Loading...
HomeMy WebLinkAboutFA-301 - TYPICAL FIRE ALARM RISER DIAGRAMRF RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel ((�� `�vmlUtlenrJnIX1�L x DATE: 07/22/19 SEQUENCE OF OPERATION ' SOME SYSTEM AND INPUTS MAY NOT BE APPLICABLE TO THIS PROJECT. " IT IS NOT THE INTENT TO REPROGRAM THE PANEL, SEQUENCE SHOWN FOR REFERENCE ONLY SYSTEM OUTPUTS GENERAL NOTES: y REFERENCE NUMBERS ARE SHOWN IN PARENTHESIS (1)FOR "NOTES/ NOTATIONS" INDICATED BELOW AND IN HEADINGS TO THE RIGHT. O? p� 4' Ci' $y yy y FIRE ALARM SYSTEM DEVICES ARE POINT ADDRESSABLE. � V`Z' yng b�F ON CAMPUS STYLE PROPERTIES, PROVIDE POINT ADDRESSABLE Q� py� u 4y p`7 y3 y� QY INTELLIGENT NETWORKING REPORTING TO CONTINUOUSLY ATTENDED PROPERTY LOCATION. 2yO �yzyy JQ4 y0� SPRINKLER SYSTEM WATER FLOW AND TAMPER SWITCH ALARMS ARE ANNUNCIATED ON THE FACE. �algy0 y�y SYSTEM INPUTS A B C D E IF IG H 111 1 1111 J K L M N FACE: DISPLAYAN AUDIBLE /VISUALALARM. REMOTE ANNUNCIATOR: DISPLAY AN AUDIBLE VISUAL ALARM. AUDIBLE / VISUAL ALARMS: ACTIVATE AUDIBLE / VISUAL STROBE • • • APPLIANCES ON AFFECTED FLOOR. ASSEMBLY DOORS AND FIRE DOORS: RELEASE MAGNETIC DOOR . . . HOLDERS ON AFFECTED FLOOR. STAIRWELL PRESSURIZATION: AUTOMATICALLY ACTIVATE PRESSURIZATION. SMOKE EXHAUST: AUTOMATICALLY ACTIVATE EXHAUST SYSTEM IN AFFECTED ZONES. (4) (4) GUESTROOM AUDIBLE ALARMS: ACTIVATE ALARMS IN ROOMS ON . . . . . . AFFECTED FLOOR. GUEST ROOMS AUDIBLE / VISUAL SIGNALS: ACTIVATE BOTH SIGNALS • • IN HEARING IMPAIRED GUEST ROOMS ON AFFECTED FLOOR. LOCAL AUDIBLE ALARMS: ACTIVATE AUDIBLE ALARMS ONLY IN ROOMS CONTAINING ALARM. (6) GUESTROOM LOCAL AUDIBLE / VISUAL SIGNALS: ACTIVATE BOTH SIGNALS ONLY IN HEARING IMPAIRED GUESTROOM CONTAINING ALARM. (6) AIR HANDLERS: AUTOMATICALLY SHUT OFF ASSOCIATED AIR HANDLERS. COOKING AREA GAS / ELECTRIC: AUTOMATICALLY SHUT OFF ASSOCIATED COOKING LINE GAS & ELECTRIC AND MAKEUP AIR HANDLER. ELEVATOR PHASE 1 DESIGNATED LEVEL AND ALTERNATE LEVEL . RECALL, PHASE 2 FIREFIGHTERS IN CAR OPERATION. A B C O E F G H I J K L M N NOTES/NOTATIONS : (1) SYSTEM SMOKE SENSORS NOT LOCATED IN GUEST ROOMS. (2) PROVIDE ELEVATOR PHASE 1 DESIGNATED LEVEL AND ALTERNATE LEVEL RECALL, SHUNT TRIP FUNCTION AND PHASE 2 FIREFIGHTERS' IN -CAR OPERATION IN COMPLIANCE WITH ASME A17.1, ELEVATOR CODE. (3) GUESTROOM SMOKE SENSORS: PROVIDE PHOTOELECTRIC TYPE, WITH SOUNDER BASE ( MINIMUM RATINGS OF 851 "AT THE PILLOW". IN SUITES, MULTIPLE SENSORS SHALL ACTIVATE SIMULTANEOUSLY. (4) EXCEPT ON GUESTROOM FLOORS WATER FLOW ALARMS SHALL NOTACTIVATE SMOKE CONTROL EXHAUST FANS WHERE SMOKE CONTROLZONES DO NOT CORRESPOND. (5) FIRE ALARMS SHALL ACTIVATE ONLY ON FLOOR OF ALARM. GOVERNING AUTHORITY MAY REQUIRE ADDITIONAL ZONING. (6) CARBON MONOXIDE DETECTORS IN GUEST ROOMS, PUBLIC AND BOH AREAS SHALLACTIVATE AN ALARM IN THE GUESTROOM AND ROOMS OF INCIDENTAND AT THE FIRE ALARM CONTROL PANEL. (7) HEAT DETECTORS ARE NOT RECOMMENDED SINCE FIRE SPRINKLERS SERVE THE SAME FUNCTION. (8) PROVIDE 'FIRE PUMP RUN' AND 'FIRE PUMP FAULTY" SUPERVISORY SIGNALS FROM CONTROLLER TO THE FACE, AS A MINIMUM. (9) PROVIDE -GENERATOR RUN"AND"GENERATOR FAULT" SUPERVISORY SIGNALS TO THE FACE. FIRE ALARM SYMBOLS FACP FIRE ALARM CANTROL PANEL FAAP REMOTE ANNUNCIATOR EXP CIRCUIT EXPANDER PANEL © MANUAL FIRE ALARM PULL STATION, MOUNTED @ 48" AFF DUCT DETECTOR ADD r HORN/STROBE MULTI Oct SD WALL MOUNTED SMOKE DETECTOR O HEAT DETECTOR © COMBINATION OF SMOKE/CO DETECTOR O HEAT DETECTOR TAMPER SWITCH BY OTHERS TWC TWO WAY COMMUNICATION SD SMOKE DETECTOR WITHOUT SOUNDER BASE © — CARBON MONOXIDE DETECTOR, CEILING MOUNTED CS WALL MOUNTED SMOKE/CS DETECTOR 177etl m VISUAL FIRE ALARM 520 SD SMOKE DETECTOR WITH LOW FREQUENCVSOUNDER BASE LOW VOLTAGE SPEAKER, CEILING MOUNTED ATYPICAL FIRE ALARM RISER DIAGRAM 1211 = 11.011 (1) FIRE ALARM SCHEMATIC RISER DIAGRAM IS TYPICAL AND FOR REFENCE ONLY. THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS OF THE PROPOSED PONIT ADDRESSABLE FIRE ALARM SYSTEM, INCLUDING ALL DEVICES AND WIRING LAYOUTS TO THE FIRE MARSHALL FOR APPROVAL PRIOR TO PURCHASING OR INSTALLING ANY ROUGH -IN BEFORE SUBMITTING TO THE ENGINEER FOR REVIEW, THE ENGINEER W ILLPROVIDE CAD DRAWING OF FLOOR PLANS FOR SHOP DRAWING PREPARATION ON REQUEST. ANY REVISIONS OR ALTERATIONS TO THE SYSTEM REQUIRED BYTHE LOCAL JURISDICTION PRIOR TO OBTAINING CERTIFICATE OF OCCUPANCY OBTAINING CERTIFICATE OF OCCUPANCY WILL NOT BE REASON FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR. (2) DETECTION DEVICES ARE EQUIPPED THROUGHOUT GUEST ROOM CORRIDORS, AT SPACING NOT TO EXCEED 40 FEETS ON CENTER, PUBLIC AREAS, SERVICE AREAS, (WHERE APPLICABLE) AND MECHANICAL AREAS. DETECTORS ARE REQUIRED FOR ALL STORAGE ROOMS MORE THAN 150 SQUARE FEET. (3) CONTRACTOR SHALL PROVIDE A COMPLETE, OPERATIONAL POINT ADDRESSABLE TYPE FIRE ALARM SYSTEM IN ACCORDANCE WITH ALL CODE, FRANCHISE, AND MANUFACTURING REQUIREMENTS, INCLUDING DEVICES REQUIRED BY LOCAL CODE BUT NOT INDICATED HEREIN. SYSTEM SHALL INCLUDE ALL CONNECTIONS TO FLOW AND TAMPER SWITCHES AS WELL AS P.I.V., AND DUCT SMOKE DETECTORS FOR MECHANICAL UNITS. (4) FIRE ALARM CONTRACTOR TO ENDURE THAT THE HEAT DETECTORS NEED TO BE PLACED WITHIN 24 INCHES OF ANY SPRINKLER HEADS IN THE ELEVATOR ROOM IF THEY ARE BEING USED TO TRIGGER ELEVATOR SHUTDOWN PER SECTION 21.4.2 OF NFPA 72. (5) PHOTOELECTRIC LOW VOLTAGE SMOKE DETECTOR WITH LOW FREQUENCY SOUNDER BASE IN ALL GUEST ROOMS SHALL BE EQUIPPED WITH ANNUNCIATOR DEVICE AS REQUIRED.GUEST ROOM ALARM SHALL PROVIDE INDIVIDUAL ALARM WITHIN GUEST ROOMONLV. A SEPARATE SYSTEM NOTIFICATION DEVICE SHALL BE ACTIVATED UPON GENERAL FIRE ALARM. DEVICES WITHIN STANDARD GUEST ROOMS SHALL BE SYSTEM DETECTORS WITH LOW FREQUENCY SOUNDER BASE. IN ACCESSIBLE AND HEARING IMPAIRED ROOMS, AN ADA HORN/STROBE SHALL BE PROVIDED, WITH AN ADDITIONALSTROBE IN THE BATH. (6) FIRE ALARM VENDOR SHALL PROVIDE FIRE ALARM RISER DIAGRAM IN SHOP DRAWINGS FOR REVIEW BY BASE4 (7) CONTRACTOR SHALL PROVIDE LOW FREQUENCY SOUNDER STROBE IN EACH GUEST ROOM AS PER HILTON FIRE PROTECTION AND LIFE SAFETY BRAND STANDARD. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.com RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF QP��'\si EHh� e' %p m N 1 12 a F PI �gBrONAL ��` DATE W180304 GARRY VER I Phi PE Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HI TOM CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 FAD 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY AM CHECKED BY GWV PROJECT NO, B4-134-1705 SHEET NAME TYPICAL FIRE ALARM RISER DIAGRAM DRAWINGS NO. FA=301