HomeMy WebLinkAboutP-102 - DETAILS-2I TY�FI. PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE WASHER TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP CLEANOUT WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET FINISHED GRADE 02 WASHERS SANITARY OUTLET ( ) WIDTH=16" MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE BRONZE PLUG IN CAST IRON BODY. RAIN TROUGH FLOOR SLAB ON GRADE -CONCRETE PAD —_ FLOOR LEVEL SAME SIZE AS SEWER UP TO 6" MAXIMUM r 16"X16"X6" CONCRETE PAD AS REQUIRED FOR DEPTH OFONG SWEEP ELBOW AT LINT FILTER OR TURN OF RUN. DETAIL SEWER HUB AND SPIGOT CASTNO IRON PIPE BELOW FLOOR. COMBINATION WYE AND SANITARY OR STORM EIGHTH BEND IN RUN. 1/8 BEND IF C.O.00CURS SEWER LINE ENTER TOP OF PIPE. AT END OF LINE DRAIN -goo TROUGH DIRECTION OF FLOW n REMOVABLE LINT FILTER s (LOCATION -TYPICAL) LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS a LENGTH=88" OF PIPE GREATER THAN 45 DE EINTERVALS o OTTOM DRAIN ON STRAIGHT RUNS ,AND WHERE SHOWNN ON PLANS. PROVIDE BACKFILL PER AR N 18" CLECFICATIU LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. . E THERE 'III —III —III —III —III —III —III —III —III —III —III —III —III —III' CONSULT LOCAL CODES FOR OTHER FCO REIUIREMENTS. FLOOR CLEANOUT DETAIL CLEANOUT TO GRADE WASHER AND DRAIN TROUGH DETAIL 7 o V (� 9 NOT TO SCALE NOT TO SCALE NOT TO SCALE CONT. TO OTHER FLOORS CONT. TO OTHER FLOORS PTAC PTAC T4" PTAC CLEAN -OUT CLEAN -OUT CLEAN -OUT -FINISHED 3/4" TIPP 3/4" WALL SLOPE SLOPE FINISHED FINISHED FINISHED SLOPE FLOOR FLOOR FLOOR LEAD FLASHING IT OUT AND TURNED UNDER FLANGE REMOVABLE ROOF DOME 3K PTAC 3/4 PTAC RAVEL STOP AS REQUIRED PTAC 3/4" 3OR PLATES 3/4" ��� LCLEAN-OUT SLOPE SLOPE SLOPE EEE ZEE 3/4" 3/4" CONNECT TO THE CONNECT TO THE ADJUSTABLE COLLAR NEAREST STORM LINE. NEAREST STORM LINE. NOTES: 1. CONDENSATE PIPING FOR ALL UNITS ABOVE FIRST FLOOR ARE INSIDE WALL. _ + 2. CONDENSATE DRAIN PIPING TO BE AS SPECIFIED PER PLUMBING PLANS, IF NOT SPECIFIED, TO BE ROOF DRAIN OVERFLOW ROOF DRAIN T TYPE "L" COPPER OR PVC WHERE ALLOWED BY CODE WITH 1/2" ARMAFLEX INSULATION. 3. PROVIDE APPROVED WATER LEVEL DETECTOR OR FLOAT SWITCH TO AUTOMATICALLY SHUT DOWN NOTE: THE AIR CONDITIONING UNIT, AS A SECONDARY DRAIN SYSTEM TO COMPLY WITH MECHANICAL 1. CONTRACTOR SHALL VERIFY THAT INSTALLATION IS IN COMPLIANCE STATE BUILDING CODE. WITH ROOFING MANUFACTURERS RECOMMENDATIONS. END OF THE LINE TWO-WAY COMBINATION WYE AND EIGHT BEND WALL CLEANOUT 4. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP. 2. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ROOF 5. PITCH DRAIN FOR PROPER RUNOFF. CONSTRUCTION. 6. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM INITIAL DRAIN SEAL. 3. REFER TO SHEET P-401 FOR RD/ORD SPECIFICATION. 7. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAG AND CONDENSATE OVERFLOW. 8. CONDENSATE DRAIN PIPING SHALL MAINTAIN MINIMUM HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE NOT LESS THAN 118 UNIT VERTICAL IN 12 UNITS HORIZONTAL. FLOOR & WALL CLEANOUTS PTAC CONDENSATE DETAIL ROOF DRAIN DETAIL 013 L GA E�11 NOT TO SCALE NOT TO SCALE NOTE: METALSTUD ETAL STUD 1. BASE MATERIAL: POLY CARBONATE STRAP SECURED CPVC 6" AND 12" 2. SIZE: THE DECK BASE IS 6" SQUARE, THE STACKING PLATFORM IS 2" HIGH, TO STUD R2432 GRADE RINGS THE TOP OF THE "U" CRADLE IS 3" HIGH, AND THE MAXIMUM INSIDE WIDTH (TYPICAL) SECURE BRASS ELBOW TO 24" CAST IRON FRAMES AND COVERS S REQUIRED , EXTRA COST OF THE CRADLE IS 1.95". 6'-11'A.F. F. I� WOOD BLOCKING WITH SCREW WITH GASKET (GASTIGHT) STANDARD 3. MAX PIPE SIZE 1-1/2" INSIDE DIAMETER AND I-9(10"OUTSIDE DIAMETER. INFOW TEE 6 4. MAX PIPE CLEARANCE: PIPES SUPPORTED ON PIPE STAND WILL HAVE A SHOWER HEAD STANDPIPE OUTFLOW TEE + + 5. CLEARANCE OF 2"OVER THE ROOF. MAX LOAD WEIGHT: MAXIMUM LOAD &STANDPIPE WEIGHT MAY NOT EXCEED PER PIPE STAND. 6. SPACING: MANUFACTURERS RECOMMENDED RECOMMENDED SPACING IS NOT TO F. F. INVERT 4a " INVERT EXCEED 10 FEET CENTERS DEPENDING UPON THE LOAD. 7. USE 4-3/8" KWIK BOLT WITH 2" EMBEDMENT. —�6'-6"A. NLET. - UTLET 18'0" BLOCKING (FIRE TREATED COPPER C WOOD) TRANSITION FROM REX A TO D " PIPE AND FITTINGS E WOODBLOCKING (FIRE TREATED COPPER STANDARDS + + WOOD) SHOWER MIXING �2'.8"AF.F. VALVE SIDE SECTION VIEW COPPER 810 COPPER STRAPS NOTES: SECURED TO WOOD SECURE BRASS ELBOW TO BLOCKING WOOD BLOCKING WITH SCREW 1. REFER TO PLUMBING DRAWINGS FOR PIPE SIZES. (TYPICAL) 2. GREASE INTERCEPTOR DETAIL NEEDS TO BE VERFIED ON FIELD. 3. GREASE INTERCEPTOR LOCATION OUTSIDE THE BUILDING REFER TO FIRST FLOOR PLAN FOR GREASE INTERCEPTOR LOCATION. kk 1'-8" A.F.F. TUB FILLER 4. REFER TO SCHEDULE FOR GREASE INTERCEPTOR SCHEDULE SIZES. WOOD BLOCKING (FIRE TREATED WOOD) GREASE INTERCEPTOR DETAIL ROOF GAS PIPESUPPORT DETAIL TYPICAL TUB & SHOWER DETAIL G 13 4 5 NOT TO SCALE NOT TO SCALE NOT TO SCALE a RELEASED FOR CONSTRUCTION egL. A�Ip SadfeCl to CBl11PIdnCC WIIII all r49ad11Bn5 of Stale and Local Codes City d Camel hnl0 Y DATE: 07/22/19 BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 +888.901.8008 www.base-4.corn RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: Owner ' N 1 12 . 9 ATE OF _vv \Fo -•.D I A.- ,rani DATE : 2019.05.21 GARRY VERMAAS, PhD, PE 2193 S BERRYS CHAPEL ROAD FRANKLM. TN 37069 THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOMEN'. SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO. DELTA ISSUED DATE DESCRIPTION 1 Po 201903.04 ISSUMFORPORMIT 5 P4 W1905.21 lP.1TVrnwAMMTq CURRENTISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SPB CHECKED BY GWV PROJECT NO. 134-134-1705 SHEET NAME DETAILS-2 DRAWINGS NO. P-102