E-305 - PANEL SCHEDULE-V
SERVICE:3 PHASE,4-WIRE PANEL'HPA & HLA' MAIN BUS (A) 200 VOLTAGE:120/208 NEUTRAL(%) 100% ISO MOUNTING:WALL MOUNTED MAINS (A) TYPE:LOAD CENTRE All (A) 42,000 LOAD DESCRIPTION R PHASE B TRIP POLE WIRE CONDUIT(INCH) CKTNO. CKTNO. CONDUIT(INCH) WIRE TRIPPOLE PHA LOAD DESCRIPTION R B SECTION-1'HPA' 1st FLOOR COORIDOR RCPT 900 201 12 3/4 1 2 3/4 12 201 36o WOMEN TOILET RCPT EMPLOYEE BREAKROOM RCPT 540 20/1P 12 3/4 3 4 3/4 12 2011000 BREAKROOM REFRIGERATOR RCPT BREAKROOM MICROWAVE RCPT 800 20112 3/4 5 6 3/4 12 WAS 500 EMPLOYEE BREAKROOM RCPT VESTIBULE AREA RCPT 540 20112 3/4 7 8 3/4 12 2011440 BREAKFAST AREA RCPT BREAKFAST AREA RCPT 1260 20/1P 12 3/4 9 10 3/4 12 201 360 LOBBY BANQUET RCPT ENGINEERING ROOM RCPT 540 20112 3/4 11 12 3/4 12 2011260 LOBBY AREA RCPT LOBBY AREA RCPT 360 20112 3/4 13 14 3/4 12 201180 VESTIBULE AREA RCPT MEN'S TOILET RCPT 360 201 12 3/4 1S 16 SPACE FIRE PITIUNRION BOX-1 500 201 12 3/4 17 18 3/4 12 WAS 1080 EXTERIOR AREA RCPT EXTERIORAREA RCPT FITNESS TREADMILL RCPT FITNESS ELUPTICALRCPT 1260 1000 1000 201 20/1P 20/1P 12 12 12 3/4 3/4 3/4 19 21 23 20 22 24 3/4 3/4 3/4 12 12 12 201 20/lP(GFCI0 201 1090 1000 1000 FITNESS AREA RCPT FITNESS WATER COOLER RCPT FITNESS TREADMILL RCPT ELEVATOR LOBBY RCPT 180 201 12 3/4 25 26 3/4 12 201 540 ELECTRICAL ROOM RCPT MEETING ROOM RCPT 1260 20/1P 12 3/4 27 28 3/4 12 201 360 MECH AREA RCPT MEETING ROOM RCPT 1080 201 12 3/4 29 30 3/4 12 201 360 BREAKFAST AREA RCPT ENGINEERING ROOM RCPT 540 201 12 3/4 31 32 3/4 12 WAS 540 ENGINEERING ROOM RCPT ENGINEERING ROOM RCPT FOR MAINTENANCE 1500 20/2P 12 3/4 33 34 3/4 12 201 1500 ENGINEERING ROOM RCPT FOR MAINTENANCE 1500 35 36 1500 MEETING ROOM PROJECTOR RCPT 1000 201 12 3/4 37 38 3/4 12 201 1000 FITNESS CYCLE RCPT SPACE 39 40 SPACE SPACE 41 42 SPACE SPACE 43 44 SPACE SPACE 45 46 SPACE SPACE 47 48 SPACE SPACE SPACE 49 51 50 52 SPACE SPACE SPACE 53 54 SPACE SPACE 55 56 SPACE SPACE 57 58 SPACE SPACE 59 I60 SPACE SECTION-2'HLA' MEETING ROOM LTG 200 15/1P 12 3/4 1 2 3/4 12 15/1P 140 FOOD PREP/STORAGE AREA LTG MANAGER/SALES OFFICE LTG 100 1S/1P 12 3/4 3 4 3/4 12 1S/1P 150 WORKSTATION/MECH LTG LAUNDRY/LINEN STORAGE LTG 280 15/1P 12 3/4 5 6 3/4 12 15/1P 230 FITNESS ROOM LTG FITNESS ROOM/GUEST LAUNDRY LTG 130 15/1P 12 3/4 7 8 3/4 12 15/1P 100 ELECT/ENGG. ROOM LTG INDOOR POOLAREA LTG 420 1S/1P 12 3/4 9 10 3/4 12 1S/1P 60 INDOOR POOLAREA LTG INDOOR POOL/UNISEX/POOL EQUIP. LTG 220 15/1P 12 3/4 11 12 3/4 12 15/1P 1,200 50 PBX ROOM LTG VESTI Be LE LTG 30 15/1P 12 3/4 13 14 3/4 12 15/1P 160 1ST FLOOR CORRIDOR LTG BRKFAST/ELEV. LOBBY/MENSISWOMENS ITS 300 15/1P 12 3/4 15 16 3/4 12 15/1P 50 ELEV. LOBBY LTG SERVERV AREA LTG 200 15/1P 12 3/4 17 18 3/4 12 15/1P 260 1ST FLOOR CORRIDOR LTG OUTDOOR PATIO AREA LTG 40 15/1P 12 3/4 19 20 3/4 12 201 OUTDOOR PATIO AREA LTG OUTDOOR PATIO AREA LTG 1000 15/1P 12 3/4 21 22 3/4 12 15/1P 1000 OUTDOOR PATIO AREA LTG OUTDOOR PATIO AREA LTG 30 15/1P 12 3/4 23 24 3/4 12 15/1P 110 OUTDOOR PATIO AREA LTG OUTDOOR PATIO AREA LTG 40 15/1P 12 3/4 25 26 3/4 12 15/1P 60 VESTIBULE/MECH LTG PORTE COCHEREAREA LTG 150 15/1P 12 3/4 27 28 3/4 12 201 1580 DIMMER PANEL OUTDOOR PATIO AREA LTG 1000 15/1P 12 3/4 29 30 SPACE SPACE 31 32 SPACE SPACE 33 34 SPACE SPACE 35 36 SPACE SPACE 37 38 SPACE SPACE 39 40 SPACE SPACE 41 42 SPACE SUBTOTALVA 5220 7890 7150 6800 7060 6350 SUBTOTALVA 5220 12020 7890 7150 14950 13500 TOTAL VA: 40470 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD NOTE: 1) AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLEAT READILY ACESSIBLE LOCATION. IF ANY GCFI RECEPTACLE COMING BEHIND EQUIPMENT PROVIDE GFCI PROTECTION IN BREAKER AS PER CODE. LIGHTING (INTERIOR) 9290 1.25 11613 LIGHTING (EXTERIOR) 1.25 0 RCPT 20A 16020 NEC ARTICLE 220.44 13010 RCPT 30A-100A NEC ARTICLE 220.44 HVAC NEC ARTICLE NO 220.82 HVAC COOLING 1 0 HVAC HEATING 1 0 EXHAUSTLOAD 1 0 AHU 1 0 MOTOR NEC ARTICLE 430.24 25% LARGEST MOTOR 1 0 MISC LOAD 15160 1 15160 TAL TOLOAD IN VA 40470 39783 TOTAL LOAD IN AMPERE 112 110 TAKING 20% SPARE CAPACITY IN AMP 133 PANEL'HPA' &'HLA' PANEL 'LP' PANEL 'SEP' RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� `�vmlU'lDnrJnD1J�L x DATE: 07/22/19 SERVICE:3 PHASE,4-WIRE PANEL LP MAIN BUS (A) 100 VOLTAGE:120/209 NEUTRAL(%) 100% MOUNTING:WALL MOUNTED MAINS (A) 100 TYPE:LOAD CENTRE All (A) 10,000 LOAD DESCRIPTION PHASE R Y B TRIP POLE WIRE CONDUIT (INCH) CKT NO. CKT NO. CONDUIT (INCH) WIRE TRIP POLE PHASE LOAD DESCRIPTION R Y B MAIN LAUNDRY RCPT 9ON 20/1P 12 3/4 1 2 3/4 12 20/IP 360 LINEN STORAGE RCPT CHEMICAL DISPENSER 500 20/1P 12 3/4 3 4 3/4 12 20/IP 500 CHEMICAL DISPENSER MAIN LAUNDRY WASHER 1080 1090 15/3P 12 3/4 5 6 3/4 12 15/3P 1090 MAIN LAUNDRY WASHER 7 8 1080 1080 9 10 1080 MAIN LAUNDRY DRYER 480 480 15/3P 12 3/4 1 11 12 3/4 1 12 15/3P 480 MAIN LAUNDRY DRYER 13 14 480 480 15 1 16 480 MAIN LAUNDRY DRYER 4Be 480 15/3P 12 3/4 17 18 3/4 12 20/2P 1000 IRON POINT 480 19 20 loon 21 22 3/4 12 20/IP 360 GUEST LAUNDRY RCPT GUEST LAUNDRY WASHER 1000 20/1P(GFCI) 12 3/4 23 24 3/4 12 201 1000 GUEST LAUNDRY WASHER SPACE 25 26 SPACE GUEST LAUNDRY DRYER 1500 30/2P 10 3/4 27 28 3/4 10 30/2P 15007 GUEST LAUNDRY DRYER 1500 29 30 1500 LINEN CHUTE JUNCTION BOX 500 20/1P 12 3/4 31 32 SPACE SPACE SPACE 33 35 34 1 3 1 SPACE SPACE SPACE SPACE SPACE 37 39 41 38 40 42 1 SPACE SPACE SPACE SUBTOTALVA 3440 4040 4540 2920 3920 5060 SUBTOTALVA 3440 4040 1 4540 6360 7960 1 9600 TOTALVA: 23920 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD NOTE: 1) AS PER NEC 220.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFO BREAKER IN PANEL. PROVIDEGFCI TYPE RECEPTACLE AT READILY ACESSIBLE LOCATION. IFANY GCFI RECEPTACLE COMING BEHIND EQUIPMENT PROVEDE GFCI PROTECTION IN BREAKER AS PER CODE. LIGHTING (INTERIOR) 1.25 0 LIGHTING (EXTERIOR) 1.25 0 RCPT 20A 1620 NEC ARTICLE 220.44 RCPT 30A-100A NEC ARTICLE 220.44 HVAC NEC ARTICLE NO 220.82 HVAC COOLING 1 0 HVAC HEATING 1 0 EXHAUSTLOAD 1 0 AHU 1 0 MOTOR NEC ARTICLE 430.24 LAUNDRY LOAD 22300 NEC ARTICLE 220.54 22300 25% LARGEST MOTOR 1 0 MISC LOAD 1 0 TOTAL LOAD IN VA 23920 22300 TOTAL LOAD IN AMPERE 66 62 TAKING 20%SPARE CAPACITY IN AMP 74 SERVICE:3 PHASE,4-WIRE PANEL'SEP MAIN BUS (A) 200 VOLTAGE:120/208 NEUTRAL(%) 100% MOUNTING:WALL MOUNTED MAINS (A) 150 TYPE:LOAD CENTRE All (A) 42,000 LOAD DESCRIPTION PHASE R Y B TRIP POLE WIRE CONDUIT (INCH) CKTNO. CKTNO. CONDUIT (INCH) WIRE TRIP POLE R PHASE Y B LOAD DESCRIPTION DUMPSTER AREA RCPT 720 201 12 3/4 1 2 2 lAL LOCI10000 CAR CHARGING STATION CAR CHARGING STATION 10000 10000 1001 1AL 2 S 6 10000 3/4 12 201 250 SITE SIGNAGE J-BOX ROOF SINGNAGE J-BOX 250 250 11111[201 12 3/4 7 9 8 10 250 3/4 12 15/2P 260 SITE LIGHTING 260 SITE LIGHTING 370 15/2P 12 3/4 11 12 370 13 14 3/4 12 15/2P 250 SITE LIGHTING SITE LIGHTING 300 15/IP 12 3/4 15 16 250 DUMPSTER AREA 80 15/1P 12 3/4 17 18 SPACE SPACE 19 1 20 1 SPACE SPACE 1 21 1 22 1 SPACE SPACE 23 24 SPACE SPACE 25 26 SPACE SPACE 27 28 SPACE SPACE 29 30 SPACE SUBTOTALVA 1340 10350 104501 10500 10510 510 SUBTOTALVA 1340 10350 10450 11840 20860 10960 TOTAL VA: 43660 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD NOTE: 1) AS PER NEC 220.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLE AT READILY ACESSIBLE LOCATION. IF ANY GCFI RECEPTACLE COMING BEHIND EQUIPMENT PROVEDEGFCI PROTECTION IN BREAKERAS PER CODE. LIGHTING (INTERIOR) 1.25 0 LIGHTING (EXTERIOR) 1940 1.25 2425 RCPT 20A 720 NECARTICLE 220.44 720 RCPT 30A-100A NEC ARTICLE 220.44 HVAC NEC ARTICLE NO 220.82 HVAC COOLING 1 0 HVAC HEATING 1 0 EXHAUSTLOAD 1 0 AHU 1 0 MOTOR NEC ARTICLE 430.24 tR%FkdW8T,NIUIPA 1 0 LOAD 40000 1 40000 MISC LOAD 1000 1 1000 TOTAL LOAD IN VA 43660 44145 TOTAL LOAD IN AMPERE 121 123 TAKING 20% SPARE CAPACITY IN AMP 247 BAS E'' BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QP��'\si EHh� 1 12 o ATE OF �gBrONAI E�` DATE: M1e0aoa GARRY YERNMS. PhD. PE Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWISCENTEFeOH 513 513-623-9430-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 EO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO, B4-134-1705 SHEET NAME PANEL SCHEDULE-V DRAWINGS NO. E=305