Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FA-204 - 4TH FLOOR FIRE ALARM PLAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 100 19 20 21 I I I I I I I I I I I I I I I I I I I I IK lCr I I I I I JAI I I J D — — 1 07 r o ° D D D CUSTOM CUSTOM ° KING ONE I��y�QUEE QUEEN QUEEN/ QUEEN/ �O5 5.m BEDROOM QUEEN/ '�I ST�q KING KING KING KING ONE 401 ° QUEEN QUEEN QUEEN QUEEN/ 13 S S S BEDROOM KING5 STUDIO STUDIO STUDIO STUDIO ST QUEEN 415 417 419 421 --- 403 405 407 411 HE 5 © a10 olo olO alo 1 F 15cd RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel `�VT�11�D>n N DATE: 07/22/19 o® oo®®o F SAIMI 7mK j=LJ�'j 0 iI, o�O� : I IjamT mrs r�oL� � CUSTOM KING KING KING M [4j)8] N ISTUDII[4DI InYI^ul MIMI El©N h 15cd m L -KING— -KING SING KING U C PIRG STUDIO STUDIO STUDIo STUDIO STUDIO qpp qpp 424 416 8 I B I — — — — I I A.4 I I I I I I I I I I I I I I I 8 9 10 11� �12 �13 ' (�1\.'\/4TH FLOOR FIRE ALARM PLAN _. 1/8 11 /811 = 1 1.011 I I I I I I I I I I I I I I I I I ' 14 : 15,11 16 17 18 100 19 20 21 FA204-KEY NOTES ® Text 1 FIRE ALARM HORN/ STROBE MOUNTED AT 80-AFF AND I MIN. BELOW THE CEILING. 2 PROVIDE MANUAL PULL STATION 3 PHOTOELECTRIC LOW VOLTAGE COMBINATION OF SMOKE AND CO DETECTOR WITHOUT SOUNDER BASE, CEILING MOUNTED. 4 PHOTOELECTRIC LOW VOLTAGE SMOKE DETECTOR WITHOUT SOUNDER BASE CEILING MOUNTED. 5 CONTRACTORTO PROVIDE SMOKE DETECTORWITH LOW FREQUENCYHORN(SQUARE WAVE WITH FUNDAMENTAL FREQUENCY OF 520 HZ) IN EACH SLEEPING UNIT AS PER NFPA 72 SECTION 18.4.5. 6 FIRE VENDOR SHALL PROVIDE RADIO RESPONDER OF APPROVED RADIO COVERAGE FOR EMERGENCY RESPONDERS WITHIN THE BUILDING BASED UPON THE EXISTING COVERAGE LEVELS OF THE PUBLIC SAFETY COMMUNICATION SYSTEMS OF THE JURISDICTION AT THE EXTERIOR OF THE BUILDING. 7 ACCESSIBLE GUESTROOM VISUAL UNIT WITH 177 AND 15 CANDELA RATING IN HEARING IMPAIRED AND/OR ACCESSIBLE GUESTROOM AS PER NFPA 72 2013 TABLE 18.5.5.7.2. 8 CONTRACTOR TO PROVIDE VOICE EVACUATION SYSTEM AS A PART OF FIRE ALARM SYSTEM IN ACCORDANCE TO NFPA 72 TABLE-A.18.4.3 CONSIDERING AVERAGE AMBIENT SOUND LEVEL OF 55d BA. LEGENDS CS COMBINATION OF PHOTOELECTRIC SMOKE/CO DETECTOR, SURFACE MOUNTED SD PHOTOELECTRIC SMOKE DETECTOR, SURFACE MOUNTED 520 SD PHOTOELECTRIC SMOKE DETECTOR WITH SOUNDER BASE, WALL MOUNTED 520 CS COMBINATION OF PHOTOELECTRIC SMOKE/CO DETECTOR,WITH SOUNDER BASE, WALL MOUNTED �F COMBINATION AUDIAUVISUAL FIRE ALARM SYSTEM INDICATING DEVICE © MANUAL FIRE ALARM PULL STATION, MOUNTED @ 48" AFF V� VISUAL FIRE ALARM SYSTEM INDICATING DEVICE -131 FIRE SMOKE DAMPER, F&SD RF RADIO RESPONDER, SURFACE MOUNTED ® I TWO-WAY COMMUNICATION SP LOW VOLTAGE SPEAKER, CEILING MOUNTED BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.cpm RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF QP�.'\ siEHh e' cT%p m N 1 12 o ATE a OF �gBrONAL ��` DATE: 2NEDs.04 GARRY VERMAAS. Phl HE Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 FAO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY AM CHECKED BY GWV PROJECT NO B4-134-1705 SHEET NAME 4TH FLOOR FIRE ALARM PLAN DRAWINGS NO. FA=204