HomeMy WebLinkAboutFA-001 - GENERAL NOTES, LEGENDS AND ABBREVIATIONSI T1YF1. �EHIiOn GENERAL NOTES LEGENDS DRAWING INDEX SYMBOL I FIRE ALARM FIRE ALARM DEVICES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF THE FOLLOWING CODES/STANDARDS : 10. LABOR FOR THE INSTALLATION OF MATERIALS AND EQUIPMENT PROVIDED UNDER THE ELECTRICAL SHEET CURRENT CURRENT INTERNATIONALINTERNATIONAL OR CODE (IBC),NAND WORK SHALL BEPERFORMEDAND FIRST CLASS WORKMANSHIP LIKE CONTRACTORSSE PE OFEXPERIENCED SERVA ING NS, CONSERVATION CODE (IECC), AND ALL LOCAL CODES,ORDINANCES, REGULATIONS, AND THE AUTHORITY ALL OCALCODES, ORDINANCES, REGULATIONS, MANNER D QUALIFIEDOFTHE BE IN COMPLIANCE OF TDINANEER TRADE SHEET NAME REVISION HAVING JURISDICTION. HAVING SPECIFIC REQUIREMENTS AWING CODES, WITH THE SPECIFIC REQUIREMENTS OF THE CONTRACT DRAWINGS, AND ALL CODES, ORDINANCES OF H O HEAT DETECTOR, SURFACE MOUNTED NUMBER DATE DESCRIPTION DESCRIPTION STATUES, ETC. APPLICABLE. FA-001 GENERAL NOTES, LEGENDS AND 2019.03.04 ISSUED FOR PERMIT 2. ALL ELECTRICAL WORK PROVIDED FOR THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CRITERIA: CS COMBINATION OF SMOKE/CO DETECTOR WITHOUT SOUNDER BASE, SURFACE MOUNTED 11. FIELD DETERMINE EXACT INSTALLATION LOCATION OF FIRE PROTECTION REQUIREMENTS UNDER THE NFPA ABBREVIATIONS FA-101 FIRE ALARM DETAIL-1 2019.03.04 ISSUED FOR PERMIT A) TRADE SIZE CONDUIT SMALLER THAN 1/2 INCH SHALL NOT BE USED. AND MANUFACTURER'S WRITTEN INSTRUCTIONS. INCLUDE ALL FIRE ALARM SYSTEMS AND DETECTION SD SMOKE DETECTOR WITHOUT SOUNDER BASE, SURFACE MOUNTED FA-102 FIRE ALARM DETAIL-2 2019.03.04 ISSUED FOR PERMIT DEVICES. FA-201 1ST FLOOR FIRE ALARM PLAN 2019.03.04 ISSUED FOR PERMIT B) CONDUIT ABOVE GRADE AND NOT EXPOSED TO WEATHER SHALL BE PVC, ENT & MC. 12. ALL MOUNTING HEIGHTS INDICATED ARE MEASURED FROM FINISHED FLOOR UNLESS OTHERWISE NOTED. SD SMOKE DETECTOR WITH LOW FREQUENCY SOUNDER BASE, WALL MOUNTED FA-202 2ND FLOOR FIRE ALARM PLAN 2019.03.04 ISSUED FOR PERMIT C) CONDUIT BELOW GRADE AND PENETRATIONS AT GRADE SHALL BE SCHEDULE 40 PVC EXCEPT TURNS. SD SMOKE DETECTOR WITHOUT SOUNDER BASE, SURFACE MOUNTED FA-203 3RD FLOOR FIRE ALARM PLAN 2019.03.04 ISSUED FOR PERMIT 13. CONTRACTOR SHALL FURNISH THE ENGINEERING WITH SHOP DRAWINGS OF EQUIPMENT PRIOR D) CONDUIT ABOVE GRADE AND EXPOSED TO WEATHER SHALL BE SCHEDULE 80 PVC. TO PURCHASE FOR APPROVAL. F� COMBINATION AUDIO/VISUAL FIRE ALARM SYSTEM INDICATING DEVICE FA-204 141H FLOOR FIREALARM PLAN 2019.03.04 ISSUED FOR PERMIT E) WIRE SIZE SMALLER THAN #12 Awg. SHALL NOT BE USED FOR POWER CKT. #18 Awg.SHALL BE USED FOR LOW 14. ALL EQUIPMENTS AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR AFTER THE DATE OF FA-205 5TH FLOOR FIRE ALARM PLAN 2019.03.04 ISSUED FOR PERMIT FA-206 I ROOF FIRE ALARM PLAN 12019.03.04 1 ISSUED FOR PERMIT VOLTAGE CKT. ACCEPTANCE BY OWNER. © MANUAL FIRE ALARM PULL STATION, MOUNTED F) BRANCH CIRCUIT WIRING PROVIDED BY THE ELECTRICAL CONTRACTOR SHALL BE COPPER; FEEDER & SERVICE FA-301 ITYPICAL FIRE ALARM RISER DIAGRAM 12019.03.04 1 ISSUED FOR PERMIT WIRING SHALL BE ALUMINUM. 15. AT COMPLETION OF JOB THE FIRE ALARM CONTRACTOR SHALL GIVE THE OWNER AN AS -BUILT SET OF U VISUAL FIRE ALARM SYSTEM INDICATING DEVICE G) ALL CONDUCTORS SHALL HAVE A MINIMUM TEMPERATURE RATING OF 75 DEGREES C. (TYPE THAN REPRODUCIBLE DRAWINGS SHOWING THE EXACT FIRE ALARM DEVICE INSTALLATION, WRITTEN MAINTENANCE INSTRUCTIONS AND SCHEDULE OF ROUTINE MAINTENANCE AS WELL AS ANY OTHER FIRE DEPARTMENT LOCK BOX, MOUNTING HEIGHT PER FIRE DEPARTMENT OR TYPE THHN), 98% COPPER OR ALUMINUM. CLOSE OUT ITEMS REQUIRED BY THE CONTRACT DOCUMENTS. H) WHERE POSSIBLE, EXCEPTAS SHOWN OTHERWISE ON THE DRAWINGS,ALL CONDUIT SHALL BE RUN CONCEALED RF RADIO RESPONDER, SURFACE MOUNTED BELOW GRADE,WITHIN WALLS OR ABOVE CEILING. 16. BEFORE BIDDING THE JOB THE FIRE ALARM CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH TS TAMPER SWITCH I) CONDUCTORS #12 AWG AND SMALLER SHALL BE SOLID. CONDUCTOR 10# AWG AND LARGER SHALL BE STRANDED. ANY EXISTING CONDITIONS. CONDUCTOR#12 AWG MAY BE SOLID OR STRANDED, EXCEPT THAT ONLY#12 AWG SOLID OR ONLY#12 AWG Fg FLOW SWITCH STRANDED SHALL BE USED. 17. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT AN OPERATING MANUAL AND MAINTENANCE MANUAL BE J) THERE SHALL BE NO MORE THAN 270 DEGREES TOTAL TURN OR 150 FEET BETWEEN PULL POINTS IN CONDUIT PROVIDED TO THE BUILDING OWNER. THE MANUALS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING: CO CO DETECTOR WITH SOUNDER, SURFACE MOUNTED RUNS. A)SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF K) EQUIPMENT REQUIRING MAINTENANCE. �p LOW VOLTAGE SPEAKER, CEILING MOUNTED FIRE ALARM DEVICE MOUNTING HEIGHTS SHALL COMPLY WITH ALLANSI 117, NFPA 72 AND IBC REQUIREMENTS, B) OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING AT THE MINIMUM INSTALL ALL DEVICES AS FOLLOWS: MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. C) NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. Fpgp FIRE ALARM ANNUNCIATOR PANEL 18. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS FREE OF DUSTAND DUST PRODUCING ACTIVITIES, FACP FIRE ALARM CONTROL PANEL JUST PRIOR TO FINAL INSPECTION FOR CERTIFICATE OF OCCUPANCY. 19, AT COMPLETION OF WORK, CONTRACTOR SHALL CLEAN UP AND REMOVE ALL DEBRIS AND MATERIALS NOT _411111i FIRE SMOKE DAMPER, FBSD o ws�nayw¢ INSTALLED IN WORK, LEAVING PREMISES CLEAN. FTw7c TWO WAY COMMUNICATION BOX 20. THE STROBE INTENSITY OF ALL VISUAL NOTIFICATION APPLIANCES SHALL BE IN ACCORDANCE WITH �.n....a..c NFPA 72 AND UL 1971. STROBE CANDELA RATINGS SHALL BE PROVIDED IN ACCORDANCE WITH DEVICE LOCATIONS AND SHALL CONFIRM TO NFPA 72 INSTALLATION REQUIREMENTS. CONTRACTOR SHALL PROVIDE THE REQUIRED CANDELA POWER AND LOCATE ALL VISUAL NOTIFICATION APPLIANCES AS REQUIRED TO MEET THE REQUIREMENTS OF ALL REFERENCED CODES AND STANDARDS. II M To, �.a �CTW 0 Asa a pmmucmu, 1e s IAVNIN 3. CONTRACTOR SHALL: A) OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS, ASSOCIATION DUES, ROYALTIES, AND TAXES OF WHATEVER NATURE WHICH SHALL APPLY TO THE WORK. B) PAY ALL INSPECTION FEES AS REQUIRED BY LAW OR ORDINANCE. C) HOLD THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, RULES, OR ORDINANCES. D) PROVIDE MATERIALS THAT ARE NEW AND FREE OF DEFECTS AND UL LISTED FOR THE INTENDED APPLICATION. E) TAKE MEASUREMENTS AND MAKE LAYOUTS AS REQUIRED FOR PROPER INSTALLATION AND COMPLETION OF WORK IF THE ELECTRICAL DRAWINGS ARE NOT TO BE SCALED, WHERE SPECIFIC DETAILS AND DIMENSIONS FOR ELECTRICAL WORK ARE NOT SHOWN IN DRAWINGS. F) INSPECT SITE FOR FIELD VERIFICATION OF ALL ASPECTS OF THE PROJECT PRIOR TO BIDDING. G) EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. H) BE REQUIRED TO FURNISH, INSTALLAND/OR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, PLUMBING, AIR CONDITIONING, SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. 4. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE AT HIS EXPENSE, ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES 5, PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS TO PERFORM ALL WORK NECESSARY FOR THE COMPLETE EXECUTION OF THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS. 6. DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS, UNLESS SPECIFIC DIMENSIONS ARE SHOWN. THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. IF THE LOCATION OF FIRE ALARM DEVICES ARE NOT SHOWN ON ARCHITECTURAL DRAWINGS, THE CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, OR SPACES OR CONDITIONS AT ALL POINTS. WHERE HEAD ROOM OR SPACES OR CONDITIONS APPEAR INADEQUATE, ARCHITECT/ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATIONS IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS DISCIPLINES OR FOR PROPER EXECUTION OF WORK. WHERE DISCREPANCIES OCCUR, THE ARCHITECTURAL REFLECTED CEILING PLANS TAKE PRECEDENCE OVER THE FIRE ALARM FOR LOCATION AND ORIENTATION OF DEVICES. 7. ALL DISCREPANCIES OF DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING IN AMPLE TIME TO PERMIT REVISIONS PRIOR TO SUBMISSION OF BIDS. SUBMISSION OF A BID CONSTITUTES ACCEPTANCE OF FIELD CONDITIONS AND FIRE ALARM DRAWINGS. B. PROVIDE MEANS FURNISH AND INSTALL COMPLETE AND READY FOR USE. 9. DRAWINGS DO NOT NECESSARILY INDICATE THE ACTUAL ROUTES OF CONDUIT. WHERE INDICATED, THEY SHALL BE FOLLOWED AS CLOSELYAS PROPER COORDINATION WITH THE WORK OF OTHER TRADES AND SPACES WILL PERMIT. WHERE CONDUIT RUNS ARE NOT SHOWN ON THE DRAWINGS, COORDINATE CONDUIT RUNS WITH THE WORK OF OTHER TRADES AND STRUCTURE. SIMPLIFY INSTALLATION WHERE POSSIBLE, BUT SUBJECT TO APPROVAL OF ARCHITECT FOR VISUAL AND STRUCTURAL REASONS. IT IS NOT W ITHIN THE SCOPE OF THE DRAWINGS TO SHOW ALL NECESSARY OFFSETS, BENDS, PULL BOXES, AND OBSTRUCTIONS. THE DRAWINGS ARE NOT INTENDED TO BE SCALED AND REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel hAIOM1R a DATE: 07/22/19 BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 Www.base-4.com RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF PP��'\STEHh �' cs%p m N 1 12 o AE a OF �gBrONAL E�` DATE: 2o19.oa.oa OABBY VERMAAS. Phi PE Owner: I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 FAO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY AM CHECKED BY GWV PROJECT NO B4-134-1705 SHEET NAME GENERAL NOTES, LEGENDS AND ABBREVIATIONS DRAWINGS NO. FA=001