HomeMy WebLinkAboutP-102 - DETAILS-1 (2)PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE WASHER TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP LEANOUT WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET FINISHED GRADE WASHESANITARY OUTLET RS 02 ( ) WIDTH=16" MARKER, RECESSED FOR TILE, SCORWTED FOR UNFINISHED FLOORS). PROVIDE BRONZE PLUG IN CAST IRON BODY. RAIN TROUGH FLOOR SLAB ON GRADE —CONCRETE PAD — FLOOR LEVEL SAME SIZE AS SEWER �UP TO 6" MAXIMUM 16"X161IX6" CONCRETE PAD AS REQUIRED FOR DEPTH OF ONG SWEEP ELBOW AT LINT FILTER END OR TURN OF RUN. DETAIL SEWER HUB AND SPIGOT CAST IRON PIPE BELOW FLOOR. COMBINATION WYE AND SANITARY OR STORM EIGHTH BEND IN RUN. SEWER LINE ENTER TOP OF PIPE. 1/8 BEND IF CD OCCURS AT END OF LINE DRAIN i� TROUGH SB3" SB3" DIRECTION OF FLOW REMOVABLE LINT FILTER ( LOCATION - TYPICAL) LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS a LENGTH=88" OF PIPE GREATER THAN 45 DEGREES,AT 10Y INTERVALS wo BOTTOM DRAIN ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER ARCHITECHTURAL SPECFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. -III III III III III III —III III III— �� CONSULT LOCAL CODES FOR OTHER FCO RE1 UIREMENTS. FLOOR CLEANOUT DETAIL CLEANOUT TO GRADE WASHER AND DRAIN TROUGH DETAIL O (� 7 V NOT TO SCALE NOT TO SCALEI NOT TO SCALE CONT, TO OTHER FLOORS CONT. TO OTHER FLOORS PTAC PTAC 3/4" PTAC CLEAN -OUT CLEAN -OUT CLEAN -OUT INISHED 3/4" 3/4" WALL SLOPE SLOPE INISHED FINISHED FINISHED SLOPE FLOOR FLOOR FLOOR EAD FLASHING 12" OUT AND TURNED UNDERFLANGE REMOVABLE ROOF DOME 3/4 PTAC 3/4 PTAC GRAVELSTOPAS REQUIRED I I PTAC ACCESS 30P PLATE 34" DO SLOPE SLOPE SLOPE no LEAN -OUT 3/4" 3/4" CONNECT TO THE CONNECT TO THE ADJUSTABLE COLLAR NEAREST STORM LINE. NEAREST STORM LINE. NOTES: 1. CONDENSATE PIPING FOR ALL UNITS ABOVE FIRST FLOOR ARE INSIDEWALL. - + 2. CONDENSATE DRAIN PIPING TO BE AS SPECIFIED PER PLUMBING PLANS, IF NOT SPECIFIED, TO BE ROOF DRAIN OVERFLOW ROOF DRAIN TYPE "L" COPPER OR PVC WHERE ALLOWED BY CODE WITH 12" ARMAFLEX INSULATION. 3. PROVIDE APPROVED WATER LEVEL DETECTOR OR FLOAT SWITCH TO AUTOMATICALLY SHUTDOWN NOTE: THE AIR CONDITIONING UNIT, AS A SECONDARY DRAIN SYSTEM TO COMPLY WITH MECHANICAL 1. CONTRACTOR SHALL VERIFY THAT INSTALLATION IS IN COMPLIANCE STATE BUILDING CODE. WITH ROOFING MANUFACTURERS RECOMMENDATIONS. END OF THE LINE TWO-WAY COMBINATION WYE AND EIGHT BEND WALL CLEANOUT 4. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP. 2. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ROOF 5. PITCH DRAIN FOR PROPER RUNOFF. CONSTRUCTION. 6. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM INITIAL DRAIN SEAL. 3. REFER TO SHEET P401 FOR RD/ORD SPECIFICATION. 7. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. 8. CONDENSATE DRAIN PIPING SHALL MAINTAIN A MINIMUM HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE NOT LESS THAN 1/8 UNIT VERTICAL IN 12 UNITS HORIZONTAL. FLOOR & WALL CLEANOUTS PTAC CONDENSATE DETAIL ROOF DRAIN DETAIL ^ 1 NOT TO SCALE 121 NOT TO SCALE MANHOLE FRAME WATERTIGHT FLEXIBLE BOOTS AND COVER HEAVY MUST BE USED AT ALL OPENINGS NOTE: METAL STUD METAL STUD 1. BASE MATERIAL: POLY CARBONATE STRAPSECURED CPVC DUTY: NEENAH _— _— —_ — R-1642A OR EQUALWATERTIGHT: 2. SIZE: THE DECK BASE IS 6" SQUARE, THE STACKING PLATFORM IS 2" HIGH, TO STUD NEENAH R-1916-F OR INLET THE TOP OF THE "U" CRADLE IS 3" HIGH, AND THE MAXIMUM INSIDE WIDTH (TYPICAL) ( ECURE BRASS ELBOW TO EQUAL INVERT OF THE CRADLE IS 1.95". WOOD BLOCKING WITH SCREW SAMPLE BOX "'n 3. MAX PIPE SIZE. 1-112" INSIDE DIAMETER AND 1-9/10" OUTSIDE DIAMETER. 4. MAX PIPE CLEARANCE: PIPES SUPPORTED ON PIPE STAND WILL HAVE A SHOWER HEAD 5. CLEARANCE OF 2" OVER THE ROOF. MAX LOAD WEIGHT: MAXIMUM LOAD OUTLET CONCRETE — INVERT :' ADJUSTING RINGS + + WEIGHT MAY NOT EXCEED 80 LBS. PER PIPE STAND. 6. SPACING: MANUFACTURER'S RECOMMENDED SPACING IS NOT TO — 6"A.F.F. LIMITED TO (3) RINGS. III EXCEED 10 FEET CENTERS DEPENDING UPON THE LOAD. — MAXIMUM COMBINED 7. USE 43/e"KWIK BOLT WITH 2"EMBEDMENT. —� BLOCKING HEIGHT — III 180" COPPER (FIRE TREATED OF 12". RINGS MUST III BE BUTYL WOOD) TRANSITION FROM PEX A TO RUBBER COATED - ALL SECTIONS MUST HAVE WOOD BLOCKING COPPER WITH PLASTIC WRAP MINIMUM IO MIL BITUMINOUS COVER. III COATING APPLIED TO ENTIRE + + IRE WOOD)REATED EXTERIOR. �p•-8"AF.F. SHOWER MIXING IIIIII VALVE - - COPPER 18'0"COPPER III STRAPS -I BED BASE SECTION IN MIN. 6" SECURED TO OOD SECURE BRASS ELBOW TO COMPACTED #B GRANULAR IIIIIZII-III-III-III-III-111' BLOCKING WOOD BLOCKING WITH SCREW MATERIAL (TYPICAL) _ III-III-IIIIIII III-III--I-I-I TOP VIEW A A.F.F. TUB FILLER ----- (COVERS 8 RISERS REMOVED) WOOD ____ F 1 F BLOCKING NOTES: I I I (FIRE TREATED WOOD) 1. REFER TO PLUMBING DRAWINGS FOR PIPE SIZES. 2. GREASE INTERCEPTOR DETAIL NEEDS TO BE VERFIED ON FIELD. 3. GREASE INTERCEPTOR LOCATION OUTSIDE THE BUILDING REFER 4' 0" TO FIRST FLOOR PLAN FOR GREASE INTERCEPTOR LOCATION. 4. REFER TO PLUMBING FIXTURE SCHEDULE P401 FOR GREASE INTERCEPTOR SPECIFICATIONS. L----------J L----L 'TOR DETAIL ROOF GAS PIPESUPPORT DETAIL TYPICAL TUB &SHOWER DETAIL RELEASED FOR CONSTRUCTION C I iBRq NOT TO SCALE `0 NOT TO SCALE Subject to compliance with all regulations of State and Local Codes City of Camel ee ((�� �1vm�tlonrkw�L BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 +888.901.8008 www.base-4.00m RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: y IN . VF QP: p \ S T Eq•� (? N Ua 1 12 9 ATE V Q"� OF FSS/ONAL i DATE :2019.06.05 GARRY VERMAAS, PhD, PE 2193 S BERIUM CHAPEL ROAD FRANKLIN, TN 37069 THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME y SUITES BY HILTBN CARMEL, INDIANA PROTOTYPE VERSION-V2.2 2016 REVISION: MAY 2016 ISSUE NO. DELTA ISSUED DATE DESCRIPTION 1 PO 201903.00 ISSUEDFORPERMIT 5 P4 201905.21 CITYCOMMENTS 6 P5 201905.05 CITYCOMMENTS CURRENTISSUE ISSUED FOR PERMIT CURRERTISSUEDATE 2019.03.04 DRAWN BY SPB CHECKD eY GWV PROJECTNO. B4-134-1705 SHEET NAME DETAILS-2 DRAWINGS NO. P=102 DATE: 07/22/19