M-001 - GENERAL NOTES, LEGENDS _ ABBREVIATIONS
DESIGN DATA GENERAL NOTES LEGENDS ABBREVIATIONS DRAWING INDEX 28. PRODUCTS SYMBOL DESCRIPTION AABC ASSOCIATED AIR BALANCE COUNCIL MECHANICAL OUTDOOR DESIGN TEMPERATURES PRODUCTS: PROVIDE ALL EQUIPMENT AND MATERIALS NEW UNLESS NOTED OTHERWISE. ACCU A/C AIR COOLED CONDENSING UNIT AIR CONDITIONING CURRENT CATALOG SHEETS AND/OR SHOP DRAWINGS OF ALL MATERIAL AND EQUIPMENT FOR APPROVAL ADA AMERICAN DISABILITY ACT SHEET SHEETNAME REVISION CURRENT REVISION FROM ARCHITECTIENGINEER. ® ® SUPPLY DUCT (UP BDOWN) AFF ABOVE FINISHED FLOOR NUMBER DATE DESCRIPTION CITY, STATE: CARMEL, IN A.PIPING- PIPE FITTINGS SHALL BE COMPATIBLE WITH THE APPLICABLE PIPE MATERIALS. ® ® EXHAUST DUCT (UP B DOWN) AEG ABOVE FINISHED GRADE GENERAL NOTES, LEGENDS B 2019.03.04 ISSUED FOR PERMIT WINTER: 3.2° F PROVIDE DIELECTRIC UNIONS FOR CONNECTIONS BETWEEN DISSIMILAR MATERIAL PIPING. AHU AIR HANDLING UNIT M-001 ABBREVIATIONS B. VALVES -VALVES SHALL BE PROVIDED ON SUPPLIES TO EQUIPMENT AND COILS. VALVES OF RETURN AIR DUCT (UP & DOWN) ARCH ARCHITECT M-101 DETAILS-1 2019.03.04 ISSUED FOR PERMIT SUMMER DRY BULB: 90.9° F 2-112' AND SMALLER SHALL BE BRONZE WITH THREADED BODIES FOR PIPE AND SOLDER -TYPE ASTM AMERICAN SOCIETY FOR TESTING M-102 DETAILS-2 2019.03.04 ISSUED FOR PERMIT SUMMER WET BULB: 74.1°F CONNECTIONS FOR TUBING. VALVES OF T AND LARGER SHALL HAVE FLANGED IRON BODIES AND ® CEILING SUPPLY AIR DIFFUSER AV AND MATERIALS ATTIC VENT M-201 1 ST FLOOR MECHANICAL PLAN 2019.03.04 ISSUED FOR PERMIT BRONZE TRIM. LI-202 2ND FLOOR MECHANICAL PLAN 2019.03.04 ISSUED FOR PERMIT CEILING RETURN AIR DIFFUSER BDO BACK DRAFT DAMPER 3RO FLOOR MECHANICAL PLAN 2019.03.04 ISSUED FOR PERMIT I.DAMPERS - MUST COMPLY WITH UL555 AND SMOKE DAMPERS MUST COMPLY BE BOOSTER FAN PER THE IMCRS WITH ULSSSS PER THE IMC. � SIDE WALL REGISTER OR GRILLE BHP BRAKE HORSE POWER W203 M-204 4TH FLOOR MECHANICAL PLAN 2019.03.04 ISSUED FOR PERMIT INDOOR DESIGN TEMPERATURES D.DUCTWORK - FABRICATE DUCTWORK AS INDICATED AND IN ACCORDANCE WITH SMACNA. BLUG BTU BUILDING BETWE THERMAL UNIT W205 STH FLOOR MECHANICAL PLAN 2019.03.04 ISSUED FOR PERMIT CURVED ELBOWS SHALL HAVE A CENTERLINE RADIUS NOT LESS THAN I-1/2" TIMES DUCT SIZE, WxD NEW DUCT DEPTH BTWN BETWEEN ROOF MECHANICAL PLAN 2019.03.04 ISSUED FOR PERMIT WINTER 68-700F PROVIDE TURNING VANES WHERE NOT POSSIBLE. PROVIDE MANUAL VOLUM E DAM PERE ON ALL BAB BETWEEN JOISTS W301 M-301 SCHEDULES 2019.03.04 ISSUED FOR PERMIT SUMMER BRANCHES. INSULATE DUCT WITH MINIMUM OF I-ill"THICK FOIL SKIN INSULATION. �x�� EXISTING DUCT TO REMAIN B CABINET OA VENTILATION BALANCE 2019.03.04 ISSUED FOR PERMIT 750F E.EQUIPMENT - PROVIDE ALL EQUIPMENT WITH HIGH EFFICIENCY MOTORS. EQUIPMENT TO BE CB CATCH BASIN M401 SCHEDULE AS SPECIFIED ON DRAWINGS, INSTALLED WITH ENERGY ISOLATING VALVES OR DEVICES TO FLEXIBLE DUCTWORK CCU CONDENSER UNIT PREVENT ACCIDENTAL START-UP. INSTALL PER MANUFACTURER'S RECOMMENDATIONS CFM CUBIC FEET PER MINUTE 28.1 AIR DISTRIBUTION DEVICES: GRILLE REGISTERS AND DIFFUSERS SHALL BE BY ONE 0D SPIRAL DUCT CO CARBON MONOXIDE GENERAL NOTES MANUFACTURER WITH CONSTRUCTION MATERIAL, FINISH AND ACCESSORIES AS SCHEDULED CONC CONCRETE ON THE DRAWINGS. SOi PIPE RISE UP COND CONDENSATE 28.2 DUCTWORK PER HOTEL STANDARDS SHALL BE `GALVANIZED SHEET STEEL: COMPLY WITH ASTM CONT CONTINUATION 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE MOST RECENT EDITION OF A65L A r PIPE DOWN OR DROP CU CONDENSING UNIT THE FOLLOWING WHICH HAVE BEEN ACCEPTED THE AUTHORITY GALVANIZED 28.3. GALVANIZED COATING DESIGNATION: G (Z CUE CABINET UNIT HEATER L HAVING JURISDICTION:MECHANICAL CODE, BUILDING CODE, NATIONAL ELECTRIC CODE TION: MECHANICAL 28.4. FINISHES FOR SURFACE EXPOSED TO VIEW: MILL E MIL � DUCT TRANSITION -CONCENTRIC CW COLD WATER AND ALL LOCAL ORDINANCES. AND OUTSIDE A A. EXHAUST, DRYER VENTS, RANGE HOOD VENTS AND OUTSIDE AIR INTAKE DUCTS SHALL BE DOE DRY BULB TEMPERATURE 2. ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, ELECTRICAL, CONSTRUCTED OFDGALVANIZED SHEET METAL. METAL DUCTWORK SHALL �� DUCT TRANSITION -ECCENTRIC DBJ DUCT BETWEEN JOISTS PLUMBING AND FIRE PROTECTION DRAWINGS. GALVANIZED WITH ANON -HARDENING, NON -MIGRATING MASTIC SEALANT. PROVIDE HOT -DIPPED GALVANIZED STICSE LA CIADIN DIAMETER 3. REFER TO ARCHITECTURAL PLANS FOR EXACT CEILING GRID AND DIFFUSER STEEL FASTENERS, ANCHORS, RODS, STRAPS AND ANGLES FOR SUPPORT OF DUCTWORK � �'� DUCT TRANSITION-RECT TO RND D DOWN LOCATIONS. B. SUPPLYAND RETURNAIR DUCTWORK SHALL BE CONSTRUCTED WITH CLOSED -CELL REFRIGERANT LINE DP DEW POINT 4. ALL DUCT SIZES SHOWN IN THE PLANS ARE INSIDE CLEAR DIMENSIONS. ELASTOMERIC INSULATION AS PER IECC STANDARD. DR DRAIN 5. LOCATE ALL THERMOSTATS AT 60' ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. C. SUPPLYAND RETURN AIR DUCTWORK IN EXPOSED CEILING AREAS SHALL BE CONSTRUCTED CONDENSATE WATER DWG DRAWING EXACT LOCATION OF ALL THERMOSTATS SHALL BE APPROVED BV THE ARCHITECT, OF SPIRAL METAL AND COMPLY WITH SMACNA. DS DUCTLESS SPLIT INTERIOR AND LS O. MATERIALS ATERTO COMPLY WITH HVA CONSTRUCTION rB MANUAL VOLUME DAMPER EAT ENTERING AIR TEMPERATURE NTRACTDESIGNER, 6. CONTRACTOR SHALL CLEAN ALL COILS AND REPLACE FILTERS AT SUBSTANTIAL LL CLEAENGINEER.ALL STANDARDS - ME FL TALE MA STANDARDS - METAL AND FLEXIBLE" FOR ACCEPTABLE MATERIALS, MATERIAL THICKNESS, AND MATERIALS, MA ® SMOKE/CO SENSOR EC ELECTRICAL CONTRACTOR COMPLETION. OTHERWISE INDICATED. DUCT CONSTRUCTION MEG, EDH ELECTRIC DUCT HEATER 7. AIR CONDITIONING EQUIPMENT SHALL BE A SPECIFIED. ARCHITECT AND ENGINEER KS, S DI COLORAL IONS, AND SHALL BE FREE OF PITTING, SEAM MARKS, ROLLER MARKS, STAINS, DISCOLORATIONS, AND SEAM ARKS T O THERMOSTATISENSOR EER ENERGY EFFICIENCY RATIO I WILL REVIEW SUBSTITUTIONS FOR COMPATIBILITY. OTHER IMPERFECTIONS. ® EXHAUST B VENT EF EXHAUST FAN S. SLEEVE AND SEALALL PIPING PASSING THROUGH WALLS, FLOORS AND ROOF UNLESS 28.5 PIPING: REFRIGERANT LINES SHALL BE TYPE ASTM B 208, TYPE ACR WITH ASME B16.50 WROUGHT EL ELEVATION NOTED OTHERWISE. COPPER FITTINGS. CONDENSATE PIPE AND FITTING SHALL BE PVC SCHEDULE 40 WITH SOLVENT ELEC ELECTRICAL WELDS. GRAVITY LOUVER ENT ENTERING 9. ALL CUTTING, PATCHING AND REPAIR WORK SHALL BE THE RESPONSIBILITY OF THE ER EXHAUST REGISTER TRADE INVOLVED. P9 EXECUTION: Fta} FIRE SMOKE DAMPER ESP EXTERNAL STATIC PRESSURE 10. THE MAXIMUM ALLOWABLE LEAKAGE FOR THE DUCTWORK IS 2%. 29.1 THE MECHANICAL CONTRACTOR SHALL PROVIDE WIRING DIAGRAMS AND BE RESPONSIBLE EXIST EXISTING 11. AIR HANDLER UNIT FILTER RACKS SHALL BE READILY ACCESSIBLE FOR MAINTENANCE. FOR THE PROPER OPERATION OF THE MECHANICAL SYSTEMS. THE MECHANICAL CONTRACTOR 0 FIRE DAMPER F FAHRENHEIT 12. CONTRACTOR SHALL INSTALL HVAC SYSTEMS AS REQUIRED BY THE MANUFACTURER SHALL FURNISH THE WIRING DIAGRAMS TO THE ELECTRICAL CONTRACTOR FOR COORDINATION FCU FAN COIL UNIT TO ENSURE QUIET OPERATION. CONTRACTOR SHALL RESPONSIBLE FOR THE PRIOR TO THE ELECTRICAL CONTRACTOR COMMENCING WORK. CEILING MOUNTED EXHAUST FAN FD FIRE DAMPER ELIMINATION OF ANY UNDUE VIBRATION OR SOUND. VIBRATION RATION OR SOUND SHALL NOT TEST THE DESIGNATED TEST AND BALANCE COMPANY SHALL TEST, BALANCE AND FLA FULL LOAD AMPERE BETALLSYMBOL,NOTEMITTED TO DING STRUCTURE ANODIC SPIED AREAS RE DATA RECORD DATA FOR THE PERFORMANCE OF THE AIR CONDITIONING SYSTEM, INCLUDING SUPPLY, � BDD BACK DRAFT DAMPER FLEX FLEXIBLE RETURN AND MAKEUP AIRFLOW. THE TEST AND BALANCE WORK SHALL BE PERFORMED IN FLR FLOOR 13. NOT ALL SYMBOLS, NOTES AND DETAILS MENTIONED HERE ARE USED IN THIS PROJECT. ACCORDANCE WITH AABC OR NEBB STANDARDS. UPON COMPLETION OF TEST AND BALANCE WORK m FSD FIRE SMOKE DAMPER 14. CONDENSATE DRAIN PIPING TO BE AS SPECIFIED PER PLUMBING PLANS. IF NOT AND PRIOR TO REQUESTING FINAL INSPECTION AND ACCEPTANCE OF PROJECT SUBMIT Q W SD DUCT SMOKE DETECTOR GA GAUGE SPECIFIED THEN USE TYPE'L' COPPER OR PVC WHERE ALLOWED BV CODE WITH 1/2' (3)COMPLETE ES F THE R TOT NCEGUARANTEE, GAL GALLON ARMA FLEX INSULATION. PROVIDE APPROVED WATER LEVEL DETECTOR OR FLOAT 3GUARANTEE: 2R GUARANTEE: THE CONTRACTOR SHALL GUARANTEE, THAT ALL WORK INSTALLED WILL BE FREE THE CONTRACT R SHALL NTEE, ALL WORK INSTALLED � CEILING -MOUNTED SUPPLY DIFFUSER GC GENERAL CONTRACTOR SWITCH TO AUTOMATICALLY SHUT DOWN THE AIR-CONDITIONING. UNIT, AS A FROM DEFECTS IN WORKMANSHIP AND MATERIALS. IFO DURING THE PERIOD OF ONE YEAR, OR DAMPER GPM GALLONS PER MINUTE SECOCODE. DARY INSYSTEM COMPLY WITH LOCAL MECHANICAL CERTIFICATION OF F OTHERWISE AND ACCEPTANCE OF GRH GRAVITY RELIEF HOOD SUPPLYC DENSATTO OSED BY FIELD CODE. SUPPLY CONDENSATE PUMP WHERE NECESSARY AS IMPOSED BY FIELD FECTSPECIFIED, INFROM PERFORMANCE WORK, IF ANY DEFECTS IN WORKMANSHIP, MATERIALS OR PERFORMANCE APPEAR, THE S WORKMANSHIP, x SUPPLY DIFFUSER FACE SIZE HC HOLLOW CORE CONDITIONS. 16, PROVIDE ALL CONTROL WIRING AND CONDUIT IN COMPLIANCE WITH NEC. CONTRACTOR SHALL, WITHOUT COST TO THE OWNER, REMEDY SUCH DEFECTS WITHIN A 1 500 R F AME I EUI"L1 E TE HE HORSEPOWER 16. PROVIDE MATERIALS WHICH HAVE FLAME SPREAD RATING OF 250R LESS AND REASONABLE TIME. 2g4 PROPERTY DAMAGE: PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR THE PROPER I' SIDEWALL-MOUNTED SQUARE SUPPLY DIFFUSER ER HVAC HOUR HEATING, VENTILATING, A/C SMOKE DEVELOP RATING OF 50 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM INSTALLATION OF MATERIALS AND EQUIPMENT SPECIFIED IN THIS SECTION. DO NOT CUT OR DRILL 7� DAMPER HZ FREQUENCY E84. . 17 INSULATE SUPPLY AND RETURN DUCTS TOA MINIMUM R-VALUE OF UNLESS STRUCTURAL MEMBERS WITHOUT THE CONSENT OF THE ARCHITECT/ENG INFER. CONTRACTOR IAQ INDOORAIRQUALITY INSTALLED IN A MECHANICALLY COOLED SPACE OR IN A CAVITY WHOSE SE EXTERIOR SHALL BE HELD LIABLE FOR ANY DAMAGE CAUSED HIS WORK UNDER THIS CONTRACT. ®x SUPPLY DIFFUSER FACE SIZE IBC INDIANA BUILDING CODE WALLS ARE INSULATED, IN WHICH CASE THE R-VALUE MAY BE 4.2. ALL INSULATION 29.5 COMPLIANCE: ALL WORK AND MATERIAL SHALLL BE SUBJECT TO INSPECTION AT ANY AND ALL 1 500 IECC INDIANA ENERGY CONSERVATION SHALL BE CLOSED CELL ELASTOMERIC. TIMES BY REPRESENTATIVES OF THE ARCHITECT/ENGINEER. IF ARCHITECT OR ENGINEER OR SIDEWALL MOUNTED SUPPLY GRILLE CODE 18. IN HANDICAPPED ACCESSIBLE AREAS, MOUNT TOP OF THERMOSTAT AT 48"ABOVE OWNER'S INSPECTOR FINDS THAT ANY MATERIAL DOES NOT CONFORM WITH THESE DRAWINGS, THIS IFGC INDIANA FINISHED FLOOR. CONTRACTOR SHALL, WITHIN THREE WORKING DAYS AFTER BEING NOTIFIED BY THE IMC INDIANA MECHANICAL CODE MECFUEL HANICAL CODE 19, PROVIDE FILTERS IN AHU'S DURING CONSTRUCTION. REPLACE WITH PLEATED MEDIA ARCHITECT/ENGINEER, REMOVE THE MATERIAL. IF THE MATERIAL HAS BEEN INSTALLED, THE ENTIRE 24x SUPPLY GRILLE FACE SIZE IN INCH FILTERS AT SUBSTANTIAL COMPLETION. EXPENSE OF REMOVAL AND REPLACEMENT INCLUDING CUTTING AND PATCHING THAT MAY BE NUMBEROF THESAMESIZEGRILLEAIRFLOWRATE JTS JOISTS 20. LOCATE WALL AND ROOF TERMINATIONS AT THE SAME RELATIVE ELEVATION AND NECESSARY, SHALL BE BORNE BY THIS CONTRACTOR. WORK SHALL NOT BE CLOSED IN OR (I� CEILING -MOUNTED SUPPLYAIR SLOT DIFFUSER KW KILOWATT HORIZONTAL POSITION TO MAINTAIN AN UNIFORM APPEARANCE. WHEN IN DOUBT, COVERED BEFORE INSPECTION AND APPROVAL BY THE ARCHITECT/ENGINEER OR REPRESENTATIVE. DAMPER EAT LEAVING AIR TEMPERATURE COORDINATE PLACEMENT WITH ARCHITECT. PRIME COATAND PAINT EXTERIOR COST OF UNCOVERING AND MAKING REPAIRS WHERE UNINSPECTED WORK HAS BEEN CLOSED IN MAU MAKE-UP AIR UNIT TERMINATIONS TO MATCH BUILDING COLOR. SHALL BE BORNE BY THIS CONTRACTOR. M 48x6 SUPPLY AIR SLOT DIFFUSER 1 FACE SIZE MAX MAXIMUM 29.6 CLEAN-UP: AT COMPLETION OF WORK, THIS CONTRACTOR SHALL CLEAN UP AND REMOVE ALL 1 500 IN UMBEROF SAME SIZE D IF USER I AIR FLOW RATE MC MECHANICAL CONTRACTOR 21. SLEEVE AND FIRE STOP PENETRATIONS THROUGH FIRE RATED SYSTEMS TO MAINTAIN DEBRIS AND MATERIALS NOT INSTALLED IN WORK, LEAVING PREMISESCLEAN. MCA MINIMUM CIRCUIT AMPS RATING OF SYSTEM. USE MINIMUM GALVANIZED STEEL GAUGE DUCT AS REQUIRED TO 171 CEILING -MOUNTED RETURN AIR DIFFUSER MECH MECHANICAL MAINTAIN OF SYSTEM. 30. MINIMUM MATERIALS SPECIFICATIONS MED MEDIUM 22. PROVIDE MINIMUM 28 GAUGE GALVANIZED STEEL ROUND DUCT FOR DRYER AND BATH JE x RETURN AIR DIFFUSER FACE SIZE GR EXHAUST. ALUMINUM IS ALLOWED IF 26 GAUGE PER STATE MECHANICAL CODE AND THE FOLLOWING ARE MINIMUM MATERIALS SPECIFICATIONS RECOMMENDED TO ACHIEVE A 1 500 NUMBEROFSAMESIZEDIFFUSER AIRFLOWRATE ME MANUFACTURER ONLY IF 5 FT AWAY FROM FIRE RATED PENETRATIONS. SUBSTANTIALLY TIGHT INSTALLATION THAT WILL LAST: MIN MINIMUM 23. ASSEMBLE DRYER DUCTS WITHOUT SHEET METAL SCREWS OR OTHER FASTENERS 30.1 ALL MATERIALS © CEILING MOUNTED RETURN AIR SLOT DIFFUSER MOCP MAXIMUM OVERCURRENT EXTENDING INTO AIR STREAM. RUN EACH JOINT IN THE DIRECTION OF AIRFLOW TO A. SHALL HAVE A MINIMUM PERFORMANCE TEMPERATURE RATINGS PER UL 181 (DUCTS), MOD PROTECTION MOTORIZED DAMPER AVOID CATCHING LINT. SEALJOINTSWITH NON-COMBUSTIBLE MATERIAL. UL181A(CLOSURE SYSTEMS FOR RIGID DUCTS), UL181B (CLOSURE SYSTEMS FOR FLEXIBLE DUCTS) x RETURN AIRSLOT DIFFUSER FACE SIZE 600 NUMBEROF SAME SIZE DIFFUSER AIR FLOW RATE NA NOTAPPLICABLE 24. COORDINATE ALL HVAC SYSTEM DRAWINGS WITH TRUSS MANUFACTURER DURING AND/OR UL 181BM(MASTIC). NEBB NATIONAL ENVIRONMENTAL SHOP DRAWING REVIEW TO AVOID INTERFERENCES BETWEEN MECHANICAL SYSTEMS SIDEWALL MOUNTED RETURN GRILLE BALANCING BUREAU AND ROOF STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS B. SHALL HAVE A FLAME SPREAD RATING OF NO MORE THAN 25 AND A MAXIMUM SMOKE } NTS NOT TO SCALE NOT TOIDE ASSOCIATED WITH TRUSS INTERFERENCES THAT OCCUR IN THE FIELD DURING DEVELOPED RATING OF 50 (ASTM E84 ). � CIA CONSTRUCTION.000RDINATE IN ADVANCE. 30.2 FACTORY -FABRICATED DUCT SYSTEMS 24x RETURN GRILLE FACE SIZE OPNG OPENING 25. PROVIDE ENGRAVED TAGS FOR ALL CU'S. MOUNT TAGS PERM ANE NTLV ON CU'S AND A. SHALL HAVE A MINIMUM PERFORMANCE TEMPERATURE RATINGS PER ALi 81(D UCTS), } NUMBER OF THE SAME SIZE GRILLE AIR FLOW RATE PC PRESSURE DROP DISCONNECTS. UL181A(CLOSURE SYSTEMS FOR RIGID DUCTS), UL181B (CLOSURE SYSTEMS FOR FLEXIBLE DUCTS) SIDEWALL-MOUNTED TRANSFER GRILLE PH PHASE 26. PROVIDE AN AIR BALANCE REPORT FOR THE SUPPLYAIR SYSTEM OF EACH AHU ON AND/OR UL 181BM(MASTIC). } PLBG PLUMBING THE SCHEDULE. MEASURE THE AIRFLOW OUT OF EACH SUPPLY REGISTER AND 30.3 FIELD -FABRICATED DUCT SYSTEMS T 12x6 TRANSFER GRILLE FACE SIZE PTAC PACKAGED TERMINAL AIR ATTEMPT TO BALANCE THE SYSTEM TO THE AIRFLOW LISTED ON THE HVAC PLANS. NUMBER OF THE SAME SIZE GRILLE R W RATE CONDITIONER LIST ANY DIFFICULTIES AND OBSERVATIONS. PERFORM THIS TEST AND BALANCE A. DUCTS :FIELD -FABRICATED DUCT SYSTEMS SHALL BE UL 181. BEFORE ANY DUCTS ARE CLOSED IN WITH DRYWALL. HAVE THE AIR REGISTERS IN B. MASTIC SEALANTS AND MESH: CEILING -MOUNTED EXHAUST AIR GRILLE PWH POOL WATER HEATER PLACE. PROVIDE TEMPORARY POWER AS REQUIRED. SUBMIT THIS REPORT TO THE 1. SEALANTS SHALL BE UL 1818M, NON -TOXIC, AND WATER RESISTANT; EXHAUST AIR GRILLE FACE SIZE QTY RD QAUNTITY ROOF DRAIN ARCHITECT ON CONTRACTOR LETTERHEAD. THE PURPOSE OF THIS PROCEDURE IS TO ® NUMBER OF SAME SIZE GRILLE AIR FLOW RATE REF REFERENCE DETECTAND SOLVE ANY AIRFLOW PROBLEMS WHILE OPTIMIZING THE SYSTEM.TEST 2. SEALANTS FOR INTERIOR APPLICATIONS SHALL PASS ASTM C731(EXTRUDABILITY AFTER AND BALANCE SHALL BE CONDUCTED BY A SEPARATE CONTRACTOR(OTHER THAN AGING)AND ASTM 2202(SLUMP TEST ON VERTICAL SURFACES). CEILING -MOUNTED EXHAUST AIR GRILLE RH RECIRCULATING HOOD PROJECT HVAC CONTRACTOR) CERTIFIED PER AABC OR NEBB. 3. SEALANTS AND MESHES SHALL BE RATED FOR EXTERIOR USE. RTU ROOFTOP UNIT x EXHAUST AIR GRILLE FACE SIZE ED SMOKE DETECTOR 27. GENERAL 4. SEALANTS FOR EXTERIOR APPLICATIONS SHALL PASS ASTM C731,C732 (ARTIFICIAL ® NUMBER OF SAME SIZE GRILLE AIR FLOW RATE SEER SEASONAL ENERGY EFFICIENCY WEATHERING TEST), AND D2202. RATIO 27.1 PROVIDE LABOR,MATERIALS, AND EQUIPMENT REQUIRED FOR A COMPLETE C. PRESSURE -SENSITIVE TAPES; SIDEWALL-MOUNTED CA SUPPLY GRILLE SF SUPPLY FAN SYSTEM AS OUTLINED IN THESE SPECIFICATIONS AND AS SHOWN ON DRAWINGS. SET SHEET 1.PRESSURE SENSITIVE TAPE SHALL MEET THE REQUIREMENTS OF THE FLEX DUCT 27.2 VERIFY ALL EQUIPMENT VOLTAGE CHARACTERISTICS WITH AVAILABLE VOLTAGE MANUFACTURER. 0 Bx6 OA GRILLE FACE SIZE SP STATIC PRESSURE USED AT THE SITE PRIOR TO PURCHASING EQUIPMENT. 1 35 INUMbtK OF SAME SIZE GRILLE I AIR FLOW RATE STU STANDARD TEMP TEMPERATURE TEA TREATED FRESH AIR ® CEILING -MOUNTED EXHAUST AIR SLOT DIFFUSER TFGT TOP OF FOOTING E224x8 EXHAUST AIR GRILLE FACE SIZE TG TONS 1 OLD NUMBER OF SAME SIZE GRILLE AIR FLOW RATE TR OF TONS OF REFRIGERATION TTJ TIGHT TO JOISTS TWJ THRU WEB OF JOISTS SPOT ELEVATION If BOTTOM OF DUCT UC UNDERCUT UH UNIT HEATER VD VOLUME DAMPER VEH VEHICLE VEST VESTIBLE VRV VARIABLE REFRIGERANT VOLUME WB WET BULB TEMPERATURE W/ WITH RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ((�� `�vmlUtlenrJnwJ�L x DATE: 07/22/19 BAS E'' BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base4.com RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QP�.'\si EHh 1 12 i 9'. 2 AE W y W O'' OF '0 ':YO I PNP 2 �gBrONAL �Os DATE: 2D1e.Ds.D4 GARRY VERMI Phi HE Owner: e e THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 SUITES BY HILTOH HOMEN, CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 MO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY DIRT CHECKED BY GWV PROJECT NO, 134-134-1705 SHEET NAME GENERAL NOTES, LEGENDS & ABBREVIATIONS DRAWINGS NO. M=001