Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M-101 - DETAILS-1
' PROVIDE FLOAT SWITCH CONFORMING TO STEEL RODS W/THREAD ED UL508, THAT WILL SHUT OFF THE COMPRESSOR ENDS(TYP. 4 PLACES) IN THE EVENT THAT THE PRIMARY DRAIN IS SUPPORT FROM BLOCKED. STRUCTURE ABOVE AS PAP REQUIRED �JF<�.. -1 EXTENDED OPERATOR ON BALANCE THREADED CAP. THREADED CAP. DAMPER HAND WITH 1/4" D HOLE UNION TIGHTENED( COOLING COIL DRILLED IN TOP, CVO � SPIN -IN FITTING WNOLUME CONTROL DAMPER HAND TIGHTENED. �P (INSUL. PER SPEC.) DRAW BAND VIB. ISOLATOR PLENUM FLEX. CONN. / FLEXIBLE DUCT MAX. B'-0" IN LENGTH FULLY DRAIN PAN EXTENDED m FAN COIL UNIT MANUAL VOLUME CASING SLEEVE A DAMPERAND MOTORIZED MOTORIDAMPER O RELEASE ABOVE GRADE FLEX. CONN. BLANK -OFF PLATES WHERE REQUIRED DRAW BAND CONDENSATE DRAIN PIPING DIMENSIONS: DIFFUSER NECK (INSUL. PER SPEC.) A= FULL SIZE OF UNIT DRAIN CONNECTION OUTSIDE AIR B = 1 1/2 TIMES FAN SUCTION STATIC PRESSURE REFRIGERANT LINES - RUN CEILING TEE DIFFUSER CONE (INSUL. PER SPEC.) C = FAN DISCHARGE STATIC PRESSURE PLUS 12 INCH TO CONDENSING UNIT LIGHT ^ COORDINATE MOUNTING/CURB HEIGHT AS REQUIRED TO PROVIDE PROPER PRIMARY DRAIN (CONDENSATE PUMP). L� CONDENSATE DRAINAGE. FLOAT SWITCH SUPPLYAIR SUPPLYAIR DUCT COND DRAIN PAN DIFFUSER MOUNTING AHU CONDENSATE DETAIL HORIZONTAL FAN COIL UNIT DETAIL 1 3 L NOT TO SCALE NOT TO SCALE NOT TO SCALE F MOUNTED HVAC UNIT ATTACHED TO R (INSIDE CURB) WITH # @OL Q2 Q WATERPROOF ON N HE ROOF MOUNTEDO REQUIRED BY PRE -PUNCHED HOLES EXTERIOR WALL ONLY HVAC EQUIPMENTOF MOUNTED UNIT. OR ROOF NTED HVAC UNIT ATTACHED TO CURB WATERPROOF CLAMPING 1/4" NEOPRENE RUBBER 24" LONG, 16 GA, G90 GALV. STEEL ON EXTERIORWALL ONLY GASKET CONTINUOUS -PS@24" O.C. AND SCREWED WITH (4) 6 TO NAILER INSIDE THE CURB. C SEALANT 8 BACK UP m AROUND PERIMETERMS WALL MATERIAL REQUIRED ON 2X12 NAILER STRIP TO. G90 GALV. EXTERIOR WALL ONLY BE SECURED TO CURB RB STRAP@2'-0"O.C. PIPE WITH (2) ROWS OF #12 INSULATION & TEK SCREWS @6" O.C. KET BY GC. _ ---- FASTNERS. 16" O.C. MIN. 16 GAGE CURB O SHIM AS REQUIRED TO LEVEL UNIT SECURE TO PLANK OO INSULATION ESCUTCHEON L W/ 0.145 P.A.F. W/ 13/4" NOTE: WALL PLATE WHERE EMBED @ 12" O.C. EXPOSED 1. MOTOR( INTERNAL OR EXTERNAL) 2. RETAINING ANGLES -7 3. DAMPER UNIT PIPE THRU NON -RATED WALL NOTE: PRE-ENG INEERED WOOD 1. EQUIPMENT SHALL BE ANCHORED TO 4O 4. WALUFLOOR OPENING FLOOR TRUSSES. 5. DUCT/SLEEVE BREAK -AWAY WITHSTAND TOTAL WIND LOAD AT 115 MPH. REFER TO STRUCTURAL 6. SLEEVE 2. MINIMUM CURB HEIGHT SHALL BE 8". DRAWINGS TYPICAL PIPE SLEEVE DETAIL EQUIPMENT/ CURB ANCHORING FIRE SMOKE DAMPER DETAIL 4 C 5 G V NOT TO SCALE NOT TO SCALE NOT TO SCALE EXHAUST DUCT TO ERV UNIT EXHAUST AIR ROOF ThE 4" ROUND EXHAUST GRILLE OA SUPPLY DUCT } AMERICAN ALDES CERB-CS-II CONNECT TO OA GRILLE STRUCTURE 4 CEILING WITH BACK DRAFT DAMPER / 06" PIPE 1 06"PIPE 06"PIPE SHEET METAL DUCT i PROVIDE ILL APPROVED FIRE OUTSIDE AIR SEAL AT DUCT PENETRATION DES OF RATED ASSEMBLY CSRB-W B-II INTEGRATED OASUPPLYDUCT �� WITH CAR -II. 2 HOUR FIRE RATED FROM ROOF TOP UNIT- FLOW DUCT SHAFT RATED FLOOR "ROUND CEILING IN EXHAUST GRILLE CORRIDOR WALL DROPPED CEILING AT ENTRY AMERICAN ALDES CERB-CS-II FOYER OF GUEST ROOM. CEILING WITH BACK DRAFT DAMPER M GWH GWH GWH TYPICAL OA GRILLE DETAIL MOUNTED IN SOFFIT SHEET METAL DUCT RATED FLOOR GAS WATER HEATER TYP. EXHAUST SHAFT DETAIL NOTE: PIPE 3(1 DRAIN PAN 1. LOW -PROFILE SUB -DUCT RISER (LSR04) TO BE USED FOR 22" SUB DUCT. DRAIN PAN DRAIN TO SPILL INTO FD 2. CONTRACTOR HAS OPTION TO USE 2HR RATED SHAFT WALLS INSTEAD OF SHEET METAL DUCT WITH DUCT WRAP. OILET ROOF EXHAUST DETAIL GNOT DETAIL TYPTO E DETAIL 7 TO SCALE V T SOLAEGRLLE OTRHR S RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel ` ((�� Uv G'lenrJnwJ�L x DATE: 07/22/19 BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.cc m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VS' EHh� e' %p m N 1 12 o ATE OF �gBrONAL ��` DATE :2019.03.04 GARRY VERMAAS. Phi PE F"NKI IN IN MJ Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 MO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY DIRT CHECKED BY GWV PROJECT NO. B4-134-1705 SHEET NAME DETAILS-1 DRAWINGS NO. M-101