Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LT-209 - TYPICAL UNIT LIGHTING PLAN-2
GENERAL NOTES: 1. REFER TO ARCHITECTURAL/ID DRAWINGS FOR EXACT DIMENSIONS AND HEIGHT. 2. REFER TO SHEET LT-002A<-002B FOR LIGHTING FIXTURE SCHEDULE. 3. ALL LIGHT SWITCHES IN GUEST ROOMS SHALL BE ROCKER SWITCHES. 4. ALL SWITCHES IN GUEST ROOM TO BE MOUNTED AT 46"A.F.F. TO CENTER UNLESS OTHERWISE NOTED. 6. PROVIDE MASTER SWITCH AT GUEST ROOM ENTRY DOOR TO CONTROL ALL PERMANENTLY INSTALLED LIGHT FIXTURES AND SWITCHED RECEPTACLES IN ACCORDANCE WITH THE ENERGY CODE. 6. ALL SWITCHES IN BATHROOM EQUIPPED WITH NIGHTLIGHT AND"LITE-A- SWITCH' LED BACKLIT FACEPLATE, UNIVERSAL SERIES CLEAR SWITCH WITH PLATE MAINTAIN 2" DISTANCE FROM ALL OTHER DEVICES. 7. REFER TO SHEET E-209 & E-210 FOR LIGHTING PANEL AND PANEL SCHEDULE FOR LIGHTING LOADS. 8. CONTRACTOR SHALL ENSURE THAT NO NEED TO PROVIDE SWITCH AS EXHAUST FAN IS USED IN BATHROOM AREA. LT-209 KEY NOTES ® Text IR THAT CONTROLS ALL PERMANENTLY WIRED LUMINARIES AND RECEPTACLES, EXCEPT THOSE IN THE BATHROOM AS PER 2010 ERGY CONSERVATION CODE BASED ON ASH RAE 90.1.2007. ROOMS. 4 IDOOR BELL SHUTT OFF SWITCH MOUNTED AT 46" A.F.F. OCCURS IN HEARING AND SHOULD HAVE INDIVIDUAL BUILT-IN TCHES. CONTRACTOR VERIFY EFERNPO CONNECTION FOR HEADBOSHEET ARD 9LIGHTS OW WITH FURNITURE VENDOR AND SHALL 6 CONTRACTOR TO ENSURE LAMP LIGHT FIXTURES ARE PLUG-IN TYPE AND SHOULD HAVE INDIVIDUAL BUILT-IN SWITCHES. CONTRACTOR SHALL REFER POWER LAYOUT ON SHEET E-209 & E-210 FOR LAMP CONNECTION. 8 ICONTRACTOR SHALL PULL HARD -WIRED POWER CONNECTION FOR WALL RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� `�v G'lOnoklaAaL DATE: 07/22/19 +1G' c�TatRlr ��, I� i` III II III • , O I ,' a, C*I �,f l • -W 41 11 1 11 CUSTOM KING ONE BEDROOM GR LTG PLAN 1/4 if = 1 I-011 3 KING ONEBEDROOM GR LTG PLAN 1 /4 If= 1 1.011 s' �h Cb6l:Ywr� �III1■11 �� �� III I III I � m III I II CUSTOM KING STUDIO GR LTG PLAN 1/4 It = 1 I-011 n KING STUDIO GR LTG PLAN U 1/4 If = 1 I-011 ♦IB6 BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 6463 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF QP��'\si EHh� O' %p m N 1 12 o ATE �gB�ONAI E�` DATE: 2018D3.04 GARRY VERMMS. Phi PE Owner Iww' Nov THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 LO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY MSM CHECKED BY GWV PROJECT NO B4-134-1706 SHEET NAME TYPICAL UNIT LIGHTING PLAN-2 DRAWINGS NO. LT=209