Loading...
HomeMy WebLinkAboutG-003 - CODE SUMMARYCODE SUMMARY- 2014 INDIANA BUILDING CODE PROJECTINFO PROJECT ADDRESS: HILTON HOME2 SUITES, CARMEL 12W OLD MERIDIAN ST, INDIANA 46032 CONSTRUCTION SUMMARY: NEW CONSTRUCTION OF A FULLY SPRINKLERED (5) STORY (PODIUM AND 12" HEAVY DUTY PLANK WITH A CONCRETE TOPPING SUPPORTED BY ICE WITH WOOD FRAMING ON UPPER FLOORS) CODE DATA APPLICABLE CODES BUILDING CODE: IBC- INDIANA BUILDING CODE 2014 ACCESSIBILITY CODE: 2014 INDIANA BUILDING CODE ACCESSIBILITY, 11TH EDITION ELECTRIC CODE: IEC- INDIANA ELECTRICAL CODE 2009 PLUMBING CODE: IPC- INDIANA PLUMBING CODE 2012 MECHANICAL CODE: IMC. INDIANA MECHANICAL CODE 2014 FIRE CODE: IFC-INDIANA FIRE CODE 2014 FUEL GAS CODE: IFGC- INDIANA FUEL GAS CODE 2014 ENERGY CONSERVATION CODE: IECC- INDIANA ENERGY CONSERVATION CODE 2010 CHAPTER 3: USE AND OCCUPANCY CLASSIFICATION MAIN OCCUPANCY: R-1 GROUP R-1: RESIDENTIAL HOTEL ROOMS GROUP A-2: ASSEMBLY LOBBY/LOUNGE GROUP A-3: FITNESS FITNESS ROOM GROUPS: BUSINESS OFFICE AREAS GROUP S-1: STORAGE STORAGE SECTION 420 GROUPS 1-1. R-1. R-2. R-3 AND R4 420AGeneral. Occupancies in Groups 1-1, R-1, R-2, R-3 and R4 shall comply with the provisions of Sections 420.1 through 420.6 and other applicable provisions of this code. 420.28eparation walls. Walls separating dwelling units in the same building, walls separating sleeping units in the same building and walls separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as fire partitions in accordance with Section 708 420.31-lorizantal separation. Flom assemblies separating dwelling units in the same buildings, floor assemblies separating sleeping units in the same building and floor assemblies separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as horizontal assemblies in accordance with Section 711. CHAPTER 6: TYPES OF CONSTRUCTION CONSTRUCTION TYPE: 5A AND 1A TABLE 601: FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) ELEMENT 5A RATING 1A RATING STRUCTURALFRAME 1HR 1HR BEARING WALLS EXTERIOR 3HR 1HR BEARING WALLS INTERIOR 1HR 1HR NON -BEARING WALLS& PARTITIONS EXTERIOR 1HR 1HR NON -BEARING WALLS & PARTITIONS INTERIOR 1HR IHR FLOOR CONSTRUCTION 3HR 1HR ROOF CONSTRUCTION 1HR 1HR SECTION 601 EXCEPTION STATES THAT APPROVED AUTOMATIC SPRINKLER SYSTEM CANNOT BE USED FOR A REDUCTION IN RATING IF IT HAS ALREADY BEEN USED FOR AN AREA INCREASE OR AN ALLOWABLE HEIGHT INCREASE. IT ALSO STATES THAT IT CANNOT BE USED FOR A REDUCTION IN BEARING WALLS CHAPTER 5: GENERAL BUILDING HEIGHTS AND NO. OF STORIES: 5 BUILDING HEIGHT: 55'41 1/2" TO ROOF DECK ACTUAL BUILDING HEIGHT BUILDING HEIGHT=55'-111/2" TALLEST PARAPET= 9'-111/4" 66-103/4" TOTAL BUILDING HEIGHT TABLE 503: ALLOWABLE BUILDING HEIGHT TYPE (5A) CONSTRUCTION GROUP R-1: HEIGHT (5) STORIES, 75'0" (SPRINKLER) TABLE 503: ALLOWABLE BUILDING AREA GROSS BUILDING AREA: GROSS AREA LEVEL AREA TYPE (5A) AND (1 A)CONSTRUCTION. ALLOWABLE AREA BY CODE GROUP R-1: AREA (TYPE 5A) = 32,000 SO FT SECTION 506: BUILDING AREA MODIFICATIONS Sore 1 ranaral. Tha lomirinn nrcan limactl nv Tnhlc 5n3 shall be permittetlto be increased due to frontage (I/) and RELEASED FOR CONSTRUCTION th the following: Subject to compliance with all regulations of State and Local Codes City of Camel y n kR.wlidR'S71= N DATE: 07/22/19 CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES 708.31Fire-resistance rating. Fire partitions shall have a fire -resistance rating of not less than 1 hour. Exceptions: 1.Corridor walls Permitted to have a 112-hour fire -resistance rating by Table 1020.1. 2.Dwelling unit and sleeping unit separations in buildings of Type 118, HIS and VB construction shall have fire - resistance ratings of not less than 112 hour in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. 717.3 Draftstopping in floors. In combustible construction, Draftstopping shall be installed to subdivide floodceiling assemblies in the locations prescribed in Sections 717.3.2 through 717.3.3. Exceptions: 1. Draftstopping Is not required In buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. CHAPTER 9: FIRE PROTECTION SYSTEMS AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS SPECIFIED FOR THIS PROJECT STANDPIPES WILL BE USED SECTION 903: AUTOMATIC SPRINKLER SYSTEMS AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION 903 903.2.11.4Ducts conveying hazardous exhausts. Where required by the Florida Building Code, Mechanical, automatic sprinklers shall be provided in duds conveying hazardous exhaust, or flammable or combustible materials. Exception: Ducts where the largest crossHmctional diameter of the duct is less than 10 inches (254 men). SECTION 906 PORTABLE FIRE EXTINGUISHERS 906.1 W here required. Portable fire extinguishers shall be installed in all of the following locations: 1.1n Group A, B, E, F, H, I, M, R-1, R-2, R4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified In Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-13:C. 2.Within 30 feet (9144 ram) of commercial cooking equipment. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with the Florida Fire Prevention Code. 5.Where required by the Florida Fire Prevention Code. 6.Special-hazard areas, including but not limited to laboratories, computer roams and generator roams, where required by the fire code official. Table El 906.1 Additional Required Portable Fire Extinguishers in the Florida Fire Prevention Code. Reserved. 906ACooking grease fires. Fire extinguishers provided farthe protection of cooking grease fires shall be of an approved type compatible with the automatic fire -extinguishing system agent and in accordance with the Florida Fire Prevention Code. 907.2.8Group R-1. Fire alarm systems and smoke alarms shall be installed in Group R-1 occupancies as required in Sections 907.2.8.1 through 907.2.8.3. CHAPTER 10: MEANS OF EGRESS SECTION 1004: OCCUPANT LOAD In determining means of egress requirements, the number of occupants for whom means of egress facilities are provided shall be determined in accordance with this section MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT GROUP R-1: RESIDENTIAL(HOTEL) 200 SF GROSS GROUP A: ASSEMBLY 15 SF NET POOL 50 SF GROSS (OUTDOOR POOL NOT INCLUDED IN OCCUPANCY LOAD CALCULATIONS) POOLDECK 15 SF GROSS (OUTDOOR POOL NOT INCLUDED IN OCCUPANCY LOAD CALCULATIONS) KITCHEN 200 SF GROSS FITNESS 50 BE GROSS INDUSTRIAL 100 SF GROSS MERCANTILE 60 SG GROSS GROUP B: BUSINESS 100 BE GROSS GROUP S-2:STORAGE 300 BE GROSS SECTION 1005: EGRESS WIDTH 1005.3.1 Stairways The capacity, in inches, of means of egress stairways shall be calculated by multiplying the occupant load served by such stairways by a means of egress capacity factor of 0.3 inch ITS ram) per occupant. Where stairways serve more than one story, only the occupant load of each storyconsidered individually shall be used in calculating the required capacity of the stairways serving that story. Exceptions: 1.For other than Group H and 1-2 occupancies, the capacity, in inches, of means of egress stairways shall be calculated by multiplying the occupant load served by such stairways by a means of egress capacity factor of 0.2 inch (5.1 ram) per occupant in buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2 and an emergency voice/alarm communication system in accordance with Section 907.5.2.2. 2.Facilities with smoke -protected assembly seating shall be permitted to use the capacity factors in Table 1029.6.2 indicated for stepped aisles for exit access or exit stairways where the entire path for means at egress from the seating to the exit discharge is provided with a smoke control system complying with Section 909. 3.Facilities with outdoor smoke -protected assembly seating shall be permitted to the capacity factors in Section 1029.6.3 indicated for stepped aisles for exit access or exit stairways where the entire path for means of egress from the seating to the exit dischame is open to the outdoors. OCCUPANT LOAD-1 ST FLOOR AREA OCCUPANT LOAD FACTOR OCCUPANT LOAD EGRESS WIDTH EGRESS WIDTH REQUIRED A-2 3068 SF 1 15 1 205 1 0.2 41 A-3 638 SF 1 50 1 13 1 0.2 3 B 13255 SF 1 100 1 133 1 0.2 27 S-1 3553 SF 300 12 0.2 2 20513 SF 362 72 OCCUPANT LOAD-BAR/BENCH & BOOTH SEATING LENGTH FACTOR OCCUPANT LOAD FACTOR OCCUPANT LOAD EGRESS WIDTH EGRESS WIDTH REQUIRED BAR SEATING 362LF 11 PERSON/18" 1 21 1 0.2 1 4.2 BOOTH SEATING 232 1 PERSON/24" 1 10 1 0.2 1 2 TOTAL SEATING 31 6.2 EGRESS WIDTH EGRESS WIDTH REQUIRED: = 362+31 X 0.2 = 57.4 = 78" PROVIDED: _ (36" X 3) + (72" X 1) EXITS = 180" OCCUPANT LOAD- POOL AREA AREA OCCUPANT LOAD FACTOR OCCUPANT LOAD EGRESS WIDTH EGRESS WIDTH REQUIRED POOL 1937 SF 50 37 0.2 7 1837 SF 37 7 EGRESS WIDTH REQUIRED: = 98 X 0.3 = 30.6 = 20" EGRESS WIDTH PROVIDED : = 36" X 1 EXITS = 36" OCCUPANCY LOAD -TYPICAL UPPER FLOOR AREA OCCUPANT LOAD FACTOR OCCUPANTLOAD EGRESS WIDTH EGRESS WIDTH REQUIRED B 2100 Ste 100 21 0.2 4 R-1 9581 SF 200 48 0.2 10 S-1 526 SF 300 2 0.2 0 122W SF 71 14 EGRESS WIDTH REQUIRED: = 71 X 0.2 = 14.2 = 15" EGRESS WIDTH PROVIDED : = 36" X 2 EXITS = 72" PROVIDE EGRESS ILLUMINATION PER SECTION 1006 SECTION 1013: EXIT SIGNS PROVIDE EXIT SIGNS PER SECTION 1013 SECTION 1017: EXIT ACCESS TRAVEL DISTANCE TABLE 1017.1: EXIT ACCESS TRAVEL DISTANCE OCCUPANCY WITHOUT SPRINKLER SYSTEM WITH SPRINKLER SYSTEM R-1 200 FT 250 FT SECTION 1021: NUMBER OF EXITS AND CONTINUITY TABLE 1021.1: MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD TOTAL OCCUPANTS: 1-500 18T FLOOR 2ND -4TH FLOOR TOTAL EXITS REQUIRED: 2 2 TOTAL EXITS PROVIDED: 3 2 1101.1.1Criteria. Buildings shall be designed and constructed in accordance with the Florida Building Code, Accessibility. REFERENCED ACCESSIBILITY 2014 INDIANA BUILDING CODE ACCESSIBILITY, CODE: CHAPTER11 [a3:L1911 q:irF'n 14L9.11 L,[H A E4k ill TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES CLASSIFICATION OCCUPANCY WATER CLOSET LAVATORIES DRINKINGFOUNTAINS OTHER ASSEMBLY(A-2)A-3 MALE FEMALE MALE FEMALE 1 PER 125 1 PER 65 1 PER 200 1 PER 500 1 PER 500 1 Service Sink remainder exceeding 50 RESIDENTIAL(R-1) R-1 1 per Sleeping units 1 per Sleeping units - STORAGE (S-2) S-2 1 PER 100 1 PER 100 1 PER 1,000 CALCULATIONS 1 PER GUESTROOM ASSEMBLY 205OCCUPANTS .(102MALE/102FEMALE) WATER CLOSETS MALE: 1.363 REQUIRED FEMALE :1.363 REQUIRED LAVATORIES MALE: 0.511 REQUIRED FEMALE:0.511 REQUIRED STORAGE 12 OCCUPANTS-(3 MALE/3FEMALE) WATER CLOSETS MALE: 0.059 REQUIRED FEMALE: 0.059 REQUIRED LAVATORIES MALE: 0.059 REQUIRED FEMALE :0.059 REQUIRED FITNESS 13 OCCUPANTS (6 MALE/7 FEMALE) WATER CLOSETS MALE :0.051 REQUIRED FEMALE: 0.085 REQUIRED LAVATORIES MALE:0.031 REQUIRED FEMALE: 0.031 REQUIRED DRINKING FOUNTAINS 1 REQUIRED SERVICE SINK 1 REQUIRED BUSINESS 133 OCCUPANTS -(66 MALE 166 FEMALE) WATER CLOSETS MALE: 2.65 REQUIRED FEMALE :2.65 REQUIRED LAVATORIES MALE: 1.656REQUIRED FEMALE :1.656 REQUIRED DRINKING FOUNTAINS 1 REQUIRED SERVICE SINK 1 REQUIRED ENERGY CODE INFORMATION REFERENCED ENERGY CODE: INDIANA ENERGY CONSERVATION CODE CHAPTERS 2010 301.1 CLIMATE ZONE HAMILTON COUNTY SA CHAPTERS COMMERCIAL ENERGY EFFICIENCY CLIMATE ZONE _ SECTION 502.1 ROOF INSULATION ENTIRELY ABOVE DECK R-30d WALLS- ABOVE GRADE (WOOD FRAMED WALLS) R-13Cavgy+R-3.8ci WALLS -BELOW GRADE- FOUNDATION& ELEV. PIT R-7.5 SLAB ON GRADE FLOORS- UNHEATED R-10 FOR 24" below OPAQUE DOORS (NON SWINGING) R-4.75 ENTRY DOORS U-.0.77 FIXED FENESTRATION- STOREFRONT GLAZING U-0.38 OPERABLE FENESTRATION (GR WINDOWS) U-0.45 ENTRANCE DOORS (SLIDING FRONT DOOR) U-0.77 1 Service Sink 1 Service Sink WATER CLOSETS MALE A.51 REQ'D = 5 PROVIDED FEMALE :5.385 READ = 6 PROVIDED LAVATORIES MALE :2.50 REO'D = 3PROVIDED FEMALE:2.58 REQ'D =3PROVIDED DRINKING FOUNTAINS 0 REQ'D = 1 PROVIDED SERVICE SINK 1 REQ'D 1 PROVIDED NOTE: THIS EXCERPT IS ONLY A PORTION OF THE ENLARGE CODE REQUIREMENTS. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL RELATED CODE SECTIONS TO RESULT IN FULL AND COMPLETE CODE COMPLIANCE. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.com RICARDO J. MUNIZ-GULLIET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 Seal: j11MU.. ,0 ```"0. Do TE 1p 17oo161 - OF . DIANP. •\;�� ' 'u/CHITI�G41`�. Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513.623.9430 HOME SUITES BY HILTON TM CARMEL,INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 DECOR PACKAGE: TRIBECA ISSUE NO. DELTA ISSUE DATE I DESCRIPTION 1 JAD j2DI9JD3JD4 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY NP CHECKED BY NIL PROJECT NO. B4-134-1705 SHEET NAME CODE SUMMARY DRAWINGS NO. G=003