-AMPERE RECEPTACLES LOCATED IN LIVING AREA, SLEEPING AREA AND DINING AREA IN GUESTROOM AND GUESTSUITES SHALL BE PROTECTED BY A LISTED ARC -FAULT CURRENT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF BRANCH CIRCUITAS PER NEC 210.12. 2)AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI BREAKER I N PAN EL. FROM DE G FCI TYPE RECEPTACLE AT READILY ACCESSIBLE LOCATION. IF ANY GFCI RECEPTACLE COMING BEHIND EQUIPMENT PROVIDE GFCI PROTECTION IN BREAKER AS PER CODE. LIGHTING AND RCPTLOAD@3WAT7/SQ 2240 AS PER NEC 1332 GARBAGE DISPOSAL J-BOX 540 AS PER NEC 540 DISHWASHER 1080 AS PER NEC 1080 MICROWAVE 1740 AS PERNEC 1740 REFRIGERATOR SMALL APPLIANCES 1260 3000 AS PER NEC AS PER NEC 1260 3000 TOTAL LOAD IN VA 9860 AS PER NEC 8952 1AT 1OKW@100% 8952 AS PER NEC 8952 REMAINDER@40% 0 AS PER NEC 0 HVAC LOAD 3000 AS PER NEC 3000 TOTAL DEMAND LOAD 11952 11952 TOTAL LOAD IN AMPERE 50 50 TAKING 20%SPARE CAPACITY IN AMP 60 SERVICE:2 PHASE,3-WIRE PANEL'D' MAIN BUS (A) 100 VOLTAGE:120/208 NEUTRAL 100% MOUNTING:FLUSH MOUNTED MAINS (A) MLO TYPE:LOAD CENTRE All (A) 10,000 LOAD DESCRIPTION CKT NO. TRIP POLE WIRE CONDUIT NCH LOAD CONDUIT INCH WIRE TRIP POLE CKT NO. LOAD DESCRIPTION LIVING AREA RCPT 1 20/1P 12 3/4 900 1080 3/4 12 20/1P 2 BEDSIDE AREA RCPT BATHROOM RCPT 3 20/1P 12 3/4 260 1260 3/4 12 20/1P 4 REFRIGERATOR KITCHEN UTILITY RCPT 5 20/1P 12 3/4 1500 1740 3/4 12 20/1P 6 MICROWAVE GARBAGE DISPOSALI-BOX 7 20/1P 12 3/4 540 1080 3/4 12 20/1P 8 DISHWASHER KITCHEN UTILITY RCPT 9 20/1P 12 3/4 1500 1500 3/4 12 20/2P 10 J-BOX FOR PTAC-2 SPACE 11 1500 12 SPACE 13 14 SPACE SPACE 15 16 SPACE SPACE 17 18 SPACE SUBTOTALVA 4700 8160 SUBTOTALVA TOTAL 12860 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD I) PROVIDE ALL NON LOCKING-TYPE,125-VOLT, 15 AND 20-AMPERE RECEPTACLES LOCATED IN LIVING AREA, SLEEPING AREA AND DINING AREA IN GUESTROOM AND GUESTSUITES SHALL BE PROTECTED BY A LISTED ARC -FAULT CURRENT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF BRANCH CIRCUITAS PER NEC 210.12. 2)AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLE AT READILY ACCESSIBLE LOCATION. IF ANY GFCI RECEPTACLE COMING BEHIND EQUIPMENT PROVIDE GFCI PROTECTION IN BREAKERAS PER CODE. LIGHTING AND RCPT UOAD@3WATT/SCdF1 2240 AS PER NEC 1359 GARBAGE DISPOSAL J-BOX 540 AS PER NEC 540 DISHWASHER 1080 AS PER NEC 1080 MICROWAVE 1740 AS PER NEC 1740 REFRIGERATOR SMALLAPPLIANCES 1260 3000 AS PER NEC AS PER NEC 1260 3000 TOTAL LOAD IN VA 9860 8979 1AT 1OKW@100% 8979 AS PER NEC 8979 REMAINDER@40% 0 AS PER NEC 0 HVAC LOAD 3000 AS PER NEC 3000TAL TODEMAND LOAD 11979 11979 TOTAL LOAD IN AMPERE 50 50 TAKING 20%SPARE CAPACITY IN AMP 60 II_VINIWTAI01�_1►1NImon] PANELC' I PANEL IDI DIMMER PANEL-Z BAS E'' BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF 4P��'\sipHA� e' m N 1 12 o ATE 90 . 01I PNP:'2b �gBrONAI E�` DATE: M1e 0a 04 GARRY VERYI Phi PE Owner: Q� �1 THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWISCENTER,OH 513 513-623-9430-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPNON 1 EO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT IN B4-134-1705 SHEET NAME PANEL SCHEDULE -I DRAWINGS NO. E=301