Loading...
HomeMy WebLinkAboutE-306 - PANEL SCHEDULE-VISERVICE:3 PHASE,4-WIRE PANEL'SP' MAIN BUS (A) 100 VOLTAGE:120/208 NEUTRAL(%) 200% MOUNTING:WALL MOUNTED MAINS (A) 100 TYPE:LOAD CENTRE All A 10000 LOAD DESCRIPTION PHASE R Y 8 TRIP POLE WIRE CONDUIT (INCH) CKT NO. CKT NO. CONDUIT (INCH) WIRE TRIP POLE PHASE LOAD DESCRIPTION R Y B POOL AREA RCPT 54U 360 20/1F 20/1P 12 12 3/4 3/4 1 3 2 4 3/4 3/4 12 12 20/1P 20/1P 180 360 POOL VESTIBULE RCPT POOL STORAGE RCPT POOL EQUIPMENT RCPT POOL UNISEX RCPT 360 20/1P 12 3/4 5 6 3/4 12 20/1P 500 POOL ADA SEAT J-BOX POOL UNDERWATER LTG 60 15/1P 12 3/4 7 8 3/4 10 301 1350 POOL FILTER PUMP DRINKING FOUNTAIN RCPF 500 20/1P 12 3/4 9 10 1350 SPACE 11 12 1350 SPACE 13 14 SPACE SPACE 15 16 SPACE SPACE 17 18 SPACE SPACE 19 20 SPACE SPACE 211 22 SPACE SPACE 23 1 24 SPACE SUBTOTAL VA 600 860 360 1 2530 1710 1 1850 SUBTOTALVA 600 860 1 360 Z130 Z570 I ZZ10 TOTALVA: 6910 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD NOTE: 1) AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLE AT READILY ACESSIBLE LOCATION. COMING BEHIND EQUIPMENT PROVEDE GFCI PROTECTION IN BREAKER AS PER CODE. CONTRACTOR SHALL PROVIDE IF ANY GCFI RECEPTACLE LIGHTING (INTERIOR) 60 1.25 75 LIGHTING (EXTERIOR) 1.25 0 RCPT 20A 1800 NEC ARTICLE 220.44 1800 RCPT 30A-100A NEC ARTICLE 220.44 0 HVAC NEC ARTICLE NO 220.82 HVAC COOLING 1 0 HVAC HEATING 1 0 EXHAUSTLOAD 1 0 AHU 1 0 MOTOR NEC ARTICLE 430.24 POOLWATERHEATER 500 1.25 625 POOL FILTER PUMP 4050 1 4050 25%LARGEST MOTOR 4050 0.25 1013 MISC LOAD 500 1 500 TOTAL LOAD IN VA 6910 8063 TOTAL LOAD IN AMPERE 1 19 22 TAKING 20% SPARE CAPACITY IN AMP 27 SERVICE:3 PHASE,4-WIRE PANEL'PP' MAIN BUS (A) 100 VOLTAGE:120/208 NEUTRAL(%) 100% MOUNTING:WALL MOUNTED TYPE:LOAD CENTRE MAINS (A) 100 AIC(A) 10,000 LOAD DESCRIPTION PHASE R Y B 'TRIP POLE WIRE CONDUIT (INCH) CRT NO. CKT NO. CONDUIT (INCH) WIRE TRIP POLE PHASE R Y B LOAD DESCRIPTION MECHANICAL ROOM RCPT GWH-2 360 450 20/1P 20/1P 12 12 3/4 3/4 1 3 2 4 3/4 3/4 12 12 20/1P 20/1P 450 450 GWH-1 GWH-3 GWH-4 450 20/1P 12 3/4 5 6 3/4 12 20/1P 500 WATER SOFTNER CP-1 625 20/1P 12 3/4 7 8 3/4 12 20/1P 285 CP-2 BOOSTER PUMP 2990 40/3P 8 3/4 9 10 3/4 12 20/2P 900 POOLWATER HEATER 2990 11 12 900 2990 13 14 3/4 12 20/1P 450 GWH-5 SPACE 15 16 SPACE SPACE 17 18 SPACE SPACE 19 20 SPACE SPACE 21 22 SPACE SPACE 23 24 SPACE SPACE 25 26 SPACE SPACE 27 28 SPACE SPACE 29 30 MTOTALVA: ME 06=ASPACE SUBTOTALVA 3975 3440 3440 1185 1350 1400 SUBTOTALVA 3975 3440 3440 1160 4790 4840 14790 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD NOTE: 1) AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLE AT READILY ACESSIBLE LOCATION. RECEPTACLE COMING BEHIND EQUIPMENT PROVEDE GFCI PROTECTION IN BREAKER AS PER CODE. SHALL IF ANY GCFI LIGHTING (INTERIOR) 1.25 0 LIGHTING (EXTERIOR) 1.25 0 RCPT 20A 360 NEC ARTICLE 220.44 360 RCPT 30A-100A NECARTICLE 220.44 HVAC NEC ARTICLE NO 220.82 HVAC COOLING 1 0 HVAC HEATING 1 0 EXHAUSFLOAD 1 0 AHU 1 0 MOTOR NEC ARTICLE 430.24 BOOSTER PUMP 8970 1 8970 CP PUMP 910 1 910 POOL WATER HEATER 1800 1 1800 25%LARGEST MOTOR 8970 0.25 2243 MISC LOAD 2750 1 2750 TOTAL LOAD IN VA 14790 15233 TOTAL LOAD IN AMPERE 41 42 TAKING 20%SPARE CAPACITY IN AMP 51 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� `�vmlUtlDnrJnD1J�L x DATE: 07/22/19 SERVICE:3 PHASE,4-WIRE PANEL'EP' MAIN BUS (A) 200 100% 200 65,000 VOLTAGE:120/208 NEUTRAL(%) MOUNTING:WALL MOUNTED MAINS (A) TYPE:LOAD CENTRE AIC(A) LOAD DESCRIPTION PHASE TRIP POLE WIRE CONDUIT(INCH) CKTNO. CKTNO. CONDUIT(INCH) WIRE TRIP POLE R PHASE B LOAD DESCRIPTION R B ELEVATOR-1 5284 9284 5284 fi0/3P (SHUNTTRIP) (3#6+1#6N+1#10G)CU 1 1 (3#6+1#6N+1#10G)CU fi0/3P 4203 ELEVATOR-2 3 4 4203 5 6 (SHUNTTRIP) 4203 ELEVATOR-1 CAB LIGHT 360 20/1P 12 3/4 7 8 3/4 10 30/2P 1391 SUMP PUMP ELEVATOR-2 CAB LIGHT ELEVATOR-2 PIT LIGHT 360 200 20/1P 20/1P 12 12 3/4 3/4 9 11 10 12 1391 3/4 12 200 ELEVATOR-2 CAB LIGHT ELEVATOR-1 RCPT 360 20/1P 12 3/4 13 14 3/4 12 360 ELEVATOR-2 RCPT SPACE SPACE SPACE 15 17 19 16 18 20 SPACE SPACE SPACE SPACE 21 22 SPACE SPACE 23 24 SPACE SPACE 25 26 PTOTALVA" SPACE SPACE 5484 27 29 28 30 5954 5594 4403 SPACE SPACE SUBTOTALVA 6004 5644 SPACE SUBTOTALVA 6004 5644 5484 11958 11238 9887 33083 LOAD CONNECTED LOAD DEMAND FACTOR DEMANDLOAD NOTE: 1)AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLE AT READILY ACESSIBLE LOCATION. IF ANY GCFI RECEPTACLE COMING BEHIND EQUIPMENT PROVEDE GFCI PROTECTION IN BREAKER AS PER CODE. LIGHTING (INTERIOR) 400 1.25 500 LIGHTING (EXTERIOR) 1.25 0 RCPT 20A 1440 NEC ARTICLE 220.44 1440 RCPT 3GA-100A NEC ARTICLE 220.44 HVAC NEC ARTICLE NO 220.82 HVAC COOLING 1 0 HVAC HEATING 1 0 EXHAUSTLOAD 1 0 AHU 1 0 MOTOR NEC ARTICLE 430.24 ELEVATORS-1 15852 1 15852 ELEVATORS-2 12609 1 12609 SUMPPUMP 2782 1 2782 25%LARGEST MOTOR 15852 1 15852 MISC LOAD 1 0 TOTAL LOAD IN VA 33083 49035 TOTAL LOAD IN AMPERE 92 136 TAKING 20%SPARE CAPACITY IN AMP 163 SERVICE:3 PHASE,4-WIRE VOLTAGE:120/208 MOUNTING:WALL MOUNTED TYPE:LOAD CENTRE PANEL'KP' MAIN BUS (A) 100 NEUTRAL(%) 100% MAINS (A) 100 10,000 AIC(A) LOAD DESCRIPTION PHASE R Y B TRIP POLE WIRE CONDUIT (INCH) CKT NO. CKT NO. CONDUIT (INCH) WIRE TRIP POLE R PHASE Y B LOAD DESCRIPTION KITCHEN RCPT 540 20/1P 12 3/4 1 2 3/4 12 20/1P 1800 KITCHEN CONVENIENCE RCPT KITCHEN CONVENIENCE RCPT 1800]2016 20/1P 12 3/4 3 4 3/4 8 50/3P 4203 UNDERCOUNTER DISHMACHINE JUICE DISPENSER 20/1P 12 3/4 5 6 4203 UNDERCOUNTER DISPLAY REFRIGERATOR 468 20/1P 12 3/4 7 8 4203 WARMING KETTLE 48020/1P 12 3/4 9 10 3/4 12 20/1P 480 REFRIGERATOR COLD WELL MICROWAVE OVEN 20/1P 12 3/4 11 12 3/4 12 20/1P 1728 CONVEYOR TOASTER WAFFLE IRON 1320 20/1P 12 3/4 13 14 3/4 8 40/2P 4428 MAKER RCPT MOBILE REACH IN FREEZER MOBILE REACH IN REFRIGERATOR 115220/1P(GFCI) 201 12 12 3/4 3/4 15 17 16 18 4428COFFEE SPACE SPACE 19 20 SPACE SPACE r 21 22 SPACE SPACE 23 24 SPACE SPACE 25 26 SPACE SPACE 27 28 SPACE SPACE 29 30 SPACE SUBTOTALVA 2328 3432 38M 30431 9111 5931 SUBTOTALVA 2328 3432 3864 12759 12543 9795 TOTAL VA: 35097 LOAD CONNECTED LOAD DEMAND FACTOR DEMAND LOAD NOTE: 1) AS PER NEC 210.8 GFCI RECEPTACLE SHALL BE ON READILY ACCESSIBLE LOCATION IF NOT CONTRACTOR SHALL PROVIDE GFCI BREAKER IN PANEL. PROVIDE GFCI TYPE RECEPTACLE AT READILY ACESSIBLE LOCATION. IF ANY GCFI RECEPTACLE COMING BEHIND EQUIPMENT PROVEDE GFCI PROTECTION IN BREAKER AS PER CODE. LIGHTING (INTERIOR) 1.25 0 LIGHTING (EXTERIOR) 1.25 0 RCPT 20A 540 NEC ARTICLE 220.44 0 RCPT 30A-100A NEC ARTICLE 220.44 0 HVAC NEC ARTICLE NO 220.82 HVAC COOLING 1 0 HVAC HEATING 1 0 EXHAUSFLOAD 1 0 AHU 1 0 MOTOR NEC ARTICLE 430.24 KITCHEN LOAD 34557 NEC ARTICLE 220.56 22462 MISC LOAD 1 0 TOTAL LOAD IN VA 35097 22462 TOTAL LOAD IN AMPERE 97 1TAKING 20%SPARE CAPACITY IN AMP 75 PANEL 'SP' PANEL 'EP' PANEL'PP' PANEL I BAS E'' BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 N W 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF 4P��'\'sYpHA� O.IP N i 1 12OF o ATE �g4r0NAl DATE: M1e 0a 04 GARRY WRNMS. PhD. HE Owner: t� tn THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 EO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SKJ CHECKED BY GWV PROJECT NO, B4-134-1705 SHEET NAME PANEL SCHEDULE -VI DRAWINGS NO. E=306