HomeMy WebLinkAboutM-102 - DETAILS-2STIFFFN RI APE AR 10 1/2" jl5mmj ROUND ROD PIN INSULATION Ducr INSULATION STAND-OFF DAMPER BLADE VDLE WITH LOCKING QUADRANT INSIDE END BEARING - OUTSIDE END BEARING 1/8" 161Pm1 CLEARANCE All / AROUND SECTION NOTE: 1. DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR MULTI -BLADE DAMPERS & ROUND DAMPERS. STANDARD RADIUS ELBOW NOTE: I. THE INTERIOR SURFACE OF ALL ELBOWS SHALL BE MADE SQUARE. 2. ALL SQUARE ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA. R SHALL EQUAL 3R BE GREATER THAN 1/3W. 2 SHALL EQUAL OR 3E GREATER THAN 1/6W. NOTE: 1. THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND. 2. ALL STANDARD RADIUS ELBOWS SHOWN ON FLOOR PLANS MAY BE MADE SHORT RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED SHORT RADIUS ELBOW WITH TWO VANES AND FASTENED AS RECOMMENDED BY SMACNA. DUCTWORK SQUARE & RADIUS ELBOWS I V .. .LUG. ...... - 2X2X1/8" GALVANIZED 0'-0" ANGLE H. D. �� V. (TYP.) (2)EA#14X1-i14 - THREADED CAP. T-5 METAL SCREWS W/CAULK SILICONE. O/A DUCT O.D. T(TYP,)(2)EA# METALSCREWS WICAULK CONE 1-1/2"e GALVANIZED SCHEDULE40 PIPE.- @ 2X2X1/8"GALVANIZED 0 ANGLE H.D. PLYWOOD SILICONE P SHEATHING (BY OTHERS) NAILED SS PIPE CLAMP ROOF FLASHING (BY OTHERS TYP. (BV OTHER)Zy 6X6x3/8"BASE 11/2" 3" 1 / 3 1 PLATE FIX TO PLANK W/ (4) 0.145 P.A.F. WI 1 3A" EMBED PRE-ENGINEERED WOOD L FLOOR NOTE: FLOOR TRUSSES ' ALL DUCT JOINTS TO BE SEALED WITH SILICON CAULK ON ROOF. ' TOP OF DUCT TO BE PITCHED TO SHED WATER. ' DUCT SHALL BE SUPPORTED WITH APPROVED HANGERS AT INTERVALS NOT EXCEEDING 10 FEET (3048 MM) IN ACCORDANCE WITH THE REQUIREMENTS OF IMC SECTIONS 61 BYOTHER APPROVED DUCT SUPPORT SYSTEMS DESIGNED IN ACCORDANCE WITH THE IMC. NOTE: ' DUCT SHALL BE ANCHORED TO WITHSTAND TOTAL WIND SPEED OF 115 MPH `PRESSURE TREATED 4X4 BLOCKING UNDER DUCTS, LAID ON ROOF, WITH GALVANIZED METAL STRAPS OVER DUCTS IS AN ACCEPTABLE ALTERNATE DUCT ROOF SUPPORT DETAIL I, RGLLRJGY FYR 4YI1 J I RUL, I W 11 Subject to compliance with all regulations of State and Local Codes City of Camel ((�� `�vmlUllDnrJnDIJ�L DATE: 07/22/19 SECURE SIDE GRILLE TO DUCT COLLAR AT AS PER MANUFACTURER RECOMMENDATIONS - SUPPLY SIDE GRILLE -� 11 iC! SUPPLY DUCT CEILING DRYER ENCLOSURE (SEE ARCHITECTURE AND MECHANICAL OPL-300 LINT COLLECTOR PLAN) DUCT EACH DRYER WALL CAP WITH NO COLLAR BIRDSCREEN SEPARATELY TO AVOID A FIRE 1 HAZARD DUE TO LINT 5 COLLECTING IN THE MANIFOLD _N ARCHITECTURAL LOUVER PROVIDE MOD INTERLOCKED DRYER WITH DRYER OPERATION FINISHED FLOOR VENT ING DETAIL MVD PAINTED TO \DJACENT WALL FLEXIBLE DUCT MAIN EXHAUST OR RETURN AIR FLOW 1/4W OR 4" 1102mm1 MIN. BRANCH DUCT yl=L PROVIDE VOLUME DAMPER PLAN VIEW EXHAUST OR RETURN BRANCH DUCTW 12 NOTESEVERAL DRYERS D UCT ED SEPARATE LV TO ONE LINT FILT ER 1. REFER TO MANUFACTURER'S RECOMMENDATION & INDIANA FUEL GAS CODE SECTION 304.6.2 FOR COMBUSTION AIR OPENING SIZES. 2. WHERE THE SOURCE OF CONTAMINANT IS LOCATED WITHIN 10' HORIZONTALLY OF COMBUSTION INTAKE OPENING, SUCH OPENING SHALL BE LOCATED A MINIMUM OF T BELOW THE CONTAMINANT SOURCE AS PER IMC 401.4.1. 3. THE INSTALLATION OF DRYER EXHAUST DUCTS SHALL COMPLY W ITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IMC 504.7. 4. GC SHALL INSTALL DRYER INA SEPARATE ENCLOSURE. GC SHALL COORDINATE WITH MANUFACTURER FOR ENCLOSURE AND CLEARANCE REQUIREMENT FOR DRYER. APPLY DUCT MASTIC, 3M 900, OR EQUAL TO JOINTS, ALL AROUND, BOTH SIDES. - VERTICAL GUILLOTINE DAMPER W/U.L. RATING 18 GA. STEEL SLEEVE t FASTEN TO F.D. FRAME W/l/2"WELDS6"O.C. DUCTWORK SEE FOR SIZES PLANS ACCESS PANEL SCHEDULE DUCT WIDTH PANEL SIZE UPTO 12" 6"x12" 13"TO 24" 12"x12' 25"80VER 1B'X18" ELEVATION \ HORIZONTAL FIRE DAMPER AT WALL INSTALL FIRE DAMPER IN ACCORDANCE WITH N.F.P.A. PAMPHLET NO. 90 A. 15 rlrcLJMIVI NOT TO SCALE SYSTEM NUMBER-W-L-7161 FEBRUARY 07, 2007 F RATING -1 AND 2 HE T RATING -0 HR "A" FRAME FIRE DAMPER RATED FOR 1-112 HRS. UNLESS NOTED OTHERWISE. FIRE DAMPER ACCESS DOOR. LABEL "FIRE DAMPER ACCESS". SEE SCHEDULE FOR SIZE. PACK 112" TO III W/FIBROUS MATERIAL AND SEAL W/NON HARDENING SEALER. RETAINING ANGLES TO BE 2" X 2" X 1/8". SECURE TO 18 GA. SLEEVE ini WELDS AT 6" O.C. DO NOT SECURE ANGLES TO WALL. PROVIDE ANGLES ON ALL FOUR SIDES OF SLEEVE, AT BOTH SIDES OF WALL. FIRE RATED WALL Bill SECTION A -A 1. WALL ASSEMBLY - THE 1 OR 2 HR FIRE -RATED GYPSUM BOARD/STUD SHAFT WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U400 OR V400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORYAND SHALL INCORPORATE THE FOLLOWING CONSTRUCTION FEATURES: A. STEEL STUDS -"C-H"OR "C-T" SHAPED STUDS, MIN 2-1/2 IN. (64 MM) WIDE BY 1-1/2 IN. (38 MM) DEEP, FABRICATED FROM MIN NO. 25 GAUGE (0.6 MM THICK) GALV STEEL, SPACED MAX 241N. IS 10 MM) OC. B. GYPSUM BOARD' -1 IN. (25 MM) THICK, 24 IN. (610 MM) WIDE GYPSUM LINER PANELS INSTALLED VERTICALLY. MAX DIAM OF CIRCULAR CUTOUT IN GYPSUM LINER PANEL IS 6IN. (152 MM). C. GYPSUM BOARD' -1/2IN. OR 518 IN. (13 OR 16 MM) THICK, 48 IN. (1.2 M) WIDE GYPSUM BOARDS. THE GYPSUM BOARD TYPE, THICKNESS,NUMBER OF LAVERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF CIRCULAR CUTOUT IN GYPSUM BOARD IS 6 IN. (152 MM). THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. 2. STEEL DUCT- NOM 5 IN. (127 MM) DIAM (OR SMALLER) NO. 30 GAUGE (OR HEAVIER) GALV STEEL DUCT INSTALLED CONCENTRICALLY OR ECCENTRICALLY WITHIN OPENING. ANNULAR SPACE BETWEEN DUCT AND PERIPHERY OF OPENING TO BE MIN 0 IN. (0 MM, POINT CONTACT) TO MAX 1 IN. (25 MM). DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 3. FILL, VOID OR CAVITY MATERIALS' -CAULK OR SEALANT- MIN 1 IN. (25 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE GYPSUM BOARD LINER PANEL FLUSH WITH THE FACES OF THE LINER PANEL. MIN 581N. (16 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE GYPSUM BOARD ANNULUS, FLUSH WITH THE FINISHED SIDE OF THE WALL. MIN 112 IN. (13 MM) DIAM BEAD OF CAULKAPPLIED TO THE PENETRANT/GYPSUM BOARD INTERFACE AT THE POINT CONTACT LOCATION ON THE FINISHED SIDE OF THE WALL. 3M COMPANY - CP25WB+ Caulk or FB-3000 WT Sealant INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL CERTIFICATION RESPECTIVELY. fd4" OA / EX DUCT THROUGH RATED WALL DETAIL 9 NOT TO SCALE SYSTEM NUMBER-C-AJ-7076 OCTOBER 14, 2009 F RATING -2 HR T RATING -0 HR v SECTION A -A 1. FLOOR OR WALL ASSEMBLY -MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600 2400 KG/M3) CONCRETE. FLOOR ASSEMBLY MAY ALSO BE CONSTRUCTED OF ANY MIN 6 IN. THICK UL CLASSIFIED HOLLOW -CORE PRECAST CONCRETE UNITS'. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS'. MAX AREA OF OPENING 640 SO IN. (4129 CM2) WITH A MAX DIMENSION OF 321N. (812 MM). MAX AREA OF IN FLOORS CONSTRUCTED OF HOLLOW -CORE CONCRETE IS 49 SQ IN. (316 CM2 WITH A MAX DIMENSION OF 71N. (178 MM).SEE CONCRETE BLOCKS (CAZT) AND PRECAST CONCRETE UNITS (CFTV) CATEGORIES IN FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS. 2. STEEL DUCT - NOM 30 BY 18 IN. (762 BY 457 MM) (OR SMALLER) STEEL DUCT TO BE INSTALLED CONCENTRICALLY OR ECCENTRICALLY WITHIN OPENING. THE DUCT SHALL BE CONSTRUCTED AND REINFORCED IN ACCORDANCE WITH SMACNA CONSTRUCTION STANDARDS. ANNULAR SPACE BETWEEN DUCT AND PERIPHERY OF OPENING SHALL BE SHALL BE MIN O IN.(POINT CONTACT) TO MAX 21N. (51 MM). DUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. PACKING MATERIAL - MIN 3 IN. (76 MM) THICKNESS OF MIN 4 PCF OR 64111 MINERAL WOOL BATT INSULATION FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. IN FLOORS CONSTRUCTED OF HOLLOW -CORE CONCRETE, PACKING MATERIAL TO BE RECESSED FROM TOP AND BOTTOM SURFACES OF FLOOR AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. Al. FORMING MATERIAL' -AS AN ALTERNATE TO THE PACKING MATERIAL IN ITEM M, NOM 41N. (102 MM) WIDE STRIPS OF MIN 1/21N (13 MM) THICK COMPRESSIBLE MAT TO BE STACKED TO A THICKNESS GREATER THAN THE WIDTH OF THE ANNULAR SPACE AND COMPRESSION -FITTED, EDGE -FIRST, TO FILL THE ANNULAR SPACE TO A MIN 4 IN. (102 MM) DEPTH. TOP OF FORMING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS NECESSARY TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL. IN FLOORS CONSTRUCTED OF HOLLOW -CORE CONCRETE, FORMING MATERIAL TO BE RECESSED FROM TOP AND BOTTOM SURFACES OF FLOOR AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. 3M COMPANY - FIRE BARRIER PACKING MATERIAL. B. FILL, VOID OR CAVITY MATERIALS' -CAULK OR SEALANT - MIN 1/21N. (13 MM) THICKNESS OF CAULKAPPLIED WITHIN THE ANNULUS, FLUSH WITH TOP SURFACE OF FLOOR OR WITH BOTH SURFACES OF WALL. IN FLOORS CONSTRUCTED OF HOLLOW -CORE CONCRETE, MIN 1/21N. (13 MM) THICKNESS OF CAULK APPLIED WITHIN THE ANNULUS, FLUSH WITH TOP AND BOTTOM SURFACES OF FLOOR. MIN 1141N. (6 MM) DIAM BEAD OF CAULK APPLIED TO THE DUCT/CONCRETE INTERFACE AT THE POINT CONTACT LOCATION ON THE TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL OR HOLLOW -CORE CONCRETE. 3M COMPANY - IC 151 CP 25WB+CAULK, OR FB-3000 WT SEALAN. C. RETAINING ANGLES - MIN 16 GA GALV STEEL ANGLES SIZED TO LAP DUCT A MIN OF 2 IN. (51 MM) AND LAP PERIPHERY OF OPENING A MIN OF 1 IN. (25 MM). ANGLES ATTACHED TO ALL FOUR SIDES OF STEEL DUCT ON TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL WITH NO. 10 (OR LARGER) STEEL SHEET METAL SCREWS SPACED A MAX 1 IN. (25 MM) FROM EACH END AND MAX 6 IN. (152 MM) OC. ' INDICATES SUCH PRODUCTS SHALL BEAR THE UL OR CUL CERTIFICATION MARK FOR JURISDICTIONS EMPLOYING THE UL OR CUL CERTIFICATION RESPECTIVELY. RATED FLOOR/WALL PENETRATION DETAIL IV „ter r�cnuv CLEARANCE REQUIREMENT FOR CONDENSING UNITS (DIMENSION A) WIDTH OF EQUIP. (INCHES) CLEARANCE (INCHES) UPT024 14 25 TO 36 18 37 TO 48 24 49 TO 60 30 61&WIDER 48 BASE RAIL SYSTEM (TYPICAL) PROVIDE SPRING & NEOPRENE ISOLATOR RAILS UNDER UNIT (TYP.) HURRICANE STRAP 000 voJS ROOF EQUIPMENT SUPPORT ALL ROOF MOUNTED EQUIPMENT MUST ADHERE TO CURRENT HURRICANE CODES REGARDING ROOF TIE-IN AND WIND RESISTANCE. CONDENSING UNIT MOUNTING DETAIL LV NOT NUSE BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 wWw.base-4.corn RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF isi EHh o.m Oc.x N 12 o AE 90 . 01I PNP.I �g4RONAL E�` DATE: 2019.03.04 GARRY VERMMS. PhD. PE Owner: THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOMEN, SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO. DELTA I ISSUED DATE I DESCRIPTION 1 MO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY DIRT CHECKED BY GWV PROJECT NO. B4-134-1705 SHEET NAME DETAILS-2 DRAWINGS NO. M -102