HomeMy WebLinkAboutLT-211 - DIMMER RISER DIAGRAMRJ45 ETHERNET JACK (IF REQUIRED FOR FOR FIRST TIME PROGRAMMING) REMOTE PRESENT STATION REMOTE CONTROL STATION WITH RAISE AND LOWER CAPABILITIES PANELS TO BE SUPPLIED WITH LOCKING COVERS FACTORY ENGRAVED SCENES DESCRIPTIONS: #1:RAISE #2:LOWER DIMMER RISER DIAGRAM — 3/411 = 11.011 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� Avm iiUbw AaL x DATE: 07/22/19 MASTER CONTROL STATION SUPPLIED WITH BACK BOX. TBD CHANNEL DESCRIPTIONS TO BE FACTORY PROGRAMMED/ ENGRAVED. LOCATE NEXT TO DIMMER PANEL NOTE: E.C. TO CONFIRM CONTROL WIRE TYPES WITH MANUFACTURER REMOTE SCENE SELECT STATION (LOCATION T.B.D) REMOTE PRESENT SCENE SELECT STATIONS WITH 5- SCENE PRESET SELECT AND ON/OFF CLEAN- UP. PANELS TO BE SUPPLIED WITH LOCKING COVERS. FACTORY ENGRAVED SCENES DESCRIPTIONS: #1:SUNNY DAY #2:CLOUDY DAY #3:NIGHT #4:SPECIAL #5:CLEAN UP #6:ALL OFF CIRCUIT BREAKER PANEL MAIN FEEDS 1 PHASE, 2 WIRE, 120/240 VAC MAIN LUGS ONLY PROCESSOR RACK IF REQUIRED DIMMER PANEL#1 QUANTITY OF DIMMER PANELS TBD PER DIMMING MANUFACTURER, FEED SIZE T.B.D. BY ELECTRICAL ENGINEER V0 TB PROVIDE 31-0" CLEARANCE IN FRONT OF CABINET OR AS REQUIRED BY STATE CODE. MANUFACTURER TO CONFIRM SIZE AND MOUNTING LOCATIONS OF DIMMING PANELS PER SITE CONDITIONS. TO LOAD CIRCUITS ALL DIMMED LIGHTING CIRCUITS SHALL BE TWO WIRE. NO SHARED NEUTRALS. SERVICE: 1 PHASE,2 WIRE DIMMING PANEL-12" MAIN BUS:100A VOLTAGE: 120/240 VAC NEUTRALA00% MOUNTING:WALL MOUNTED MAINS:MLO TYPE:LOAD CENTRE AIC: 10,000 AMP AREA -ZONE DESCRIPTION CRT NO. TRIP POLE CONDUIT LOAD EM EMERGENCYWIRE CIRCUITS FIXTURETYPE REGISTRATION DESK LTG 1 15/1P 12 3/4" 140 N/A LED LOBBY AREA LTG 2 15/1P 12 3/4" 140 N/A LED LOBBY AREA LTG 3 15/1P 12 3/4" 200 N/A LED LOBBY AREA LTG 4 15/1P 12 3/4" 140 N/A LED BREAKFAST AREA LTG 5 15/1P 12 3/4" 300 N/A LED BREAKFAST AREA LTG 6 15/1P 12 3/4" 90 N/A LED SERVERY AREA LTG 7 15/1P 12 3/4" 70 N/A LED LOBBY AREA LTG 8 15/1P 12 3/4" 150 EM:45 LED BREAKFAST AREA LTG 9 15/1P 12 3/41, 180 EM:46 LED BREAKFAST AREA LTG 30 15/1P 12 3/4" 90 1 LED SERVERY AREA LTG 11 15/1P 12 3/41, 60 1 LED LOBBY AREA LTG 12 15/1P 12 3/41, 20 N/A LED 13 15/1P 12 3/41, LED 14 15/1P 12 3/4'. LED TOTALLOAD 1580 TOTAL LOAD IN AMPERE 13 Note: THIS DIM MER SCHEDULE AND RISER DAIGRAM IS FOR GENERAL REFERENCE. CONTRACTOR SHALL COORDINATEWITH DIMMERVENDOR FOR FINAL DIM MER SYSTEM DRAWING AND SPECIFICATION TAKING 10% SPARE CAPACITY IN AMP 14 TAKING NEC SPARE CAPACITY IN AMP 19 n DIMMER SCHEDULE 12" = 11_011 KEEP RIGHT SIDE OF DIMMER CABINET CLEAR FOR ACCESS TO MAIN FEED AND BRANCH CIRCUIT BREAKER BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF 4P �8'\ siEHh� e' %p m N 1 12 o AE ,y 90 . "'1:01I PNP:'2b �gBrONAL ��` DATE: 20180304 OARRY VERMAAS. PhD. PE Owner: A'Atom ��yr � THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 LO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY MSM CHECKED BY GWV PROJECT NO. B4-134-1705 SHEET NAME DIMMER RISER DIAGRAM DRAWINGS NO. LT-211