Loading...
HomeMy WebLinkAboutM-202 - 2ND FLOOR MECHANICAL PLANB'-81/B'-9314" 8'-931' 8'-1031 8'-1 31 (TYPICAL) (TYPICAL) 5(3 4 —PTAI Pi—�PTAC- r�.a ova o+--rn Pi _ 17 U — PTAC-1 PTAGi — — — — _ CC. KING ONE QUEEN BEDROOM QUEEN/ QUEEN/ QUEEN/ QUEEN STIL DID R.I.S KING STUDIO QUEEN STUDIO QUEEN STUDIO QUEEN STUDIO CONNECT G 201 203 205 207 209 211 D2 x 16"x10" ERV TYPICAL) 1 40 EXHAUST DUCT 02 406 S JAIR#2 T0"i8kT ERV SUPPLYDUCT UP10"x IS � FD 8'-70712' T ITT T T T T I 100T 20 l 21 I I I I I I I I I I I I I I I I I I 8'-9314• F- 1 311 8'-93k• II I I I I I PTAC-1 — PTAC-1 PTAC-0 — PTAC-1 PTAC-1 — I I ACC-QDEENI L _ QUEEN STUDIO ® KING ONE CONNECTING KING STUDIO KING STUDIO KINGS UDIO 1 35 BEDROOM 213 215 217 21 221 (TYPICAL) D E1 8x8 Inv T 25 kB" to T14"x14" ERVA 12x121 140 EXHAUSTDUCT 50 UP'- 0314'8 10"STORAGE 18"xi8" ERV SUS LV DUCTUP m mm e < 231 — < < — — — — 9 1l2' E S 38x8 o x x 8'-7' TEE "I ' I8" EXHAUST 2 fik4' 4"x6" b e o FED x4^ 8,_ p di D CTUP ml E 125^2 m �: T s e <.J p•xe < ST IR#1 _. 0 LOBBY 227 (TYPICALJ— — — —LKNT9I LKlffTkSmTU)l0- 22Ilk A 9072u — — — — — — — ELEV ACC. KING 711700 371 STUDIO KING STUDIO CONNECTING NNECTINt� KING STUDIO KING STUDIO —KIRG-STUDC KBSGSTUDD G-S STUDi� KIRGSTUDIO202 204 206 208 B E 12xJ2OUS230EPING 216 218 220 222 224 FD 1 140 1 so _ PTAC-2 PTAC-1 PTAC-1 PTAC-1 PT6 AC-1 PTAC- PTAC-1 PTAC-1 PTAC-1 PTAC-1 PTAC-1 "e ERV EX IIAUST DUCT UP 3 4 (TYPICAL) 5 A &'- (TYPICAL) -4 8-4 B'-9112• 8'-10814• 11114' 8'-4 112" 8'-31/2" 8'-10' I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 3.1 10 11 12 13 14 15 i6 17 18 100 19 20 21 2ND FLOOR MECHANICAL PLAN ' 1/811 = 11.011 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel ((�� Avm 'Ubw nla101L x DATE: 07/22/19 KEY NOTES-202 TEXT 1 EXHAUST W ILL BE EXTENDED AT LEAST 22" VERTICALLY IN EXHAUST SHAFT/CHASE. REFER DETAIL NO.07 ON SHEET M-101. 2 MECHANICAL CONTRACTOR TO COORDINATE TSTAT LOCATION AS PER ID. 3 ELBOW CONDENSATE DRAIN CONNECT TO NEAREST CONDENSATE RISER. TYPICAL FOR ALL PTAC UNITS UNLESS NOTED OTHERWISE. 4 NO OUTDOOR AIR TO B E B ROUG HT I NTO ROOM TH ROUGH PTAC UNITS. FRESH AIR CONTROL ARM TO BE CLOSED. TY PICAL FOR ALL PTAC UNITS. 5 ALL CONDENSATE DRAINS TO BE RELEASED ABOVE GRADE. GC TO ENSURE A MIN. SLOPE OF 1/8" PER FT IS MAINTAINED. TYPICAL FOR ALL CONDENSATE RISER DOWN. Wit" CONDENSATE RISER UP. SEE UPPER FLOOR PLANS FOR CONTINUATION. TYPICAL FOR ALL PTAC UNITS CONDENSATE DRAINAGE UNLESS NOTED OTHERWISE. BAS E'' BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.com RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VS' EHh� N 1 12 o ATE 90 . 01I PNP:'2b �g4rONAL ��` DATE: 201903e4 GARRY VERMAAS. Phi PE Owner: tl r e THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWISCE H 513 -fi23-9430-9430 513 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO. DELTA I ISSUED DATE DESCRIPTION 1 MO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY DIRT CHECKED BY GWV PROJECT NO 134-134-1705 SHEET NAME 2ND FLOOR MECHANICAL PLAN DRAWINGS NO. M=202