HomeMy WebLinkAboutFA-102 - FIRE ALARM DETAIL-2OF goo FLOW SWITCH FIRE ALARM MONITOR MODULE WATER FLOW INDICATION (ALARM CONDITION) ❑ ❑ ❑ ❑ ❑ LL.`I, FALL` "ALL FIRE ALARM MONITOR MODULE -0 b� S TEMPER SWITCH ❑M ER SWITCH (SUPPERVISERVIS (SUPERVISORY CONDITION) �FIRE RESET ALA DRILL ILENc -O ALARM MONITORMODULE ��WATER FLOW NDICATION (ALARM CONDITION) RESET SUPER TROUBLE MONITO C ED dI� Q O O O �H FIRE ALARM MONITOR MODULE OS&Y TAMPER SWITCH FROM SUPPLY RISER TO SPRINKLER SYSTEM (SUPERVISORY CONDITION) aO O6 sO 0 INDICATING VALVE WITH TAMPER SWITCH FLOW TCH SWI T e s � O TO DRAIN RISER — PIPE DISCHARGE TO FLOOR DRAIN 1 2 3 FIRE ALARM ANNUNCIATOR PANEL (FAAP) SPRINKLER ALARM VALVE ASSEMBLY DETAIL TYP. FLOOR CONTROL VALVE ASSEMBLY DETAIL FIRE FIGHTER PHASE ONE ELEVATOR SEQUENCE OF OPERATION: THE ALARM ACTIVATION OF ANY ELEVATOR LOBBY, TOP OF SHAFT, ELEVATOR PIT AND/OR MACHINE ROOM SMOKE DETECTOR SHALL, IN ADDITION TO ALL FIRE ALARM HEAT DETECTOR (FIXED TEMP 135 DEGREE OPERATION, CAUSE THE ELEVATOR CABS TO BE RECALLED ACCORDING TO THE SHALL BE LOCATED WITHIN 2'-0" OF EACH SPRINKLER HEAD FOLLOWING SEQUENCE; 1. IF THE ALARMED SENSOR IS ON ANY FLOOR OTHER THAN THE MAIN LEVEL ADDRESSABLE SMOKE DETECTOR OF EGRESS, THE ELEVATOR CABS SHALL BE RECALLED TO THE MAIN LEVEL OF EGRESS. 2. IF THE ALARM SENSOR IS ON THE MAIN EGRESS LEVEL, THE ELEVATOR CABS SHALL BE RECALLED TO THE PREDETERMINED ALTERNATE RECALL TOP OF SHAFT LEVEL AS DETERMINED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 3. THE ALARM ACTIVATION OF ANY ELEVATOR SHAFT AND/OR MACHINE ROOM HEAT DETECTOR SHALL ACTIVATE A "SHANT TRIP BREAKER DISCONTINUING OPERATION OF ELEVATOR POWER. ADDRESSABLE SMOKE DETECTOR - NOTE LOBBY SMOKE DETECTOR SHALL BE NOTE: OPERATING TEMPERATURE FOR ALL ELEVATOR SHAFT AND MACHINE LOCATED ON THE CEILING WITHIN 21 FT OF THE CENTERLINE OF EACH ROOM HEAT DETECTORS SHALL BE RATED AT 135 DEGREE FIXED TEMPERATURE ELEVATOR DOOR FOR EACH ELEVATOR CAB (TYPICAL ALL FLOORS) AND SHALL BE INSTALLED WITH IN 24" OF EVERY SPRINKLER HEAD. COORDINATE WITH SPRINKLER CONTRACTOR FOR EXACT QUALITY AND LOCATED OF ALL <2ND FLOOR MEZZANINE> SPRINKLER HEADS. ELEVATOR LOBBY FIRE ALARM MONITOR MODULE TYPICAL FOR ONE FOR EACH OS&Y TAMPER SWITCH (SUPERVISORY CONDITION) ALL FIRE ALARM DEVICES AND PROGRAMMING SHALL BE IN ACCORDANCE WITH ALL REQUIREMENT OF NFPA 72 AND ANSI 17.1 UNLESS OTHERWISE DIRECTED BY THE AUTHORITY HAVING JURISDICTION. \ADDRESSABLE SMOKE DETECTOR - NOTE LOBBY SMOKE DETECTOR SHALL BE ADDRESSABLE SMOKE DETECTOR LOCATED ON THE CEILING WITHIN 21 FT OF THE CENTERLINE OF EACH ELEVATOR DOOR FOR EACH ELEVATOR CAB (TYPICAL ALL FLOORS) HEAT DETECTOR (FIXED TEMP 135 DEGREE) SHALL BE LOCATED WITHIN 2'-0" OF EACH SPRINKLER HEAD <2ND FLOOR> ELEVATOR LOBBY SHUNT TRIP OPERATION FIRE FIGHTERS PHASE ONE OPERATION (PRIMARY) CM ADDRESSABLE CONTROL MODULE ADDRESSABLE SMOKE DETECTOR - NOTE LOBBY SMOKE DETECTOR SHALL BE FIRE FIGHTERS PHASE ONE (TYPICAL) LOCATED ON THE CEILING WITHIN 21 FT OF THE CENTERLINE OF EACH OPERATION (ALTERNATE) CM]ELEVATOR H DOOR FOR EACH ELEVATOR CAB (TYPICAL ALL FLOORS) ELEVATOR CAB VISUAL,cM ELEVATOR WARING SIGNAL MACHINE <1ST FLOOR am cM ROOM ELEVATOR LOBBY HEAT DETECTOR (FIXED TEMP 135 DEGREE) SHALL BE LOCATED WITHIN 2'1 OF EACH SPRINKLER HEAD ELEVATOR ADDRESSABLE SMOKE DETECTOR THE ELEVATOR FIRE FIGHTER PHASE ONE RISER DIAGRAM HAS BEEN PROVIDED TO DEPICT THE GENERAL IS DIAGRAMMATIC ONLY AND ARRANGEMENT AND INTEGRATION OF THE FIRE ALARM SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL DEVICES AS REQUIRED TO COMPLY WITH ALL APPLICABLE LIFE SAFETY, BUILDING AND ELEVATOR CODE REQUIREMENT AS STIPULATED BY THE CONTRACT DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE WITH THE ELEVATOR PROVIDER AND ALL AFFECTED TRADES IN THE PROPER INTEGRATION OF THE FIRE ALARM SYSTEM. THE CONTRACTOR SHALL REFER TO RELATED PROJECT RELEASED FOR CONSTRUCTION DOCUMENTS FOR ADDITIONAL INFORMATION. B '•v,> Subject to compliance with all regulations rJ and local Codes ENTER ASSEMBLY DETAIL of StateCity ELEVATOR FIRE FIGHTER PHASE ONE AND SHUNT TRIP RISER DIAGRAM CitydCamel ee �1vmlUtlBnrJnwJ4L i7 AID DATE: 07/22/19 BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QP��'\si EHh� O' %p m N 1 12 o ATE OF �geronu,L eN° DATE : 20180304 GABBY VERMAAS. Phi HE Owner: Q� �1 1� �I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTOH CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO. DELTA ISSUED DATE DESCRIPTION 1 FAO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY AM CHECKED BY GWV PROJECT NO, 134-134-1705 SHEET NAME FIRE ALARM DETAIL-2 DRAWINGS NO. FA-102