HomeMy WebLinkAboutLT-101 - LIGHTING DETAILS-1BOLT TO ANCHORTO STRUCTURAL MEMBER CEILING SLACK SAFETY CABLE LIGHT FIXTURES OO FOR EXPOSED LED LIGHT BULBS OR FIXTURE LENSES SUBJECT TO FALLING, SECURE IN PLACE WITH 2 WIRES THAT WRAP BENEATH THE LENS OR BULB AND ATTACH SECURELY TO THE FIXTURE. SURFACE MOUNTED FIXTURE SUPPORT NOT TO SCALE STRUCTUR E ABOVE SWIVEL ALIGNED TO ALLOW FIXTURE TO SWING 45 FRON VERTICAL IN ALL DIRECTION III PIPE HANGER AND ALIGNER, TWO PER FIXTURE �1/8' AIRCRAFT SAFETY CABLE, FIXTURE SUPPORT WIRE, 2-PER 4 FOOT LENGTH OF FIXTURE, SECURE SECURE LIGHT FIXTURE SUPPORT TO BUILDING SIMILAR TO CEILING SUPPORT WIRES WIRES TO MOUNTING TABS, IF LIGHT CABLE TO BE SLACK TO ALLOW FIXTURE TO MOVE FIXTURE IS NOT FURNISHED WITH 45 FROM VERTICAL. MOUNTING TABS PROVIDE 2 -'EYE' BOLTS WITH ALL NECESSARY HARDWARE. MINIMUM 4 TIGHT TURNS. INDUSTRIAL FIXTURE MOUNTING DETAIL � NOT TO SCALETO SCALE NOTE: 1. INSTALL REMOTE TEST MONITOR MODULE IN A SINGLE GANG BOX. 2. MOUNT EMERGENCY BATTERY PACK ON TOP OF THE FIXTURE HOUSING ON AN ADJACENT WALL OR ON BUILDING STRUCTURAL MEMBERS. IT SHALL NOT BE MOUNTED TO MECHANICAL EQUIPMENT OR THE SUSPENDED CEILING SYSTEM. 3. IF SUSPENDED CEILING EXISTS, CENTER REMOTE TEST / MONITOR MODULE IN ADJACENT CEILING TILE. 4. LOCATE REMOTE TEST / MONITOR MODULES IDENTICALLY SO THAT THEY FORM A STRAIGHT LINE WHEN VIEWED FROM THE END OF CORRIDOR ROOM 5. RECESSED LIGHTING FIXTURE ARE INSTALLED IN RATED FLOOR/CEILING ASSEMBLY. rtLBELOW SUSPENDED� CEILING CEILING GRID SUSPENDED CEILING (SEE NOTE 3) EMERGENCY BATTERY PACK ABOVE CEILING REMOTE TEST / MONITOR MODULE. CENTER IN TILE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations EMERGENCY LIGHTING FIXTURE of State and Local Codes City of Camel ((�� �vmlUtlenrJnw�L x DATE: 07/22/19 A. PROVIDE POWER TO EXIT LIGHT W ITH 2412 + 14 12 GROUND. ( EXISTING CEILING OR WALL. PROVIDE GROUNDED BOX FOR MOUNTING. HEAVY-DUTY ANCHORS. 0 JUNCTION BOX COVER PLATE. 2 ITYPICAL EXIT SIGN MOUNTING DETAIL NOT TO SCALE 5 ICOEE LIGHT MOUNTING DETAIL MOUNTING DETAIL NOT TO SCALE SCALE WALL 8 IWALL MOUNTING DETAIL WEATHERPROOF BUSHING LED WALL PACK FIXTURE SEE FIXTURE SCHEDULE 50' CABLE (2-#12+GND), IF FIXTURE COMES EQUIPPED WITH 'SO' CABLE, OR LIQUID -TIGHT FLEX CONDUIT W /2-#12+GND NOTE 1. CONTRACTOR SHALL PROVIDE HARD WIRE CONNECTION FOR WALL PACK LIGHT NOT PLUG OUTLET. 2. CONTRACTOR SHALL USE MC CABLE CHORD FOR LED WALL PACK LIGHT CONNECTION. PLEASE SEE BELOW, NEC SECTION 225.10.330.10. BUILDING STRUCTURE O O SUSPENDED 3 I RECESSED MOUNTED FIXTURE SUPPORT O�Al YYNBI9Y_FYI.Igelp1-1111Be]N[H-Y1:11INPIYq DIAGONALLY OPPOSITE CORNERS. ANCHOR TO STRUCTURE MEMBER IN APPROVED FASHION SEISMIC SUPPORT DETAIL RECESSED FIXTURE SUPPORT DETAIL v I an..n cnAi c LIGHT GFCI BREAKER MUST HAVE GFCI PROTECTION IF IN SAME RACEWAY WITH UNDERWATER LIGHT CONDUCTORS PUMP 9 IPOOL LIGHT TRANSFORMER ANY CONDUCTORS SHARING TRANSFORMER ENCLOSURE OR RACEWAY TO LIGHT OR JB MUST BE GFCI PROTECTED. TRANSFORME R ENCLOSURE CONNECTS TO EQUIPOTENTIAL GRID FORMING SHELL BONDING LUG (POTTING COMPOUND REQUIRED HERE). #8 BONDING WIRE CONNECTS HERE AND RUNS TO DECK BOX. LIGHT GFCI BREAKER Deck Box RECESSED DOWNLIGHT METAL FORMING SHELL WITH COILED LAMP CORD TO ALLOW LAMP TO BE CHANGED ABOVE WATER ON POOL DECK. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QP��'\si EHh� e' %p m N 1 12 o ATE 9O . 01I PNP:'2b �g"rONAL DATE: 20180304 OARRY VERMMe. Phi PE Owner: t� �1 THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 LO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY MSM CHECKED BY GWV PROJECT NO. 64-134-1705 SHEET NAME LIGHTING DETAILS-1 DRAWINGS NO. LT-101