HomeMy WebLinkAboutM-301 - SCHEDULESAIR CONDITIONING SPLIT SYSTEM EQUIPMENT SCHEDULE CONDENSING UNIT NOMINAL TOTAL SENSIBLE WEIGHT LxWxH CU TAG MANUFACTURER BMODEL COOLING COOLING VOLTAGE/PH MCA MOCP FAN HP/FLA EER NOTES TONNAGE BTUH BTUH (LBS) (IN) CU-1 TRANE If4TTL6024 2B 21,940 19,514 208/1/60 13B 20B 0.083/0.54 13B 165 40x14x36 1TO6 CU-2 TRANE If 4TTR6060 5.0 52,713 40,292 20811160 32.0 50.0 0.20/1.05 12.0 327 38x34x46 1TO6 CU-3 TRANE/4TTI6048 4.0 44.522 34.750 208/1/60 24.0 40.0 0.20/1AIS 12.5 243 47xl8x36 1TO6 CU4 TRANS If 4TTR6030 2.5 27,215 23,622 208/1/60 17.0 25.0 0.126/0.64 14.0 184 32x3Ox36 1TO6 CU-5 TRANS/4TTL6048 4.0 44,522 34,750 208/1/60 24.0 40.0 0.20/1.18 12.5 243 47xi8x36 1TO6 AIR HANDLING UNIT NOMINAL TOTAL MIN MINCIA ELECTRIC HEAT WEIGHT LxWxH II AHU TAG MANUFACTURER B MODEL EAT DBIWB VOLTAGE/PWZ MCA MOCP FAN HPIFLA EER NOTES TONNAGE CFM INPUT(kW) CIRCUIT (LBS) (IN) AHU-1 TRANE/GAM5BOA24M 2.0 840 85 75.0/60.90 208I1I60 4.80 1 29.0 30.0 0.33/2.8 13.0 126 22x18x52 7, 8, 9, 11, 12,13 AHU-2 TRANE/GAM5BOC60M 5.0 1795 610 75.0/62.40 208/1/60 19.20 2 110.0 110.0 1.0/7.6 12.0 180 62x24x22 7, 8, 10, 11, 12,13 AHU-3 TRANE1GAM5BOC48M 4.0 1605 395 75.0/6Z80 20811160 9.60 1 58.0 60.0 0.75/6.0 12.5 176 24x22xfi2 7, 8, 9, 11, 12,13 AHU4 TRANE/GAM51301330M 2.5 1000 115 75.0/61.20 208W60 4.80 1 29.0 30.0 0.33/2.8 14.0 140 22x1 7, 8, 9, 11, 12,13 AHU-5 TRANE/GAM5B0C48M 4.0 1605 395 75.0/62.80 208/1/60 4.80 1 33.0 35.0 0.75/6.0 12.5 176 62x24x22 7, 8, 10, 11, 12,13 NOTES: 1. PROVIDE WITH THERMAL EXPANSION VALVES, LIQUID LINE FILTER DRYER AND MULTI -USE SERVICE VALVES. 9. VERTICAL INSTALLATION OF AHU. 2. PROVIDE COMPRESSOR WITH CRANKCASE HEATER AND MIN. 5-YEAR WARRANTY. 10. HORIZONTAL INSTALLATION OF AHU. 3. PROVIDE HIGH AND LOW PRESSURE CONTROL AND OVER TEMPERATURE PROTECTION. 11. PROVIDE 1"THROWAWAY, MIN. 30% EFF. FILTER AND VIBRATION ISOLATION FOR AHU. 4. PROVIDE WEATHERPROOF ELECTRIC CONTROLS AND SINGLE SIDE SERVICE ACCESS. 12. UNITS SHALL INCLUDE MICROPROCESSOR CONTROLS THAT MINIMIZE SUPPLEMENTAL 5. COORDINATE WITH MANUFACTURER FOR THE ALLOWED MAXIMUM LENGTH OF HEAT USAGE DURING START-UP, SET-UP, AND DEFROST CONDITIONS. REFRIGERANT SUCTION AND LIQUID LINES PRIOR TO PURCHASE. 13, APPROVED EQUALS ARE ACCEPTABLE. 6. "CONTACT THE TRANE LODGING TEAM AT LODGING®TRANE.COM OR CALL I-800-2294178." 7. PROVIDE DISCONNECT/STARTER FOR A.H.U./CU. POWER TO FEED FROM CU DOWN TO AHU. COORDINATE WITH ELECTRICAL CONTRACTOR PRIOR TO PURCHASING. 8. PROVIDE FACTORY PROGRAMMABLE THERMOSTAT TO MATCH CAPACITY STAGES. PACKAGED TERMINAL AIR CONDITIONER SCHEDULE SUPPLY - FAN DATA COOLING ELEC. AUXILIARYHEAT ELEC. DATA UNIT AREA EER MANUFACTURER REVERSE CYCLE WEIGHT Lx WH NO, LOCATION SERVED pry TOTAL FAN TOTAL BMODEL NO. HEAT (BTUH) INPUT OUTPUT VOLT/PH VOLT/PH MOCP (LBS) (IN)) NOTES CFM RPM MBH KW MBH PI WALL GUEST ROOM 72 4]0 BV 77 122 PREMAIRE& 61100 3.0 10.2 208V/10 208V/10 20 145 42xl4xl6 1T07 MFG PTW0723H3G PTAC-2 WALL GUEST ROOM 24 470 BY 90 114 PREMAIRE& 8,100 3.0 10.2 20W110 20BV110 20 145 42xl4xl6 1TO7 MFG PTW0923H3G NOTES: 1. WALL CASE 8 ARCHITECTURAL LOUVER COORD. COLOR WITH ARCHITECT 5. CONDENSATE'SLINGER' ( ) 2. ELECTRICAL CONNECTION KIT (208 VOLT) 6.SAUERMANN MINI INLINE CONDENSATE PUMP TO BE INSTALLED ON UNITS WHERE 1/8"MIN. SLOPE 3. CONDENSATE DRAIN, ROUTED IN MAIN DOWN WALL 8 EXTERIOR. CANNOT BE MAINTAINED TO DISPOSAL POINT. INSTALL PUMP CONCEALED IN UNIT. 4. WALL THERMOSTATS LOCATED PER ELECTRICAL S PROVIDE VERDANT/INCOMM BRAND WIRED 7. PROVIDE SLEEVE DRAIN KIT TSYS TSTAT.STANO-ALONE PTAC ENERGY MANAGEMENT SYSTEM. AIR CONDITIONING MINI SPLIT EQUIPMENT SCHEDULE OUTDOOR (CONDENSING) UNIT NOMINAL TOTAL TOTAL WEIGHT WxDxH TAG MANUFACTURER& MODEL OTY COOLING HEATING FLA VOLTAGE/PH MCA MOCP SEER NOTES TONNAGE (BTUH) BTUH (LBS) (IN) CCU-1 MITSUBISHI/PUY-Al2NKA7 1 1.0 12,000 - 0.5 208/10 11.0 30.0 20.6 92 32x12x24 ATOP CCU-2 MITSUBISHI/PUZ-Al2NKA] 1 16 12,000 9,200 0.5 208/10 11.0 306 20A 93 32x12x24 ATOP CCU3 MITSUBISHI I PUZ-Al2NKA7 1 2.0 24,000 15,700 0.4 208110 19.0 26.0 21.4 153 38x14x38 ATOP INDOOR (AIR HANDLING) UNIT TAG MANUFACTURER& MODEL QTY NOMINAL TOTAL VOLTAGE/PH/Z HEATING BTUH ( ) MCA FAN FLA SEER WEIGHT WxDxH NOTES TONNAGE CFM (LBS) (IN) DS-1 MITSUBISHI /PKA-Al2HA7 1 1.0 320-370425 208/1/60 - 1.0 0.33 20.8 29 3fix10x12 GTOJ DS-2 MITSUBISHI/PKA-Al2HA7 1 1.0 320-370425 208/1/60 9,200 1.0 0.33 20.8 29 3fix10x12 GTOJ DS-3 MITSUBISHI/PKA-A24KA7 1 2.0 635-705-775 208/1/60 15,700 1.0 0.36 21.4 4fi 46xl2xl6 GTOJ CONDENSING UNIT ACCESSORIES: FAN COIL UNIT ACCESSORIES: A. MOUNTING CURB E. CORROSION RESISTANT COIL (IN COSTAL AREAS) I. INDOOR UNIT MUST BE CONNECTED TO OUTDOOR UNIT. SEE OUTDOOR UNIT FOR DATA. B. LOW AMBIENT COOLING TOO DEG F F. EXTENDED REFRIGERANT LINE KIT J. APPROVED EQUALS ARE ACCEPTABLE. C COIL GUARDS G. INTEGRAL CONDENSATE PUMP K. FOR MITSUBISHI NATIONAL ACCOUNT PRICING CALL DAN PABST AT-608-6304371. D. SERVICE VALVES H. WALL MOUNT TDAY PROGRAMABLE T-STAT (NO REMOTE) POOL DEHUMIDIFICATION UNIT SCHEDULE COOLONG RETURN AIR MOISTURE AUXILLARY ELECTRICAL DATA ESTIMATED MARK MANUFACTURER& TOTALAIR MINIMUM SUPPLYAIR CAPACITY TEMPERATUR REMOVAL HEAT RELATIVE REFRIGERAN MOTOR SIZE WEIGHT MODEL NO. FLOW(CFM) O.A.(CFM) E.S.P(IN H2O) HE MBH E F CAPACITY LBSIHR CAPACITY (EDH) HUMIDITY(%) TYPE HE VOLTIPHIZ MCA MOCP (LxWxH) LBS SERESCO DHU-1 NE-004-PV-1-A3NT 2000 440 1B 2.2 53.3 82 23.7 17.5 kW 60 R410A 2.2 208/3/60 88 90 40x42x86 860 1202E5C2AE0 OUTDOOR (CONDENSING) UNIT FOR DHU HEAT REJECTION WEIGHT(LBS) REMARKS MARK TYPE FLA MCA MOCP MOTOR HE VOLTAGE/PWHZ LxWxH MBTUH ACCU-1 SERESCO NC-B-1V-CUC-V 66.6 2.6 4.0 15.0 0.60 208/3(60 32x34x30 90 1 NOTE: 1.FURNISH W/MICROPROCESSOR CONTROLS AND SPACE TEMPERATURE AND HUMIDITY SENSORS. 4. COORDINATE INSTALLATION W/POOL EQUIPMENT CONTRACTOR. 2.UNIT TO BE FLOOR MOUNTED. 5.CONTACT SERESCO NATIONAL ACCOUNT SERVICES((613) 741-3603) FOR PRICING INSTALLATION INFORMATION. 3.PROVIDE OUTSIDE AIR CONNECTION. ERV UNIT SCHEDULE FAN COIL UNIT SCHEDULE OUTDOOR UNIT NOMINAL TOTAL TOTAL TOTAL WEIGHT LXWXH UNIT TAG MANUFACTURERS MODEL QTY COOLING HEATING INPUT VOLTAGE/PH MCA MOCP SEER NOTES TONNAGE (BTUH) BTUH (KW) (LBS) (IN) ODU-1/2 MITSUBISHI/PUZ-Al2NKA7 2 1.0 12,000 8,700 1.03 208/10 11.0 30.0 21,1 93 32xl2x24 ATOP INDOOR UNIT NOMINAL TOTAL HEATPUMP WEIGHT WxDxH UNIT TAG MANUFACTURERS MODEL QTY TONNAGE CFM VOLTAGF/PH/Z MCA FAN MOTOR/FLA SEER (LBS) (IN) NOTES HEATING (BTUH) FCU-1/2 MITSUBISHI/PEAD-Al2AA7 2 1 1.0 342/415 208/1/60 1 8,700 1.45 85W/1.18 1 21.1 1 58 1 36x29x10 GTOI CONDENSING UNIT ACCESSORIES: FAN COIL UNIT ACCESSORIES: A. MOUNTING CURB D. SERVICE VALVES G. INTEGRAL CONDENSATE PUMP B. LOW AMBIENT COOLING TO 0 DEG F E. CORROSION RESISTANT COIL (IN COSTAL AREAS) H. WALL MOUNT 7-DAY PROGRAMABLE T-STAT (NO REMOTE) C. COIL GUARDS F. EXTENDED REFRIGERANT LINE KIT I. INDOOR UNIT MUST BE CONNECTED TO OUTDOOR UNIT. SEE OUTDOOR UNIT FOR DATA. J. FOR MITSUBISHI NATIONAL ACCOUNT PRICING CALL DAN PABST AT- 608-630-4371. SUPPLY/EXHAUST FAN SCHEDULE FAN SERVICE INSTALL MANUF.& CFM MOTOR I S.P. HVI VOLTS- WEIGHT NOTES NO. LOCATION MODEL SONES PH (LBS) EF-1 INDOOR POOL CEILING COOK /GC-720 550 301W 0.125" 6.6 120-10 36 1,2,3&4 EF-2 ELEVATOR ROOF COOK/70CPV 1 450 1 0.158BHP 0.250" - 120-10 164 1.2.3.5.6&7 NOTES: 1. BACKDRAFT DAMPER. 4. LOUVER MOUNT AT LEAST 10' ABOVE GRADE. PAINT TO MATCH EXTERIOR. 2. PREW IRED FAN SPEED CONTROLLER. 5. UNIT SHALL BEAR AN ENGRAVED ALUMINIUM NAMEPLATE. 3. FAN TO RUN CONTINUOUSLY. UNLESS OTHERWISE NOTED. 6. MOTOR MOUNT SHALL BE MINIMUM 14 GAUGE STEEL. 7. THE FAN HOUSING SHALL HAVE AIR TIGHT LOCK SEAMS AND SHALL BE FIELD ROTATBLE TO ANY ONE OF EIGHT DISCHARGE POSITIONS. BOOSTER FAN SCHEDULE MARK QTY. MANUFACTURER MODEL NO. CFM AMP W VOLTS -PH WEIGHT ES. BE 1 FANTECH DBL4XL 190 0.54 64.8 120-10 10 UNIT HEATER SCHEDULE (ELECTRIC) MARK ANUFACTURER MODELNO. TYPE CFM CAP RPM EAT AMP KW OLTS-PH LX REMARKS (MBH) NxH LBS CUH REDD-I AFA848D cUMIPAUt MOUNTED 175 16.56 600 65 23 4.8 208-10 14x4x20 26 1TO4 UH REDD-I FEP4620-3RA SURFACE MOUNTED 2954 - 65 21.1 7.6 208J0 58x9x18 85 1T04 NOTES: 1. BUILT-IN DISCONNECT SWITCH. 3. BUILT-IN FAN DELAY SWITCH. 2. BUILT-IN THERMOSTAT. 4. APPROVED EQUALS PER SPECS. POP VENT EXHAUST SCHEDULE MARK QTY. MANUFACTURER MODEL NO. APPLICATION PER WEIGHT SQ. FOOT LBS. ACTIVE VENTILATION AV 4 PRODUCT INC pV-12-CO2 225 4 GRILLE &DIFFUSER SCHEDULE TAG MANUFACTURER MODEL FRAME OR BORDERTYPE MODULE SIZE DAMPER MODELNO FINISH A TITUS TDC LAY IN SURFACE 24x24 N/A WHITE B TITUS PAR LAY IN SURFACE 24x24 NIA WHITE BRIE TITUS CT480 SEE PLANS NIA WHITE TO TITUS CT-700 -- SEE PLANS N/A WHITE CSICR TITUS 272FL&3FL SEE PLANS N/A WHITE MS/MR TITUS ML-38/MLR-38 SEE PLANS N/A WHITE D AMERICAN ALDES CSRB-WB-II SEE PLANS N/A WHITE Ei I AMERICANALDES CERB-CS-II SEE PLANS NIA WHITE E2 TITUS MLR-38 SEE PLANS N/A WHITE NOTES: 1. ALL CEILING DIFFUSERS ARE AWAY THROW UNLESS INDICATED OTHERWISE ON PLAN. 2. PROVIDE WITH MANUFACTURERS PLENUM. GENERAL NOTES: 1. PROVIDE SWITCHES AT OPERABLE WINDOWS TO SHUT DOWN UNIT WHEN WINDOW IS OPEN. 2. PROVIDE MERV-8 PREFILTERS AND MERV-12 FINAL FILTERS ATALL AIR HANDLING UNITS. 3. PROVIDE INDOOR AIR HANDLING UNITS, FAN COILS, OR STANDARD PACKAGED ROOFTOP UNITS WITH CLOSED -CELL ELASTOMERIC INSULATION. 4. PROVIDE UV PROTECTIVE COATING ON ALL ELASTOMERIC PIPEMUCT INSULATION WHERE EXPOSED TO SUNLIGHT. 5. SMOKE DETECTORS SHALL BE INSTALLED IN DOWNSTREAM OF SUPPLYAIR SYSTEMS (IN THE SUPPLYAIR DUCT) WITH A DESIGN CAPACITY GREATER THAN 2,000 CFM (0.9111 6. MECHANICAL CONTRACTOR TO PROVIDE FINAL FILTER FOR MAKE-UP AIR UNITS AND AS PER HOTEL STANDARD REQUIREMENTS FOUND IN THE BRAND STANDARD DESIGN MANUAL. ]. PROVIDE APPROVED BARRIERS FOR ALL EQUIPMENTS WHICH SUBJECTS TO MECHANICAL DAMAGE AS PER IMC 303.4. SUPPLYAIR ENERGYRECOVERYWHEEL COOLING GAS HEATING ELECTRICAL MARK EXH. MFG.B BLOWER MCA MOCP WEIGHT LxW xH NOTES E'S'P' SOPPY EXHAUST TOTAL SENS. IN OUT CFM CFM SUMMER EAT WINTER EAT EAT LAT EADB LADB VOLTSI PH MODEL (Hp) (LBS) (IN) (IN.WG.) CFM CFM (MBH) (MBH) (MBH) (MBH) ERV-1 3900 1 1.50 1 2900 3900 2900 83.0/74.5 -2.7 206.8 115.5 786/68.7 51.8/51.6 38.5 86.0 250.0 200.0 208/3/60 RVE40-41-30H-15S-1 5 92.5 110 3666 202x86x66 1TO13 ERV-2 4500 1 1.50 1 3800 4500 3800 83.0174.5 -2.7 228.9 131.3 77.8167.8 51.3r51.1 46.0 95.4 300.0 240.0 1 208/3160 IRVE-85-52-15H-17.5S-JI 5 1 98.3 1 125 1 5109 1224x98x76 1 TO 13 NOTES: (UNIT WILL SIZED BY GREENHECK REPRESENTATIVE RELEASED FOR CONSTRUCTION INS. Subject to compliance WA all regulations of State and meal Codes City of Camel ((�� �vm�' ilmnr)nD1J4L x DATE: 07/22/19 5. PHASE PROTECTION. 6. CONVENIENCE OUTLET. 7. UNIT TORUN CONTINUOUSLY. 8. INTEGRAL DISCONNECT. 9. COILGUARDS. 10. PROVIDE MANUAL SHUTDOWN SWITCH FOR ERV'S NEAR FIRE ALARM PANEL. 11. CORROSION RESISTANT COATING ON COILS (IN COASTAL AREAS). 12. PROVIDE FACTORY INSTALLED DUCT DETECTORS. 13. ENERGY WHEEL CASSETTE TO SLIDE OUT FOR SERVICIBILITY. REFRIGERANT PIPE INSULATION THICKNESS A. 1/2 INCH (13 MM) INSULATION FOR ONE INCH (25 MM) PIPE OUTSIDE DIAMETER AND SMALLER PIPE. B. 3/41NCH (19 MM) INSULATION FOR 1-1/8 THROUGH 21NCH (28 THROUGH 50 MM) PIPE OUTSIDE DIAMETER PIPE. C. ONE INCH (25 MM) INSULATION FOR 2-1/8 INCHES (53 MM) PIPE OUTSIDE DIAMETER AND LARGER PIPE (TWO LAYERS OF 12 INCH 13 MM). D. ONE INCH (25 MM) INSULATION SHEET FOR FITTINGS AS RECOMMENDED BY MANUFACTURER. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: H W VF QP��'\si EHh� o' m N 1 12 o ATE b 9O ...'1O I j N.. .. CBS TONAL El` DATE: W180304 GI Wn0d S. PhD. PE Owner: �; yr THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 E suirss BY xiHOMLrox CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 MO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY DIRT CHECKED BY GWV PROJECT NO, 134-134-1705 SHEET NAME SCHEDULES DRAWINGS NO. M=301