Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M-201 - 1ST FLOOR MECHANICAL PLAN
3.1 10 18 Will 11 9'_1014• 13 9'-101 Al" 9'-914' 9'-9v6 17 18 100 19 20 21 10'-0' I I I I I I I I I I I I I I I I I I I I I 9'- 10'- 4" AV AV g. 3' 9, 3' Ell A AV AV 9' -1 12' rill K 11 (K ; UNISEX J 9 5' S 48x6 9'-11 Wall 9'- 3/4" 9'-8 N4.24x6 CU 172 DS-1 - - - _ 1 27o 1 65 O 11 7 1 QtLL QOU_ _ _ _ _ _ MILL FINISH _ _ _ CU 3 - - - - ESTIFUJI A 12x12 LOUVER i6"xifi" STORAGE POOL cu FOOD 139 1 50 73 -e H PREP/STORAGE x : �' •x FD © © 16"xl © EQUI AREA _ o o a io 1 - C 161 r-------- 145 18x14 20"x 14" HIJ_.g r - --STAIR#2-1 12"x8" 12"x14 % - - - - - 10 200 9'-91W' 1 50 E 12x12 E HAUST �JENT 2 x24 x is F F 18 x fi' 9'- 1 3/a" EF-1 1 70 181 12x 50 to a 12"<' _ • 1 �D r + (TYPICAL) 9'-8314' 10-01/2 0 9'-0' 9'-9 --- ---- 8"x8" 10'-01/2" FDA F 10'-2114' --' ----i 10I-01/2" A 12X12 INDOORPOOL CCU-2 --- ----' ( ) m 101-0314' / 1 50 E0 9'-11114" 15 Ell 9'-01//4 1 50 Oj I x 1U-212- �I "B WOMENS 101/4' D E 12x12 �CUL 8'-103r4" --i 10 x8 L �w DS-3 I 6"x4 10'-4' 1 100 u (MEETING S 48x6 1 SERVERYI BREAKFAST 5 260 174 r 6"XX T-111/2' 10'-4112' 164 I 138 9' 11" 9,-11' III 10'-�¢' 91-11' 1 i III11 1 3606 2 70 9-0/a" 910'9111 T R 15602 ODU-1 4 xfi x6 I 14'k18"ERV 22R12'pW 1 A 24x24 8 112' 11P-01/2' PC OLY ST, CORR. SUPPLY DUCTU _ O INTAKt O 2 250 - 1 110 I� _ _ 1 10' POOCH R 48x6 _� 1 1S 9'-11114' 9'-01/4' 100.2 14"x14"ERV 5 1 255 AHU CLOSET � 169 .o _ ACCU 160 CUH AHU-1 I 10'-01/4' 10'- 1/4' 12"x12' 10'-01/a" 9'-03/4" EXHAUSTDUCTUP _ D jj o 10"x10" ERV SUPPLY 143A - - - 24x6 4'x4 -- - - MILL FINISH LOUVER DUCT UP 1 - ° 9'-61/4" Th R 48x6 R 48x6 18'xfi' T ® ® - 12x12 14'k14" -� 1 so Oo11u s-1oa/a" FD x 9 "x10 - FO 1 355 2 Sao (TVPI AL) PD x 8'-111/4' x 26"x12" F "x6" 1 70 IJI1} _ 9' -10' E CORR. 16"x10"ERV - 9'-111/2" T S 3fixfi x - -&3/4- E 100.1 EXHAUST DIJTUP .x4, 6 19-1114 2 100 2 100 9'-23/4' u 9'-31/4" 8'-113/4' x 10 8"x " 2x 2 - 9'-41/a" a fi'x4' 12"1 "B 50 1 9'-5114" x10' _ 2 •x4• 9' - ] 314' 10"x8" 10"x10" - v 82 300 - - - '-61/4" 12" 1 14 Wei m B 24x24 12'x " ❑p D 1 235 - CU _ 10 1 90 NPI L 14'x1 ' o rik 9'-6114 9'-0314' 9' 53/4" 1 -11' --05 SALE30FFICE 8'B S 48x6 "X10" � - B 2 x24 8'-61/2" T ry B 12x12� E 4 6 12"x6" FD pi 1 B 24x24 GUEST Ell MANAGERS FCU-2� 9'-p• 24x24 9'-9" 9'-8' ELEV#1 2 430 LAU DRV 8'-111/a" x 1 25 1 300 --- AUNDRV 1 147 1 130 1 135 -10" 9'- 0' A 2x 2 II 1 90 OFFICE 1 0_ 8' 232 LINEN 9 50 F 1- x2 10 x� ___yii --- STORAGE m 14'x14' 2x2 ii 157 8'-11" 146 m - x m LOBBY A 24x24 S 3fix A 24x24 --�°r T --- m io REGISSTRATION 6 170 ELEV#2 8' 111/4' 171 4"x12' F '-1131 1 210 1 105 �---yii ENGINEERING A 24x24 bESK 132 1 100 23 4 240 FD _ P ROOM 1 ifi5 136 ° iP-11/2' 10'-21/4 m 1P-21/4" 8'B 2'x14' 8' 14 m P -_-_-_ 158 9'-1114" 10' 10' E 24x24 -113 ° • 9'-1 3I4" m 8'-912'1'�� _ _ C m 9'-11374 n - 3TAI 3#1 1l2' m ELEV LOBBY O WORK 1 100 1P-11/2" 10-21/4 21/a" 127 a 95-81/2" 1 f E 24x24 18 - STATIONS 10'------ - 148 9'-11/' A 24x2 o 9'-1114' R' 24x24 1 280 B - - - MECH. - 8"x10" 0 _Y4'XI—Y4'xT4' T _ - _ - 9,-ip, K 9'=TTT74' 1P-0•' - B A 4X24 E 24x24 F 6"x6' - 10'-01/2' UH 9'-10314" 149 9' - - Q m - 9' - 9' 1 150 0 12" �FO %EMPLOYEE• -61/4' 1 340 i CU MECH. 6 FITNESS ROOM 12"x6" OBZ-i EMPLOYEE A 2a024 100 EXHAUST VENT 610 9'-8314' VESTIBULE O - 135 O 153 D (T16M"sEL S•x12' 156 �-� EC B 4 x o134 gu36x6 AHU-3 D y 2"x12"x 9'-4' ELECTRICAL u E2 24x6 2 150 10'-01/2' o _ _ BF - 1 1 %3 - A.1 AtR-tNTAKE -2 GWH-4 CARTSTRG. �_101/2+ LINT COLLECT R 2 3 DRY- S -10 WALLCAP ( q GWH-i GWH-3 GWH-5 HOME2 O MODEL OPL308 10"x10" 133 i 170 MARKET WALLCAP 10'-3114' 137 22'k1 9'-01IY 9'-01/4" 9-31PP 9'-1031' 9'-8314" AV 10 0' ® 9'-io" IF -10111 I '-113k' AV I I I I I I I I I I I I I I I I I I I I 3.1 1'6.. 68 O 10 11 12 13 14 15 16 17 18 100 19 20 21 1ST FLOOR MECHANICAL PLAN �1/811 = 11.011= 1'-011 GENERAL MECHANICAL NOTES 1 CONDENSING UNITS TO BE MOUNTED AND LEVELED ON PRE -FABRICATED CONCRETE PADS. 15 ALL DUCTS LOCATED IN UNCONDITIONED SPACES MUST HAVE INSULATION. SUPPLY AIR DUCTS FOR SPLIT SYSTEMS, DELIVERING COLD AIR, MUST HAVE INSULATION. OUTSIDE AIR DUCTS, DELIVERING 2 SUPPLY RUNOUTS TO DIFFUSERS SHALL BE THE SAME SIZE AS THE EQUIPMENT CONNECTION UNLESS OTHERWISE NOTED. NEUTRAL AIR, LOCATED IN CONDITIONED SPACES ARE NOT REQUIRED TO HAVE INSULATION, BUT CONTRACTOR SHALL CONFIRM WITH OWNER. EXHAUST DUCTS SHALL NOT BE INSULATED. 3 REFER TO MANUFACTURER'S RECOMMENDATIONS FOR REFRIGERANT PIPE SIZING. 16 PROVIDE GUEST ROOM THERMOSTAT WITH TWO SPEED FAN CONTROL CAPABILITY. 4 THERMOSTATS FOR ALL PTAC AND DX SYSTEMS SHALL BE MANUFACTURER'S STADARD WIRED T-STAT. THERMOSTAT BOX TO BE HORIZONTAL. IN PUBLIC SPACES PLACE IN AREAS NOT ACCESSIBLE TO GUESTS. CONTRACTOR SHALL PROVIDE 17 ALL DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM. ADDITIONAL BID LINE ITEM FOR INCOMM, VERDANT AND SCHNEIDER (FOR SCHNEIDER CONTACT CHRIS HINTON AT407-34(3-8827). 18 EXTERIOR DUCTS SHALL BE WRAPPED WITH 2" INSULATION WITH POLVGUARD(ALUMAGUARD)SELF- 5 ALL THERMOSTAT SHALL HAVE A 50F DEADBAND WITH AUTOMATIC CONTROLS CAPABLE OF SETBACK TO 55"F (HEAT) & 85"F ADHESIVE SELF -HEALING MEMBRANE WITH WATERSHED DESIGN OR EQUAL. (COOL). 19 CONTRACTOR SHALL PROVIDE ALUMINUM DUCTS WITHOUT INSULATION FOR POOLAREA. 6 PAINT INSIDE OF ALL RETURN GRILLES BLACK. 20 PAINT ALL EXTERIOR GRILLES/LOUVERS TO MATCH BUILDING COLOR. 7 ELECTRICAL CONTRACTOR SHOULD WIRE THE DUCT MOUNTED SMOKE DAMPER/DETECTOR. MECHANICAL CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR. 21 PROVIDE RADIANT DAMPERS AND RATED DIFFUSERSIGRILLES ON THE TERMINALS INSTALLED IN RATED ASSEMBLIES. 8 EACH GUEST ROOM EXHAUSTWILL HAVE 4" ROUND DUCT TO SHAFT. MAIN EXHAUST DUCTS THROUGH SHAFT TO ROOF AND CONNECTED TO ERV. SEE IMC SECTION 607.5.5. 22 CONTRACTOR SHALL PROVIDE THE OWNER WITH A CREDIT LINE ITEM FOR FIBERGLASS INSULATION IN LIEU OF ELASTOMERIC INSULATION IF ALLOWED BY BRAND STANDARD. 9 4" OUTSIDE AIR DUCTTO GUESTROOMS TO BE 26 GAUGE(0.55 MM) STEEL IN THICKNESS. 23 CONTRACTOR SHALL PROVIDE VOLUME CONTROL DAMPER ON ALL BRANCHES. CONTRACTOR CAN USE 10 4' EXHAUSTAIR DUCT FROM GUESTROOM TOILET TO BE 26 GAUGE (0.551 STEEL IN THICKNESS. CABLE OPERATED DAMPERS IN HARD CEILING WHERE ACCESS PANELS ARE NOT AVAILABLE. 11 ALL THERMOSTATS IN GUEST COMMON AREAS SHALL INCLUDE LOCKABLE CLEAR PLASTIC THERMOSTAT GUARD. 24 THE FRANCHISE BRAND STANDARDS DESIGN DOCUMENT SHALL BE CONSIDER AS AN INTEGRAL PART OF THE CONSTRUCTION DOCUMENTS. ALL CONTRACTORS SHALL ENSURE THEY OBTAIN, READ, AND RELEASED FOR CONSTRUCTION {OORDINATEWITHEORSHALL STATE FOR PLACEMENT OFCOSENSORS WITH DOCUMENT IFTHEREA EANYDESCREP NCESSHOWNONPLANSTATUTES THROUGHOUT THECONST UCTIONSTAGESSTANDARD THEREA EANY DISCREPANCIES BETWEEN THE R1/0,4 Subject to compliance with all regulations CONSTRUCON DOCUMENTS AND THE FRANCHISE BRAND STANDARDS, THE CONTRACTOR SHALL ISSUE 31NATION OF CO/SMOKE DETECTORS WILL BE USED AT ALL SMOKE DETECTOR LOCATION. REFER ELECTRICAL DRAWING AN RFI TO THE AOR AND EOR. of State and Local Codes 30 SMOKE DETECTOR LOCATION. City of Camel TRACTOR CAN USE DETAIL 16 & 19 ON SHEET 102 TO ELIMINATE FIRE DAMPERS IN RATED WALLS/SHAFTS. TRACTOR TO CONFIRM WITH OWNER. x DATE: 07/22/19 KEY NOTES-201 ® TEXT 1 ALL AHU/FCU/DHU/DS UNITS CONDENSATE DRAINS TO BE RELEASED ABOVE GRADE. 2 DRYER EXHAUST MANIFOLD TERMINATED WITH WALL CAP. CONTRACTOR SHALL COORDINATE WITH MANUFACTURER FOR SIZE (S) AND INSTALLATION INSTRUCTIONS. 3 56"x26' ARCHITECTURAL LOUVER FOR DRYER COMBUSTION AIR INTAKE. MECHANICAL CONTRACTOR TO PROVIDE MOTORIZED DAMPER INTERLOCKED WITH DRYER OPERATION. REFER DETAIL NO. 12 ON SHEET M-102. 4 MECHANICAL CONTRACTOR TO PROVIDE MANUFACTURER'S VENTING KIT. 5 OPTIONAL CABINET UNIT HEATER. OWNER TO DECIDE IF CUH'S ARE REQUIRED. 6 OPTIONAL ELECTRIC UNIT HEATER FOR LAUNDRY COMBUSTION AIR. CONTRACTOR TO CONFIRM WITH THE OWNER. 7 TEMPERATURE AND RELATIVE HUMIDITY ALARM DEVICE (EXTECH MODEL445815 OR EQUAL) THAT WILL NOTIFY STAFF VIA VISUAL AND AUDIBLE ALARM OF A TEMP/HUMIDITY ISSUE. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base4.cc m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QPit;\si EHh� i 1 12 o ATE OF "'l:OIPH. 2 �gBrONAL ��` DATE : 2019.03.04 Gi YERMM9. Phi PE F"NKI IN IN MJ Owner: /W�a�I1 t; THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWISCENTER,OH 513 513-fi23-9430-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO. DELTA I ISSUED DATE DESCRIPTION 1 MO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY DIRT CHECKED BY GWV PROJECT NO. B4-134-1705 SHEET NAME 1 ST FLOOR MECHANICAL PLAN DRAWINGS NO. M=201