Loading...
HomeMy WebLinkAboutFP-103 - 3RD FLOOR FIRE SPECIFICATION PLAN1 2 3 3.1 4 I I I I I K I I I I I I I I I I I j sTaR#2 2 - -. TEST AND VALVE ASSEMBLY BUTTERFLY VALVE LANDINGVALVE I � 4"STAND — E PIPE UP — PRESSURE GUAGE FIRE 3RDI FLOW DETECTOR] 'gyp SWITCH -- — - — — U I I RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel ((�� `�a G'UBnolNDAaL x DATE: 07/22/19 CUSTOM KING ONE NEDROOM I CC. KING STUDIO I CONNECTING t302 I — — I I KING STUDIO 303 KING STUDIO — CONNECTING 304 _ QUEEN/ QUEEN STUDIO 305 _KING STUDIO 306 QUEEN/ QUEEN STUDIO 307 11 12 13 14 15 16 17 18 100 19 20 21 I I I I I I I I I I I I I I I I I I I I I I I I ACC. ^G I QUEEN/ I QUEEN/ I KING KINGQUEENF ONE QUEEN/ QUEEN QUEEN KING KING STUDIO BEDROOM STUDIO STUDIO STUDIO STUDIO CONNECTING STUDIO CONNECTING CONNECTI G ONNECTING 309 I 311 13 I 3I I I 315 317 319 I 321 0 - I I I 1STORAGE O • • O 331 FLOW DETECTOR SWITCH ,— PRESSURE I CORR. FIRE SPRINKLER MAIN TO GUAGE 3RD FLOOR SPRINKLERS 300 4"STAND L. PIPE UP IF ---- — ICE-- • [EL1IDF/ ELECTRICALKING KING KING ELEVATOR2STUDIO STUDIO STUDIO LOBBY 308 310 312 327 HO SEKEEPING I I I 3 0 �I LANDING VALVE -- BUTTERFLY !VALVE -i TEST AND VALVE ASSEMBLY ST 1 380 I I I I —__—_r_—_ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 8 9 10 11 12 13 14 15 16 17 18 100 19 20 21 ,J 0 3RD FLOOR FIRE SPECIFICATION PLAN 1/811 = 1'-011 L �NI I p�71 �� KING LEI I .• o• I IIDy�I .• LBI I I . a .• o• I IiC11I "K I I G� D• —STU.• q � �1 FIRE PROTECTION AREA COVERAGE FLAG NOTE 1 PROVIDE ORDINARY HAZARD GROUP 1 OCCUPANCY COVERAGE WITH DENSITY OF 0.15 GPM PER SQ.FT. FOR 1500 SQ.FT. HYDRAULICALLY MOST REMOTE AREA. MECHANICAL ROOM, ELECTRICAL ROOM, KITCHEN, STOREGE ROOMS ARE UNDER ORDINARY HAZARD CLASSIFICATION PROVIDE LIGHT HAZARD OCCUPANCY COVERAGE WITH DENSITY OF 0.10 GPM PER SQ.FT. FOR 1500 SQ.FT. HYDRAULICALLY MOST REMOTE AREA. ALL GUEST ROOMS, COORRIDORS, MEETING ROOMS & PUBLIC TOILET ROOMS ARE UNDER LIGHT HAZARD CLASSIFICATION BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00rn RICARDO J. MUNIZ-GUILLET, All 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF PP��'\ST EHh e. %p m N 1 12 o ATE OF �gBrONAI E�` DATE: 20180304 OARRY Willi PhD. PE Owner: Q� �1 THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY MILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO. DELTA I ISSUED DATE DESCRIPTION 1 FPO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SPB CHECKED BY GWV PROJECT NO, 134-134-1705 SHEET NAME 3RD FLOOR FIRE SPECIFICATION PLAN DRAWINGS NO. FP-103